Maxim Integrated

ICL7126RCPL+ - 3-1/2 Digit LCD ADC | Maxim Integrated

MPN: ICL7126RCPL+ ✓ چالاک
1 pA Id 40-pin PDIP Package
MOQ: 1 |

ICL7126RCPL+ گشتی

The Maxim Integrated ICL7126RCPL+ is a 3-1/2-digit, low-power, dual-slope analog-to-digital converter with direct LCD display drive, parallel word access, true differential input and reference, and a 40-pin PDIP package. It integrates the active circuitry required for a precision measurement system, including seven-segment decoders, display drivers, a voltage reference, and a clock circuit. The device accepts one analog input channel and is designed for panel-meter, laboratory, and portable-instrument applications.

A 3-1/2-digit ADC is an integrating converter whose resolution is commonly expressed as 1/2 of a full-scale digit. This architecture is useful when the measured quantity changes relatively slowly and when rejection of mains-related ripple is important. Within the broader semiconductor hierarchy, the ICL7126RCPL+ is an ADC, then a data-conversion IC, then an integrated circuit used within an electronic measurement or display system.

Principal features include a direct LCD output, typical input current of 1 pA, true polarity at zero for precise null detection, and a guaranteed zero reading for a zero-volt input on all ranges. The converter also supports a typical 8,000-hour operating life from a 9 V battery. These characteristics make it useful in high-impedance measurement circuits where input leakage and reference errors could otherwise distort the displayed value.

Internally, the dual-slope conversion process integrates the unknown input over a fixed interval and compares the result with a reference interval. Integration can suppress periodic noise, while the internal reference and clock reduce the number of precision external components required. The integrated seven-segment decoders and digit drivers reduce display-interface complexity by driving a compatible LCD directly.

Typical uses include digital panel meters, temperature measurement instruments, laboratory readouts, portable test equipment, process monitoring, and low-power battery-operated meters. In these applications, the converter combines analog measurement, normalization, digit generation, and LCD output in one package. The 40-pin PDIP format also favors through-hole construction and repairable industrial or laboratory equipment.

When designing the circuit, follow the manufacturer datasheet for reference capacitors, integration and conversion timing, input-source impedance limits, display glass connections, and supply bypass requirements. Component tolerances and leakage can affect accuracy in very high-impedance circuits. PCB cleanliness, guarded input routing, stable reference components, and protection from electrostatic discharge are particularly important in precision measurement equipment.

This product page combines the converter’s principal electrical characteristics, package information, application guidance, comparison criteria, and practical design considerations into one engineering-focused reference. It also distinguishes exact suffix and family alternatives from functionally similar converter types so that footprint, interface, and display requirements can be checked before a replacement is selected.

جێگرەوەکانی جێگۆڕکێ بۆ ICL7126RCPL+ — هەمان پاکەت، پین بە پین گونجاو. ئەو بەشانەی پاکەتی جیاوازیان هەیە و پێویستیان بە چاککردنەوەی PCB هەیە لابراون.

ICL7126RCPL

✅ جێگرەوەی ڕاستەوخۆ
📦 40-pin PDIP
Same ICL7126 function and 40-pin PDIP footprint; ordering-code qualification differs, with no verified quantitative electrical delta.

📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)

ICL7126CPLZ

✅ جێگرەوەی ڕاستەوخۆ ⚠️ تایبەتمەندییەکان پشتڕاست نەکراونەتەوە
Renesas Electronics
📦 40-pin PDIP
Dual-slope integrating ADC · 3.5 digits, 1999 counts · 3 samples per second · 100 µA · CMOS · Direct seven-segment LCD drive · Segment decoders, display drivers, voltage reference, and clock · Integrated

پەیوەندی بۆ نرخ

بینینی داتاشیت →

ICL7126RCPLZ

✅ جێگرەوەی ڕاستەوخۆ ⚠️ تایبەتمەندییەکان پشتڕاست نەکراونەتەوە
📦 40-pin PDIP
Same ICL7126 converter and 40-pin PDIP footprint; lead-free ordering suffix differs, with no verified change to the conversion architecture.

📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)

ICL7126RCPL+ زۆرترین ڕێژە و تایبەتمەندییە کارەباییەکان

ADC Type Dual-slope ADC
وردی 3-1/2 digits
Input Channels 1 channel
Output Interface Parallel word access
Process Technology CMOS
Display Output Direct 7-segment LCD drive
Input Reference True differential input and reference
Typical Input Current 1 pA
Zero-Input Reading Zero reading for 0 V input on all scales
Zero Polarity True polarity at zero for precise null detection
Typical Battery Life 8,000 hours from a 9 V battery
پاکێج 40-pin PDIP
Package Body Width 0.600 in (15.24 mm)
جۆری دامەزراندن Through-hole

ڕێنمایی ڕێکخستنی پینی ICL7126RCPL+ 0.600 in (15.24 mm)

ڕێکخستنی پین بۆ ICL7126RCPL+ (پاکێجی 0.600 in (15.24 mm)). ئەم پێکھاتە ئەنالۆگە پینی چوونەژوورەوە، دەرچوون و دابینکردنی وزەی ھەیە. سەرنج بدە بە داتاشیتی بەرھەمھێنەر بۆ ڕێکخستنەکانی پینی لادانی ئۆفسێت، قەرەبووکردنەوە و چالاککردن. گونجاوە بۆ ڕێکخستنی ئیشارەت و خولەکانی بەرزکەرەوە.

نەخشەی پینئاوتی پاکێجی 0.600 in (15.24 mm) بۆ ICL7126RCPL+

هیچ داتای وردی پینئاوت بەردەست نییە بۆ ICL7126RCPL+.

سەرنج بدە بە داتاشیت بۆ ڕێکخستنی تەواوی پینەکان.

بەکارهێنانە باوەکان

ICL7126RCPL+ گونجاوە بۆ 6 بەکارھێنانs: Digital Panel Meters, Battery-Powered Test Instruments, Laboratory Voltage Measurement, Temperature and Process Monitoring, Portable Electrical Measurement, Calibration and Null Detection.

🔧

Digital Panel Meters

The ICL7126RCPL+ fits a digital panel meter because it combines a 3-1/2-digit dual-slope ADC with seven-segment decoders, display drivers, a reference, and a clock. This integration allows a meter to normalize an analog sensor signal and present it on a compatible LCD without a separate display-driver IC. The typical 1 pA input current is especially useful with high-impedance dividers or sensing networks, while true differential input and reference help reject common-mode errors. The 40-pin PDIP package also supports repairable through-hole instruments. The principal design constraint is matching the display-glass connections and external timing network to the manufacturer datasheet.

🔋

Battery-Powered Test Instruments

The ICL7126RCPL+ is appropriate for battery-powered test instruments where low-power operation and direct LCD output simplify the signal chain. Its 9 V battery operating characteristic specifies a typical 8,000-hour life under the manufacturer’s stated conditions, making it useful for portable voltmeters, continuity testers, and general-purpose bench probes. The CMOS dual-slope architecture is better suited to slowly changing measurements than to high-speed waveform acquisition. Designers should account for display duty cycle, reference-capacitor selection, and conversion timing because actual battery life depends on those operating choices as well as the selected battery.

🧪

Laboratory Voltage Measurement

The ICL7126RCPL+ can form the measurement core of a laboratory voltmeter because it provides 3-1/2-digit conversion, true differential input and reference, and integrated LCD drive in a single 40-pin PDIP. Differential measurement helps reject offset and noise shared by the input and reference paths, while the converter’s low typical input current reduces loading of high-impedance dividers. The device is most appropriate for stable DC measurements rather than fast transient capture. Board leakage, input protection leakage, reference accuracy, and display timing must be controlled to preserve useful resolution across the complete measurement range.

🏭

Temperature and Process Monitoring

The ICL7126RCPL+ suits temperature and process monitoring systems that require a readable numeric indication rather than a high-rate data stream. A resistive or semiconductor sensor can feed the differential input, and the converter can scale the result through the external reference and timing network before driving the LCD. True polarity at zero supports precise null detection, while the guaranteed zero reading for a zero-volt input helps verify a stable baseline. The design must include sensor-specific linearization where required, and its input impedance and settling time must satisfy the manufacturer’s source-impedance limits.

⚡

Portable Electrical Measurement

The ICL7126RCPL+ is well suited to portable electrical meters because it consolidates conversion, normalization, digit generation, and LCD drive into one low-power IC. A 3-1/2-digit format is useful for voltage, current, resistance, and general-purpose panel measurements where users require readable engineering resolution rather than sampled waveform data. The typical 1 pA input current can minimize disturbance of high-impedance source networks, and the device’s through-hole package supports larger instruments with serviceable boards. Protection networks, switch resistance, lead resistance, and calibration accuracy often determine final instrument performance more than the converter alone.

🖥️

Calibration and Null Detection

The ICL7126RCPL+ supports calibration and null-detection equipment because its true-polarity-at-zero characteristic preserves the sign of small input values around zero. This behavior makes it possible for an instrument to display both positive and negative deviations without ambiguous zero behavior. The dual-slope conversion also integrates the input over time, which is useful for slowly varying comparison signals and helps reject periodic noise. For accurate null measurements, use guarded input traces, low-leakage protection components, stable reference capacitors, and an appropriate conversion strategy that gives sufficient resolution at the zero point.

