LAN9254-I/JRX - 3-Port EtherCAT Controller | Microchip
MPN: LAN9254-I/JRX ✓ چالاکLAN9254-I/JRX گشتی
An EtherCAT device controller, or ESC, is a specialized interface IC that connects an EtherCAT master and distributed automation equipment to an embedded application processor. Within the product hierarchy, the LAN9254-I/JRX is an EtherCAT controller, a network interface controller, and an industrial Ethernet interface IC. Integrating two Ethernet PHYs into the controller reduces the number of external network components required by a multi-port EtherCAT slave design.
The LAN9254-I/JRX provides three EtherCAT ports, two integrated full-duplex 100BASE-TX transceivers, and 32 digital I/Os. HP Auto-MDIX allows direct or crossover LAN cable connections without manually assigning transmit and receive pairs. The 1.8 V to 3.3 V operating range supports integration between low-voltage digital logic and industrial communication networks, while the exposed-pad package supports heat transfer from the controller.
Its integrated EtherCAT functionality is designed for deterministic industrial communication. Distributed Clocks support synchronized real-time networks, while the two independent Ethernet channels support line and ring topologies common in industrial automation. The controller also includes wake-up functionality, power-up and reset configuration, non-volatile configuration storage, and interrupt generation for coordinated host-processor communication.
Typical uses include EtherCAT servo drives, programmable logic controllers, industrial I/O modules, motion controllers, robotics equipment, and factory automation gateways. The 32 digital I/Os can expose application-level status, enables, faults, and digital signals without requiring a separate large I/O expander. Integrated PHYs also simplify board routing while retaining dedicated Ethernet connectivity for downstream EtherCAT ports.
For a new design, follow the LAN9254 Hardware Design Checklist and the pin-description table in the manufacturer datasheet when assigning the 80-pin footprint. Check power sequencing, exposed-pad connection, configuration straps, PHY magnetics, termination, and layout against the hardware checklist before fabrication. The checklist specifically calls for verifying every pin against the datasheet and the 80-pin TQFP shape.
This page organizes the controller's Ethernet, EtherCAT, digital I/O, packaging, and sourcing information while adding practical design guidance. It also distinguishes the temperature-grade and packaging variants that engineers encounter when planning a second-source or lifecycle strategy.
جێگرەوەکانی جێگۆڕکێ بۆ LAN9254-I/JRX — هەمان پاکەت، پین بە پین گونجاو. ئەو بەشانەی پاکەتی جیاوازیان هەیە و پێویستیان بە چاککردنەوەی PCB هەیە لابراون.
جۆرەکان لەم زنجیرەیەدا
مۆدێلەکانی هەمان زنجیرە کە بە شێوەی ڕاستەوخۆ گونجاون لەگەڵ LAN9254-I/JRX (هەمان شێوە و پێکهاتەی شوێن) — جیاوازە لە Digital I/O Count, Ethernet Speed, Mounting Type, Ethernet Physical Layer, Package.
LAN9254/JRX
✅ جێگرەوەی ڕاستەوخۆپەیوەندی بۆ نرخ
بینینی داتاشیت →LAN9254-I/JRX تایبەتمەندییەکان
| Product Type | 3-port EtherCAT device controller |
| EtherCAT Port Count | 3 ports |
| Integrated Ethernet PHY Count | 2 PHYs |
| Ethernet Speed | 100 Mbit/s |
| Ethernet Standard | 10/100BASE-TX |
| Duplex Operation | Full duplex |
| Digital I/O Count | 32 digital I/Os |
| Supply Voltage Range | 1.8 V to 3.3 V |
| Auto-MDIX Support | HP Auto-MDIX, 1 mode |
| Real-Time Clock Function | Distributed Clocks, 1 supported function |
| Wake-Up Function | Yes, 1 function |
| Configuration Features | Power-up and reset configuration, 2 functions |
| Configuration Storage | Non-volatile configuration storage, 1 function |
| Interrupt Support | Interrupt generation, 1 function |
| Package Pin Count | 80 pins |
| Package Type | 80-pin TQFP exposed pad |
| Package Body Size | 12 mm x 12 mm |
| جۆری دامەزراندن | Surface mount, 1 mounting method |
| RoHS Compliance | Unknown |
ڕێنمایی ڕێکخستنی پینی LAN9254-I/JRX 12 mm x 12 mm
ڕێکخستنی پین بۆ LAN9254-I/JRX (پاکێجی 12 mm x 12 mm). ژمارەدانی پین، فەنکشنەکان و نەخشەکانی پەیوەندی لە داتاشیتی بەرھەمھێنەردا پێناسە کراون. سەرنجی بدە بۆ شوێنپێی ورد و ڕێنمایییەکانی لەحیمکردن.
