| Parameter | INA141PA | INA126P |
|---|---|---|
| Brand | Texas Instruments | Texas Instruments |
| Category | Amplifier ICs | Amplifier ICs |
| Lifecycle Status | Active | Active |
| Product Type | Precision instrumentation amplifier | Precision micropower instrumentation amplifier |
| Gain | 10 V/V or 100 V/V | — |
| Architecture | Three-op-amp instrumentation amplifier | Two-op-amp instrumentation amplifier |
| Input Protection | ±40 V | — |
| Supply Range | ±18 V | — |
| Offset Voltage | 50 µV maximum | — |
| Offset Drift | 0.5 µV/°C maximum | — |
| Input Bias Current | 5 nA maximum | — |
| Common-Mode Rejection | 117 dB minimum | — |
| Bandwidth at Gain 100 V/V | 200 kHz | — |
| Quiescent Current | [DATA_NEEDED: quiescent current] | 175 µA/channel typical |
| Operating Temperature | -40 °C to +85 °C | — |
| Package | 8-pin plastic DIP | 8-pin PDIP |
| Mounting Type | Through-hole | Through-hole |
| Number of Circuits | 1 circuit | — |
| RoHS Status | [DATA_NEEDED: RoHS status] | [DATA_NEEDED: RoHS status] |
| REACH Status | [DATA_NEEDED: REACH status] | [DATA_NEEDED: REACH status] |
| Automotive Qualification | [DATA_NEEDED: AEC-Q100 qualification] | — |
| Maximum Supply Voltage | — | 36 V |
| Supply Voltage Range | — | ±1.35 V to ±18 V |
| Input Offset Voltage | — | 250 µV |
| Programmable Gain | — | 1, 10, 100, or 1000 using external resistor |
| Differential Signal Acquisition | — | Precision low-noise differential input |
| Channel Count | — | 1 channel |
| Terminal Count | — | 8 terminals |
| Package Shape | — | Rectangular DIP |
| Temperature Grade | — | Industrial |
| Application Class | — | Portable instrumentation and data acquisition |
| AEC-Q100 Qualification | — | [DATA_NEEDED: AEC-Q100 qualification] |