LAN91C111-NE - 10/100 Ethernet MAC + PHY | Microchip
MPN: LAN91C111-NE ✓ چالاکLAN91C111-NE گشتی
An Ethernet MAC and PHY combined on one IC form the interface between an embedded host processor and a physical copper network. The MAC manages frame processing, addressing, collision handling, and data movement, while the PHY converts logical data into signals that can be transmitted over twisted-pair Ethernet. Integrating both functions reduces external component count and simplifies PCB routing compared with a separated MAC and transceiver design.
The LAN91C111 family provides dual-speed 10/100 Mbps connectivity, AutoNegotiation, burst data transfer, and selectable host-bus widths. Its 8 KB internal FIFO buffer separates host processing from Ethernet timing, helping manage burst traffic on embedded processor buses. The flexible 8-, 16-, or 32-bit host interface allows the same controller architecture to address systems with different data-bus capabilities.
The controller implements the MAC and PHY portions of the CSMA/CD protocol. Its receive path aligns scrambled data to IEEE 802.3 5B word boundaries, descrambles the recovered data, and transfers it to the 4B/5B decoder. On the transmit side, the integrated Ethernet engine prepares frames for the physical layer while the internal FIFOs buffer host and network traffic. This architecture supports both 10 Mbps and 100 Mbps links without requiring a separate Ethernet interface controller.
Typical uses include embedded industrial controllers, factory automation equipment, embedded Web servers, set-top boxes, print systems, and network-connected embedded products. It is particularly useful where a host processor needs compact 10/100 Ethernet connectivity without a PCI bus or a separate physical-layer transceiver. The selectable host width also helps optimize external bus wiring and processor interface overhead.
PCB design should preserve short, controlled impedance Ethernet traces and provide the external magnetic-interface components required by the application circuitry. Place the controller and supporting clock, decoupling, and interface components according to the manufacturer datasheet layout. Check the host-bus voltage, reset requirements, interrupt connections, and FIFO configuration in firmware before finalizing the system interface.
This page combines the manufacturer architecture description with practical interface guidance, verified MPN comparison points, and implementation-oriented design notes. It is structured to help engineers identify the correct LAN91C111 ordering variant, plan the host interface, and evaluate the controller for compact embedded Ethernet designs.
جێگرەوەکانی جێگۆڕکێ بۆ LAN91C111-NE — هەمان پاکەت، پین بە پین گونجاو. ئەو بەشانەی پاکەتی جیاوازیان هەیە و پێویستیان بە چاککردنەوەی PCB هەیە لابراون.
جۆرەکان لەم زنجیرەیەدا
مۆدێلەکانی هەمان زنجیرە کە بە شێوەی ڕاستەوخۆ گونجاون لەگەڵ LAN91C111-NE (هەمان شێوە و پێکهاتەی شوێن) — جیاوازە لە Internal FIFO Memory, Network Standard.
LAN91C111I-NU
✅ جێگرەوەی ڕاستەوخۆ📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)
LAN91C111I-NS
✅ جێگرەوەی ڕاستەوخۆ📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)
LAN91C111-NU
✅ جێگرەوەی ڕاستەوخۆپەیوەندی بۆ نرخ
بینینی داتاشیت →LAN91C111-NE تایبەتمەندییەکان
| Product Type | 10/100 Ethernet single-chip MAC and PHY |
| Ethernet Speed | 10 Mbps and 100 Mbps |
| Host Interface Width | 8-bit, 16-bit, or 32-bit |
| Integrated Functions | Ethernet MAC and Ethernet PHY |
| Internal FIFO Memory | 8 KB dynamically configurable TX/RX |
| Duplex Support | Full duplex |
| Network Standard | IEEE 802.3 |
| Media Access Method | CSMA/CD |
| AutoNegotiation | Supported |
| Data Transfer | Burst data transfer |
| Device Architecture | Mixed-signal Analog/Digital |
| Host Bus Type | Non-PCI parallel host interface |
ڕێنمایی ڕێکخستنی پینی LAN91C111-NE standard
ڕێکخستنی پین بۆ LAN91C111-NE (پاکێجی standard). ژمارەدانی پین، فەنکشنەکان و نەخشەکانی پەیوەندی لە داتاشیتی بەرھەمھێنەردا پێناسە کراون. سەرنجی بدە بۆ شوێنپێی ورد و ڕێنمایییەکانی لەحیمکردن.
