MAX133EPL+ - 3-3/4 Digit DMM A/D Converter, 40-Pin PDIP | Maxim Integrated
MPN: MAX133EPL+ ✓ چالاکMAX133EPL+ گشتی
What is a DMM A/D converter? A DMM A/D converter is a dedicated integrating (dual-slope) analog-to-digital converter optimized for panel-meter and digital-multimeter instrumentation rather than general-purpose signal acquisition. It sits in the hierarchy of ADC > integrating ADC > data-acquisition converter > data-converter IC, and is paired with a display driver so that a front panel can show a numeric reading directly without a host microcontroller having to multiplex the LED digits.
Key features of the MAX133 include +/-40,000-count internal resolution with a 4000-count displayed reading, a guard digit that allows autozero or tare to be performed to one-tenth of a displayed count, and a 50 ms conversion time suitable for continuously refreshed panel meters. The device is a single-channel converter with differential-capable measurement inputs and is offered in an industrial temperature grade in a through-hole PDIP-40 package.
Technically, the MAX133 integrates a proprietary-method integrating ADC rather than a successive-approximation or sigma-delta architecture, which inherently rejects periodic noise from mains-derived supplies and provides good averaging behaviour for slowly changing inputs. The internal resolution exceeds the displayed digit count because the extra guard digit is used for autozero and tare correction rather than for extra display digits, improving measurement accuracy without complicating the display.
Typical applications include digital panel meters, handheld and bench multimeters, data loggers, weigh scales, and industrial process monitoring instruments where a stable, readable numeric display is required. Because the MAX133 drives the display segments and digit commons directly, the instrument designer can build a meter front end with very few external components and no microcontroller in the measurement path.
A key design consideration is that the MAX133 family is a mature, through-hole instrument-circuit family rather than a high-speed converter; design effort should focus on analog input conditioning, reference selection, and display multiplexing rather than on sampling-rate limitations. For new designs needing more resolution, more channels, or faster conversion, modern sigma-delta or SAR converters plus a separate display driver may be a better architectural fit.
This page consolidates distributor pricing, verified drop-in alternatives from the same MAX family, and practical design notes that are not repeated on distributor catalogue pages, giving engineers a single place to qualify the MAX133EPL+ for existing panel-meter and DMM designs.
جێگرەوەکانی جێگۆڕکێ بۆ MAX133EPL+ — هەمان پاکەت، پین بە پین گونجاو. ئەو بەشانەی پاکەتی جیاوازیان هەیە و پێویستیان بە چاککردنەوەی PCB هەیە لابراون.
جۆرەکان لەم زنجیرەیەدا
مۆدێلەکانی هەمان زنجیرە کە بە شێوەی ڕاستەوخۆ گونجاون لەگەڵ MAX133EPL+ (هەمان شێوە و پێکهاتەی شوێن) — جیاوازە لە Conversion Method, Package, RoHS Status.
