LAN9215I-MT - 10/100 Ethernet Controller | Microchip
MPN: LAN9215I-MT ✓ چالاکLAN9215I-MT گشتی
An Ethernet controller is an interface integrated circuit that connects an embedded processor or programmable logic device to an Ethernet physical layer. In this case, the hierarchy is Ethernet controller > network interface controller > interface IC > semiconductor. Combining the controller and PHY reduces external component count, but the LAN9215I-MT still requires an Ethernet magnetics and connector implementation as well as a suitable 16-bit host bus connection.
Verified features include a 16-bit MII interface, HP Auto-MDIX support, interrupt generation, 3.3 V operation with wake-up functionality, non-volatile configuration storage, and power-up or reset configuration. These capabilities suit designs requiring controlled Ethernet startup, host interrupt handling, and flexible configuration retention. The controller architecture is described as efficient, with low CPU overhead for medium-performance embedded applications.
The LAN9215I-MT supports 10/100 Mb/s Ethernet connectivity, allowing equipment to participate in 10 Mb/s or 100 Mb/s networks. Its integrated controller and PHY simplify the signal chain compared with a discrete Ethernet MAC and separate PHY. The parallel MII interface remains important for embedded processors that do not include an integrated Ethernet MAC and need a conventional external data bus rather than a serial peripheral interface.
Typical uses include industrial control equipment, factory automation controllers, embedded gateways, instrumentation, and network-enabled data acquisition systems. In these applications, the MII interface can connect to a host processor, the Auto-MDIX function can simplify straight-through or crossover cable handling, and configuration storage can reduce firmware initialization work. Wake-up and interrupt support also benefit systems that need controlled network activity and event-driven host processing.
Designers should follow the manufacturer's TQFP placement checklist, particularly the 49.9 ohm TX termination pull-up arrangement specified for TPO+ when Auto-MDIX is enabled. Confirm the complete package pin assignment, power rails, decoupling requirements, magnetics selection, reference schematic, and PCB constraints against the manufacturer datasheet before releasing a layout.
This page consolidates verified manufacturer and distributor information, transparent data gaps, drop-in replacement evidence, and application-focused design guidance. It distinguishes confirmed electrical and packaging facts from unverified details that still require validation against the official LAN9215I documentation.
جێگرەوەکانی جێگۆڕکێ بۆ LAN9215I-MT — هەمان پاکەت، پین بە پین گونجاو. ئەو بەشانەی پاکەتی جیاوازیان هەیە و پێویستیان بە چاککردنەوەی PCB هەیە لابراون.
جۆرەکان لەم زنجیرەیەدا
مۆدێلەکانی هەمان زنجیرە کە بە شێوەی ڕاستەوخۆ گونجاون لەگەڵ LAN9215I-MT (هەمان شێوە و پێکهاتەی شوێن) — جیاوازە لە Host Interface, Package, Auto-MDIX, Device Type, Ethernet Speed.
LAN9215-MT
✅ جێگرەوەی ڕاستەوخۆپەیوەندی بۆ نرخ
بینینی داتاشیت →LAN9215I-MT تایبەتمەندییەکان
| Device Type | 10/100 Ethernet controller with integrated PHY |
| Ethernet Speed | 10 Mb/s or 100 Mb/s |
| Host Interface | 16-bit parallel MII |
| PHY Standard | 10/100 Base-T/TX |
| ڤۆڵتیەی دابینکردن | 1.8 V |
| Operating Voltage | 3.3 V |
| پلەی گەرمیی کارکردن | 0 °C to +70 °C |
| پاکێج | 100-pin TQFP, 14 x 14 mm |
| جۆری دامەزراندن | Surface mount |
| Auto-MDIX | Supported, including HP Auto-MDIX |
| Interrupt Generation | Supported |
| Wake-up Function | Supported |
| Configuration Storage | Non-volatile configuration storage |
| Power-up Configuration | Power-up and reset configuration supported |
| CPU Overhead | Low, as described by the manufacturer |
| دۆخی RoHS | RoHS compliant |
| TX Termination Resistor | 49.9 Ω pull-up on TPO+ |
| ژمارەی پین | 100 pins |
ڕێنمایی ڕێکخستنی پینی LAN9215I-MT 100-pin tqfp, 14 x 14 mm
ڕێکخستنی پین بۆ LAN9215I-MT (پاکێجی 100-pin tqfp, 14 x 14 mm). ژمارەدانی پین، فەنکشنەکان و نەخشەکانی پەیوەندی لە داتاشیتی بەرھەمھێنەردا پێناسە کراون. سەرنجی بدە بۆ شوێنپێی ورد و ڕێنمایییەکانی لەحیمکردن.