هیچ داتای وردی پینئاوت بەردەست نییە بۆ LAN91C111-NE.
سەرنج بدە بە داتاشیت بۆ ڕێکخستنی تەواوی پینەکان.
بەکارهێنانە باوەکان
LAN91C111-NE گونجاوە بۆ 6 بەکارھێنانs: Embedded Industrial Automation Controller, Embedded Web Server, Factory Data Acquisition Terminal, Network-Connected Printer Controller, Set-Top Box Network Port, IoT Gateway with Legacy Host Interface.
Embedded Industrial Automation Controller
The LAN91C111-NE is appropriate for an embedded automation controller that must exchange real-time status and command data over a 10/100 Ethernet network. Its selectable 8-bit, 16-bit, or 32-bit host bus lets the design match the controller processor while minimizing unnecessary external signals, and the 8 KB dynamically configurable FIFO separates burst traffic from host processing. AutoNegotiation allows the controller to operate with 10 Mbps or 100 Mbps network equipment. For factory equipment, verify the exact ordering variant's temperature and lifecycle status, then isolate Ethernet transients and route controlled-impedance traces according to the manufacturer layout guidance.
پێشنیارکراو
Embedded Web Server
The LAN91C111-NE can provide the physical Ethernet connection for a compact embedded Web server running on an 8-bit, 16-bit, or 32-bit host processor. At 10 Mbps and 100 Mbps, the controller supports conventional Fast Ethernet networks, while AutoNegotiation selects the link rate and full-duplex operation. The 8 KB transmit and receive FIFO helps the server handle request bursts without requiring a PCI bus. Firmware should configure the selected host width, interrupt behavior, receive buffer boundaries, and address filtering before the server exposes its network interface.
پێشنیارکراو
Factory Data Acquisition Terminal
The LAN91C111-NE is well suited to a factory data-acquisition terminal that sends sensor records and receives configuration commands over Fast Ethernet. Its 8 KB dynamically configurable TX/RX FIFO supports burst data transfer, while the adjustable host-bus width can accommodate processors with different external data-bus capabilities. The integrated MAC and PHY reduces the component count compared with separate Ethernet implementations. To preserve data integrity, synchronize packet handling with the appropriate interrupts, size software buffers for the expected traffic pattern, and keep copper-interface routing away from high-energy switching nodes.
پێشنیارکراو
Network-Connected Printer Controller
The LAN91C111-NE offers a compact interface for a printer controller that needs 10/100 Ethernet without a separate PCI network card. The controller handles the Ethernet MAC and PHY functions at 10 Mbps and 100 Mbps and provides a selectable parallel host interface for the embedded print engine processor. Its 8 KB FIFO supports burst-oriented traffic associated with print jobs and management packets. The implementation should reserve suitable RAM for protocol buffers, manage flow control carefully during large transfers, and validate the host timing, reset sequence, and interrupt setup against the manufacturer datasheet.
پێشنیارکراو
Set-Top Box Network Port
The LAN91C111-NE can serve as the 10/100 Ethernet connection for a set-top box or similar multimedia terminal. AutoNegotiation and full-duplex support allow the device to connect across common Fast Ethernet infrastructure, while the 8 KB FIFO handles burst transfers generated by streaming services, control messages, and software updates. The selectable 8-, 16-, or 32-bit host interface offers flexibility when integrating with the main processor. Software should maintain consistent FIFO allocation under sustained traffic and use the interrupt scheme that best matches the platform's real-time requirements.
