A sigma-delta ADC is a voltage-regulating analog-to-digital converter category that uses oversampling, noise shaping, and digital filtering to obtain high resolution. Its hierarchy includes ADC, data converter, analog-to-digital converter, and semiconductor. The AD7701BR is intended for sensors and industrial systems that require accurate conversion at a controlled data rate rather than the very high sampling rates associated with flash or SAR converters.
The converter provides 16-bit resolution, one analog input channel, a 4 kSPS maximum sampling capability, and a serial interface. These characteristics suit pressure, temperature, load-cell, chemical-sensor, and process-control signals that change slowly relative to the converter's digital filter bandwidth. A single-channel architecture also simplifies analog routing when one measurement must be isolated from noise or referenced independently.
Its sigma-delta conversion technique is particularly useful when the target signal contains substantial low-frequency noise. The internal digital filtering suppresses out-of-band noise and averages successive conversions, improving usable resolution for slow sensor outputs. Designers must still account for the digital filter's settling behavior, conversion-rate selection, reference quality, input filtering, and the relationship between programmed gain and the full-scale input range.
Typical applications include industrial process monitoring, laboratory instrumentation, portable measurement systems, weighing and load-cell interfaces, temperature measurement, and low-bandwidth sensor acquisition. The 20-pin SOIC package allows conventional surface-mount assembly and is useful where a compact, widely supported industrial package is preferred over a very small leadless package.
The primary design consideration is input filtering. Place a suitable anti-alias filter close to the analog input, use a clean reference source, and follow the manufacturer recommendations for analog and digital grounding. Keep switching supplies and high-current digital paths away from the input and reference traces to avoid converting supply noise into conversion error.
This product page combines the manufacturer specifications, package information, pricing structure, and replacement guidance for AD7701BR. It also identifies the closest package-compatible options and explains the verification steps needed before using any alternative in an existing 20-pin SOIC design.
جێگرەوەکانی جێگۆڕکێ بۆ AD7701BR — هەمان پاکەت، پین بە پین گونجاو. ئەو بەشانەی پاکەتی جیاوازیان هەیە و پێویستیان بە چاککردنەوەی PCB هەیە لابراون.
AD7701BRZ
✅ جێگرەوەی ڕاستەوخۆ📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)
AD7701ARZ
✅ جێگرەوەی ڕاستەوخۆ📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)
AD7701BR زۆرترین ڕێژە و تایبەتمەندییە کارەباییەکان
| وردی | 16 bit |
| Conversion Rate | 4 kSPS |
| Input Channels | 1 channel |
| Conversion Technique | Sigma-Delta |
| Process Technology | LC2MOS |
| Output Interface | Serial |
| پاکێج | 20-pin SOIC |
| Terminal Count | 20 terminals |
| Package Shape | Rectangular gull-wing SOIC |
| Temperature Grade | Industrial |
ڕێنمایی ڕێکخستنی پینی AD7701BR rectangular gull-wing soic
ڕێکخستنی پین بۆ AD7701BR (پاکێجی rectangular gull-wing soic). ئەم پێکھاتە ئەنالۆگە پینی چوونەژوورەوە، دەرچوون و دابینکردنی وزەی ھەیە. سەرنج بدە بە داتاشیتی بەرھەمھێنەر بۆ ڕێکخستنەکانی پینی لادانی ئۆفسێت، قەرەبووکردنەوە و چالاککردن. گونجاوە بۆ ڕێکخستنی ئیشارەت و خولەکانی بەرزکەرەوە.
هیچ داتای وردی پینئاوت بەردەست نییە بۆ AD7701BR.
سەرنج بدە بە داتاشیت بۆ ڕێکخستنی تەواوی پینەکان.
بەکارهێنانە باوەکان
AD7701BR گونجاوە بۆ 6 بەکارھێنانs: Industrial Pressure Measurement, Load Cell and Weighing Systems, Temperature Sensing and Control, Laboratory Precision Measurement, Chemical and Environmental Sensors, Portable Data Acquisition.
Industrial Pressure Measurement
The AD7701BR fits pressure-transducer monitoring because it combines 16-bit resolution with a controlled 4 kSPS conversion rate for relatively slow process signals. Place the bridge or conditioned pressure signal at the single analog input and allow the sigma-delta digital filter to settle after each conversion. This architecture favors stable readings over transient bandwidth. Use a low-noise reference, an anti-alias filter, and separated analog and digital return paths to prevent regulator switching noise from appearing as sensor pressure changes.
پێشنیارکراو
Load Cell and Weighing Systems
The AD7701BR is appropriate for load-cell signal chains where a millivolt-level differential measurement must be resolved with 16-bit precision. Its single input and sigma-delta filtering suit the slow force changes typical of static weighing, hopper monitoring, and bench scales. The 4 kSPS maximum rate provides sufficient response for many mechanical systems without accepting the power and complexity of a high-speed flash converter. Reference stability, input excitation noise, and digital-filter settling are the principal design concerns.
