SN65HVD21P - Extended Common-Mode RS-485 Transceiver | Texas Instruments
MPN: SN65HVD21P ✓ چالاکSN65HVD21P گشتی
An RS-485 transceiver is a type of interface IC that bridges a logic-level UART or SPI port and a balanced, differential bus. The differential signalling rejects common-mode noise, so the bus keeps working in electrically noisy environments such as factory floors, HVAC plants, motor drives and utility metering cabinets. The SN65HVD21P belongs to the hierarchy: transceiver -> differential line driver and receiver -> interface IC -> integrated circuit -> semiconductor.
Because the driver and receiver share one package, the same device supports half-duplex point-to-point links as well as multidrop configurations where up to multiple unit-load nodes tap onto one pair of wires. The three control pins (driver enable, receiver enable and driver input) let a host microcontroller decide which direction the bus drives, while the receiver output returns logic-level data to the host. The PDIP package keeps the device compatible with through-hole assembly, prototyping boards and legacy industrial control boards.
Typical deployments include industrial RS-485 multidrop sensor buses, building and HVAC controller networks, industrial motor drive and encoder feedback links, utility and energy metering terminals, and long-distance instrumentation links to remote transducer heads. Because the transceiver is a half-duplex device, the design must allow the bus to turn around between transmit and receive windows.
The main design consideration is termination and biasing. The SN65HVD21P works correctly on an unterminated short cable, but long or high-speed runs need a termination resistor at each far end and a fail-safe bias network so the idle state is defined. Keep the differential pair tightly coupled, route it over a continuous ground plane, and connect the transceiver ground to the board ground with a short, low-inductance path.
This page combines the manufacturer part detail, distributor availability, drop-in replacement options in the same 8-pin PDIP footprint, and practical bus-design guidance so engineers can evaluate the SN65HVD21P without hunting across several separate documents.
جێگرەوەکانی جێگۆڕکێ بۆ SN65HVD21P — هەمان پاکەت، پین بە پین گونجاو. ئەو بەشانەی پاکەتی جیاوازیان هەیە و پێویستیان بە چاککردنەوەی PCB هەیە لابراون.
جۆرەکان لەم زنجیرەیەدا
مۆدێلەکانی هەمان زنجیرە کە بە شێوەی ڕاستەوخۆ گونجاون لەگەڵ SN65HVD21P (هەمان شێوە و پێکهاتەی شوێن) — جیاوازە لە Package, Product Type, Transceiver Configuration, Mounting Type, Data Rate.
SN65HVD22P
✅ جێگرەوەی ڕاستەوخۆ ⚠️ تایبەتمەندییەکان پشتڕاست نەکراونەتەوەپەیوەندی بۆ نرخ
بینینی داتاشیت →SN65HVD23P
✅ جێگرەوەی ڕاستەوخۆ ⚠️ تایبەتمەندییەکان پشتڕاست نەکراونەتەوەپەیوەندی بۆ نرخ
بینینی داتاشیت →SN65HVD26P
✅ جێگرەوەی ڕاستەوخۆ ⚠️ تایبەتمەندییەکان پشتڕاست نەکراونەتەوە📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)
MAX485EPA+
✅ جێگرەوەی ڕاستەوخۆپەیوەندی بۆ نرخ
بینینی داتاشیت →SP485EEN-L
✅ جێگرەوەی ڕاستەوخۆپەیوەندی بۆ نرخ
بینینی داتاشیت →ADM485JNZ
✅ جێگرەوەی ڕاستەوخۆپەیوەندی بۆ نرخ
بینینی داتاشیت →SN65HVD21P تایبەتمەندییەکان
| Device Type | Extended common-mode RS-485 transceiver |
| Transceiver Configuration | 1/1 (one driver, one receiver), half duplex |
| Supported Standards | RS-485, RS-422 |
| Number of Transmitters | 1 |
| Number of Receivers | 1 |
| پاکێج | PDIP (P), 8 pins |
| ژمارەی پین | 8 |
| جۆری دامەزراندن | Through-hole |
| Enable Pins | Driver enable (DE), receiver enable (RE) |
| Termination | External, not integrated |
| Manufacturer | Texas Instruments |
ڕێکخستنی پینی SN65HVD21P
| پین 1 | RO — Receiver output, logic-level data to the host controller |
| پین 2 | RE — Receiver enable, active-low input |
| پین 3 | DE — Driver enable, active-high input |
| پین 4 | DI — Driver data input from the host controller |
| پین 5 | GND — Ground connection for the transceiver |
| پین 6 | Y — Driver inverting output for the differential pair |
| پین 7 | A — Driver non-inverting output for the differential pair |
| پین 8 | VCC — Positive supply connection for the transceiver |
بەکارهێنانە باوەکان
SN65HVD21P گونجاوە بۆ 6 بەکارھێنانs: Industrial Multidrop Sensor Bus, Building Automation and HVAC Controller Networks, Industrial Motor Drive and Encoder Feedback, Utility and Energy Metering Terminals, Long-Distance Instrumentation to Remote Sensors, Legacy Through-Hole Test and Measurement Equipment.
