MAX232IDR - 120 kbps Dual RS-232 Transceiver | Texas Instruments
MPN: MAX232IDR ✓ چالاکMAX232IDR گشتی
An RS-232 transceiver is an interface IC that converts logic-level signals into bipolar RS-232 levels and converts incoming bipolar signals back into logic levels. Within the interface hierarchy, the MAX232 belongs to the RS-232 transceiver family of interface ICs used to connect modern digital equipment with legacy serial ports. It is especially useful where a UART provides TTL or CMOS logic but the peripheral expects true RS-232 signaling.
The MAX232IDR provides two transmit channels and two receive channels, making it suitable for implementing one or two complete point-to-point serial links. Its stated 120 kbit/s operating rate covers standard asynchronous serial communication, while the single-supply design simplifies PCB power planning. The manufacturer also identifies approximately ±9 V driver output levels and ±2 kV ESD protection as principal benefits of the MAX232 family.
Internally, the charge-pump voltage converter supplies the bipolar levels required by the drivers. Receivers tolerate RS-232 input levels down to ±30 V, allowing connected equipment to present stronger transients without immediately damaging the receive path. The manufacturer lists low supply current of approximately 8 mA typical, and the device is designed for interchangeability with the classic Maxim MAX232.
Typical applications include serial adapters, industrial control consoles, instrumentation, and embedded systems that communicate with RS-232 equipment through a UART. One receiver and driver can form a bidirectional data path when the transmit and receive lines are cross-connected; the second pair provides another channel or additional unidirectional interface. It is also useful when a legacy printer, controller, or service port requires RS-232 rather than TTL levels.
Designers should place the charge-pump capacitors close to the IC and route the RS-232 traces away from sensitive analog and high-speed digital signals. Decoupling near VCC reduces supply disturbance, while the receiver’s ±30 V input capability should not be confused with ±30 V output capability: the specified driver output is approximately ±9 V. Cable protection and grounding remain necessary for reliable operation with external equipment.
This page combines the manufacturer’s electrical specifications, ordering information, package details, cross-reference results, and practical implementation guidance. It also identifies same-footprint alternatives and explains the electrical distinctions that should be checked before replacing the MAX232IDR in an existing design.
جێگرەوەکانی جێگۆڕکێ بۆ MAX232IDR — هەمان پاکەت، پین بە پین گونجاو. ئەو بەشانەی پاکەتی جیاوازیان هەیە و پێویستیان بە چاککردنەوەی PCB هەیە لابراون.
جۆرەکان لەم زنجیرەیەدا
مۆدێلەکانی هەمان زنجیرە کە بە شێوەی ڕاستەوخۆ گونجاون لەگەڵ MAX232IDR (هەمان شێوە و پێکهاتەی شوێن) — جیاوازە لە Operating Temperature Range, Package, Product Type, Data Rate, ESD Protection.
MAX232EIDR
✅ جێگرەوەی ڕاستەوخۆ ⚠️ تایبەتمەندییەکان پشتڕاست نەکراونەتەوەپەیوەندی بۆ نرخ
بینینی داتاشیت →MAX232AIDR
✅ جێگرەوەی ڕاستەوخۆ ⚠️ تایبەتمەندییەکان پشتڕاست نەکراونەتەوە📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)
MAX232CSE+T
✅ جێگرەوەی ڕاستەوخۆ ⚠️ تایبەتمەندییەکان پشتڕاست نەکراونەتەوەپەیوەندی بۆ نرخ
بینینی داتاشیت →TRS232EIDWR
✅ جێگرەوەی ڕاستەوخۆ📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)
SP232EET-L/TR
✅ جێگرەوەی ڕاستەوخۆ ⚠️ تایبەتمەندییەکان پشتڕاست نەکراونەتەوەپەیوەندی بۆ نرخ
بینینی داتاشیت →SP232ECN-L/TR
✅ جێگرەوەی ڕاستەوخۆ ⚠️ تایبەتمەندییەکان پشتڕاست نەکراونەتەوەپەیوەندی بۆ نرخ
بینینی داتاشیت →MAX232IDR تایبەتمەندییەکان
| Product Type | Dual RS-232 transceiver |
| Transmitter Channels | 2 |
| Receiver Channels | 2 |
| Maximum Data Rate | 120 kbit/s |
| Supply Voltage Range | 4.5 V to 5.5 V |
| Nominal Supply Voltage | 5 V |
| Driver Output Level | Approximately ±9 V |
| Receiver Input Level Range | ±30 V |
| ESD Protection | ±2 kV |
| ئێستای دابینکردن | 8 mA typical |
| Supported Standards | TIA/EIA-232-F and ITU Recommendation V.28 |
| پاکێج | 16-pin SOIC |
| جۆری دامەزراندن | Surface mount |
| Interface Standard | RS-232 / EIA-232 |
| Supply Configuration | Single supply |
ڕێنمایی ڕێکخستنی پینی MAX232IDR 16-pin soic
ڕێکخستنی پین بۆ MAX232IDR (پاکێجی 16-pin soic). ژمارەدانی پین، فەنکشنەکان و نەخشەکانی پەیوەندی لە داتاشیتی بەرھەمھێنەردا پێناسە کراون. سەرنجی بدە بۆ شوێنپێی ورد و ڕێنمایییەکانی لەحیمکردن.