کورتەی بەرهەمە پێشنیارکراوەکان

ICL7107CPLZ Renesas Electronics بەکارهێنراوە لە: Digital Panel Meters, Battery-Powered Test Instruments, Laboratory Voltage Measurement, Temperature and Process Monitoring, Portable Electrical Measurement, Calibration and Null Detection TC7126RCPL Related dual-slope converter family بەکارهێنراوە لە: Digital Panel Meters, Battery-Powered Test Instruments, Laboratory Voltage Measurement, Temperature and Process Monitoring, Portable Electrical Measurement, Calibration and Null Detection
What is the ICL7126RCPL+ used for?
The ICL7126RCPL+ is a 3-1/2-digit, low-power ADC designed for panel meters, laboratory instruments, and portable measurement equipment. It combines a dual-slope converter, voltage reference, clock, seven-segment decoders, and direct LCD drivers in one 40-pin PDIP. According to the Maxim Integrated datasheet, the device supports true differential input and reference, typical 1 pA input current, and direct drive of a compatible seven-segment LCD.
Where can I download the ICL7126RCPL+ datasheet PDF?
The ICL7126RCPL+ datasheet PDF can be accessed through the manufacturer-linked documentation resources for this 3-1/2-digit converter. The available technical description identifies the device as a dual-slope, single-channel ADC with parallel word access, CMOS construction, true differential input and reference, and a 40-pin PDIP package. Use the manufacturer datasheet for the authoritative pin-description table, display connections, timing limits, and application circuit.
Where is the ICL7126RCPL+ pinout located?
The ICL7126RCPL+ pinout is located in the pin-description table of the manufacturer datasheet. The component uses a 40-pin PDIP package and integrates an ADC, voltage reference, clock, seven-segment decoders, and LCD drivers. Because the complete numbered pin list is not reproduced on this page, use the datasheet when assigning display-glass traces, reference components, analog inputs, and supply connections.
Is the ICL7126RCPL+ pin compatible with ICL7126RCPL?
The ICL7126RCPL and ICL7126RCPL+ share the same 40-pin PDIP device family and base electrical function, making ICL7126RCPL the closest documented drop-in option. The principal ordering distinction is the ICL7126RCPL+ designation, while the converter architecture, LCD-drive function, and package remain aligned. Confirm temperature grade, supply requirements, display configuration, and accuracy limits against the manufacturer datasheet before production substitution.
What can replace the ICL7126RCPL+?
The closest drop-in replacement is the ICL7126RCPL because it retains the same ICL7126 converter family, 40-pin PDIP footprint, and direct LCD-drive architecture. Other ICL7126 ordering variants can differ in temperature grade or lead-free status, so verify those parameters before installation. Devices such as the ICL7107CPLZ and TC7126RCPL offer related measurement-converter functions, but they are not automatically interchangeable because their output and display interfaces require separate verification.
What is the best Maxim Integrated equivalent for ICL7126RCPL+?
The best Maxim Integrated-family equivalent is ICL7126RCPL, which uses the same 40-pin PDIP footprint and preserves the dual-slope, 3-1/2-digit converter with direct LCD drive. It is therefore the preferred option when a second source is needed for an existing through-hole design. Final qualification should confirm the electrical ratings, operating temperature, accuracy grade, reference implementation, and display-glass pin assignments.
ICL7126RCPL+ vs ICL7107CPLZ - which converter is better?
The ICL7126RCPL+ is the better choice when direct LCD drive and true differential input and reference are required. The ICL7107CPLZ is a related 3-1/2-digit converter family with a different output arrangement, so it is not a guaranteed pin-for-pin substitute for an existing ICL7126RCPL+ PCB. The ICL7126RCPL+ remains the safer selection because its 40-pin configuration and display interface are defined by the original device family.
ICL7126RCPL+ vs TC7126RCPL - are they drop-in replacements?