Industrial Multidrop Sensor Bus
The SN65HVD21P fits factory sensor and actuator buses where several nodes share one twisted pair and ground potentials may drift. Its extended common-mode RS-485 rating keeps the receiver usable when a remote sensor returns data from a ground reference shifted by several volts relative to the controller, a condition that saturates standard RS-485 receivers. The 8-pin PDIP package mounts directly on legacy industrial control boards, and the driver-enable and receiver-enable pins let the host microcontroller arbitrate bus direction for half-duplex polling of up to multiple unit-load nodes.
پێشنیارکراو
Building Automation and HVAC Controller Networks
Building control panels, room thermostats and HVAC controllers typically run RS-485 over long corridors and across floors. The SN65HVD21P is well suited to this environment because its extended common-mode tolerance absorbs the ground differences that appear when controllers are powered from different building circuits, and because the PDIP package fits the through-hole control boards used in this industry. A single transceiver per controller handles both directions of the half-duplex link, with the enable pins driven by the host microcontroller to switch between transmit and receive without external switching components.
پێشنیارکراو
Industrial Motor Drive and Encoder Feedback
Servo and inverter platforms often carry incremental encoder or drive-status information over RS-485 to a motion controller several metres away. The SN65HVD21P suits this path because the differential receiver rejects the electrical noise generated by switching power stages, and the extended common-mode range covers the offset between the drive ground and the controller ground on multi-axis machines. The half-duplex driver stays disabled except during the encoder response window, which keeps the bus free for other axes sharing the same twisted pair.
پێشنیارکراو
Utility and Energy Metering Terminals
Electric, water and heat metering networks use RS-485 runs between a concentrator and remote meter registers, often outdoors or in shared utility rooms where ground offsets are significant. The SN65HVD21P provides the extended common-mode tolerance needed for these links while keeping the design simple, because one 8-pin PDIP device replaces separate driver and receiver packages and removes the need for an isolation barrier in short-run metering cabinets. The transceiver drives the differential pair directly, and the microcontroller on the meter handles frame timing, CRC and address polling.
پێشنیارکراو
Long-Distance Instrumentation to Remote Sensors
Remote pressure, temperature and flow transducers are often connected to a central data logger over cable runs of tens of metres or more. The SN65HVD21P is a good fit for this instrumentation because its extended common-mode range keeps the receiver operating across the ground shift introduced by long cable loops, and because the through-hole PDIP package is common on logger and signal-conditioning boards. Termination resistors at both cable ends and a fail-safe bias network on the logger keep the idle bus state defined, so the receiver output never floats when the sensor is silent.
پێشنیارکراو
Legacy Through-Hole Test and Measurement Equipment
Bench instruments, programmable power supplies and laboratory data acquisition units built in the through-hole era commonly use an 8-pin PDIP RS-485 socket for instrument control. The SN65HVD21P fits those instruments directly, avoiding a board respin when a faster or more tolerant interface is required, and it lets modern USB-to-RS-485 adapters talk to legacy instruments over long bench cables. Because the device is a single half-duplex transceiver with separate enable pins, the instrument firmware controls direction exactly as it would with a discrete driver and receiver pair.