هیچ داتای وردی پینئاوت بەردەست نییە بۆ MAX232IDR.
سەرنج بدە بە داتاشیت بۆ ڕێکخستنی تەواوی پینەکان.
بەکارهێنانە باوەکان
MAX232IDR گونجاوە بۆ 6 بەکارھێنانs: Industrial UART-to-RS-232 Interface, Legacy Serial Adapter, Test and Measurement Instrumentation, Embedded Service Console, Printer and POS Equipment, RS-232 Signal Conditioning in Control Cards.
Industrial UART-to-RS-232 Interface
The MAX232IDR fits industrial control boards that expose a TTL or CMOS UART but must communicate with legacy RS-232 equipment. Its two drivers and two receivers support a complete bidirectional link when the transmit and receive conductors are cross-connected. Operating from a single 4.5 V to 5.5 V supply simplifies the interface power rail, while the receiver’s tolerance for ±30 V input levels provides margin against external line transients. The 120 kbit/s rate is suitable for conventional asynchronous service links. Designers should still verify industrial temperature requirements, add appropriate cable protection, and keep the interface ground connected according to the RS-232 system design.
پێشنیارکراو
Legacy Serial Adapter
The MAX232IDR is well suited to adding an RS-232 port to a modern controller whose UART uses logic-level signals. One driver and receiver pair can implement the bidirectional transmit and receive path, while the second pair can serve another port or a unidirectional status connection. The integrated charge pump generates the positive and negative voltages required by RS-232 from a 5 V supply, eliminating a separate negative rail. With a maximum rate of 120 kbit/s, it supports conventional UART traffic while reducing the component count compared with discrete level-shifting networks.
پێشنیارکراو
Test and Measurement Instrumentation
The MAX232IDR can connect laboratory instruments and service equipment that retain RS-232 communication ports. Its two-driver, two-receiver arrangement supports instrument-control and diagnostic channels without requiring separate level-shifting circuits. The approximately ±9 V driver outputs comply with the bipolar signaling used by RS-232 equipment, while the receivers accept levels down to ±30 V. A 120 kbit/s data rate is appropriate for command and response traffic rather than high-rate bulk transfer. Place the interface capacitors close to the device, connect a suitable reference ground, and use shielded cable where the instrument can be exposed to electrically noisy environments.
پێشنیارکراو
Embedded Service Console
The MAX232IDR enables an embedded processor or microcontroller to implement an RS-232 service console for configuration, diagnostics, or firmware commands. Two independent channel pairs provide useful flexibility: one pair can handle interactive communication while the other carries logging or equipment-control traffic. Its single 5 V supply architecture fits systems that already operate from 5 V, and the 120 kbit/s limit is more than adequate for typical character-oriented console sessions. Firmware should configure the UART baud rate and framing to match the connected equipment, while the hardware design must account for polarity, grounding, connector retention, and external transient protection.
