MAX196AEAI vs MAX199BEAI Comparison

Detailed side-by-side comparison of MAX196AEAI by Analog Devices and MAX199BEAI by Maxim Integrated. Compare key specifications, electrical parameters, packaging, lifecycle status, pricing, and availability to determine the best component for your design requirements.

Specification Comparison

Parameter MAX196AEAI MAX199BEAI
Brand Analog Devices Maxim Integrated
Category ADC/DAC ADC/DAC
Lifecycle Status NRND Active
Stock Status In Stock In Stock
Unit Price (USD) $21.50 $14.95
Resolution 12 bit 12 bits
Sampling Rate 100 kSPS 100 kSPS
Number of Input Channels 6 (single-ended) —
Architecture SAR (Successive Approximation Register) DAS —
Input Range (MAX196) ±10V, ±5V, 0 to 10V, 0 to 5V (software-selectable per channel) —
Input Range (MAX198) ±4V, 0 to 4V (software-selectable per channel) —
Input Overvoltage Protection ±16.5 V continuous ±16.5 V (any channel, with power on or off)
Supply Voltage +4.75 V to +5.25 V (single +5V supply) +5 V single supply
Supply Current (operating) [DATA_NEEDED: IDD operating] —
Internal Reference 4.096 V (buried Zener) —
External Reference Option Yes (REFADJ pin) —
Linearity (A grade) ±1/2 LSB —
Interface Parallel (8/16-bit bus compatible, three-state) —
Logic Compatibility TTL/CMOS TTL/CMOS compatible inputs and outputs
Package 28-pin SSOP (EAI suffix) 28-pin SSOP
Operating Temperature (EAI grade) -40C to +85C (industrial) —
Mounting Type Surface Mount Surface Mount
RoHS Status Compliant (verified for + suffix variant; non-+ variant status: unknown) [DATA_NEEDED: RoHS compliance status for this suffix]
Number of Analog Input Channels — 8
Input Voltage Ranges — ±4 V, ±2 V, +4 V, +2 V (software-selectable)
Supply Current — [DATA_NEEDED: operating supply current]
Internal Reference Voltage — 4.096 V
External Reference Input — Yes (can overdrive internal reference)
Digital Interface — 8-bit three-state data bus with 4-bit address/data-multiplexed option (8+4)
Conversion Architecture — SAR (successive approximation) with track/hold
Operating Temperature — -40 °C to +85 °C (industrial, E suffix)
Throughput Settling Time — [DATA_NEEDED: acquisition + conversion time per sample]

Datasheets & Resources