An RS-232 transceiver is an interface IC that combines voltage-conversion line drivers and receivers with a logic-level UART interface. The MAX211 family belongs to the hierarchy RS-232 transceiver → serial interface IC → interface IC → semiconductor. By converting between logic-level signals and RS-232 levels, it enables equipment with a serial UART port to communicate with peripherals, computers, industrial controllers, and other equipment using the TIA/EIA-232-F electrical interface.
Four driver channels support bidirectional serial links, while the five receiver channels provide additional receive capability. The MAX211CDWG4 operates to 120 kbit/s, making it suitable for moderate-speed data links rather than high-speed differential communications. Its 5 V supply operation is compatible with conventional 5 V logic systems, although the interface voltage levels remain RS-232 bipolar signals rather than CMOS levels.
The device provides ±15 kV HBM ESD protection on its RS-232 pins and meets or exceeds TIA/EIA-232-F and ITU V.28 requirements. Shutdown operation reduces supply current to a typical 1 µA, which helps conserve power when the interface is inactive. These protections and shutdown characteristics are important in industrial and commercial environments where cables can be exposed to electrostatic discharge or where predictable low-power operation is required.
Typical applications include RS-232 ports on industrial controllers, test equipment, data-acquisition systems, point-of-sale equipment, and embedded serial interfaces. The 28-pin SOIC package also supports conventional surface-mount assembly. Designers should account for RS-232's unbalanced signaling, cable-length limitations, ground-reference issues, and the need for suitable interface protection when connecting the device to external equipment.
Place the device close enough to the connector to minimize the unprotected length of the RS-232 traces. Use the pin-description table in the manufacturer datasheet when assigning signals and decoupling pins. If the system also uses RS-485, RS-422, or USB, select the corresponding interface IC rather than treating an RS-232 transceiver as a universal serial-port solution.
This page combines device specifications, replacement guidance, pin and application considerations, and parameter-level comparisons to support engineering selection and PCB implementation. Use the Request a Quote form for current commercial availability, lead time, and sourcing support.
جێگرەوەکانی جێگۆڕکێ بۆ MAX211CDWG4 — هەمان پاکەت، پین بە پین گونجاو. ئەو بەشانەی پاکەتی جیاوازیان هەیە و پێویستیان بە چاککردنەوەی PCB هەیە لابراون.
جۆرەکان لەم زنجیرەیەدا
مۆدێلەکانی هەمان زنجیرە کە بە شێوەی ڕاستەوخۆ گونجاون لەگەڵ MAX211CDWG4 (هەمان شێوە و پێکهاتەی شوێن) — جیاوازە لە ESD Protection, Operating Temperature Range, Package, RoHS Status, Shutdown Supply Current.
MAX211IDW
✅ جێگرەوەی ڕاستەوخۆپەیوەندی بۆ نرخ
بینینی داتاشیت →MAX211CDWG4 تایبەتمەندییەکان
| Product Type | Multichannel RS-232 line driver/receiver |
| Number of Drivers | 4 channels |
| Number of Receivers | 5 channels |
| Transceiver Configuration | 4/5 full RS-232 transceiver |
| Nominal Supply Voltage | 5 V |
| Operating Supply Voltage Range | 4.5 V to 5.5 V |
| Maximum Data Rate | 120 kbit/s |
| Shutdown Supply Current | 1 µA typical |
| ESD Protection | ±15 kV using Human-Body Model |
| RS-232 Compliance | Meets or exceeds TIA/EIA-232-F requirements |
| ITU Compliance | Meets or exceeds ITU V.28 requirements |
| مەودای پلەی گەرمیی کارکردن | 0°C to +70°C |
| Temperature Grade | Commercial |
| پاکێج | 28-pin SOIC, 300 mil |
| Number of Terminals | 28 terminals |
| Terminal Form | Gull wing |
| Package Shape | Rectangular |
| دۆخی RoHS | RoHS compliant |
| Safe Operating Area | Not applicable |
ڕێنمایی ڕێکخستنی پینی MAX211CDWG4 rectangular
ڕێکخستنی پین بۆ MAX211CDWG4 (پاکێجی rectangular). ژمارەدانی پین، فەنکشنەکان و نەخشەکانی پەیوەندی لە داتاشیتی بەرھەمھێنەردا پێناسە کراون. سەرنجی بدە بۆ شوێنپێی ورد و ڕێنمایییەکانی لەحیمکردن.