هیچ داتای وردی پینئاوت بەردەست نییە بۆ LAN9215I-MT.
سەرنج بدە بە داتاشیت بۆ ڕێکخستنی تەواوی پینەکان.
بەکارهێنانە باوەکان
LAN9215I-MT گونجاوە بۆ 6 بەکارھێنانs: Industrial Ethernet Control, Factory Automation Gateway, Embedded Network Gateway, Data Acquisition System, Networked Instrumentation, Power-Aware Embedded Product.
Industrial Ethernet Control
The LAN9215I-MT fits an embedded industrial controller that needs 10/100 Mb/s Ethernet without a separate MAC and PHY. Its integrated 10/100 Base-T/TX interface reduces the component count, while the 16-bit MII bus connects the controller to a host processor. HP Auto-MDIX can simplify physical-cable handling, and interrupt generation allows the host to process link and packet events without continuous polling. The verified 0 °C to +70 °C range is suitable for many indoor control applications, but extended-temperature requirements must be checked against the official datasheet. Ethernet magnetics, surge protection, grounding, and connector layout remain part of the complete interface implementation.
پێشنیارکراو
Factory Automation Gateway
The LAN9215I-MT can provide the network-facing Ethernet block in a factory gateway while a separate host processor manages protocols and local I/O. Its verified 100 Mb/s capability is appropriate for supervisory traffic, configuration access, diagnostics, and controller-to-controller communication. The 16-bit parallel MII interface supports straightforward connection to processors with external bus resources, and low CPU overhead is valuable when the gateway must preserve real-time performance. Wake-up support can assist power-managed products, while interrupt generation provides event-driven handling. Industrial qualification, isolation, Ethernet magnetics, and EMC design must be validated separately for the deployed environment.
پێشنیارکراو
Embedded Network Gateway
The LAN9215I-MT is appropriate for a compact gateway that converts an embedded host interface into 10/100 Ethernet. Combining the Ethernet controller and PHY reduces board area and external PHY complexity, while the parallel MII interface gives the host processor a deterministic external bus connection. At 100 Mb/s, the verified device supports common management, telemetry, and configuration traffic. Interrupt-driven operation can lower unnecessary host processing, and non-volatile configuration storage can support persistent link or interface settings. The implementation still requires a properly designed magnetic interface and must comply with the manufacturer’s reference schematic and component-placement checklist.
پێشنیارکراو
Data Acquisition System
The LAN9215I-MT can connect an embedded data-acquisition controller to an Ethernet LAN for centralized monitoring and configuration. The 16-bit MII interface provides a direct parallel connection to suitable host processors, and the integrated 10/100 Base-T/TX PHY eliminates a separate Ethernet PHY from the board. Interrupt generation supports event-driven packet processing, while the low-CPU-overhead architecture helps preserve measurement-system performance. HP Auto-MDIX improves installation flexibility in lab and industrial settings. Designers should use the official reference schematic and TQFP placement checklist, particularly the 49.9 Ω TPO+ pull-up placement guidance, to avoid signal-integrity and EMC issues.