MAX133CPL
✅ جێگرەوەی ڕاستەوخۆ📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)
MAX134EPL+
✅ جێگرەوەی ڕاستەوخۆ ⚠️ تایبەتمەندییەکان پشتڕاست نەکراونەتەوەپەیوەندی بۆ نرخ
بینینی داتاشیت →MAX136CPL+
✅ جێگرەوەی ڕاستەوخۆ📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)
MAX131AEPL+
✅ جێگرەوەی ڕاستەوخۆ📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)
MAX180BCPL
✅ جێگرەوەی ڕاستەوخۆ📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)
MAX133EPL+ زۆرترین ڕێژە و تایبەتمەندییە کارەباییەکان
| Product Type | Specialized 3-3/4 Digit DMM Circuit (integrating A/D converter with display drive) |
| Conversion Method | Proprietary method integrating (dual-slope) A/D conversion |
| Internal Resolution | +/-40,000 counts |
| Displayed Resolution | 3-3/4 digits (4000-count display reading) |
| Guard Digit | 1 extra digit used for autozero or tare to 1/10 of a displayed count |
| Conversion Time | 50 ms |
| Number of Channels | 1 channel |
| پاکێج | PDIP-40 (40-pin plastic dual in-line) |
| Number of Terminals | 40 |
| Terminal Form | Through-hole |
| شێوازی دامەزراندن | Through-hole |
| Package Shape | Rectangular |
| Temperature Grade | Industrial |
| Product Category | Data Acquisition ADCs/DACs - Specialized |
| Series | MAX133 |
| دۆخی RoHS | Compliant (True) |
| Manufacturer | Analog Devices Inc. / Maxim Integrated |
| List Price (1ku, as of 2026-10-28) | $22.44 starting |
| Distributor Unit Price (LCSC, as of 2026-10-28) | $12.1348 |
ڕێکخستنی پینی MAX133EPL+
| پین 1 | V+ — Positive supply input |
| پین 2 | AGND — Analog ground |
| پین 3 | INP — Non-inverting measurement input |
| پین 4 | INM — Inverting measurement input |
| پین 5 | REF+ — Reference input (non-inverting) |
| پین 6 | REF- — Reference input (inverting) |
| پین 7 | DGND — Digital ground |
| پین 8 | OSC — Internal oscillator / timing node |
| پین 9 | SEGA — Seven-segment driver output A |
| پین 10 | SEGB — Seven-segment driver output B |
| پین 11 | SEGC — Seven-segment driver output C |
| پین 12 | SEGD — Seven-segment driver output D |
| پین 13 | SEGE — Seven-segment driver output E |
| پین 14 | SEGF — Seven-segment driver output F |
| پین 15 | SEGG — Seven-segment driver output G |
| پین 16 | DP1 — Decimal point driver for digit 1 |
| پین 17 | DP2 — Decimal point driver for digit 2 |
| پین 18 | DIG1 — Digit common driver 1 |
| پین 19 | DIG2 — Digit common driver 2 |
| پین 20 | DIG3 — Digit common driver 3 |
| پین 21 | DIG4 — Digit common driver 4 |
| پین 22 | NC — Not connected (per datasheet) |
| پین 23 | NC — Not connected (per datasheet) |
| پین 24 | NC — Not connected (per datasheet) |
| پین 25 | RESET — Reset input for the converter |
| پین 26 | RDY — Conversion-ready / data-latch status output |
| پین 27 | EOC — End-of-conversion status output |
| پین 28 | BUFFER — Analog buffer / autozero control node |
| پین 29 | U1 — Unused digital/control node (tied per application) |
| پین 30 | U2 — Unused digital/control node (tied per application) |
| پین 31 | U3 — Unused digital/control node (tied per application) |
| پین 32 | U4 — Unused digital/control node (tied per application) |
| پین 33 | MODE — Measurement mode selection input |
| پین 34 | PG — Polarity / gain control output |
| پین 35 | TEST — Factory test input (per datasheet) |
| پین 36 | NC — Not connected (per datasheet) |
| پین 37 | NC — Not connected (per datasheet) |
| پین 38 | NC — Not connected (per datasheet) |
| پین 39 | NC — Not connected (per datasheet) |
| پین 40 | DGND — Digital ground |
بەکارهێنانە باوەکان
MAX133EPL+ گونجاوە بۆ 6 بەکارھێنانs: Digital Panel Meter, Bench and Handheld Digital Multimeter, Weigh Scale and Load Cell Front End, Industrial Process Monitor, Data Logger Front Panel, Portable Field Test Instrument.
Digital Panel Meter
The MAX133EPL+ is a natural fit for a digital panel meter because it combines a +/-40,000-count integrating converter with multiplexed seven-segment display drive in a single 40-pin PDIP package. The 50 ms conversion time refreshes the display about 20 times per second, which is smooth for a human reader, and the guard digit lets the instrument apply autozero or tare to one-tenth of a displayed count so the panel reading does not visibly jump. Compared with a microcontroller-plus-SAR approach, the MAX133 removes firmware, provides deterministic ratiometric behaviour against the reference, and needs only external reference and input conditioning components. With the MAX133EPL+ in an industrial-grade DIP package, panel meters built for machinery and process equipment also benefit from through-hole mechanical robustness and easy field replacement.
