TJA1051TK/3/1J - 1 Mbps CAN Transceiver | NXP | 8-HVSON
MPN: TJA1051TK/3/1J ✓ چالاکTJA1051TK/3/1J گشتی
A CAN transceiver is the physical-layer interface between a CAN protocol controller and a two-wire CAN bus. It converts the controller's TXD and RXD signals into the differential CANH and CANL bus waveform and converts received bus levels back into a logic signal. Positioned within the interface-IC hierarchy, the TJA1051TK/3/1J connects a digital controller to a differential, noise-prone vehicle or industrial communication network.
Key features include enhanced electromagnetic compatibility and electrostatic-discharge performance relative to earlier CAN-transceiver generations. Selected TJA1051TK/3 variants also support VIO-level adaptation for direct connection to 3 V and 5 V microcontrollers. The transceiver exhibits passive behavior when unpowered, disengages from the bus with zero bus load, and supports predictable functional behavior across supply conditions. The /1 version designation identifies a dual-fab-sourced configuration, helping reduce supply-chain risk without changing the electrical specification.
The TJA1051 architecture provides differential transmit and receive functions for reliable high-speed CAN communication. Separate transceiver and logic-side supply domains allow VIO to match the controller's operating voltage while VCC supports the CAN transceiver supply. Its 3 mm by 3 mm HVSON package reduces board area compared with larger SOIC implementations, making the device suitable for compact automotive and industrial control electronics.
Typical applications include automotive CAN networks, industrial automation controllers, building automation equipment, embedded motor-control systems, and CAN-connected sensor nodes. At the PCB level, the device requires short CANH and CANL routing, a controlled return path, and placement close to the bus connector or transceiver termination network. The controller interface must also observe the input thresholds and timing specified by NXP.
For a new design, connect VIO to the microcontroller supply, place the manufacturer-recommended bypass capacitance close to VCC and VIO, and verify termination at both ends of the CAN bus. Confirm the 3 V to 5 V controller compatibility, 1 Mbps maximum data rate, EMC requirements, and exposed-pad thermal design before releasing the PCB.
This page combines the manufacturer datasheet, product-page information, package details, procurement data, and engineering guidance to support component selection, pin assignment, PCB implementation, and sourcing of the exact TJA1051TK/3/1J ordering code.
جێگرەوەکانی جێگۆڕکێ بۆ TJA1051TK/3/1J — هەمان پاکەت، پین بە پین گونجاو. ئەو بەشانەی پاکەتی جیاوازیان هەیە و پێویستیان بە چاککردنەوەی PCB هەیە لابراون.
جۆرەکان لەم زنجیرەیەدا
مۆدێلەکانی هەمان زنجیرە کە بە شێوەی ڕاستەوخۆ گونجاون لەگەڵ TJA1051TK/3/1J (هەمان شێوە و پێکهاتەی شوێن) — جیاوازە لە Package, Product Type, RoHS Status, Mounting Type, Automotive Qualification.
TJA1051TK/3/1
✅ جێگرەوەی ڕاستەوخۆ📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)
TJA1051TK/3/1J تایبەتمەندییەکان
| Product Type | High-speed CAN transceiver |
| Maximum CAN Data Rate | 1 Mbit/s |
| Transceiver Supply Voltage VCC | 4.5 V to 5.5 V |
| Logic Supply Voltage VIO | 3 V to 5 V |
| Controller Supply Compatibility | 3 V to 5 V microcontrollers |
| Bus Interface | 2-wire differential CAN bus |
| Transceiver Configuration | 1 transmitter and 1 receiver |
| پاکێج | 8-HVSON, 3 mm x 3 mm |
| جۆری دامەزراندن | Surface mount |
| Unpowered Behavior | Passive behavior with zero bus load |
| EMC Performance | Enhanced third-generation CAN-transceiver performance |
| ESD Performance | Enhanced bus-pin electrostatic-discharge performance |
| Logic Interface | TXD and RXD controller interface |
| Bus Output Signals | CANH and CANL differential outputs |
| Backwards Compatibility | Compatible with TJA1050 behavior |
| مەودای پلەی گەرمیی کارکردن | -40 C to +125 C |
| Manufacturing Configuration | Dual-fab-sourced /1 version |
ڕێکخستنی پینی TJA1051TK/3/1J
| پین 1 | VIO — Logic-side supply voltage for the TXD and RXD interface |
| پین 2 | RXD — CAN receive data output to the controller |
| پین 3 | GND — Ground connection |
| پین 4 | TXD — CAN transmit data input from the controller |
| پین 5 | VCC — CAN transceiver supply voltage |
| پین 6 | NC — Not connected |
| پین 7 | CANL — CAN bus low output and input |
| پین 8 | CANH — CAN bus high output and input |
بەکارهێنانە باوەکان
TJA1051TK/3/1J گونجاوە بۆ 6 بەکارھێنانs: Automotive CAN Network Nodes, Industrial Automation Controllers, Building Automation Equipment, Embedded Motor-Control Systems, CAN-Connected Sensor Hubs, Diagnostic and Service Interfaces.
