製品 (39,000+)

INA125U - Precision Bridge Amplifier, 10V Ref | Texas Instruments
INA125U

INA125U - Precision Bridge Amplifier, 10V Ref | Texas Instruments

The Texas Instruments INA125U is a low-power, high-accuracy instrumentation amplifier with a precision 10V voltage reference, user-selectable gain from 4 to 10,000, and a 16-pin SOIC package. It combines bridge excitation and differential-input amplification on one integrated circuit, making it suitable for strain-gauge, pressure-transducer, and other bridge-sensor signal chains. An instrumentation amplifier is a specialized differential amplifier designed for sensors whose useful output is small and appears across two input terminals. Its internal architecture provides high input impedance, accurate differential gain, and strong common-mode rejection. The INA125 adds a precision reference output, allowing a bridge circuit to be excited and its output measured relative to a stable midpoint. The INA125U offers a 2.7V to 36V supply range, low 460µA quiescent current, maximum 250µV input offset voltage, maximum 2µV/°C offset drift, and a sleep mode. A single external resistor sets the gain, while the integrated amplifier can provide 150kHz bandwidth according to the retrieved product data. These features balance precision, power consumption, and measurement speed for portable and industrial instrumentation. Electrically, the device is intended for bridge outputs and other low-level differential sources. Input common-mode range, reference accuracy, gain error, and maximum input voltage must be checked against the actual bridge excitation and sensor output. The SOIC package also requires careful attention to ground return paths and supply decoupling when low-level signals are measured. Typical uses include quarter-bridge and full-bridge strain sensors, load-cell front ends, pressure and force measurement, biomedical instrumentation, industrial process controls, and precision data-acquisition systems. The 10V reference can simplify excitation when the sensor and measurement chain require a defined bridge supply. The most important design consideration is preserving common-mode and differential signal integrity. Place input and reference grounding deliberately, use low-noise supply bypass capacitors, and verify that the selected gain resistor stays within its recommended range. This page combines verified manufacturer and distributor information with practical application guidance and explicit data gaps rather than estimating unprovided specifications.

見積もり お問い合わせ
INA125UA - Precision Bridge Instrumentation Amplifier | TI
INA125UA

INA125UA - Precision Bridge Instrumentation Amplifier | TI

The Texas Instruments INA125UA is a low-power, high-accuracy instrumentation amplifier with an integrated precision voltage reference, one differential input channel, and a 16-pin SOIC package. A single external resistor sets the gain from 4 to 10,000 V/V, while the integrated bridge excitation and reference circuitry support complete sensor-conditioning solutions in one IC. An instrumentation amplifier is a specialized analog signal-conditioning IC designed to amplify small differential voltages while rejecting common-mode interference. Its functional hierarchy is instrumentation amplifier, differential amplifier, analog front end, and signal-conditioning IC. This device is particularly useful when a sensor produces a small differential output and the measurement environment contains noise, ground-potential differences, or substantial common-mode voltage. The INA125UA combines differential-input amplification, adjustable gain, bridge excitation, and a precision voltage reference in one package. Its gain range of 4 to 10,000 V/V allows the same device family to serve strain-gauge, pressure-sensor, and resistive-bridge systems. The single-resistor gain-setting arrangement simplifies calibration and reduces the number of external components required for many precision measurement circuits. The device is laser-trimmed for accuracy, and the family operates across a supply range of 2.7 V to 36 V. The INA125UA ordering option is supplied in a 16-pin SOIC package for surface-mount assembly. The integrated reference can support excitation or output-referencing requirements where an external precision reference would otherwise increase component count and introduce another error source. Typical uses include strain-gauge load cells, resistive pressure and temperature sensors, current-shunt instrumentation, industrial process monitoring, and precision laboratory measurement systems. It is especially appropriate when differential signal integrity, adjustable gain, and integrated bridge excitation are needed within one analog front end. The wide supply range also allows operation from low-voltage portable systems through higher-voltage industrial measurement equipment. Designers should follow the TI datasheet for the exact gain-resistor equation, reference-output behavior, input and output range, supply decoupling, and common-mode limitations. Place bypass capacitors close to the supply pins, keep sensitive differential routes compact and symmetric, and verify that transducer excitation, input common-mode voltage, output swing, and gain remain within their permitted operating limits. This page organizes the INA125UA specifications, pin package, application guidance, comparison parameters, and drop-in alternatives. It also identifies the engineering trade-offs between same-footprint family members and provides sourcing workflows for price, availability, and lead-time requests.