پێشنیارکراو
Temperature Sensing and Control
The AD7701BR can digitize conditioned outputs from RTDs, thermocouple amplifiers, thermistors, and digital temperature sensors without using a high-speed converter. A 16-bit result and sigma-delta noise filtering are useful when temperature changes slowly and measurement resolution matters more than acquisition rate. Configure the input range, gain, reference voltage, and filter bandwidth together so that the sensor signal remains within the converter's calibrated range. Place input filtering close to the analog pins to reject interference from adjacent switching equipment.
پێشنیارکراو
Laboratory Precision Measurement
The AD7701BR is useful in laboratory instruments that measure low-frequency analog quantities with modest conversion throughput. Its 16-bit sigma-delta architecture supports accurate digitization of conditioned voltage, current, and resistance measurements while the 4 kSPS ceiling remains adequate for many panel meters and process analyzers. Instrument designers should account for filter latency, reference drift, input bias behavior, and calibration when defining displayed resolution. A shielded analog section and careful ground partition improve repeatability in a shared measurement environment.
پێشنیارکراو
Chemical and Environmental Sensors
The AD7701BR suits electrochemical, gas, pH, conductivity, and environmental sensor interfaces whose outputs vary slowly and often require substantial gain before conversion. The converter's 16-bit resolution and sigma-delta filtering can capture small changes around a slowly drifting baseline, while the single input simplifies dedicated measurement channels. The design must select a compatible gain and input range, provide a stable reference, and allow sufficient filter settling. Electrochemical applications also require careful isolation from motors, heaters, and switching supplies.
پێشنیارکراو
Portable Data Acquisition
The AD7701BR can serve as the measurement engine in portable battery-powered data loggers that record slow sensor channels. Its single-channel sigma-delta design provides 16-bit results at up to 4 kSPS without requiring a rapid conversion pipeline, making it suitable for periodic logging rather than high-speed waveform capture. Low-power operation should be evaluated from the complete analog and digital system because the converter's supply behavior and filter settling contribute to the overall duty cycle. Use a low-noise reference and energy-efficient signal conditioning to preserve battery life.
پێشنیارکراو
کورتەی بەرهەمە پێشنیارکراوەکان
داتای سەرچاوەی ئەندازیاری بۆ AD7701BR — بەراوردکردن، ڕێنمایی دیزاین و زانیاری پابەندبوون.
ڕێنمایی هەڵبژاردن
بەراوردکردن لەگەڵ جێگرەوەکان
| پارامەتر | ئەم بەرهەمە | AD7701BRZ | AD7701ARZ |
|---|---|---|---|
| Package | SOIC-20 | SOIC-20 | SOIC-20 |
| Brand | Analog Devices | Analog Devices | Analog Devices |
| Resolution | 16 bit | 16 bit | 16 bit |
| Conversion Technique | Sigma-Delta | Sigma-Delta | Sigma-Delta |
| Input Channels | 1 channel | 1 channel | 1 channel |
| Maximum Conversion Rate | 4 kSPS | 4 kSPS | 4 kSPS |
| Output Interface | Serial | Serial | Serial |
| Process Technology | LC2MOS | LC2MOS | LC2MOS |
جیاکەرەوە سەرەکییەکان
- Single-channel 16-bit conversion in a conventional 20-pin SOIC (بەراورد بەAD7701ARZ)
- Direct pin-compatible family option for existing 20-pin SOIC layouts (بەراورد بەAD7701BRZ)
- Purpose-built for low-bandwidth precision measurement (بەراورد بەAD7701ARZ)
تێبینییەکانی دیزاین
Route the analog input, reference, and analog ground directly to the AD7701BR and keep the paths short. Place the input anti-alias capacitor and any recommended filtering components close to the corresponding pins rather than beside the sensor connector. A long unprotected input trace can pick up capacitive coupling from switching nodes, and a reference trace routed beside a digital clock line can add conversion error even when the nominal resolution is 16 bit.
Design the digital-filter and conversion sequence around the selected data rate. Sigma-delta conversion does not produce a settled result immediately after an input change, so the firmware should discard or identify transitional samples when measurements are not stationary. Verify the acquisition timing and serial-transfer rate together so that communication does not overlap the converter's required settling interval. This is especially important in multiplexed systems where the input changes between channels.
Use a quiet reference and separate the converter's analog supply path from noisy switching loads. Reference drift appears directly as measurement drift, while supply ripple can modulate the converter's analog front end and degrade noise performance. Keep the reference and analog-ground return paths compact, inspect the power tree for shared high-current junctions, and follow the manufacturer's recommendations for bypassing capacitors and grounding. Validate the completed board across its full supply range and operating temperature.
Do not treat the 16-bit resolution label as guaranteed effective accuracy without considering noise, reference quality, gain error, and filter settling. Likewise, the 4 kSPS maximum rate does not mean every filtered reading is available every 4 milliseconds under all gain and data-rate settings. Check the filter implementation and gain-dependent timing in the manufacturer datasheet before setting acquisition timing, and use the correct full-scale range for the sensor being measured.
زانیاری پابەندبوون
The AD7701 family is listed as production by Analog Devices. No specific RoHS, REACH, lead-free, halogen-free, conflict-minerals, or automotive qualification statement was established for the exact AD7701BR ordering suffix.