MPXV5004GP vs MPXV5004DP Comparison
Detailed side-by-side comparison of MPXV5004GP by NXP Semiconductors and MPXV5004DP by NXP Semiconductors. Compare key specifications, electrical parameters, packaging, lifecycle status, pricing, and availability to determine the best component for your design requirements.
NXP Semiconductors
MPXV5004GP - 0-3.92 kPa Gauge Pressure Sensor | NXP | SO-8
MPXV5004GP ✗ End of LifeSpecification Comparison
| Parameter | MPXV5004GP | MPXV5004DP |
|---|---|---|
| Brand | NXP Semiconductors | NXP Semiconductors |
| Category | Pressure Sensors | Pressure Sensors |
| Lifecycle Status | End of Life | Active |
| Stock Status | In Stock | In Stock |
| Unit Price (USD) | $8.20 | $7.40 |
| Pressure Type | Gauge (vented) | Differential (Dual Port, Same Side) |
| Pressure Range | 0 kPa to 3.92 kPa (0 to 0.57 PSI) | 0 kPa to 3.92 kPa (0 to 0.57 PSI) |
| Supply Voltage | 4.75 V to 5.25 V (nominal 5.0 V) | 4.75 V to 5.25 V (5 V typical) |
| Supply Current | 10 mA (typical) | 10 mA typical |
| Output Voltage Range | 1.0 V to 4.9 V | 1.0 V to 4.9 V at 5 V supply |
| Sensitivity | 1.0 V/kPa (nominal) | — |
| Offset Voltage at 0 kPa | 1.0 V (nominal) | — |
| Accuracy | [DATA_NEEDED: accuracy %FS over temperature] | ±1.5% Vfss typical (after auto-zero) |
| Operating Temperature Range | 0 C to +85 C | — |
| Storage Temperature | -40 C to +125 C | -30°C to +100°C |
| Response Time | [DATA_NEEDED: response time ms] | 1 ms typical |
| Package | 8-pin SOP (SOP-8), side port | 8-BSOP (CASE 1351-01), 12.06 mm width |
| Port Type | Side port, male 0.13" (3.17 mm) tube | Male Tube, 3.3 mm O.D., Dual Same-Side |
| Mounting Type | Surface Mount | Surface Mount |
| AEC-Q100 | Qualified (automotive grade) | — |
| RoHS Status | Compliant | Compliant |
| Technology | Piezoresistive MEMS with on-chip ASIC conditioning | — |
| Output Type | — | Analog, Ratiometric to VCC |
| Operating Temperature | — | 0°C to +85°C |
| Sensing Technology | — | Piezoresistive (MEMS strain gauge) |
| Signal Conditioning | — | On-chip amplified and calibrated |