ISO122JP vs ISO122U Comparison
Detailed side-by-side comparison of ISO122JP by Texas Instruments and ISO122U by Texas Instruments. Compare key specifications, electrical parameters, packaging, lifecycle status, pricing, and availability to determine the best component for your design requirements.
Specification Comparison
| Parameter | ISO122JP | ISO122U |
|---|---|---|
| Brand | Texas Instruments | Texas Instruments |
| Category | Amplifier ICs | Amplifier ICs |
| Lifecycle Status | Active | Active |
| Stock Status | In Stock | In Stock |
| Unit Price (USD) | $0.00 | $0.00 |
| Product Type | Precision isolation amplifier | — |
| Maximum Nonlinearity | 0.020% | 0.020% |
| Signal Bandwidth | 50 kHz | 50 kHz |
| Input Offset Voltage Drift | 200 V/°C | — |
| Power Supply Range | 4.5 V to 18 V | — |
| Bipolar Operation | ±10 V | — |
| VS1 Quiescent Current | 5 mA | 5 mA |
| VS2 Quiescent Current | ±5.5 mA | ±5.5 mA |
| High-Voltage Breakdown Rating | 1500 Vrms | — |
| Isolation Barrier | Matched differential capacitive barrier; manufacturer sources state 2 pF in the product description | — |
| Gain Configuration | Fixed unity gain | Fixed unity gain |
| External Components Required | None required for operation | None |
| Input and Output Isolation | Galvanic isolation between input and output sections | — |
| Package | 8-PDIP | 8-pin SOIC |
| Mounting Type | Through-hole | Surface mount |
| Signal Transmission Method | Duty-cycle modulation and demodulation across the capacitive barrier | — |
| Manufacturer Product Availability | Available in 16-pin plastic DIP and 28-lead plastic surface-mount package families | — |
| RoHS | [DATA_NEEDED: RoHS status] | — |
| REACH | [DATA_NEEDED: REACH status] | — |
| AEC-Q100 | [DATA_NEEDED: automotive qualification status] | — |
| Device Type | — | Precision isolation amplifier |
| Number of Channels | — | 1 circuit |
| Input Signal Range | — | ±10 V |
| Input Offset-Voltage Drift | — | 200 V/°C |
| Isolation Voltage | — | 1500 Vrms |
| Power-Supply Range | — | 4.5 V to 18 V |
| High-Voltage Breakdown Test Coverage | — | 100% |
| Operating Voltage | — | ±4.5 V to ±18 V |
| RoHS Status | — | [DATA_NEEDED: RoHS compliance status] |
| Operating Temperature Range | — | [DATA_NEEDED: operating temperature range] |