ADS1253E - 24-Bit 20-kSPS 4-Channel Delta-Sigma ADC | Texas Instruments
MPN: ADS1253E ✓ چالاکADS1253E گشتی
A delta-sigma ADC is a category of data-converter IC that uses oversampling, digital filtering, and noise shaping to provide high resolution and excellent dynamic range. The ADS1253E belongs to the broader analog-to-digital converter, data-acquisition IC, and signal-chain semiconductor hierarchy. Compared with a SAR ADC operating at comparable conversion rates, this architecture favors precision measurement over very high throughput, making it appropriate for sensor instrumentation, industrial monitoring, and laboratory data acquisition.
The ADS1253E provides 24-bit nominal resolution, 19-bit effective resolution at 20 kSPS, four differential input channels, and 1.8 ppm RMS noise. An integrated four-input multiplexer allows one converter core to service multiple analog sources. The device also includes an external reference input, power-down mode, and synchronization support. These features let a compact design acquire several low-level channels while controlling power and coordinating conversion timing with external equipment.
Its delta-sigma conversion stage uses continuous-time sampling and digital filtering to trade conversion latency for noise performance and selectivity. A four-input differential multiplexer precedes the converter, allowing paired positive and negative analog inputs to be selected for conversion. The 20 kSPS rate is suitable for pressure, temperature, load-cell, chemical, and process-control signals that require high resolution but do not require megahertz sampling. The 1.8 ppm RMS noise specification supports stable measurements when the input-referred noise must remain well below the signal of interest.
Typical applications include industrial pressure and flow measurement, strain-gauge and load-cell instrumentation, temperature sensing, laboratory measurement systems, and multichannel data-acquisition boards. The four differential inputs reduce the number of external converters needed when several sensors share a common reference. Synchronization support can also help align measurements across multiple converters when coordinated acquisition is required.
Design the analog input network to preserve the converter’s differential performance. Keep input traces short, use a low-noise reference, provide local supply bypassing, and ensure source impedances are balanced across differential pairs. Confirm the required data rate, digital filter settling time, input range, and clock configuration with the manufacturer datasheet before fixing the system sampling schedule. External reference and input filtering components should be selected for the required bandwidth and noise target.
This product record combines the ADS1253E conversion specifications, package details, application guidance, and replacement considerations into an engineering-oriented reference. It also distinguishes verified same-package family options from converters that require a different footprint, helping designers evaluate PCB reuse without confusing functional similarity with true drop-in compatibility.
جێگرەوەکانی جێگۆڕکێ بۆ ADS1253E — هەمان پاکەت، پین بە پین گونجاو. ئەو بەشانەی پاکەتی جیاوازیان هەیە و پێویستیان بە چاککردنەوەی PCB هەیە لابراون.
جۆرەکان لەم زنجیرەیەدا
مۆدێلەکانی هەمان زنجیرە کە بە شێوەی ڕاستەوخۆ گونجاون لەگەڵ ADS1253E (هەمان شێوە و پێکهاتەی شوێن) — جیاوازە لە Number of Input Channels.
ADS1253E/2K5
✅ جێگرەوەی ڕاستەوخۆ📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)
ADS1253E/2K5G4
✅ جێگرەوەی ڕاستەوخۆ📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)
ADS1253EG4
✅ جێگرەوەی ڕاستەوخۆپەیوەندی بۆ نرخ
بینینی داتاشیت →ADS1253E زۆرترین ڕێژە و تایبەتمەندییە کارەباییەکان
| ADC Type | Delta-sigma analog-to-digital converter |
| وردی | 24 bit |
| Effective Resolution | 19 bit at 20 kSPS |
| Maximum Conversion Rate | 20 kSPS |
| Number of Input Channels | 4 |
| Input Configuration | 4 differential inputs |
| ڤۆڵتیەی دابینکردن | +5 V single supply |
| Input-Referred Noise | 1.8 ppm RMS |
| Integral Nonlinearity | 15 ppm maximum |
| No-Missing-Codes Performance | 24 bits |
| Reference Input | External 5 V reference |
| ڕووکار | SPI synchronous serial interface |
| Power-Down Mode | Supported |
| Synchronization Mode | Supported |
| پاکێج | 16-SSOP |
| جۆری دامەزراندن | Surface mount |
ڕێنمایی ڕێکخستنی پینی ADS1253E 16-ssop
ڕێکخستنی پین بۆ ADS1253E (پاکێجی 16-ssop). ئەم پێکھاتە ئەنالۆگە پینی چوونەژوورەوە، دەرچوون و دابینکردنی وزەی ھەیە. سەرنج بدە بە داتاشیتی بەرھەمھێنەر بۆ ڕێکخستنەکانی پینی لادانی ئۆفسێت، قەرەبووکردنەوە و چالاککردن. گونجاوە بۆ ڕێکخستنی ئیشارەت و خولەکانی بەرزکەرەوە.
