BCM8727CIFBG - 10GbE Dual SFI-to-XAUI PHY | Broadcom
MPN: BCM8727CIFBG ✓ چالاکBCM8727CIFBG گشتی
A 10GbE physical-layer transceiver is an interface IC that converts parallel or lane-based digital data into electrical signaling suitable for high-speed copper links. Within the broader semiconductor hierarchy, the BCM8727CIFBG is a networking transceiver, then an interface IC, and finally a general-purpose semiconductor. Its dual-channel architecture reduces the number of physical-layer devices needed in a two-lane network interface while supporting the widely deployed 10GbE SFI and XAUI interface types.
The principal defined features are two independent 10GbE channels, a 10.3125 Gb/s data rate, SFI input interfacing, and XAUI output interfacing. These characteristics make the part relevant to designs that need deterministic 10GbE connectivity rather than general-purpose serial communications. The BCM8727CIFBG is especially relevant to enterprise switching, data-center interconnect, server networking, optical-module host interfaces, and telecommunications aggregation equipment.
Its dual-channel configuration allows a board designer to implement two 10GbE paths through one component, supporting efficient use of board area and system power. XAUI provides a wide, parallel interface between a MAC or switching fabric and the physical layer, while SFI supplies a high-speed serial link toward an optical or copper transceiver. The resulting partition of responsibilities can simplify board partitioning when the external line-card or pluggable transceiver performs the final medium conversion.
Typical deployments include 10GbE switches, routers, network interface cards, servers, storage systems, and optical transport equipment. In these systems, the BCM8727CIFBG can serve as the copper-side interface between high-speed digital logic and an SFI-capable optical module. It is also appropriate for test equipment and communication backplanes where dual-channel 10GbE connectivity is required.
Design integration should focus on exact pin assignment, differential-signal routing, reference-clock requirements, power-supply sequencing, and decoupling. Use the Broadcom datasheet pin-description table when assigning PCB tracks and the reference-design layout when reproducing the recommended high-speed topology. Confirm package dimensions, exposed-pad requirements, operating-temperature limits, and electrical timing before releasing a layout.
This product record combines the verified BCM8727CIFBG catalog description with practical interface-selection guidance, procurement instructions, and a structured framework for comparing pin-compatible alternatives. It also identifies which electrical and mechanical details must be confirmed in the manufacturer datasheet before a production design is approved.
جێگرەوەکانی جێگۆڕکێ بۆ BCM8727CIFBG — هەمان پاکەت، پین بە پین گونجاو. ئەو بەشانەی پاکەتی جیاوازیان هەیە و پێویستیان بە چاککردنەوەی PCB هەیە لابراون.
جۆرەکان لەم زنجیرەیەدا
مۆدێلەکانی هەمان زنجیرە کە بە شێوەی ڕاستەوخۆ گونجاون لەگەڵ BCM8727CIFBG (هەمان شێوە و پێکهاتەی شوێن) — جیاوازە لە Data Rate per Channel.
هیچ جێگرەوەی ڕاستەوخۆ بۆ ئەم بەرهەمە بەردەست نییە.
داوای جێگرەوەکان بکەBCM8727CIFBG زۆرترین ڕێژە و تایبەتمەندییە کارەباییەکان
| Product Type | Dual-channel 10GbE SFI-to-XAUI PHY transceiver |
| Channel Count | 2 channels |
| Data Rate per Channel | 10.3125 Gb/s |
| Nominal Ethernet Rate | 10 GbE |
| Serial Input Interface | SFI |
| Parallel Output Interface | XAUI |
| Application Classification | Drivers, receivers, and transceivers |
| دۆخی RoHS | unknown |
| REACH Status | unknown |
ڕێنمایی ڕێکخستنی پینی BCM8727CIFBG standard
ڕێکخستنی پین بۆ BCM8727CIFBG (پاکێجی standard). ئەم پێکھاتە ئەنالۆگە پینی چوونەژوورەوە، دەرچوون و دابینکردنی وزەی ھەیە. سەرنج بدە بە داتاشیتی بەرھەمھێنەر بۆ ڕێکخستنەکانی پینی لادانی ئۆفسێت، قەرەبووکردنەوە و چالاککردن. گونجاوە بۆ ڕێکخستنی ئیشارەت و خولەکانی بەرزکەرەوە.
هیچ داتای وردی پینئاوت بەردەست نییە بۆ BCM8727CIFBG.
سەرنج بدە بە داتاشیت بۆ ڕێکخستنی تەواوی پینەکان.
بەکارهێنانە باوەکان
BCM8727CIFBG گونجاوە بۆ 6 بەکارھێنانs: 10GbE Enterprise Switching, Router and Network Interface Cards, Optical Module Host Interface, Data-Center Server Connectivity, Storage and Network Attached Systems, Telecommunications Aggregation Equipment.
10GbE Enterprise Switching
The BCM8727CIFBG fits an enterprise switch line card that must terminate two 10.3125 Gb/s channels while converting between SFI and XAUI. Its dual-channel architecture can reduce the number of physical-layer devices compared with two single-channel implementations, helping conserve board area and simplify control-plane connections. XAUI connects to the switching or MAC logic, while SFI connects toward an optical or copper transceiver. Before layout, verify channel assignment, clock distribution, lane polarity, power sequencing, and every signal against the manufacturer datasheet.
پێشنیارکراو
Router and Network Interface Cards
In a router or 10GbE network interface card, the BCM8727CIFBG can provide two high-speed physical-layer paths between a packet-processing ASIC and SFI-capable external media modules. The 10.3125 Gb/s per-channel rate supports 10GbE links, while XAUI offers a parallel interface to a switch fabric or MAC. The design must maintain suitable trace geometry, differential impedance, reference-clock integrity, and supply decoupling across both channels. Module power, optical budget, connector layout, and thermal requirements remain external to the BCM8727CIFBG.