پێشنیارکراو
Printer and POS Equipment
The MAX232IDR can provide the physical RS-232 layer for a printer, point-of-sale terminal, or receipt device connected to a UART-based controller. Two transmit and receive channels allow a main command channel and an auxiliary status channel, subject to the connected equipment’s wiring. The device’s 120 kbit/s capability supports conventional receipt and transaction traffic, and the integrated charge pump avoids a separate negative supply. For installations using long cables or unknown external equipment, add appropriately selected surge protection and maintain a common signal reference. Verify the connector’s signal assignment and logic polarity before enabling the transmitter to avoid an unusable but seemingly functional communication link.
پێشنیارکراو
RS-232 Signal Conditioning in Control Cards
The MAX232IDR is useful in modular control cards that must bridge modern logic to older RS-232 equipment while preserving a straightforward 5 V power architecture. Its dual-channel structure can reduce the number of level-conversion devices when two serial links are required. The receive path’s ±30 V input tolerance is particularly relevant to equipment with long exposed cables, although it does not eliminate the need for protection networks. The approximately ±2 kV ESD protection provides an additional design margin, but board layout remains important: keep charge-pump traces short, provide local supply decoupling, and maintain separation between RS-232 routes and sensitive analog or high-speed digital nets.
پێشنیارکراو
کورتەی بەرهەمە پێشنیارکراوەکان
داتای سەرچاوەی ئەندازیاری بۆ MAX232IDR — بەراوردکردن، ڕێنمایی دیزاین و زانیاری پابەندبوون.
ڕێنمایی هەڵبژاردن
بەراوردکردن لەگەڵ جێگرەوەکان
| پارامەتر | ئەم بەرهەمە | MAX232EIDR | MAX232AIDR | MAX232CSE | TRS232EIDWR | SP232EET-L/TR |
|---|---|---|---|---|---|---|
| Package | SOIC-16 | SOIC-16 | SOIC-16 | SOIC-16 | SOIC-16 | SOIC-16 |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Transmitter Channels | 2 | 2 | 2 | 2 | 2 | 2 |
| Receiver Channels | 2 | 2 | 2 | 2 | 2 | 2 |
جیاکەرەوە سەرەکییەکان
- Direct same-family 16-pin SOIC replacement path (بەراورد بەTRS232EIDWR)
- Two complete RS-232 channels in one package (بەراورد بەSP232EET-L/TR)
- Single-supply bipolar interface generation (بەراورد بەMAX232CSE)
تێبینییەکانی دیزاین
Place the charge-pump capacitors and the VCC bypass capacitor directly beside their associated MAX232IDR pins, with short ground paths and no test pads or stubs between the capacitor pads and the device. The manufacturer application circuit should be used for the exact capacitor values. A long loop around the charge-pump pins can increase radiated emissions and make the supply disturbance visible on adjacent sensitive circuits.
Keep the RS-232 driver traces away from clocks, ADC inputs, crystal circuits, and low-level analog nodes. Route the connector-side nets as a compact RS-232 channel and provide a suitable chassis or signal-ground strategy according to the connected equipment. Although the receiver accepts input levels to ±30 V, that rating does not replace external surge protection when cables leave the enclosure.
Do not connect a TTL UART directly to the RS-232 connector, and do not apply RS-232 bipolar voltages directly to the logic-side receiver. The MAX232IDR requires the correct charge-pump capacitors, local supply decoupling, and a logic supply near 5 V. Also verify that transmit and receive conductors are crossed correctly at the D-sub connector and that the equipment shares a suitable ground reference.
The ±9 V driver transitions can contain fast edges and radiate noise even at a 120 kbit/s data rate. Use the shortest practical connection to the connector, maintain a continuous ground reference, and avoid splitting the interface ground. If the board combines RS-232 with sensitive analog circuitry, increase physical separation and place filtering near the connector rather than relying on the MAX232IDR’s approximately ±2 kV ESD rating as a complete EMC solution.
زانیاری پابەندبوون
The MAX232 is a general-purpose RS-232 interface IC rather than an automotive-qualified device. RoHS, REACH, lead-free, halogen-free, and conflict-minerals status were not stated in the cited product and search information and therefore remain unknown.