هیچ داتای وردی پینئاوت بەردەست نییە بۆ ADS1253E.
سەرنج بدە بە داتاشیت بۆ ڕێکخستنی تەواوی پینەکان.
بەکارهێنانە باوەکان
ADS1253E گونجاوە بۆ 6 بەکارھێنانs: Industrial Pressure and Flow Instrumentation, Load-Cell and Strain-Gauge Measurement, Precision Temperature Sensing, Laboratory Data-Acquisition Systems, Multichannel Sensor Acquisition, Process-Control and Monitoring Equipment.
Industrial Pressure and Flow Instrumentation
The ADS1253E fits industrial pressure and flow measurement because its four differential inputs support several sensor channels while its 24-bit architecture provides high conversion resolution. At up to 20 kSPS, the converter achieves 19-bit effective resolution and 1.8 ppm RMS noise, which is appropriate for slowly varying process signals. Place the converter behind the transmitter’s bridge or instrumentation-amplifier stage, use the external 5 V reference, and allow sufficient digital-filter settling time between channel selections. The principal benefit is precise multiplexing without requiring four separate converter ICs; the trade-off is limited throughput compared with a high-speed SAR ADC.
پێشنیارکراو
Load-Cell and Strain-Gauge Measurement
The ADS1253E is well suited to load-cell and strain-gauge front ends that measure small differential voltages produced by a resistive bridge. Its four differential inputs can serve multiple bridge channels, while 19-bit effective resolution at 20 kSPS and 1.8 ppm RMS noise provide useful signal-to-noise headroom. The converter should follow a low-noise bridge excitation, balanced input network, and differential analog filter. Keep bridge excitation and reference routing away from digital return currents, and use the external 5 V reference to maintain ratio accuracy when excitation changes. The main benefit is resolution; the main limitation is the conversion rate for rapidly changing mechanical loads.
پێشنیارکراو
Precision Temperature Sensing
The ADS1253E can digitize low-level temperature sensor signals when high resolution and repeatable acquisition are more important than rapid sampling. Its 19-bit effective resolution at 20 kSPS helps preserve small changes from RTDs, thermocouple amplifiers, or resistive temperature bridges, while four differential inputs reduce converter count in multizone equipment. Use a low-drift external 5 V reference and balanced differential routing to limit drift and error. Configure the digital filter for the required response rather than automatically using the highest data rate. This approach trades acquisition latency for measurement resolution and is best for thermal monitoring, ovens, and laboratory temperature chambers.
پێشنیارکراو
Laboratory Data-Acquisition Systems
The ADS1253E supports laboratory and bench data-acquisition systems that measure several slow, low-level channels through a common reference. Its 24-bit converter, four differential inputs, 20-kSPS maximum rate, synchronization mode, and SPI interface allow compact multi-channel acquisition. Use synchronized sampling when comparing multiple channels and allow the digital filter to settle before each result. A shared precision reference can support consistent readings across channels, while careful grounding and shielding are necessary in low-level bench systems. The converter is appropriate for pressure, strain, voltage, and resistance studies where resolution outweighs waveform-capture speed.
پێشنیارکراو
Multichannel Sensor Acquisition
The ADS1253E is appropriate for multichannel sensor acquisition where four differential pairs must be digitized by one compact converter. Its integrated multiplexer reduces component count, and the 1.8 ppm RMS noise specification provides a strong foundation for low-level measurements. Program the digital filter for the required bandwidth and latency, then schedule channel changes with sufficient settling time. Keep each pair’s source impedances and common-mode levels compatible with the analog input stage. This architecture is useful in building automation, environmental monitoring, and equipment diagnostics, where changing sensor values are sampled rather than captured as high-frequency waveforms.
