SN65HVD24P - Extended Common-Mode RS-485 Transceiver, PDIP-8 | TI
MPN: SN65HVD24P ✓ چالاکSN65HVD24P گشتی
An RS-485 transceiver is a physical-layer interface IC that combines a differential line driver and a differential line receiver into one package, converting logic-level signals to balanced differential signalling and back. The RS-485 standard, defined in TIA/EIA-485-A, is the dominant industrial serial bus for long-distance, noise-immune multi-drop data links. A transceiver sits in the hierarchy above the line driver and line receiver, inside the broader class of interface ICs used in industrial automation, telecommunications and building-control equipment.
The HVD2x family, to which the SN65HVD24 belongs, is described by the manufacturer as offering performance far exceeding typical RS-485 devices while meeting all requirements of the TIA/EIA-485-A standard. Key differentiating features named in the manufacturer datasheet SLLS552E include operation over an extended range of common-mode voltages, high ESD protection, wide receiver hysteresis and failsafe operation. The wide receiver hysteresis improves noise immunity on long cables, while failsafe operation guarantees a defined output state when the bus is idle or a driver is unpowered.
Because the extended common-mode range widens the usable voltage span at the receiver inputs, the device tolerates large ground-potential differences between nodes on the same bus. This is the defining engineering benefit in multi-drop industrial networks where nodes are grounded at different points and where cables may run near high-energy switching equipment.
Typical applications include industrial process monitoring, factory automation buses, building-automation and HVAC controllers, motor-drive diagnostics, and long-cable telemetry links to remote sensor modules. The design is also used in smart metering and instrumentation front-ends where field cabling lengths exceed the short-distance limits of RS-232.
A key design consideration is that the driver and receiver enables are separate pins, allowing the transmitter to be tri-stated so that a multi-drop bus can be configured with exactly one active driver at a time. Keep the bus stub lengths short, terminate both ends of the differential pair with 120 ohm resistors, and route the A and B traces as a tight, length-matched pair to preserve the differential noise rejection the wide hysteresis is designed to exploit.
This page brings together the manufacturer device description, package and temperature details, drop-in replacement options on the same PDIP-8 footprint, a parameter-by-parameter comparison and practical bus-layout guidance so engineers can qualify the part without rebuilding the datasheet from scratch.
جێگرەوەکانی جێگۆڕکێ بۆ SN65HVD24P — هەمان پاکەت، پین بە پین گونجاو. ئەو بەشانەی پاکەتی جیاوازیان هەیە و پێویستیان بە چاککردنەوەی PCB هەیە لابراون.
جۆرەکان لەم زنجیرەیەدا
مۆدێلەکانی هەمان زنجیرە کە بە شێوەی ڕاستەوخۆ گونجاون لەگەڵ SN65HVD24P (هەمان شێوە و پێکهاتەی شوێن) — جیاوازە لە Package Type, Transceiver Configuration, RoHS Status.
SN65HVD24PE4
✅ جێگرەوەی ڕاستەوخۆ📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)
SN65HVD24PG4
✅ جێگرەوەی ڕاستەوخۆ📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)
ADM485JNZ
✅ جێگرەوەی ڕاستەوخۆپەیوەندی بۆ نرخ
بینینی داتاشیت →MAX485EPE+
✅ جێگرەوەی ڕاستەوخۆ📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)
MAX485CPE+
✅ جێگرەوەی ڕاستەوخۆ📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)
SN65HVD24P تایبەتمەندییەکان
| Technology | RS-485 |
| Device Type | Transceiver |
| Transceiver Configuration | 1 transmitter / 1 receiver (half duplex) |
| ڤۆڵتیەی دابینکردن | 5 V |
| پلەی گەرمیی کارکردن | -55 C to +125 C (-67 F to +257 F) |
| Package Type | PDIP-8 / SOIC-8, PLASTIC, MS-012AA |
| ژمارەی پینەکان | 8 |
| Standard Compliance | TIA/EIA-485-A |
| Common-Mode Range | Extended common-mode range (see manufacturer datasheet SLLS552E) |
| ESD Protection | High ESD protection (built-in, per manufacturer description) |
| Receiver Hysteresis | Wide receiver hysteresis |
| Failsafe Operation | Supported |
| Cable Length Capability | Designed for long-cable links |
| Extended Temperature Performance | To 125 C |
| Lifecycle Support | Enhanced Diminishing Manufacturing Sources (DMS) support; enhanced product-change notification |
| Assembly/Test Sites | One assembly/test site, one fabrication site |
| دۆخی RoHS | Compliant (RoHS variants - PE4 - offered) |
| جۆری دامەزراندن | Through-hole |
ڕێکخستنی پینی SN65HVD24P
| پین 1 | RO1 — Receiver output 1 |
| پین 2 | RE — Receiver enable (active low, per datasheet pin description table) |
| پین 3 | DE — Driver enable (active high, per datasheet pin description table) |
| پین 4 | GND — Ground |
| پین 5 | Y — Driver output (non-inverting bus node) |
| پین 6 | A — Driver/receiver bus input and output A |
| پین 7 | B — Driver/receiver bus input and output B |
| پین 8 | VCC — Power supply, 5 V |
بەکارهێنانە باوەکان
SN65HVD24P گونجاوە بۆ 6 بەکارھێنانs: Industrial Process Monitoring Bus, Factory Automation and Motor Drive Diagnostics, Building Automation and HVAC Controllers, Smart Metering and Utility Telemetry, Long-Cable Sensor and Telemetry Links, Test and Measurement Instrumentation.