پێشنیارکراو
IoT Gateway with Legacy Host Interface
The LAN91C111-NE is appropriate for an IoT gateway that connects an embedded supervisory processor to a Fast Ethernet backbone. The 8-bit host mode can reduce interface wiring when throughput requirements are modest, while 16-bit and 32-bit modes provide greater bandwidth for aggregation and uplink traffic. Its integrated MAC and PHY, AutoNegotiation, and 8 KB FIFO support a compact gateway implementation. The gateway firmware should separate real-time Ethernet servicing from application tasks, monitor buffer occupancy under traffic bursts, and confirm the selected package and suffix before release to production.
پێشنیارکراو
کورتەی بەرهەمە پێشنیارکراوەکان
داتای سەرچاوەی ئەندازیاری بۆ LAN91C111-NE — بەراوردکردن، ڕێنمایی دیزاین و زانیاری پابەندبوون.
ڕێنمایی هەڵبژاردن
بەراوردکردن لەگەڵ جێگرەوەکان
| پارامەتر | ئەم بەرهەمە | LAN91C111I-NU | LAN91C111I-NS | LAN91C111-NU |
|---|---|---|---|---|
| Brand | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology |
| Package | TQFP-128 (14 x 14 mm) | TQFP-128 (14 x 14 mm) | TQFP-128 (14 x 14 mm) | TQFP-128 (14 x 14 mm) |
| Ethernet Speed | 10 Mbps and 100 Mbps | 10 Mbps and 100 Mbps | 10 Mbps and 100 Mbps | 10 Mbps and 100 Mbps |
| Integrated Functions | MAC and PHY | MAC and PHY | MAC and PHY | MAC and PHY |
| Host Interface Width | 8-bit, 16-bit, or 32-bit | 8-bit, 16-bit, or 32-bit | 8-bit, 16-bit, or 32-bit | 8-bit, 16-bit, or 32-bit |
| Internal FIFO Memory | 8 KB | 8 KB | 8 KB | 8 KB |
| AutoNegotiation | Supported | Supported | Supported | Supported |
| Duplex Mode | Full duplex | Full duplex | Full duplex | Full duplex |
| Host Bus Type | Non-PCI parallel interface | Non-PCI parallel interface | Non-PCI parallel interface | Non-PCI parallel interface |
| Ordering Qualification | Commercial LAN91C111-NE ordering option | I-NU ordering option | I-NS ordering option | NU ordering option |
جیاکەرەوە سەرەکییەکان
- Combines the Ethernet MAC and PHY in one controller (بەراورد بەLAN91C111I-NU)
- Supports three parallel host-bus widths (بەراورد بەLAN91C111I-NS)
- Provides 8 KB of dynamically configurable FIFO memory (بەراورد بەLAN91C111-NU)
تێبینییەکانی دیزاین
Use the manufacturer pin-description table and layout example before assigning Ethernet or host-bus lands. The LAN91C111 combines mixed-signal PHY circuitry with a high-speed parallel host interface, so keep the clock and data routes short, route the host bus consistently, and place required bypass capacitors close to their specified pins. Do not derive the target footprint solely from a family member: verify that the exact -NE ordering code uses the same mechanical drawing and pin numbering.
Plan the copper interface section as a controlled-impedance Ethernet region and keep it isolated from noisy switching circuitry. Follow the reference layout in the official LAN91C111 datasheet for the PHY, magnetic-interface components, clock source, and grounding arrangement. The 8-, 16-, and 32-bit host width changes signal count and routing pressure, so choose the narrowest mode that satisfies host throughput and packet-service latency requirements.
Configure software and hardware consistently for host width, buffer allocation, address filtering, reset, interrupts, and AutoNegotiation before diagnosing a network failure. The controller supports 10 Mbps and 100 Mbps and full-duplex switched Ethernet, but incorrect FIFO management or interrupt assumptions can still reduce effective throughput. When comparing ordering suffixes, confirm package, temperature grade, qualification, and lifecycle status rather than treating the I, N, E, or S characters as interchangeable packaging details.
زانیاری پابەندبوون
Compliance status was not explicitly identified in the manufacturer or distributor product information used for this page. The industrial or automotive classification of the I-series ordering option should not be inferred from the suffix alone; confirm the official ordering information for the exact MPN.