پێشنیارکراو
Process-Control and Monitoring Equipment
The ADS1253E can serve as the measurement ADC in process-control equipment that must monitor slow analog process variables with high resolution. Its 19-bit effective resolution at 20 kSPS supports fine process adjustments, while the four differential inputs provide channel scalability. Pair the converter with a protected analog front end, a low-noise reference, and synchronization when multiple measurement modules must operate coherently. Power-down mode can reduce consumption during inactive periods, although restart sequencing and filter settling must be included in the control cycle. The component is strongest in closed-loop or supervisory systems where accurate readings are more important than ultra-fast sampling.
پێشنیارکراو
کورتەی بەرهەمە پێشنیارکراوەکان
داتای سەرچاوەی ئەندازیاری بۆ ADS1253E — بەراوردکردن، ڕێنمایی دیزاین و زانیاری پابەندبوون.
ڕێنمایی هەڵبژاردن
بەراوردکردن لەگەڵ جێگرەوەکان
| پارامەتر | ئەم بەرهەمە | ADS1253E/2K5 | ADS1253E/2K5G4 | ADS1253EG4 |
|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | 16-SSOP | 16-SSOP - same | 16-SSOP - same | 16-SSOP - same |
| Resolution | 24 bit | 24 bit | 24 bit | 24 bit |
| Maximum Conversion Rate | 20 kSPS | 2.5 kSPS | 2.5 kSPS | 20 kSPS |
| Input Channels | 4 differential inputs | 4 differential inputs | 4 differential inputs | 4 differential inputs |
| Supply Voltage | +5 V single supply | +5 V single supply | +5 V single supply | +5 V single supply |
| External Reference | 5 V external reference | 5 V external reference | 5 V external reference | 5 V external reference |
جیاکەرەوە سەرەکییەکان
- Higher conversion throughput than the 2.5 kSPS family ordering option (بەراورد بەADS1253E/2K5)
- Four-input multiplexing in a 16-SSOP footprint (بەراورد بەADS1252U)
- Precision conversion with integrated channel multiplexing (بەراورد بەADS1240E)
تێبینییەکانی دیزاین
Route each differential input as a closely coupled pair and keep the analog path short and away from SPI clock, data, and switching-node traces. Balanced source impedances help the four-input multiplexer acquire channels consistently. Place input and reference bypass capacitors near their associated pins and use a quiet ground strategy so reference current does not share a noisy return path with the converter. The 16-SSOP footprint provides limited lead spacing, so component placement and trace direction should follow the manufacturer’s recommended layout rather than relying on general guidance.
Treat the external 5 V reference as an analog precision signal. Use a low-noise source, local decoupling, and a return path that avoids digital and switching currents. If the source resistance is too high, dynamic errors may appear during multiplexer transitions; verify source impedance and acquisition settling against the manufacturer’s input network recommendations. Because ADS1253E provides 19-bit effective resolution at 20 kSPS, reference noise and ground coupling can become important even though the nominal converter resolution is 24 bits.
Do not schedule the next result before the selected channel and the configured digital filter have settled. The 20-kSPS conversion rate is not necessarily the usable sample rate for every filter and data-rate setting. Review the timing diagram, digital-filter latency, and data-ready behavior in the manufacturer datasheet. Also avoid treating ADS1252 and ADS1251 as drop-in substitutes: they use different packages and omit the ADS1253E four-input multiplexer arrangement.
Keep the analog reference and input network physically separated from switching supplies, relays, motor-control traces, and high-current return paths. Use a single-point or carefully controlled grounding strategy at the analog interface, and place filtering close to the converter inputs rather than at the sensor cable. If the ADS1253E is installed near a switching converter, verify conducted and radiated noise at the ADC input and reference because high effective resolution cannot recover noise already coupled into the measurement signal.
زانیاری پابەندبوون
No explicit compliance declarations are stated for this exact ordering code. Use the manufacturer product page and current material-compliance declarations for production qualification.