見積もり お問い合わせ
INA126P - 36V MicroPower Precision INA | Texas Instruments
INA126P

INA126P - 36V MicroPower Precision INA | Texas Instruments

The Texas Instruments INA126P is a precision micropower instrumentation amplifier rated for a 36 V maximum supply, with 175 µA quiescent current, 250 µV input offset voltage, and gain values set by an external resistor. It is supplied in an 8-pin PDIP package for through-hole industrial, portable, and measurement-instrumentation designs. An instrumentation amplifier is a differential analog-front-end IC that amplifies the voltage difference between two inputs while rejecting common-mode interference. INA126 belongs to the instrumentation-amplifier hierarchy within operational amplifiers and analog signal-chain ICs. Its two-op-amp architecture supports accurate, low-noise acquisition from sensors, bridges, and low-level transducers, especially where power consumption and input precision are important. The verified features include 250 µV offset, 175 µA typical quiescent current, and operation from ±1.35 V to ±18 V, corresponding to a stated 36 V maximum supply condition. The INA126 family also provides programmable gains of 1, 10, 100, or 1000 through the external gain resistor. These values make it suitable for battery-powered instrumentation, industrial measurement, portable diagnostics, and sensor interfaces where common-mode rejection and low bias current are more valuable than wide bandwidth. The device uses a two-op-amp internal architecture rather than a three-op-amp topology, helping keep power consumption low. Because the gain depends on the external resistor and its matching, PCB resistor placement, source impedance balance, input filtering, grounding, and reference-connection practices directly influence accuracy. The 8-pin PDIP package is mechanically straightforward for through-hole assembly but requires adequate lead spacing and clean soldering practice. Typical applications include bridge-based pressure and load measurement, low-level sensor conditioning, portable medical or industrial instrumentation, battery-operated data acquisition, and differential signal acquisition where a precision offset and low supply current are required. For single-supply systems, the output-reference arrangement must be designed to keep the output within the input and output common-mode limits. The principal design trade-off is the relatively modest micropower-focused feature set versus higher-bandwidth or lower-noise instrumentation amplifiers. Confirm supply voltage, input range, gain resistor, output swing, reference connection, and common-mode limits against the manufacturer datasheet before committing a PCB design. This page combines verified manufacturer and distributor information with design guidance, selection criteria, and same-package comparison context for engineers evaluating the INA126P.

見積もり お問い合わせ
INA126PA - 36V Micropower Instrumentation Amplifier | TI
INA126PA

INA126PA - 36V Micropower Instrumentation Amplifier | TI

The Texas Instruments INA126PA is a single-channel, precision micropower instrumentation amplifier with a 36 V maximum supply rating, 250 µV input offset voltage, 175 µA quiescent current per channel, and an 8-pin PDIP package. It is designed to acquire accurate, low-noise differential signals while consuming very little power. The two-operating-amplifier architecture supports common-mode rejection and differential signal conditioning in compact, portable, and industrial instrumentation systems. An instrumentation amplifier is a specialized amplifier category used to amplify the difference between two input signals while rejecting common-mode voltage. Within the amplifier hierarchy, an instrumentation amplifier is a precision analog amplifier, while an operational amplifier is a more general-purpose building block. The INA126PA belongs to the micro-power instrumentation-amplifier family and combines differential input measurement, adjustable gain, and low bias current in one integrated circuit. The principal advantages are low power consumption, low offset voltage, a wide operating-supply range of ±1.35 V to ±18 V, and operation from a single supply down to 2.7 V. According to the manufacturer datasheet, the device uses 175 µA per channel and provides a gain adjustment range of 1 V/V to 1000 V/V. These characteristics suit battery-powered and portable measurement systems where amplifier power can materially affect available operating time. The INA126PA uses a two-operating-amplifier architecture for accurate, low-noise differential-signal acquisition. Its instrumentation-amplifier function is useful when the wanted signal is smaller than the voltage shared by both input nodes. The low 175 µA quiescent current is particularly important in portable instrumentation and data-acquisition systems, while the 250 µV offset specification supports precision measurement of small differential voltages. Typical applications include portable sensor acquisition, industrial process measurement, battery-operated diagnostic equipment, low-current transducers, and differential voltage sensing. In each case, the device can condition a low-level differential input before it reaches an ADC or another signal-processing stage. Its single- and dual-supply flexibility allows it to be used with compact analog systems operating from low-voltage sources as well as higher-voltage industrial rails. Designers should verify the exact gain-setting resistor against the manufacturer gain table and preserve the input and reference-pin arrangements shown in the datasheet. The reference input should be connected to a defined low-impedance voltage, and unused inputs must not be allowed to float. PCB layout should keep the gain-setting resistor close to the device to minimize added noise and instability in sensitive measurement circuits. This product page consolidates verified manufacturer and distributor information, lifecycle guidance, package details, replacement analysis, and practical design guidance. It also distinguishes verified drop-in candidates from changes requiring a different package, helping engineers avoid confusing functional equivalence with literal PCB-level replaceability.