Industrial Process Monitoring Bus
The SN65HVD24P suits RS-485 field buses linking pressure, flow and temperature transmitters back to a PLC or SCADA rack. Its extended common-mode range absorbs the ground-potential offsets that develop between cabinets wired to different building services, while the wide receiver hysteresis rejects the coupling noise typical of long shielded field cable. The 1/1 half-duplex architecture with separate driver-enable and receiver-enable pins lets one transceiver node share the pair, and the -55 C to +125 C rating covers unheated plant rooms and outdoor cabinets without derating.
پێشنیارکراو
Factory Automation and Motor Drive Diagnostics
In cell controllers and servo-drive service ports, the SN65HVD24P provides a robust host-side interface to fieldbus equipment over cables that run alongside variable-frequency drives and contactors. The manufacturer-stated high ESD protection and failsafe operation keep the node receiving valid data during and after the transients that occur when a drive is switched, and the failsafe output gives the controller a deterministic state when the bus is idle or a remote device is unpowered. The through-hole PDIP-8 package is convenient for retrofit boards and field-service spares.
پێشنیارکراو
Building Automation and HVAC Controllers
BAS/HVAC controllers commonly distribute setpoints and sensor data over RS-485 to room and air-handler units. The SN65HVD24P works well here because building controllers can be spread over several floors with different reference grounds, and the extended common-mode range keeps reception reliable where a standard transceiver would drop characters. Wide receiver hysteresis helps during compressor start-up transients, and the wide temperature range covers both plant rooms and unconditioned rooftop units. The single-pair differential connection also keeps wiring simple and shielded.
پێشنیارکراو
Smart Metering and Utility Telemetry
Utility metering endpoints and concentrators sit at the end of long outdoor cable runs where surge events and ground differences are common. The SN65HVD24P addresses the two classic problems of such links: it tolerates wide common-mode excursions at the receiver and presents a defined failsafe state when the pair is idle or the meter is powered down mid-transmission. The manufacturer datasheet notes limited built-in ESD protection on these devices, so a coordinated surge and TVS network ahead of the transceiver is essential; the IC then provides the common-mode and hysteresis margin that the external protection cannot.
پێشنیارکراو
Long-Cable Sensor and Telemetry Links
Remote sensor modules, radar units and instrumentation racks are often linked by cable runs of several hundred metres where reflections and coupled noise dominate. The SN65HVD24P keeps the link alive in that environment because the extended common-mode window tolerates voltage offsets introduced by cable resistance and earth potential differences, and the wide receiver hysteresis avoids false start bits when the differential signal is small. Terminating the bus at both ends with the standard 120 ohm networks and keeping the A and B traces paired on the board preserves that margin.
پێشنیارکراو
Test and Measurement Instrumentation
Lab and field test equipment often needs to talk to older RS-485 instruments that predate modern fail-safe and common-mode improvements. The SN65HVD24P bridges those instruments to modern control electronics with a single, well-understood 8-pin interface, and its high ESD protection plus extended temperature performance suit rack and field-cart use. Because the transceiver is a plain half-dupply half-duplex device with separate enable pins, it can be wired to a switchable driver path for automated loopback and handshaking tests, and the PDIP-8 package remains easy to socket in serviceable instrument designs.