هیچ داتای وردی پینئاوت بەردەست نییە بۆ LAN9254-I/JRX.
سەرنج بدە بە داتاشیت بۆ ڕێکخستنی تەواوی پینەکان.
بەکارهێنانە باوەکان
LAN9254-I/JRX گونجاوە بۆ 6 بەکارھێنانs: EtherCAT Servo Drives, Industrial PLC I/O Modules, Industrial Robotics Controllers, Motion and Machine Control, Factory Automation Gateways, Distributed Digital I/O.
EtherCAT Servo Drives
The LAN9254-I/JRX fits a servo-drive slave controller because it combines 3 EtherCAT ports, two integrated 100BASE-TX PHYs, and 32 digital I/Os in one 80-pin TQFP device. The controller handles EtherCAT communication while the host processor performs motion control and current-loop functions. Its 1.8 V to 3.3 V operating range supports low-voltage digital logic, and the exposed-pad package provides a direct thermal path into the PCB. Engineers should follow the manufacturer hardware checklist for PHY magnetics, supply routing, configuration straps, and exposed-pad layout.
پێشنیارکراو
Industrial PLC I/O Modules
A distributed PLC I/O module can use the LAN9254-I/JRX to combine EtherCAT connectivity with local digital signaling. Its 32 digital I/Os can support module status, channel enables, fault flags, and other application-level signals, while the 3-port architecture supports redundant or branched fieldbus arrangements. Two integrated full-duplex 100BASE-TX PHYs reduce the external network interface burden. The device operates from 1.8 V to 3.3 V, making it suitable for modern embedded control systems, subject to isolation, EMC, and environmental requirements.
پێشنیارکراو
Industrial Robotics Controllers
The LAN9254-I/JRX is appropriate for robot controllers that exchange deterministic commands and state over EtherCAT. Its two integrated 100BASE-TX PHYs support 100 Mbit/s full-duplex links without requiring separate Ethernet PHY devices, and HP Auto-MDIX simplifies connections using either direct or crossover cables. The 32 digital I/Os can handle auxiliary machine functions such as safety, tooling, and digital feedback. Distributed Clocks support synchronized EtherCAT operation, while the compact 12 mm by 12 mm TQFP package preserves routing flexibility on controller boards.
پێشنیارکراو
Motion and Machine Control
In a motion-control or machine-control design, the LAN9254-I/JRX can serve as the EtherCAT communication engine while a real-time processor executes sequencing and control algorithms. The 3-port architecture accommodates upstream, downstream, and branch connections, and the two integrated PHYs provide full-duplex 100BASE-TX operation at each physical network interface. The 32 digital I/Os provide a direct interface for discrete machine signals. Use the datasheet pin table and hardware checklist to establish supply sequencing, termination, magnetics, and exposed-pad connections.
پێشنیارکراو
Factory Automation Gateways
The LAN9254-I/JRX can support factory gateways that bridge EtherCAT to embedded control logic or supervisory data acquisition hardware. Integrated dual PHYs reduce component count and board area, while the three available EtherCAT ports support line, ring, or branch network arrangements. Its 32 digital I/Os can provide discrete status and control signaling outside the main communication processor. The 1.8 V to 3.3 V supply range supports integration with common embedded systems. Industrial deployments must still address EMC isolation, environmental qualification, connector protection, and network cable compliance.