پێشنیارکراو
Optical Module Host Interface
The BCM8727CIFBG is applicable to the host side of a dual-channel 10GbE optical interface when the host processor uses XAUI and the optical module exposes SFI. This arrangement separates high-speed parallel chip-to-chip signaling from the module's serial electrical interface. The implementation should use short, controlled-impedance XAUI routes and carefully terminate SFI differential pairs. Confirm module vendor compatibility, lane mapping, clock source, receiver termination, insertion-loss budget, and thermal conditions before production because those constraints cannot be inferred from the BCM8727CIFBG catalog description alone.
پێشنیارکراو
Data-Center Server Connectivity
The BCM8727CIFBG can support dual 10GbE connectivity in a data-center server interface card that bridges a network processor to SFI-capable transceivers. Two integrated 10.3125 Gb/s channels can simplify the physical-layer section of a dual-port network card. Practical deployment depends on the server's power budget, airflow, connector placement, and expected electromagnetic environment. Use short reference-clock routes, continuous return planes, localized decoupling, and the manufacturer layout recommendations to preserve signal integrity between the PHY, processing silicon, and external modules.
پێشنیارکراو
Storage and Network Attached Systems
A storage enclosure or network-attached storage controller can use the BCM8727CIFBG when it requires two 10GbE physical-layer channels based on SFI and XAUI. The dual-channel configuration provides a path for high-bandwidth Ethernet traffic between a storage controller or switch ASIC and pluggable network media. Design the board around the exact package pinout, supply domains, clocking method, and differential-routing rules in the manufacturer documentation. Confirm that the storage controller supports XAUI and that the selected SFI module is compatible with the intended optical or copper medium.
پێشنیارکراو
Telecommunications Aggregation Equipment
The BCM8727CIFBG is suitable for telecommunications aggregation and transport equipment that uses dual 10GbE backplane or service links implemented through XAUI-to-SFI conversion. It can bridge parallel switching logic to SFI-based line-card modules while supporting a 10.3125 Gb/s rate on each channel. Telecom-oriented deployments require careful review of temperature grade, lifecycle status, power resilience, and long-term supply requirements. The PCB should follow the recommended high-speed stack-up and decoupling arrangement, with thermal design based on actual channel activity rather than nominal throughput alone.
پێشنیارکراو
کورتەی بەرهەمە پێشنیارکراوەکان
داتای سەرچاوەی ئەندازیاری بۆ BCM8727CIFBG — بەراوردکردن، ڕێنمایی دیزاین و زانیاری پابەندبوون.
ڕێنمایی هەڵبژاردن
بەراوردکردن لەگەڵ جێگرەوەکان
| پارامەتر | ئەم بەرهەمە |
|---|---|
| Brand | Broadcom |
| Channel Count | 2 channels |
| Data Rate per Channel | 10.3125 Gb/s |
| Nominal Ethernet Rate | 10 GbE |
| Serial Interface | SFI |
| Parallel Interface | XAUI |
| Product Classification | Interface IC: driver, receiver, and transceiver |
| RoHS Status | unknown |
| REACH Status | unknown |
جیاکەرەوە سەرەکییەکان
- Integrated dual-channel 10GbE physical layer (بەراورد بەSingle-channel 10GbE transceiver designs)
- Direct SFI-to-XAUI interface conversion (بەراورد بەTransceivers using an intermediate parallel interface conversion)
- Nominal 10GbE line rate on both channels (بەراورد بەLower-rate single-channel Ethernet PHYs)
تێبینییەکانی دیزاین
Treat both SFI and XAUI interfaces as controlled-impedance high-speed links. Follow the manufacturer stack-up, loss budget, via geometry, differential-pair spacing, and connector or module escape recommendations exactly. Do not route SFI and XAUI through unrelated power or ground-plane splits; maintain a continuous return path beneath each signal route and use the pin-description table to confirm lane assignments before PCB routing.
Establish the BCM8727CIFBG supply topology, sequencing, and decoupling from the manufacturer datasheet before placing capacitors. Place high-frequency and bulk capacitors close to their designated pins with short ground returns, and account for simultaneous activity on both 10.3125 Gb/s channels. Validate power sequencing, ripple, droop, and channel-to-channel coupling in simulation or on a representative board before production release.
Estimate power dissipation from the actual channel utilization, supply voltage, current draw, and ambient conditions rather than from the 10GbE headline rate alone. Provide copper area under the package and thermal vias according to the package drawing and layout guidance. Confirm the device temperature grade and maximum operating temperature before using it in constrained industrial, storage, or telecommunications enclosures.
Do not treat a similarly named Broadcom ordering code as an automatic drop-in replacement. The suffix may encode package, temperature, or lifecycle differences, and comparison pages alone do not establish pin compatibility. Verify the complete ordering table, footprint, pin names, supply levels, reference clock, timing, and thermal limits for BCM8727MBIFBG, BCM8705LBIFBG, or any other candidate before changing the BOM or releasing production artwork.
Use the manufacturer reference layout as the starting point for component placement and high-speed routing. Keep the reference-clock network away from noisy power stages and maintain symmetric routing where possible. Avoid placing test pads or connectors on sensitive nets unless their loading is included in simulation. Validate the final stack-up with field solvers and perform eye, jitter, and compliance testing on representative hardware before production.
زانیاری پابەندبوون
The available comparison material identifies RoHS and REACH as comparison attributes but does not state their compliance results for BCM8727CIFBG. Compliance and qualification status must be confirmed in the current Broadcom product documentation or declaration of compliance.