Parameter MAX1225CTC+ MAX1202ACAP
Brand Maxim Integrated Maxim Integrated
Category ADC/DAC ADC/DAC
Lifecycle Status Active Active
Stock Status In Stock In Stock
Unit Price (USD) $3.79 $7.17
Resolution 12 bits 12 bit
Sampling Rate 1.5 Msps (max) 133 kSPS
Number of Channels 1 (true-differential) —
Input Type True differential —
Architecture SAR (Successive Approximation Register) —
Supply Voltage 2.7 V to 3.6 V (single 3V supply) —
Supply Current (active) 3 mA (typ) at 1.5 Msps —
Supply Current (shutdown) 1 uA (max) —
Input Voltage Range ±VREF (differential) —
Internal Reference 2.5 V —
External Reference Range 1 V to VDD —
INL (Integral Nonlinearity) ±1 LSB (max) —
DNL (Differential Nonlinearity) ±1 LSB (max, no missing codes) —
SNR 70 dB (typ) —
SINAD 69 dB (typ) —
SFDR 86 dBc (typ) —
THD -84 dB (typ) —
Aperture Delay 15 ns (typ) —
Serial Interface SPI/QSPI/MICROWIRE-compatible SPI/QSPI/MICROWIRE-compatible
Operating Temperature Range -40 C to +85 C —
Package 12-pin TQFN, 4 mm x 4 mm with exposed pad 20-pin SSOP (5.3 mm body)
Mounting Type Surface Mount Surface Mount
RoHS Status Compliant Check suffix: 'CAP' (non-RoHS) vs 'CAP+' (RoHS)
MSL Level 1 —
Number of Input Channels — 8 single-ended / 4 differential
Converter Type — SAR (Successive Approximation)
Analog Supply Voltage — +5V (single) or ±5V (dual)
Digital Supply Voltage — +2.7V to +5.25V
Active Supply Current — 1.5 mA
Power-Down Current — 2 µA
Input Range — 0V to +5V unipolar; ±5V bipolar with dual supply
Integral Non-Linearity (INL) — ±1 LSB (max)
Differential Non-Linearity (DNL) — ±1 LSB (max)
Reference — Internal 2.5V (external optional)
Track-and-Hold — Internal, 1.5 µs acquisition
Operating Temperature — 0C to +70C (commercial, A grade)