هیچ داتای وردی پینئاوت بەردەست نییە بۆ MAX211CDWG4.
سەرنج بدە بە داتاشیت بۆ ڕێکخستنی تەواوی پینەکان.
بەکارهێنانە باوەکان
MAX211CDWG4 گونجاوە بۆ 6 بەکارھێنانs: Industrial Serial Control Interface, Data Acquisition and Test Equipment, Point-of-Sale and Peripheral Connectivity, Embedded Equipment Communication, Communication and Networking Equipment, Legacy Port Modernization.
Industrial Serial Control Interface
The MAX211CDWG4 fits industrial equipment requiring several RS-232 channels on a common 5 V interface. Its four drivers and five receivers allow multiple UART links to be consolidated without redesigning the logic-side circuitry, while 120 kbit/s operation covers conventional control and monitoring traffic. The commercial 0°C to +70°C rating is appropriate when the controller remains inside a temperature-controlled enclosure. Its 1 µA typical shutdown current also helps conserve power when the serial interface is disabled. Designers should use the manufacturer pin descriptions to assign enable and channel functions, and should verify that cable length, grounding, and UART baud-rate tolerance meet the requirements of each industrial link.
پێشنیارکراو
Data Acquisition and Test Equipment
The MAX211CDWG4 is useful in data-acquisition instruments and test systems that must connect a controller to legacy RS-232 equipment. The four driver channels support outbound control or measurement commands, and five receiver channels provide additional inputs for external instruments. At up to 120 kbit/s, the device accommodates many legacy serial configurations without requiring a high-speed differential interface. ±15 kV HBM protection and shutdown support improve robustness and power management in portable test equipment. Confirm the manufacturer electrical limits, use a stable 5 V supply, and validate the selected UART baud rate against the cable length and receiver characteristics before finalizing the instrument interface.
پێشنیارکراو
Point-of-Sale and Peripheral Connectivity
The MAX211CDWG4 can support multi-port RS-232 connectivity in point-of-sale terminals, receipt printers, scanners, and related peripherals. Four drivers and five receivers provide more channels than a basic single-port transceiver while preserving a straightforward 5 V UART architecture. The 120 kbit/s operating limit is suitable for many peripheral data rates, and the low-power shutdown state helps system designers isolate unused ports. Because RS-232 is an unbalanced interface, reliable operation also depends on proper signal grounding, cable routing, and protection at externally accessible connectors. The commercial temperature specification should be checked against the actual operating environment of the terminal or peripheral enclosure.
پێشنیارکراو
Embedded Equipment Communication
The MAX211CDWG4 is appropriate for embedded systems that retain RS-232 compatibility while requiring more than one serial line. A host processor can use the logic-side driver and receiver connections to communicate with programming fixtures, service tools, or external controllers. The 4.5 V to 5.5 V operating range supports a regulated 5 V rail, and the 1 µA typical shutdown current is useful in intermittently powered service modes. Place the transceiver near the RS-232 connector so exposed traces remain short, and use the datasheet pin table for every channel assignment. The MAX211IDW provides the same family architecture where an industrial temperature range is required instead of the 0°C to +70°C commercial range.