Automotive CAN Network Nodes
The TJA1051TK/3/1J suits electronic control units connected to a 1 Mbit/s two-wire CAN network because it provides differential transmit and receive functions with enhanced third-generation EMC and ESD performance. Its VIO supply can operate from 3 V to 5 V, allowing the CAN interface to connect directly to logic devices using either common embedded supply levels. The 3 mm by 3 mm 8-HVSON package also reduces board area beside vehicle domain controllers, body modules, and sensor gateways. Place CANH and CANL on a tightly coupled pair, preserve a continuous return path, and use the NXP application guidance for bypass capacitance and exposed-pad thermal management.
پێشنیارکراو
Industrial Automation Controllers
The TJA1051TK/3/1J provides a compact physical-layer interface for industrial automation equipment using a 1 Mbit/s CAN bus. The 4.5 V to 5.5 V transceiver supply supports conventional industrial logic environments, while the separate 3 V to 5 V VIO domain permits connection to lower-voltage controller I/O. Predictable passive behavior when unpowered helps prevent the transceiver from interfering with other powered nodes during partial system shutdown. The small 8-HVSON package conserves board area in PLC modules, motor controllers, remote I/O units, and factory-floor gateways. Validate conducted and radiated emissions, ground offsets, bus termination, and fault tolerance in the completed enclosure and cable system.
پێشنیارکراو
Building Automation Equipment
The TJA1051TK/3/1J is appropriate for building-automation controllers that exchange commands and sensor data over a wired CAN network. Its 1 Mbit/s capability provides ample bandwidth for room controllers, lighting gateways, access-control terminals, and HVAC interface modules, while the 3 V to 5 V VIO compatibility supports low-power controller logic. The 3 mm by 3 mm HVSON package helps maintain compact terminal-board layouts. Designers should preserve the recommended CAN bus topology, use termination only at intended endpoint locations, isolate long cables as required by the installation, and test the finished product for immunity to elevator drives, LED drivers, switching power supplies, and other common building-floor interference sources.
پێشنیارکراو
Embedded Motor-Control Systems
The TJA1051TK/3/1J can connect a microcontroller-based motor-control module to a CAN network carrying commands, status, and diagnostic information. The separate VIO and VCC domains let the interface operate with a 3 V or 5 V controller while maintaining a 4.5 V to 5.5 V transceiver supply. At the maximum 1 Mbit/s bus rate, the device supports high-speed communication, but motor systems still require careful isolation between noisy power stages and the CAN network. Keep the CAN pair away from motor-phase traces, use a solid ground reference, select appropriate bus protection, and verify recovery after faults such as shorted battery rails, reversed supply, or dominant-bus conditions.
پێشنیارکراو
CAN-Connected Sensor Hubs
The TJA1051TK/3/1J provides a compact CAN interface for distributed sensor hubs that aggregate measurements from remote transducers. Its 3 V to 5 V VIO compatibility enables direct communication with low-power microcontrollers, and its passive behavior when unpowered allows a partly powered sensor node to avoid loading the bus. The 8-HVSON package helps reduce the footprint in compact sensor assemblies. Keep the transceiver and its bypass components close to the connector or board entry point, use a continuous reference plane beneath the differential pair, and define power-up and power-down behavior for the entire node. Environmental testing should cover temperature, humidity, vibration, ESD, and cable-borne transients appropriate to the installation.
