OPA2107AU vs OPA2277UA Comparison
Detailed side-by-side comparison of OPA2107AU by Texas Instruments and OPA2277UA by Texas Instruments. Compare key specifications, electrical parameters, packaging, lifecycle status, pricing, and availability to determine the best component for your design requirements.
Texas Instruments
OPA2107AU - Dual 4.5MHz Precision DifET Op Amp | Texas Instruments
OPA2107AU ✓ ActiveSpecification Comparison
| Parameter | OPA2107AU | OPA2277UA |
|---|---|---|
| Brand | Texas Instruments | Texas Instruments |
| Category | Amplifier ICs | Amplifier ICs |
| Lifecycle Status | Active | Active |
| Stock Status | In Stock | In Stock |
| Unit Price (USD) | $9.36 | $2.95 |
| Amplifier Channels | 2 (Dual) | — |
| Gain Bandwidth Product | 4.5 MHz | — |
| Slew Rate | 18 V/us | 2 V/µs |
| Supply Voltage Range | +-4.5 V to +-18 V (9 V to 36 V total) | ±2 V to ±18 V |
| Input Bias Current | 10 pA max (4 pA typical) | — |
| Input Offset Voltage | 1 mV max | — |
| Offset Voltage Drift | 10 uV/C max | — |
| Output Current Per Channel | 40 mA | — |
| Open Loop Gain | 80 dB | — |
| Settling Time | Fast settling to 0.01% | — |
| Stability | Unity-gain stable | — |
| Input Type | DifET (FET) input | — |
| Package | 8-SOIC (0.154 in, 3.90 mm width), 8 pins | 8-pin SOIC (D) |
| Mounting Type | Surface Mount | Surface Mount |
| Operating Temperature | [DATA_NEEDED: operating temperature range] | — |
| Product Type | Precision DifET Operational Amplifier | — |
| Classification | Operational Amplifiers (General Purpose) | — |
| Number of Channels | — | 2 (Dual) |
| Amplifier Type | — | Precision Operational Amplifier |
| Input Offset Voltage (max) | — | 10 µV |
| Offset Drift (typ) | — | ±0.1 µV/°C |
| Open-Loop Gain (min) | — | 134 dB |
| Common-Mode Rejection (min) | — | 140 dB |
| Power-Supply Rejection (min) | — | 130 dB |
| Quiescent Current per Channel (typ) | — | 800 µA |
| Supply Voltage (Single) | — | 4 V to 36 V |
| Gain-Bandwidth Product | — | 1 MHz |
| Output Swing (RL=2 kΩ, ±15V) | — | ±14 V (within 1 V of rails) |
| Operating Temperature Range | — | -40°C to +125°C |
| MSL Level | — | 3 (168 hours) |
| RoHS Status | — | Compliant |