پێشنیارکراو
کورتەی بەرهەمە پێشنیارکراوەکان
داتای سەرچاوەی ئەندازیاری بۆ SN65HVD24P — بەراوردکردن، ڕێنمایی دیزاین و زانیاری پابەندبوون.
ڕێنمایی هەڵبژاردن
بەراوردکردن لەگەڵ جێگرەوەکان
| پارامەتر | ئەم بەرهەمە | SN65HVD24PE4 | SN65HVD24PG4 | ADM485JNZ | MAX485EPE+ | MAX485CPE+ |
|---|---|---|---|---|---|---|
| Package | PDIP-8 (MS-012AA) | PDIP-8 (MS-012AA) - same | PDIP-8 (MS-012AA) - same | PDIP-8 - same 8-pin outline | PDIP-8 - same 8-pin outline | PDIP-8 - same 8-pin outline |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Analog Devices | Maxim Integrated | Maxim Integrated |
| Transceiver Configuration | 1 transmitter / 1 receiver, half duplex | 1/1 half duplex | 1/1 half duplex | 1/1 half duplex | 1/1 half duplex | 1/1 half duplex |
| Supply Voltage | 5 V | 5 V | 5 V | 5 V | 5 V | 5 V |
| Standard Compliance | TIA/EIA-485-A | TIA/EIA-485-A | TIA/EIA-485-A | RS-485 | RS-485 | RS-485 |
| Number of Pins | 8 | 8 | 8 | 8 | 8 | 8 |
جیاکەرەوە سەرەکییەکان
- Extended common-mode voltage range for long, noisy industrial cables (بەراورد بەMAX485EPE+)
- Wide receiver hysteresis and failsafe operation on the bus (بەراورد بەADM485JNZ)
- Wider temperature qualification for the same pinout (بەراورد بەSN65HVD24PE4)
تێبینییەکانی دیزاین
Route the A and B traces as a tightly coupled differential pair over a continuous reference plane, keeping the pair length matched and away from switching nodes, relay contacts and motor phase wiring. Terminate the bus at both physical ends with 120 ohm networks and avoid intermediate termination on long runs. Because the SN65HVD24P relies on its wide receiver hysteresis and extended common-mode margin, poor pair routing or floating stub branches will consume exactly the noise-immunity margin the part is designed to provide.
Place a 0.1 uF ceramic bypass capacitor as close as possible to the VCC pin and a bulk capacitor (1 uF to 10 uF, low ESR) close to the device for local energy storage. Because the driver can source significant current during bus transitions, keep the supply return path short and connect the transceiver ground directly to the board ground plane rather than daisy-chaining it through the cable shield. Verify the 5 V rail tolerance and ripple at the transceiver, since supply noise appears directly as bus noise.
The manufacturer datasheet SLLS552E notes that these devices have limited built-in ESD protection, so add an external TVS or surge-protection network ahead of the A/B pins for any cable that leaves the enclosure. Select protection devices with a working voltage compatible with the extended common-mode range and place them close to the connector so surge current is diverted to chassis or earth ground rather than through the PCB trace. Then verify with a conducted surge test, since reception faults often appear only during commutation events.
Do not enable more than one driver on the bus at a time. The SN65HVD24P has separate driver-enable and receiver-enable pins, and leaving DE asserted on several nodes lets two drivers fight each other, producing a dominant-current condition that can damage the outputs and corrupt every frame. Drive DE from the same arbitration logic that grants bus ownership, and hold DE de-asserted through power-up and reset so the device never drives a bus it does not own.
Check the enable pin polarity and the receiver fail-safe bias against your system logic before first power-up, since these families differ in whether the enables are active high or active low and whether a true fail-safe bias resistor is fitted. Use the pin-description table in the manufacturer datasheet rather than assuming a generic RS-485 convention. A wrong enable polarity usually shows up as a permanently dominant bus or a receiver output stuck at one level.
زانیاری پابەندبوون
RoHS-compliant ordering codes are offered for this family (PE4, PG4). The device is an industrial-temperature interface IC rated to 125 C and is not marketed as an AEC-Q100 qualified automotive part.