見積もり お問い合わせ
INA126U - 36V Micropower Instrumentation Amp | Texas Instruments
INA126U

INA126U - 36V Micropower Instrumentation Amp | Texas Instruments

The Texas Instruments INA126U is a single-circuit micropower precision instrumentation amplifier rated for a 36 V total supply, with 175 µA quiescent current per channel, 250 µV offset, and an 8-pin SOIC package. Its differential-input architecture supports accurate, low-noise signal acquisition where common-mode interference, source impedance mismatch, and power consumption must all be controlled. An instrumentation amplifier is a specialized amplifier and the final member of the signal-chain hierarchy: sensor output → differential input → instrumentation amplifier → ADC or measurement system. Unlike a general-purpose operational amplifier, an instrumentation amplifier internally supports high input impedance and accurate differential gain, reducing errors when both inputs originate from balanced sensors, resistive bridges, or shunt measurements. The INA126 family uses a two-op-amp architecture optimized for precision and micropower operation. Verified headline features include a 36 V maximum supply, 175 µA per-channel quiescent current, and 250 µV offset. The manufacturer describes the device for accurate, low-noise differential-signal acquisition across a wide operating voltage range of ±1.35 V to ±18 V. These properties suit portable instruments and low-power acquisition systems where battery energy is limited but input-referred accuracy remains important. The single amplifier in the INA126U also avoids the extra power and board area associated with an unnecessary dual channel. The INA126U can be configured through an external gain-setting resistor. Because its instrumentation-amplifier architecture rejects common-mode signals before they reach the output, it is particularly useful when the wanted differential signal is much smaller than the voltage shared by both inputs. Designers must still verify input and output common-mode limits, maximum differential input voltage, gain-bandwidth behavior, resistor tolerance, output swing, and the sensor output range for the intended supply voltage. Precision performance ultimately depends on resistor matching and careful grounding as well as the amplifier itself. Typical uses include battery-powered sensor interfaces, portable measurement instruments, current-shunt amplifiers, bridge-signal conditioning, and low-power data-acquisition front ends. The 175 µA per-channel quiescent current is particularly useful where idle current directly affects battery life. The 250 µV offset specification gives designers a defined input-referred error reference, while the 36 V supply capability supports higher-voltage industrial systems when the individual input and output ranges are observed. For PCB implementation, keep the external gain resistor close to the gain-setting pins, use a stable low-noise reference plane, and place input-protection capacitance only after checking its effect on bandwidth and transient response. Avoid long parallel input traces, maintain symmetric routing where practical, and provide local supply bypassing. Verify common-mode headroom at worst-case sensor voltage and load current rather than relying only on nominal supply conditions. This page combines verified manufacturer facts, distributor pricing, same-package alternatives, and application-oriented design guidance. It also distinguishes documented values from parameters requiring confirmation from the complete manufacturer datasheet, helping engineers move from component selection to a defensible low-power sensor-board design.

見積もり お問い合わせ
INA126UA - 36V Precision MicroPower Instrumentation Amplifier | TI
INA126UA