پێشنیارکراو
Distributed Digital I/O
The LAN9254-I/JRX is well suited to distributed digital I/O because it provides both EtherCAT communication and 32 local digital I/Os. A remote I/O station can use those I/Os for input sensing, actuator control, and module-status signaling while the integrated Ethernet PHYs connect the module to the EtherCAT network. HP Auto-MDIX improves installation flexibility by supporting direct and crossover cables. The controller's 80-pin TQFP exposed-pad package and 1.8 V to 3.3 V operating range support compact, low-voltage industrial boards, with final protection and isolation implemented around the external I/O circuitry.
پێشنیارکراو
کورتەی بەرهەمە پێشنیارکراوەکان
داتای سەرچاوەی ئەندازیاری بۆ LAN9254-I/JRX — بەراوردکردن، ڕێنمایی دیزاین و زانیاری پابەندبوون.
ڕێنمایی هەڵبژاردن
بەراوردکردن لەگەڵ جێگرەوەکان
| پارامەتر | ئەم بەرهەمە | LAN9254/JRX |
|---|---|---|
| Package | 80-TQFP-EP (12x12) | 80-TQFP-EP (12x12) |
| Brand | Microchip Technology | Microchip Technology |
| EtherCAT Port Count | 3 ports | 3 ports |
| Integrated PHY Count | 2 PHYs | 2 PHYs |
| Ethernet Speed | 100 Mbit/s | 100 Mbit/s |
| Digital I/O Count | 32 digital I/Os | 32 digital I/Os |
| Supply Voltage Range | 1.8 V to 3.3 V | 1.8 V to 3.3 V |
| Temperature Designation | Industrial -I designation | Base designation without -I |
| Auto-MDIX | HP Auto-MDIX | HP Auto-MDIX |
| Real-Time Feature | Distributed Clocks | Distributed Clocks |
جیاکەرەوە سەرەکییەکان
- Integrated dual-PHY EtherCAT controller (بەراورد بەLAN9353T/ML)
- Same controller family with industrial ordering suffix (بەراورد بەLAN9254/JRX)
- Direct digital I/O integration (بەراورد بەLAN9353T/PT)
تێبینییەکانی دیزاین
Use the LAN9254 Hardware Design Checklist before releasing the PCB. Verify every one of the 80 pins against the manufacturer datasheet, confirm the 12 mm by 12 mm TQFP outline, connect the exposed pad as directed, and check configuration straps against the power-up and reset requirements. Place input and output decoupling capacitors at their associated supply pins and keep sensitive configuration and clock routes away from Ethernet magnetics and high-current switching nodes.
Plan the 100BASE-TX channels as controlled-impedance Ethernet interfaces. Follow the recommended transformer, center-tap, termination, and routing guidance in the datasheet, and keep each PHY channel physically separated from digital clocks, high-speed memory buses, and switching power stages. Use HP Auto-MDIX for cable flexibility, but do not allow it to replace correct pair assignment or board-level Ethernet layout practice. Validate magnetics and channel performance with the manufacturer-recommended test setup.
Confirm the 1.8 V to 3.3 V operating range against the controller's individual supply pins and the host system voltage plan. The product page does not provide the complete rail allocation, so use the pin-description and electrical-characteristics tables for final connections. Decouple each supply domain at its package pins, provide adequate source current for the PHY and digital loads, and analyze the exposed-pad thermal path when the controller operates continuously at elevated ambient temperature.
Do not substitute an ESC solely because it also supports EtherCAT. The LAN9353T/ML and LAN9353T/PT belong to the same manufacturer family but are not established as pin-to-pin replacements for the LAN9254-I/JRX. A migration requires checking the process-data interface, PDI timing, register map, digital I/O count, PHY arrangement, supply rails, package geometry, and boot configuration. The AN3621 migration guide is useful for understanding LAN9254-family design differences, but it should not be treated as evidence of interchangeability.
زانیاری پابەندبوون
The manufacturer product information identifies an industrial-temperature controller but does not state the requested compliance declarations. RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals status must be confirmed from the current manufacturer product documentation before release.