پێشنیارکراو
Diagnostic and Service Interfaces
The TJA1051TK/3/1J can be used in compact diagnostic adapters and service interfaces that communicate with electronic modules over a vehicle or machine CAN bus. The 1 Mbit/s capability supports fast request-and-response traffic, while 3 V to 5 V controller compatibility simplifies connection to low-voltage bridge hardware. Predictable unpowered behavior is useful when the adapter is connected to an inactive network segment. The small HVSON package allows the interface to be placed near a sealed connector and reduces board volume. Designers should still include appropriate protection for external cables, confirm galvanic-isolation requirements, and verify signal levels, timing, and bus termination against the connected network specification.
پێشنیارکراو
کورتەی بەرهەمە پێشنیارکراوەکان
داتای سەرچاوەی ئەندازیاری بۆ TJA1051TK/3/1J — بەراوردکردن، ڕێنمایی دیزاین و زانیاری پابەندبوون.
ڕێنمایی هەڵبژاردن
بەراوردکردن لەگەڵ جێگرەوەکان
| پارامەتر | ئەم بەرهەمە | TJA1051TK/3/1 |
|---|---|---|
| Package | 8-HVSON (3x3) | 8-HVSON (3x3) |
| Brand | NXP Semiconductors | NXP Semiconductors |
| Maximum CAN Data Rate | 1 Mbit/s | 1 Mbit/s |
| Transceiver Supply Voltage | 4.5 V to 5.5 V | 4.5 V to 5.5 V |
| Logic Supply Voltage | 3 V to 5 V | 3 V to 5 V |
| Controller Interface | TXD and RXD | TXD and RXD |
| Bus Interface | 2-wire differential CAN | 2-wire differential CAN |
| Unpowered Behavior | Passive with zero bus load | Passive with zero bus load |
| EMC and ESD Features | Enhanced third-generation performance | Enhanced third-generation performance |
| Supply Configuration | Dual-fab-sourced /1 version | Dual-fab-sourced /1 version |
جیاکەرەوە سەرەکییەکان
- Pin-compatible dual-fab-sourced ordering option (بەراورد بەTJA1051TK/3/1)
- Compact 3 mm by 3 mm CAN interface (بەراورد بەTJA1051TK/3/1)
- Controller-level voltage flexibility (بەراورد بەTJA1051TK/3/1)
تێبینییەکانی دیزاین
Use the NXP land pattern for the 8-HVSON package rather than substituting a generic QFN footprint. Place the transceiver near the CAN connector or bus-entry region, route CANH and CANL as a short, tightly coupled differential pair, and provide an uninterrupted return path beneath the pair. Keep switching nodes, magnetic components, and high-current paths away from this pair. The 3 mm by 3 mm package offers little routing space, so coordinate the connector, protection devices, termination, and transceiver placement before routing the controller interface.
Connect VIO to the controller-side supply and VCC to the CAN transceiver supply, observing the specified 3 V to 5 V VIO range and 4.5 V to 5.5 V VCC range. Place the manufacturer-recommended bypass capacitors directly beside VCC and VIO with short ground returns. Decoupling for the two supply domains is important because VIO permits direct connection to 3 V or 5 V controller logic while VCC operates independently. Check the maximum VCC plus VIO voltage combination and all no-load, bus-idle, and fault conditions against the manufacturer datasheet.
The TJA1051TK/3/1J must maintain compatible logic levels across VIO, TXD, and RXD while controlling differential bus impedance and common-mode noise. Do not add long test pads or isolation gaps in the CANH and CANL paths. Keep the ground reference continuous, connect the exposed thermal area according to the package guidance, and provide thermal copper without introducing a return-path discontinuity. For long or externally accessible cables, add the protection scheme required by the system rather than assuming transceiver-level ESD performance alone satisfies the installation standard.
Avoid confusing TJA1051TK/3/1J with a TJA1051T order code because the package and logic-interface details differ. Also do not assume that the /1 manufacturing designation changes electrical performance; NXP describes it as a dual-fab-sourced configuration with identical packing and no technical difference. Confirm the complete ordering code, package dimensions, reel quantity, exposed-pad requirements, TXD polarity, RXD output behavior, and supply sequencing in the manufacturer datasheet before releasing a production BOM.
زانیاری پابەندبوون
No definitive RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals declarations were established for this exact ordering code. The TJA1051 family is intended for automotive and industrial CAN applications, but the exact qualification status must be confirmed for TJA1051TK/3/1J before production release.