INA126UA - 36V Precision MicroPower Instrumentation Amplifier | TI

The Texas Instruments INA126UA is a single-channel precision instrumentation amplifier with a 36 V maximum supply, 175 µA quiescent current per channel, 250 µV input offset voltage, and an 8-pin SOIC package. It is designed for accurate, low-noise differential-signal acquisition where low power consumption and high common-mode rejection are important. An instrumentation amplifier is a differential-input amplifier optimized for measuring small signals embedded in larger common-mode voltages. Its internal gain stage rejects common-mode noise and converts the differential difference between two inputs into a single-ended output. The INA126 belongs to the broader hierarchy of instrumentation amplifier, precision amplifier, analog signal-conditioning IC, and semiconductor. The INA126UA uses a two-op-amp architecture with external gain-setting resistors. Its precision input offset voltage supports accurate bridge, current-sense, and sensor measurements, while the 175 µA per channel quiescent current suits battery-powered and portable equipment. The 250 µV input offset specification is particularly useful when the measured differential signal is small relative to the allowed error. The device supports supply voltages from 2.7 V to 36 V total, corresponding to the documented operating range of ±1.35 V to ±18 V. Its 200 kHz bandwidth suits relatively slow precision measurements rather than high-speed waveform capture. The two-op-amp topology balances low noise and low quiescent current with a practical gain-setting arrangement using an external resistor. Typical uses include strain-gauge and RTD signal conditioning, low-side current measurement, bridge excitation, biomedical instrumentation, and portable sensor acquisition. For bridge-based sensors, the instrumentation amplifier rejects ground offsets and common-mode interference before the signal reaches an ADC. For battery-powered systems, the 175 µA per channel current helps limit standby consumption. Choose the INA126UA when the design requires a precision single-channel amplifier with an 8-pin SOIC footprint and very low quiescent current. Verify the selected gain, output swing, supply voltage, bandwidth, and output-reference arrangement against the manufacturer datasheet. Input and reference pins should be routed away from switching nodes and noisy return currents. This page combines device specifications, verified drop-in alternatives, application guidance, package details, and selection trade-offs to help engineers evaluate the INA126UA before circuit implementation.

見積もり お問い合わせ
INA128HD - 130dB CMRR Low-Power Instrumentation Amplifier | TI
INA128HD

INA128HD - 130dB CMRR Low-Power Instrumentation Amplifier | TI

The Texas Instruments INA128HD is a precision, low-power instrumentation amplifier with 130 dB CMRR, 700 µA typical quiescent current, and a 1.3 MHz gain-bandwidth product, housed in an 8-pin SOIC package. It accepts input protection to ±40 V, supports supply voltages up to ±18 V, and uses one external resistor to set gain from 1 to 10,000. The INA128HD is the high-temperature member of the INA128-HT family and is intended for precision bridge, sensor, and low-level differential-signal measurement. An instrumentation amplifier is a specialized amplifier that amplifies the voltage difference between two inputs while rejecting signals common to both inputs. This three-operational-amplifier architecture belongs to the broader measurement-amplifier and analog-signal-conditioning hierarchy. It is especially useful when a small sensor voltage is mixed with a larger common-mode voltage and the measurement requires high input impedance, accurate differential gain, and low output offset. Key characteristics include 25 µV typical offset voltage, 93 dB minimum CMRR at gain settings of 100 or higher, a 4 V/µs slew rate, and a gain equation based on a 49.4 kΩ gain-setting resistor. Input bias current is listed as 50 nA typical. These features allow the INA128HD to preserve small differential signals while rejecting power-supply ripple, ground offsets, and other common-mode disturbances. The INA128 uses a current-feedback input stage to maintain usable bandwidth at higher closed-loop gains. A single resistor between the gain-setting terminals establishes the desired gain, while the internal amplifier stages provide differential sensing and single-ended output. The manufacturer describes the INA128-HT as a laser-trimmed design with low offset and high CMRR, making it appropriate for precision analog front ends where gain accuracy and signal purity are more important than minimum cost. Typical uses include Wheatstone bridge sensing, pressure and force measurement, biomedical instrumentation, industrial sensor acquisition, and low-level differential receiver circuits. The 8-pin SOIC package is also practical for high-density analog boards, although the specified operating temperature range and total input error should be checked against the mechanical and environmental requirements of the target equipment. For PCB design, place the gain resistor close to pins 1 and 8 to minimize parasitic resistance and instability. Keep input and reference-node routing away from switching nodes and high-current return paths. Check the maximum differential input voltage, common-mode range, supply limits, and output swing in the manufacturer datasheet before finalizing the sensor interface. This product page combines manufacturer specifications, sourcing guidance, application analysis, and same-package drop-in comparisons. It also highlights practical PCB and signal-integrity considerations that help engineers evaluate the INA128HD beyond a basic parametric component listing.

