Specification Comparison
| Parameter | ISL6731BFBZ | UCC28019ADR |
|---|---|---|
| Brand | Renesas Electronics | Texas Instruments |
| Category | Voltage Regulators | DC-DC Converters |
| Lifecycle Status | Active | Active |
| Stock Status | In Stock | In Stock |
| Unit Price (USD) | $0.74 | $0.42 |
| Topology | Power Factor Correction (PFC), Continuous Conduction Mode (CCM) boost | Boost |
| Switching Frequency Range | 56.5 kHz to 70.7 kHz | — |
| Package | 14-SOIC (Pb-Free, M14.15) | SOIC-8 (D) |
| Operating Temperature Range | -40 C to +125 C | — |
| Gate Driver Output Voltage | 12.5 V internally clamped | — |
| Gate Drive Peak Current | 1.5 A (source/sink) | — |
| PFC Control Mode | Average current mode with multiplier | — |
| Reference Voltage | [DATA_NEEDED: internal reference value] | — |
| Protection Features | Cycle-by-cycle OCP, Over Power Limit (OPL), OTP, Input brownout, Output OVP, Output UVP | Output OVP/UVP, open-loop protection, overcurrent protection |
| Soft-Start | Integrated | — |
| Sync Input | Yes (ISET/SYNC pin) | — |
| Mounting Type | Surface Mount | Surface Mount |
| MSL Level | [DATA_NEEDED: MSL rating] | — |
| RoHS Status | Compliant (Pb-Free) | Compliant |
| Supply Voltage Range | [DATA_NEEDED: VCC range] | — |
| Control Mode | — | Continuous Conduction Mode (CCM), Average Current Mode |
| Switching Frequency | — | 65 kHz (fixed) |
| Maximum Duty Cycle | — | 98% (typ) |
| Power Range | — | 100 W to >2 kW |
| Input Voltage (Vin max) | — | 21 V |
| UVLO Thresholds (on/off) | — | 10.5 V / 9.5 V |
| Start-up Current (UVLO) | — | < 200 uA |
| Standby Mode Threshold | — | VSENSE < 0.77 V |
| Input Line Range | — | Wide-range universal AC |
| Packaging | — | Tape and Reel (DR suffix) |
| Operating Temperature | — | [DATA_NEEDED: operating temperature range] |
| Application Range | — | < 150 W applications; > 750 W applications |