MAX198AENI vs MAX198ACNI Comparison
Detailed side-by-side comparison of MAX198AENI by Maxim Integrated and MAX198ACNI by Analog Devices. Compare key specifications, electrical parameters, packaging, lifecycle status, pricing, and availability to determine the best component for your design requirements.
Specification Comparison
| Parameter | MAX198AENI | MAX198ACNI |
|---|---|---|
| Brand | Maxim Integrated | Analog Devices |
| Category | ADC/DAC | ADC/DAC |
| Lifecycle Status | Active | Obsolete |
| Stock Status | In Stock | In Stock |
| Unit Price (USD) | $10.95 | $9.80 |
| Architecture | Data Acquisition System (DAS) - 8-channel 12-bit ADC | SAR (Successive Approximation Register) |
| Resolution | 12 bits | 12 bit |
| Number of Input Channels | 8 single-ended | — |
| Conversion Rate | 100 ksps (max) | — |
| Input Voltage Range | ±4.18 V (bipolar) | — |
| Analog Supply Voltage | ±5 V (single +5 V supply) | — |
| Digital Supply Voltage | +5 V | — |
| Analog Supply Current | 6 mA at 100 ksps | — |
| Internal Reference Voltage | 4.18 V ±1% | 4.096 V |
| Reference Drift | 35 ppm/°C | — |
| Relative Accuracy (INL) | ±0.5 LSB (max) | — |
| Overvoltage Protection | ±16.5 V | — |
| Data Bus Width | 12-bit parallel | — |
| Bus Interface Compatibility | 80C31, 68HC11, TTL/CMOS logic | — |
| Package | 28-pin PDIP (DIP-28, 300 mil) | 28-pin PDIP (N) |
| Operating Temperature | -40 °C to +85 °C | — |
| Mounting Type | Through-Hole | Through-Hole (THT) |
| Manufacturer | — | Analog Devices (formerly Maxim Integrated) |
| Product Type | — | Data Acquisition System (DAS) / Multi-Channel SAR ADC |
| Number of Channels | — | 6 single-ended or 3 differential |
| Sampling Rate | — | 100 ksps |
| Supply Voltage | — | +5 V single supply |
| Analog Input Range (MAX198) | — | 0 to 10 V / 0 to 5 V / ±10 V / ±5 V / 0 to 4 V / ±4 V (software programmable) |
| Digital Interface | — | Parallel, 8/16-bit bus compatible, three-state I/O |
| Logic Compatibility | — | TTL/CMOS |
| Integral Non-Linearity (INL) | — | ±0.5 LSB (A grade) |
| Power Dissipation (active) | — | 60 mW typical |
| Power Dissipation (power-down) | — | < 1 mW |
| Operating Temperature Range | — | 0 °C to +70 °C (C suffix, commercial) |
| MSL Level | — | 1 (unlimited) |
| RoHS Status | — | [DATA_NEEDED: RoHS status of the bare CNI suffix] |