見積もり お問い合わせ
INA128P - 130dB CMRR Precision INA | Texas Instruments
INA128P

INA128P - 130dB CMRR Precision INA | Texas Instruments

The Texas Instruments INA128P is a precision, low-power instrumentation amplifier with 130 dB CMRR, a 700 µA quiescent current, and an 8-pin PDIP package. It provides 50 µV maximum offset voltage, 0.5 µV/°C maximum offset drift, 5 nA maximum input bias current, and 1.3 MHz bandwidth. The device accepts supply voltages from ±2.25 V to ±18 V and supports input protection to ±40 V. An instrumentation amplifier is a specialized amplifier-IC category designed to amplify small differential sensor signals while rejecting common-mode interference. INA128P belongs to the instrumentation-amplifier hierarchy, which also includes differential amplifiers and analog front ends for measurement systems. Its three-op-amp architecture provides accurate differential gain, high input impedance, and flexible gain selection with an external resistor. Key features include a low offset voltage of 50 µV maximum and low offset drift of 0.5 µV/°C maximum. The 130 dB CMRR figure minimizes errors when a sensor signal is small relative to its common-mode voltage. Current-feedback input circuitry preserves bandwidth at higher gain, including 200 kHz bandwidth at a gain of 100. Input bias current remains low at 5 nA maximum, which is valuable for high-impedance sensors. The INA128P uses a versatile three-op-amp instrumentation-amplifier architecture and is available in an 8-pin plastic DIP package. Its ±2.25 V to ±18 V supply range supports dual-supply analog systems and higher-voltage industrial interfaces. The specified operating temperature range is -40 °C to +85 °C. The low 700 µA quiescent current helps reduce power consumption in portable and low-power measurement equipment. Typical applications include bridge and strain-gauge signal conditioning, current measurement, biomedical instrumentation, industrial sensor interfaces, precision data acquisition, and laboratory measurement systems. The device is particularly suitable when common-mode rejection and low offset are more important than very high bandwidth. The manufacturer datasheet also identifies current-feedback input circuitry for improved high-gain bandwidth. When designing around INA128P, choose the external gain resistor carefully because it determines gain accuracy and stability. Keep input and feedback routing compact, observe the specified supply limits, and verify common-mode voltage, input protection, and output-swing requirements against the actual sensor and measurement chain. The INA128P is not a power semiconductor, so safe-operating-area data is not applicable. This page combines verified manufacturer specifications, distributor availability information, cross-reference results, and practical design guidance for engineers evaluating precision sensor-signal conditioning.

見積もり お問い合わせ
INA128PA - 130dB CMRR Low-Power INA | Texas Instruments
INA128PA

INA128PA - 130dB CMRR Low-Power INA | Texas Instruments

The Texas Instruments INA128PA is a precision, low-power instrumentation amplifier with 130 dB CMRR, 700 µA quiescent current, and an 8-pin PDIP package. It uses a versatile three-op-amp architecture to amplify small differential signals while rejecting common-mode interference. Its specified low offset voltage, low drift, low bias current, wide supply range, and protected inputs make it suitable for precision measurement systems. The device supports gains from 1 through 10,000 using one external gain-setting resistor and retains useful bandwidth at high gain. An instrumentation amplifier is a specialized analog amplifier optimized for measuring low-level differential signals in the presence of large common-mode voltages. Its internal three-op-amp arrangement provides high input impedance, accurate differential gain, and strong common-mode rejection without requiring matched external resistors. INA128PA belongs to the instrumentation-amplifier hierarchy, which sits within signal-conditioning and amplifier ICs used in instrumentation, industrial control, biomedical measurement, and test equipment. Verified features include a maximum input offset voltage of 50 µV, maximum input voltage drift of 0.5 µV/°C, maximum input bias current of 5 nA, minimum CMR of 120 dB, input protection to ±40 V, and a supply range up to ±18 V. The low quiescent current is 700 µA, making the device suitable for power-conscious precision analog systems. According to the verified TI product data, the INA128 family provides 200 kHz bandwidth at a gain of 100. The three-op-amp internal design uses current-feedback input circuitry to preserve bandwidth as gain increases. This architecture is important when the measured signal is small and the source impedance is not negligible: the low 5 nA maximum bias current reduces loading of high-resistance sensors. The 130 dB CMRR specification helps reject common-mode voltage produced by motor systems, mains-coupled noise, or long sensor cables. Typical uses include precision current sensing, bridge-transducer amplification, biomedical instrumentation, portable measurement, laboratory equipment, and industrial process monitoring. The part can operate from dual or single supplies as supported by the family documentation, but the exact operating modes and output-swing limits should be checked against the manufacturer datasheet before final design release. For PCB implementation, keep the gain resistor close to the gain-setting pins and use a quiet ground return for the signal path. Input filtering, common-mode voltage limits, output settling, and supply decoupling must be evaluated for the target gain and bandwidth. Do not assume that the protected input rating removes the need for external transient protection in every system. This page combines verified manufacturer and distributor information, package-specific identification, application guidance, and cautious replacement analysis. Values not explicitly verified in the supplied data remain marked for engineering review rather than estimated.