پێشنیارکراو
کورتەی بەرهەمە پێشنیارکراوەکان
داتای سەرچاوەی ئەندازیاری بۆ SN65HVD21P — بەراوردکردن، ڕێنمایی دیزاین و زانیاری پابەندبوون.
ڕێنمایی هەڵبژاردن
بەراوردکردن لەگەڵ جێگرەوەکان
| پارامەتر | ئەم بەرهەمە | SN65HVD22P | SN65HVD23P | SN65HVD26P | MAX485EPA | SP485EEN | ADM485JN |
|---|---|---|---|---|---|---|---|
| Package | PDIP-8 (P), through-hole | PDIP-8 (P) - same | PDIP-8 (P) - same | PDIP-8 (P) - same | PDIP-8 (P) - same | PDIP-8 (P) - same | PDIP-8 (P) - same |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Maxim Integrated | SGMicro | Analog Devices |
| Transceiver Configuration | 1/1, half duplex | 1/1, half duplex | 1/1, half duplex | 1/1, half duplex | 1/1, half duplex | 1/1, half duplex | 1/1, half duplex |
| Supported Standards | RS-485, RS-422 | RS-485, RS-422 | RS-485, RS-422 | RS-485, RS-422 | RS-485, RS-422 | RS-485 | RS-485, RS-422 |
| Enable Pin Control | Separate DE and RE inputs | Separate DE and RE inputs | Separate DE and RE inputs | Separate DE and RE inputs | Separate DE and RE inputs | Separate DE and RE inputs | Separate DE and RE inputs |
| Termination | External | External | External | External | External | External | External |
جیاکەرەوە سەرەکییەکان
- Extended common-mode rating for noisy, ground-shifted industrial buses (بەراورد بەMAX485EPA)
- Through-hole 8-pin PDIP package keeps legacy boards buildable (بەراورد بەSN65HVD3082EP)
- Single package provides both driver and receiver with separate enable pins (بەراورد بەADM485JN)
تێبینییەکانی دیزاین
Route the differential pair A and Y as a tightly coupled pair on a continuous ground plane, keep the driver output traces short and away from switching nodes, and connect the transceiver ground pin directly to the board ground plane with a short, low-inductance via. In a through-hole PDIP design keep the layout compact: the 8-pin package makes it easy to place the transceiver near the connector, and every extra centimetre of unpaired stub degrades the differential signal at higher data rates.
Decouple the supply pin with a local 0.1 uF ceramic capacitor placed as close to pin 8 as the layout allows, and add a bulk bulk electrolytic or larger ceramic close to the transceiver if the cable run is long. Because a half-duplex driver delivers a large current step when it switches the bus, inadequate local decoupling shows up as bus errors that look like noise problems rather than supply problems. Tie the transceiver ground to the board ground at a single point rather than routing it through the cable shield.
Two mistakes dominate RS-485 designs. First, terminating the bus at every node instead of only at the two physical ends over-damps the signal and reduces the differential swing at the far end. Second, leaving the bus without a fail-safe bias network lets the receiver output float when all drivers are disabled, which the host reads as random data. Apply termination only at the end nodes, add a bias network at one location, and confirm the enable logic so the driver is high-impedance except during transmit windows.
Half-duplex turnaround timing is the other frequent failure source. The host controller must wait for the driver to release the bus before the receiver output is valid, and the enable pins must never be driven in a way that overlaps two nodes transmitting. Use the receiver-enable and driver-enable inputs from the same GPIO or from a direction-controlled signal so there is no dead time ambiguity, and validate the worst-case delay at the maximum supported bus data rate before freezing the firmware timing.
زانیاری پابەندبوون
No explicit RoHS, REACH, lead-free or conflict-minerals statement appears in the manufacturer or distributor listings for this part. The device is an industrial interface IC and is not offered in an AEC-Q100 automotive-qualified variant in the listings reviewed.