The ICL7126RCPL+ and TC7126RCPL perform related 3-1/2-digit dual-slope measurement functions, but they should not be treated as automatic drop-in replacements. Cross-reference information identifies differences in main parameters and possible circuit-structure modifications, and the TC7126 family description refers to a 0.05% measurement system. Existing ICL7126RCPL+ layouts should therefore use an ICL7126-family option unless every supply, reference, timing, and LCD connection has been validated.
When should I choose the ICL7126RCPL+ over a general-purpose ADC?
Choose the ICL7126RCPL+ when the design needs a complete low-power digital panel-meter front end rather than only a sampling ADC. Its 3-1/2-digit resolution, integrated reference and clock, seven-segment decoders, LCD drivers, true differential input, and typical 1 pA input current reduce external circuitry and board area. A general-purpose ADC may offer faster sampling or a serial interface, but it requires more display-driver and signal-conditioning support.
Is the ICL7126RCPL+ suitable for high-impedance sensors?
The ICL7126RCPL+ is suitable for many high-impedance measurement circuits because its typical input current is only 1 pA and its input and reference paths are differential. Leakage through PCB contamination, long traces, protection devices, or poor input guarding can still create errors larger than the converter’s resolution. Use guarding, clean surfaces, short high-impedance routes, and the input-source impedance limits specified by the manufacturer datasheet.
How long can the ICL7126RCPL+ operate from a 9 V battery?
The Maxim Integrated datasheet describes a typical operating life of 8,000 hours from a 9 V battery under the stated operating conditions. Actual runtime depends on display load, conversion rate, supply voltage, temperature, and the selected external reference and capacitors. The 8,000-hour figure is a typical characteristic rather than a guarantee for every display size, duty cycle, or battery chemistry.
Does the ICL7126RCPL+ drive an LCD directly?
The ICL7126RCPL+ directly drives a compatible seven-segment LCD through integrated decoders and digit drivers. This removes the need for a separate display-driver IC in conventional three-1/2-digit meter designs. The display glass must match the device’s drive arrangement, and the manufacturer datasheet should be consulted for segment, common, bias, and timing connections before the PCB is released.
What are the key specifications of ICL7126RCPL+ that engineers should know?
The key ICL7126RCPL+ specifications are its 3-1/2-digit dual-slope conversion, single input channel, parallel word access, direct seven-segment LCD drive, true differential input and reference, typical 1 pA input current, and 40-pin PDIP package. The converter also includes a voltage reference and clock and offers a typical 8,000-hour operating life from a 9 V battery. These features make it particularly suitable for portable digital panel meters and laboratory instruments.
Where can I buy ICL7126RCPL+ online?
You can request a quote for the ICL7126RCPL+ through the Request a Quote form on this page. The request should identify the 40-pin PDIP package, quantity, target date, and any required inspection or documentation. Current commercial availability is handled through the quote workflow so that allocation and lead time can be confirmed for the exact ICL7126RCPL+ ordering code.
What is the price of ICL7126RCPL+?
The current commercial price for the ICL7126RCPL+ should be requested through the Request a Quote form on this page. The request should state the required quantity, 40-pin PDIP package, shipment destination, and target date. Structured pricing on the page reflects qualified quote data, while the form allows XAIPART to confirm current supply and commercial terms for the exact device.
What is the lead time and stock status for ICL7126RCPL+?
Current stock and lead time for the ICL7126RCPL+ should be confirmed through the Request a Quote form on this page. Include the required quantity and intended shipment date so the order can be matched against available inventory and production scheduling. The device is identified as an active 3-1/2-digit, 40-pin PDIP converter, but an individual order’s delivery commitment requires a current quote response.