پێشنیارکراو
Networked Instrumentation
The LAN9215I-MT can add Ethernet connectivity to a programmable instrument that already exposes a parallel host interface. Its verified 10/100 Mb/s support is suitable for remote commands, measurement data transfer, status monitoring, and configuration workflows. The integrated controller and PHY simplify the hardware stack, and the MII interface avoids requiring an Ethernet-capable MCU with an integrated MAC. Interrupt support can trigger host processing when network activity occurs. The exact reset, clock, power, and configuration requirements must be implemented according to the manufacturer datasheet, and the Ethernet channel should include the recommended magnetics, termination arrangement, controlled return path, and isolation strategy appropriate to the instrument.
پێشنیارکراو
Power-Aware Embedded Product
The LAN9215I-MT is useful in embedded products that need Ethernet connectivity and controlled low-power behavior. The verified wake-up function allows a host system to activate or manage network activity, while interrupt generation avoids requiring continuous software polling. At 10/100 Mb/s, the controller supports common product-management and update traffic without the complexity of a higher-speed interface. Its 16-bit MII host connection can serve processors with limited peripheral resources. Power-consumption figures were not present in the supplied verified data, so power budgeting must use the manufacturer datasheet and measured operating modes. Wake pins, clock behavior, and supply sequencing should not be inferred beyond the confirmed feature.
پێشنیارکراو
کورتەی بەرهەمە پێشنیارکراوەکان
داتای سەرچاوەی ئەندازیاری بۆ LAN9215I-MT — بەراوردکردن، ڕێنمایی دیزاین و زانیاری پابەندبوون.
ڕێنمایی هەڵبژاردن
بەراوردکردن لەگەڵ جێگرەوەکان
| پارامەتر | ئەم بەرهەمە | LAN9215-MT |
|---|---|---|
| Package | TQFP-100 (14 x 14 mm) | TQFP-100 (14 x 14 mm) |
| Brand | Microchip Technology | Microchip Technology |
| Device Type | 10/100 Ethernet controller with integrated PHY | 10/100 Ethernet controller with integrated PHY |
| Ethernet Speed | 10 Mb/s and 100 Mb/s | 100 Mb/s |
جیاکەرەوە سەرەکییەکان
- Single-chip Ethernet integration (بەراورد بەLAN9215-MT)
- Host-bus connectivity (بەراورد بەLAN9215-MT)
- Installation flexibility (بەراورد بەLAN9215-MT)
تێبینییەکانی دیزاین
Follow Microchip's LAN9215I 100-pin TQFP placement checklist. When Auto-MDIX is enabled, place the 49.9 Ω TX termination pull-up for TPO+ as close as practical to the LAN9215I; when Auto-MDIX is disabled, place it as close as possible to the magnetics. Use the manufacturer reference schematic for decoupling and power-plane geometry, and maintain the documented pin and exposed-pad requirements where applicable.
Treat the MII bus as a timing-sensitive parallel interface. Route it with a consistent reference plane, minimize stubs, avoid unnecessary test-point geometry, and keep the controller and PHY interface area away from noisy switching nodes. The supplied evidence does not provide rise-time, trace-length, impedance, or timing values, so these requirements must be taken from the official datasheet and interface guidelines rather than guessed.
Do not assume that the similar LAN9215-MT ordering code is electrically identical. The verified comparison states that the devices have some differing electrical characteristics even though their general function and several parameters are consistent. Before substitution, compare every TQFP signal, supply rail, timing parameter, reset state, enable or configuration method, interrupt behavior, and non-volatile configuration process against the official manufacturer datasheets.
The Ethernet magnetics and connector interface require a controlled return path and careful separation from noisy power and digital switching areas. Apply the manufacturer's reference layout and verify isolation, surge protection, and chassis-ground strategy for the target installation. The verified placement checklist specifically identifies the TPO+ pull-up location, making that termination placement an important EMC and signal-integrity checkpoint rather than an optional optimization.
زانیاری پابەندبوون
RoHS-compliant package information is present in the verified results. The supplied data does not explicitly establish REACH, lead-free, halogen-free, conflict-minerals, or automotive qualification status; AEC-Q100 is not applicable because this is a commercial Ethernet controller rather than an automotive-qualified device.