見積もり お問い合わせ
INA128U - 130dB CMRR Precision Instrumentation Amplifier | TI
INA128U

INA128U - 130dB CMRR Precision Instrumentation Amplifier | TI

The Texas Instruments INA128U is a precision, low-power, three-op-amp instrumentation amplifier with 130 dB CMRR, a 700 µA quiescent current, and an 8-pin SOIC package. It operates from ±2.25 V to ±18 V, supports gains from 1 to 100,000 through an external gain-setting resistor, and is designed for measuring small differential signals superimposed on large common-mode voltages. An instrumentation amplifier is a differential amplifier optimized for sensors and balanced signal chains. Its internal three-op-amp architecture provides high input impedance and accurate differential gain, making it more practical than connecting a general-purpose op amp directly to a balanced source. Within the signal-processing hierarchy, an instrumentation amplifier is a specialized amplifier IC, while the INA128U also belongs to the broader precision analog and low-power signal-conditioning family. Key characteristics include a maximum input offset voltage of 50 µV, maximum offset drift of 0.5 µV/°C, maximum input bias current of 5 nA, and input protection to ±40 V. Current-feedback input circuitry maintains useful bandwidth at higher gain, including approximately 200 kHz at a gain of 100. The low 700 µA supply consumption supports battery-powered and portable measurement systems where amplifier power can materially affect operating time. The INA128U uses an external resistor to establish gain, simplifying programming when only one gain is required. Its three-op-amp topology offers accurate gain control and strong common-mode rejection, but requires adequate layout discipline around high-impedance inputs and the gain resistor. Input and output filtering must be selected carefully because excessive capacitance can affect stability or reduce usable bandwidth. Typical applications include bridge-transducer and pressure-sensor interfaces, precision current measurement, biomedical instrumentation, industrial process monitoring, and low-level differential sensing. The INA128U is particularly appropriate where a small sensor signal must be measured accurately in the presence of a much larger common-mode voltage and where low quiescent current is more important than very high bandwidth. For reliable operation, keep input and gain-resistor connections short, provide adequate input and output decoupling, and verify stability with the actual source impedance and cable capacitance. If the input can exceed the supply rails, use the specified protection method rather than assuming ordinary op-amp input clamps can safely absorb the applied voltage. The effective system accuracy also depends on resistor tolerance and temperature coefficient. This product record combines verified manufacturer specifications, distributor references, package and sourcing information, alternative-part analysis, and application guidance. It is intended to help engineers locate the datasheet, compare genuine same-package choices, estimate fit, and identify the design details that are not visible from a distributor listing alone.

見積もり お問い合わせ
INA128UA - 130dB CMRR Low-Power Instrumentation Amplifier
INA128UA

INA128UA - 130dB CMRR Low-Power Instrumentation Amplifier

The Texas Instruments INA128UA is a precision, low-power instrumentation amplifier with 130 dB CMRR, 700 uA quiescent current, and 1.3 MHz gain-bandwidth performance in an 8-pin SOIC package. Maximum input offset voltage is 50 uV, while input bias current is limited to 5 nA, making the device suitable for precision sensor-signal conditioning. An instrumentation amplifier is a specialized amplifier that amplifies the difference between two input signals while rejecting common-mode interference. Its internal three-op-amp architecture provides high input impedance, controlled differential gain, and strong common-mode rejection. In the power-management hierarchy, the INA128 belongs to the amplifier IC category, where it converts low-level differential sensor outputs into stable signals suitable for measurement, conversion, or control systems. Key characteristics include an externally adjustable gain from 1 to 10,000 V/V, input protection to ±40 V, and operation across dual supplies of ±2.25 V to ±18 V. The 130 dB CMRR suppresses common-mode noise from sensors and long cables, while the 50 uV maximum offset limits measurement error. Its 700 uA quiescent current also makes it appropriate for compact, low-power instrumentation. The INA128 uses a versatile three-op-amp architecture with current-feedback input circuitry. This structure supports usable bandwidth even at high gain, including approximately 200 kHz at a gain of 100. A precision gain-setting resistor between the RG pins establishes the differential gain, allowing the same device family to serve bridge, current-shunt, and general differential-signal applications. Typical uses include precision bridge transducers, strain-gauge sensing, medical instrumentation, industrial process-control equipment, and low-level current measurement. The ±40 V input protection rating can simplify protection around sensor inputs, although system designers must still maintain appropriate common-mode and supply operating limits. Designers should keep the gain resistor close to the RG pins, provide stable reference and supply bypassing, and check input and output common-mode ranges at the intended gain. Input bias-current errors, source-imbalance effects, resistor tolerance, and printed-circuit-board leakage should be included in the error budget for precision measurements. This page combines manufacturer specifications, package and pin information, drop-in replacement guidance, comparative parameters, and application-focused engineering guidance to support component selection, PCB implementation, and precision signal-chain design.

