MPX4250AP vs MPX4250A Comparison
Detailed side-by-side comparison of MPX4250AP by NXP Semiconductors and MPX4250A by NXP Semiconductors. Compare key specifications, electrical parameters, packaging, lifecycle status, pricing, and availability to determine the best component for your design requirements.
Specification Comparison
| Parameter | MPX4250AP | MPX4250A |
|---|---|---|
| Brand | NXP Semiconductors | NXP Semiconductors |
| Category | Pressure Sensors | Pressure Sensors |
| Lifecycle Status | Active | NRND |
| Stock Status | In Stock | In Stock |
| Unit Price (USD) | $8.10 | $8.95 |
| Pressure Type | Absolute (Manifold Absolute Pressure) | — |
| Pressure Range | 20 kPa to 250 kPa (2.9 psi to 36.26 psi) | 20 kPa to 250 kPa (2.9 PSI to 36.3 PSI) |
| Pressure Range - Barometric Reference | 0 kPa to 250 kPa absolute (internal vacuum reference) | — |
| Supply Voltage | 5.0 V nominal (4.85 V to 5.35 V ratiometric) | 4.85 V to 5.35 V (5.0 V typical) |
| Output Type | Analog, ratiometric | Analog, ratiometric to supply voltage |
| Output Voltage Range | 0.2 V to 4.9 V | 0.2 V to 4.9 V (at 5.0 V supply) |
| Full-Scale Span (VFSO) | 4.6 V typical | — |
| Supply Current | [DATA_NEEDED: supply current] | [DATA_NEEDED: supply current at 5 V] |
| Accuracy | [DATA_NEEDED: total error %] | — |
| Sensitivity | Approx. 20 mV/kPa (linear, ratiometric) | Approx. 18.4 mV/kPa (at Vsup = 5.0 V) |
| Operating Temperature | -40C to +125C | -40 C to +125 C |
| Storage Temperature | [DATA_NEEDED: storage temperature range] | [DATA_NEEDED: storage temperature range] |
| Package | 6-SIP Module (6-pin SIP, through-hole, tube inlet) | — |
| Tube Inlet | Male 0.19 inch (4.93 mm) outer diameter | — |
| Port Style | Single axial tube port (barbed for 4.93 mm tube) | No port / non-port (basic element) |
| Mounting Type | Through-Hole SIP, PCB vertical mount | Through Hole, SIP |
| Pin Count | 6 (4 functional + 2 NC pins) | — |
| On-Chip Signal Conditioning | Yes (amplified, calibrated, temperature-compensated) | Yes (amplified, temperature-compensated, calibrated) |
| RoHS Status | [DATA_NEEDED: RoHS compliance] | Compliant (per NXP product page) |
| Lead-Free | Yes (per datasheet ordering information) | — |
| Sensor Type | — | Manifold Absolute Pressure (MAP), sealed vacuum reference |
| Maximum Overload Pressure | — | [DATA_NEEDED: maximum overload pressure] |
| Operating Pressure Range | — | 20 to 250 kPa absolute |
| Response Time | — | 1.0 ms |
| Package / Case | — | 6-SIP Module |