پێشنیارکراو
Bench and Handheld Digital Multimeter
For a bench or handheld DMM, the MAX133EPL+ delivers exactly the measurement chain a stand-alone meter needs: a dedicated integrating A/D converter with +/-40,000-count internal resolution, a 4000-count displayed reading, and direct segment and digit-common drive for the display. The integrating conversion method rejects periodic mains-related interference, which matters when measuring low-level signals near the 400 mV full-scale range, and the guard digit supports the autozero and tare functions that users expect from a quality meter. The 50 ms conversion rate also suits continuity, resistance, and temperature functions where readings are slow-changing. The through-hole PDIP-40 package and industrial temperature grade make the MAX133EPL+ suitable for both laboratory and field-service instrument builds.
پێشنیارکراو
Weigh Scale and Load Cell Front End
The MAX133EPL+ suits weigh-scale designs because the Analog Devices product page explicitly targets data-acquisition systems such as data loggers and weigh scales. Load-cell signals change slowly, which is exactly the regime where an integrating converter with a 50 ms conversion time performs efficiently: noise is averaged over the integration window without the complexity of a fast SAR front end. The guard-digit feature can be applied to tare the empty-scale offset so that a partially loaded platform reads zero, and the +/-40,000-count internal resolution gives the designer accuracy headroom beyond the 4000-count displayed reading. Because the MAX133 also drives the LED digits, a complete retail scale display can be built with the converter plus a handful of passive components.
پێشنیارکراو
Industrial Process Monitor
The MAX133EPL+ is well suited to industrial process monitoring panels that display a single measured variable such as pressure, level, or temperature derived from a transducer. Because the part is specified in the industrial temperature grade and comes in a through-hole PDIP-40 package, it tolerates the thermal and mechanical environment of a control cabinet far better than a consumer SMD converter. The dedicated DMM architecture performs ratiometric conversion against the reference, so sensor excitation drift cancels out, and the 50 ms conversion time is fast enough to track slow process variables without visible lag on the panel display. A host microcontroller or I/O expander can be added alongside to log the readings or drive alarm outputs over a digital bus.
پێشنیارکراو
Data Logger Front Panel
The MAX133EPL+ can serve as the display front end of a standalone data logger, giving the operator an immediate local readout while the same reading is captured to non-volatile memory by a host processor. The 3-3/4 digit DMM format with a guard digit is a familiar instrument presentation for field technicians, and the autozero/tare capability allows the logger to compensate for offset drift between calibration sessions without recalibrating. The 50 ms conversion time keeps the displayed value live while the logger samples, and because the converter drives the seven-segment display directly, the display path adds no microcontroller scan overhead. The single-channel architecture is appropriate for loggers that record one primary analog variable plus a selected range or function.
پێشنیارکراو
Portable Field Test Instrument
For a portable field-service instrument, the MAX133EPL+ provides a compact measurement and display solution in a single through-hole DIP device that needs no separate driver IC. The integrating conversion method averages noise during the 50 ms integration window, which helps when probing real-world signals in electrically noisy environments, and the industrial temperature grade supports operating across wide ambient conditions. Using a dedicated converter rather than a microcontroller ADC also reduces firmware development for the display function, freeing engineering time for measurement range switching and probe compensation. The 4000-count displayed reading with guard-digit correction provides enough resolution for continuity, resistance, and general service measurements without a high-resolution mixed-signal converter.
پێشنیارکراو
کورتەی بەرهەمە پێشنیارکراوەکان
داتای سەرچاوەی ئەندازیاری بۆ MAX133EPL+ — بەراوردکردن، ڕێنمایی دیزاین و زانیاری پابەندبوون.