داتای سەرچاوەی ئەندازیاری بۆ ICL7126RCPL+ — بەراوردکردن، ڕێنمایی دیزاین و زانیاری پابەندبوون.

ڕێنمایی هەڵبژاردن

Choose the ICL7126RCPL+ when the instrument needs a low-power, 3-1/2-digit measurement front end with true differential input and direct seven-segment LCD drive. It is particularly effective in panel meters, battery-powered instruments, and laboratory equipment where a readable numeric result matters more than fast sampling. Choose ICL7126RCPL when an exact-family alternative without the plus designation is acceptable after checking its qualification details. The commercial and lead-free ICL7126 family variants can be considered when their temperature and ordering requirements fit the design. Do not select ICL7107CPLZ or TC7126RCPL solely by resolution; their output and display interfaces may require PCB or firmware changes. For an existing ICL7126RCPL+ layout, prioritize the same 40-pin PDIP footprint and verify every reference, timing, and LCD connection before approving a replacement.

بەراوردکردن لەگەڵ جێگرەوەکان

پارامەتر ئەم بەرهەمە ICL7126RCPL ICL7126CPLZ ICL7126RCPLZ
Package 40-pin PDIP 40-pin PDIP 40-pin PDIP 40-pin PDIP
Brand Maxim Integrated Maxim Integrated Maxim Integrated Maxim Integrated
ADC Architecture Dual-slope Dual-slope Dual-slope Dual-slope
Resolution 3-1/2 digits 3-1/2 digits 3-1/2 digits 3-1/2 digits

جیاکەرەوە سەرەکییەکان

  • Complete panel-meter integration (بەراورد بەTC7126RCPL)
  • True differential measurement path (بەراورد بەICL7107CPLZ)
  • Direct seven-segment LCD drive (بەراورد بەICL7107CPLZ)

تێبینییەکانی دیزاین

Do not treat any related 3-1/2-digit converter as interchangeable merely because its resolution matches. The ICL7126RCPL+ includes a defined LCD-drive interface, reference arrangement, timing network, and 40-pin assignment. Compare every numbered connection with the manufacturer datasheet, particularly segment outputs, common lines, reference components, integration timing, and supply pins. The ICL7107CPLZ and TC7126RCPL are related measurement devices but require separate interface validation before substitution.

Route the analog input, reference, and timing-capacitor connections as short as practical, and keep them away from LCD drive and supply-current paths. High-impedance input nodes can collect leakage from board contamination, flux residue, and protective devices; guarding and a clean surface are therefore important. Verify source impedance and settling time against the converter timing requirements, because the typical 1 pA input current does not eliminate errors caused by external leakage.

Use the manufacturer’s specified reference and timing components with suitable voltage and temperature ratings. Dual-slope accuracy depends on the stability of both the reference and integration network, while LCD loading and conversion frequency influence supply demand. Place bypass capacitors close to the supply pins and keep the return path continuous beneath the converter. Battery-operated designs should also include a low-voltage indication or cutoff if the display must remain meaningful as the 9 V supply declines.

Design the measurement chain for the converter’s dual-slope timing rather than assuming instantaneous sampling. Allow the source and reference networks to settle between conversion cycles, and use the manufacturer’s conversion-cycle recommendations to balance resolution, noise rejection, and display refresh. For null measurements, preserve the signed result around zero and avoid input clamp leakage that could dominate when the measured voltage is close to the input’s zero-voltage reference.

زانیاری پابەندبوون

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
بێ قوڕقوشم
Unknown
بێ ھالۆجین
Unknown
کانزا ناکۆکەکان
Unknown

The plus suffix indicates a lead-free ordering option, but formal RoHS, REACH, halogen-free, and conflict-minerals status require confirmation from current manufacturer documentation. The ICL7126RCPL+ is not identified as an AEC-Q100-qualified automotive device.

داتا پشتڕاستکراوەتەوە لە: 2026-11-24 — داتا لەلایەن تیمی ئەندازیاری پێکھاتەکانی XAIPART پشتڕاستکراوەتەوە و ڕێکخراوە

گەڕانە پەیوەندیدارەکان

ICL7126RCPL+ datasheet ICL7126RCPL+ datasheet pdf ICL7126RCPL+ pinout ICL7126RCPL+ specifications ICL7126RCPL+ equivalent ICL7126RCPL+ replacement ICL7126RCPL+ cross reference ICL7126RCPL+ vs TC7126RCPL ICL7126RCPL+ vs ICL7107CPLZ ICL7126RCPL+ price ICL7126RCPL+ stock Maxim Integrated ICL7126RCPL+ ICL7126RCPL+ application circuit 3-1/2 digit dual-slope ADC 40-pin PDIP LCD ADC

پێکهاتە و زاراوە پەیوەندیدارەکان

Maxim Integrated ICL7126RCPL+ ICL7126RCPL ICL7126CPLZ ICL7126RCPLZ ICL7107CPLZ TC7126RCPL 3-1/2-digit ADC dual-slope ADC analog-to-digital converter integrated circuit semiconductor direct LCD drive seven-segment decoder parallel word access true differential input voltage reference PDIP-40 surface-mount package hierarchy through-hole package panel meter battery-powered instrumentation high-impedance measurement input leakage dual-slope integration
داواکاری نرخی خێرا RFQ
وردەکارییەکانی تەواو پڕ بکەرەوە — تیمی فرۆشتنی ئێمە لە ماوەی 24 کاتژمێردا وەڵام دەداتەوە
ژمارەی پارچە بەرهەمهێنەر پاکەت QTY نرخی ئامانج کۆی گشتی
✓
نرخەکە نێردرا!

لە ماوەی ٢٤ کاتژمێردا وەڵامی ئیمەیڵەکەت دەدەینەوە

1
داواکاری نرخ پێشکەشکرا
2
نرخپێدان وەرگیرا
3
داواکاری دانرا
4
پارەدان
5
نێردرا
6
گەیەنراوە
بینینی وردەکاریی داواکاری نرخ