پێشنیارکراو
Communication and Networking Equipment
The MAX211CDWG4 can provide management and configuration ports in communication equipment that still uses RS-232 rather than USB or Ethernet. Multiple drivers and receivers allow one controller to manage several subordinate devices, while 120 kbit/s operation covers typical administrative and control traffic. The device's shutdown function helps isolate the interface during inactive periods, and its documented ESD withstand level supports cautious use in externally accessed equipment. Signal integrity remains important because long or poorly grounded RS-232 cables can disturb received data. Keep connector-side routing compact, follow the manufacturer decoupling recommendations, and use the MAX211IDW when the equipment must operate across the industrial temperature range.
پێشنیارکراو
Legacy Port Modernization
The MAX211CDWG4 is useful when a modern controller must retain compatibility with legacy RS-232 equipment. Four driver channels and five receiver channels allow an adapter or embedded controller to bridge several serial functions without requiring separate single-channel transceivers. The 120 kbit/s limit supports many legacy control protocols, while the 5 V supply simplifies integration with conventional embedded logic. During modernization, verify that the legacy equipment uses RS-232 rather than RS-422, RS-485, or TTL serial levels, because electrical compatibility cannot be inferred from connector shape. Select the MAX211IDW when environmental requirements exceed the commercial 0°C to +70°C range of the MAX211CDWG4.
پێشنیارکراو
کورتەی بەرهەمە پێشنیارکراوەکان
داتای سەرچاوەی ئەندازیاری بۆ MAX211CDWG4 — بەراوردکردن، ڕێنمایی دیزاین و زانیاری پابەندبوون.
ڕێنمایی هەڵبژاردن
بەراوردکردن لەگەڵ جێگرەوەکان
| پارامەتر | ئەم بەرهەمە | MAX211IDW |
|---|---|---|
| Brand | Texas Instruments | Texas Instruments |
| Package | SOIC-28 (300 mil) | SOIC-28 |
| Product Type | Multichannel RS-232 line driver/receiver | Multichannel RS-232 line driver/receiver |
| Number of Drivers | 4 channels | 4 channels |
| Number of Receivers | 5 channels | 5 channels |
| Operating Supply Voltage Range | 4.5 V to 5.5 V | 5 V nominal |
| Maximum Data Rate | 120 kbit/s | 120 kbit/s |
| Operating Temperature Range | 0°C to +70°C | -40°C to +85°C |
| Temperature Grade | Commercial | Industrial |
جیاکەرەوە سەرەکییەکان
- Commercial-temperature MAX211 implementation (بەراورد بەMAX211IDW)
- Four-driver, five-receiver channel count (بەراورد بەMAX211IDW)
- 120 kbit/s operation with integrated shutdown (بەراورد بەMAX211IDW)
تێبینییەکانی دیزاین
Place the MAX211CDWG4 close to the RS-232 connector and keep the externally accessible driver and receiver traces short. Follow the manufacturer datasheet for supply decoupling and connect the designated ground pins directly to the ground plane. Avoid routing RS-232 traces beneath fast digital or switching-supply nodes, because the unbalanced interface can pick up crosstalk even when the UART data rate is moderate.
Operate the transceiver from a regulated 5 V rail within the specified 4.5 V to 5.5 V range. Use the decoupling configuration shown in the manufacturer application guidance and keep the supply-return path continuous. The typical shutdown current is 1 µA, but total system consumption also depends on the logic-side loads, external protection devices, and any pull components connected to the RS-232 pins.
Do not treat every D-sub or serial connector as an RS-232 interface. Verify that the external equipment uses bipolar RS-232 levels because the MAX211CDWG4 does not directly accept RS-422, RS-485, or TTL signals. Also account for RS-232 ground-reference offsets, cable length, baud-rate tolerance, and the 120 kbit/s maximum when designing the link.
Use a solid chassis or signal-ground strategy appropriate to the installation, especially when the RS-232 cable leaves the enclosure. Keep unprotected cable-side traces short and provide external surge or ESD protection when the port will be repeatedly connected or disconnected. Device-level HBM withstand does not remove the need to control EMI, cable transients, and ground loops in the complete product.