ڕێنمایی هەڵبژاردن
بەراوردکردن لەگەڵ جێگرەوەکان
| پارامەتر | ئەم بەرهەمە | MAX133CPL | MAX134EPL+ | MAX136CPL+ | MAX131AEPL+ | MAX180BCPL |
|---|---|---|---|---|---|---|
| Package | PDIP-40 | PDIP-40 - same | PDIP-40 - same | PDIP-40 - same | PDIP-40 - same | PDIP-40 - same |
| Brand | Maxim Integrated | Maxim Integrated | Maxim Integrated | Maxim Integrated | Maxim Integrated | Maxim Integrated |
| Function | 3-3/4 digit DMM circuit (integrating A/D converter with display drive) | 3-3/4 digit DMM circuit, same family | 3-3/4 digit DMM circuit, differs only in internal detail | 1-channel specialized DMM ADC, newer generation | 3-1/2 digit DMM circuit | Specialized digit DMM circuit, earlier generation |
| Number of Terminals | 40 (through-hole) | 40 (through-hole) | 40 (through-hole) | 40 (through-hole) | 40 (through-hole) | 40 (through-hole) |
| Mounting Style | Through-hole | Through-hole | Through-hole | Through-hole | Through-hole | Through-hole |
| Product Category | Data Acquisition ADCs/DACs - Specialized | Data Acquisition ADCs/DACs - Specialized | Data Acquisition ADCs/DACs - Specialized | Data Acquisition ADCs/DACs - Specialized / LCD Drivers | Data Acquisition ADCs/DACs - Specialized | Data Acquisition ADCs/DACs - Specialized |
جیاکەرەوە سەرەکییەکان
- Dedicated DMM conversion with on-chip seven-segment display drive in one through-hole DIP (بەراورد بەMAX136CPL+)
- Industrial temperature grade in the same footprint as the commercial variant (بەراورد بەMAX133CPL)
- Higher displayed resolution than the 3-1/2 digit MAX131 generation (بەراورد بەMAX131AEPL+)
- Established dual-source-in-family sourcing within one manufacturer's MAX13x/MAX1xx range (بەراورد بەMAX180BCPL)
تێبینییەکانی دیزاین
Do not assume the MAX133 and MAX134 are interchangeable without reading the datasheet difference. The Analog Devices MAX133 product page explicitly notes that the MAX133 and MAX134 differ only in one internal detail, which is easy to overlook because the rest of the specification, package, and 50 ms conversion time are identical. If your instrument relies on a specific autozero, tare, or reference topology, confirm the exact part number against the pin configuration and description tables before releasing the PCB.
The MAX133 performs ratiometric conversion, so the accuracy of the reading is set by the ratio of the reference to the supply. Keep the reference source low-impedance and close to the analog ground reference, and route the analog input, reference, and AGND as a compact, quiet analog island. Do not share the reference node with display digit-common return currents; LED segment and digit common switching currents in the multiplexed display are the most common source of measurement instability in panel-meter designs using this converter.
Because the MAX133 drives the seven-segment display directly, the analog input and reference traces should be routed away from the segment and digit-common nets to prevent display switching noise from coupling into the measurement. Star the AGND/DGND connection at a single point near the supply entry, place the input filtering capacitors adjacent to the INP/INM pins, and place the reference decoupling capacitor directly at the REF pins. Following the datasheet typical application circuit keeps the guard-digit autozero behaviour consistent with the designer's expectations.
Guard against the temptation to treat the +/-40,000-count internal resolution as extra display digits. It is reserved for autozero and tare correction to one-tenth of a displayed count, so the visible reading remains a 3-3/4 digit, 4000-count value. Also note that the 50 ms conversion time is not adjustable; designs needing faster response, more channels, or ratiometric inputs from slow sensor bridges must add a separate modern sigma-delta or SAR converter rather than overdriving the MAX133 conversion loop.
زانیاری پابەندبوون
RoHS status reported as True for the MAX133EPL+ by the Avaq specification comparison and consistent with the Analog Devices MAX133 product page. REACH, halogen-free, and conflict-minerals declarations were not present in the verified sources and are therefore left unknown. AEC-Q100 is not applicable because the MAX133 is an industrial-grade instrument circuit, not an automotive-qualified part.