INA128UA vs INA121UA Comparison
Detailed side-by-side comparison of INA128UA by Texas Instruments and INA121UA by Texas Instruments. Compare key specifications, electrical parameters, packaging, lifecycle status, pricing, and availability to determine the best component for your design requirements.
Specification Comparison
| Parameter | INA128UA | INA121UA |
|---|---|---|
| Brand | Texas Instruments | Texas Instruments |
| Category | Amplifier ICs | Amplifier ICs |
| Lifecycle Status | Active | Active |
| Product Type | Precision low-power instrumentation amplifier | Instrumentation Amplifier (FET-input) |
| Number of Channels | 1 channel | 1 |
| Common-Mode Rejection Ratio | 130 dB | — |
| Minimum Common-Mode Rejection Ratio | 120 dB | — |
| Maximum Offset Voltage | 50 uV | — |
| Maximum Offset Voltage Drift | 0.5 uV/degC | — |
| Maximum Input Bias Current | 5 nA | — |
| Quiescent Current | 700 uA | ±450 uA |
| Gain Range | 1 to 10,000 V/V | 1 V/V to 10,000 V/V (external resistor) |
| Gain-Bandwidth Product | 1.3 MHz | — |
| Bandwidth at Gain 100 | 200 kHz | — |
| Input Protection Range | -40 V to +40 V | — |
| Supply Voltage Range | -18 V to +18 V | ±2.25 V to ±18 V (dual) / 4.5 V to 36 V (single) |
| Minimum Dual Supply Voltage | -2.25 V to +2.25 V | — |
| Operating Temperature Range | -40 degC to +85 degC | — |
| Package | 8-pin SOIC, 3.90 mm width | 8-pin SOIC (D) |
| Mounting Type | Surface mount | Surface Mount |
| Architecture | Three-op-amp instrumentation amplifier with current-feedback input circuitry | — |
| RoHS Status | Compliant | Compliant (per DigiKey product page) |
| Bandwidth (G = 100) | — | 600 kHz |
| Slew Rate | — | 0.07 V/us |
| Input Bias Current | — | ±4 pA (max) |
| Input Offset Voltage | — | ±200 uV (max) |
| Input Offset Drift | — | ±2 uV/°C (max) |
| Input Voltage Noise Density | — | 100 nV/sqrt(Hz) [DATA_NEEDED: confirmation of exact frequency] |
| CMRR | — | 106 dB (min) |
| Nonlinearity (G = 100) | — | 0.001% (max) |
| Input Protection | — | ±40 V differential and common-mode |
| Operating Temperature | — | [DATA_NEEDED: confirmed range] |