MAX187CEWE vs XRD87L75AIP-F Comparison
Detailed side-by-side comparison of MAX187CEWE by Maxim Integrated and XRD87L75AIP-F by MaxLinear. Compare key specifications, electrical parameters, packaging, lifecycle status, pricing, and availability to determine the best component for your design requirements.
Maxim Integrated
MAX187CEWE - 12-Bit 75kSPS Serial ADC, 16-SOIC | Maxim Integrated
MAX187CEWE ✓ ActiveSpecification Comparison
| Parameter | MAX187CEWE | XRD87L75AIP-F |
|---|---|---|
| Brand | Maxim Integrated | MaxLinear |
| Category | ADC/DAC | ADC/DAC |
| Lifecycle Status | Active | Obsolete |
| Stock Status | In Stock | In Stock |
| Unit Price (USD) | $10.55 | $4.15 |
| Resolution | 12 bits | 8 bit |
| Architecture | SAR (Successive Approximation) | 2-step Flash |
| Sampling Rate (max) | 75 kSPS | — |
| Number of Inputs | 1 (single-ended) | — |
| Analog Input Range | 0 V to +5 V | 0 V to VDD |
| Supply Voltage | +4.75 V to +5.25 V (single +5 V supply) | 3.3 V (single) |
| Operating Supply Current | 1.5 mA (typ, during conversion) | — |
| Shutdown Current | 10 µA | — |
| Conversion Time | 8.5 µs | — |
| Track/Hold Acquisition | 1.5 µs | — |
| Integral Nonlinearity (max) | ±1 LSB | — |
| Reference | Internal 4.096 V buffered (MAX187); external required for MAX189 | — |
| Digital Interface | SPI / QSPI / MICROWIRE-compatible serial | Parallel |
| Operating Temperature Range | -40 °C to +85 °C (C grade) | — |
| Package | 16-pin wide-body SOIC ("WE") | 20-pin PDIP |
| Mounting Type | Surface Mount | Through-Hole |
| MSL Level | 1 (unlimited floor life at <30 °C / 85% RH, per JEDEC J-STD-020) | — |
| RoHS Status | Non-compliant (legacy "CEWE" suffix, pre-2011 lead-finish; + suffix variants are RoHS-compliant) | Compliant (Pb-free variant -F) |
| Sampling Rate | — | 10 MSPS |
| Number of Channels | — | 1 |
| Reference Input Range | — | 1 V to VDD |
| Power Dissipation | — | 25 mW typical (excluding reference) |
| Sample-and-Hold | — | Internal |
| Latch-Up | — | Latch-up free CMOS |
| Operating Temperature | — | [DATA_NEEDED: operating temperature range] |