見積もり お問い合わせ
INA129A - Precision Instrumentation Amplifier | Texas Instruments
INA129A

INA129A - Precision Instrumentation Amplifier | Texas Instruments

The Texas Instruments INA129A is a precision, low-power instrumentation amplifier packaged in an 8-pin SOIC. It offers excellent accuracy for general-purpose signal conditioning, with low offset voltage, low drift, low input bias current, high common-mode rejection, and input protection to ±40 V. Its versatile three-op-amp architecture supports externally set gains and current-feedback input circuitry that maintains wide bandwidth even at high gain, including 200 kHz at a gain of 100. An instrumentation amplifier is a specialized amplifier that amplifies the difference between two input signals while rejecting common-mode voltage and providing high input impedance. The INA129A belongs to the broader precision analog signal-conditioning hierarchy: instrumentation amplifier, differential amplifier, analog amplifier, and semiconductor. It is used where sensors, transducers, strain gauges, bridge circuits, and measurement front ends require accurate differential amplification with minimal disturbance to the source. The INA129 family is designed for low-power precision applications. A single external resistor sets the gain from 1 to 10,000, according to the manufacturer product information. The device provides a wide supply range of ±18 V, a minimum common-mode rejection of 120 dB, input bias current of 5 nA maximum, and input protection to ±40 V. Its current-feedback input stage is particularly useful in higher-gain designs because it preserves bandwidth better than a conventional voltage-feedback input arrangement. The INA129A can amplify low-level sensor signals in industrial measurement systems, bridge-based load cells, biomedical instrumentation, audio equipment, and data-acquisition systems. Its common-mode rejection helps suppress equal voltages appearing on both inputs, while high input impedance limits loading of the measured source. The ±40 V input protection provides additional robustness when connected to external wiring or larger transients, subject to the complete datasheet ratings and system design limits. When using INA129A, place the gain-setting resistor close to the appropriate gain pins and keep input and feedback traces short to reduce parasitic capacitance and noise pickup. Check supply decoupling, input common-mode range, output swing, and resistor tolerance before finalizing a design. Because the INA129A is a precision analog amplifier, grounding, shielding, clean references, and careful PCB layout can matter as much as nominal gain accuracy. This product page combines the verified INA129A electrical and physical details, manufacturer and distributor references, comparison parameters, and practical design guidance. The listed alternatives are limited to candidates supported by the supplied cross-reference data; package and pin compatibility should still be confirmed against the current manufacturer datasheet before substitution.

見積もり お問い合わせ
INA129P - Precision Low-Power 8-Pin Instrumentation Amp | TI
INA129P

INA129P - Precision Low-Power 8-Pin Instrumentation Amp | TI

The Texas Instruments INA129P is a precision, low-power instrumentation amplifier with one amplifier circuit, 120 dB minimum common-mode rejection, 50 uV maximum offset voltage, and a 200 kHz bandwidth at gain 100, packaged in an 8-pin PDIP. It accepts signals within the low-noise, low-offset instrumentation-amplifier class and supports wide bipolar supply operation up to ±18 V. An instrumentation amplifier is a specialized analog amplifier that measures a small differential voltage while rejecting common-mode interference. Its internal three-op-amp architecture supports high input impedance and adjustable gain, making it useful when a sensor produces a low-level signal and the surrounding wiring introduces substantial common-mode voltage. The INA129P is therefore positioned between a general-purpose operational amplifier and a more specialized precision measurement amplifier. Key features include 50 uV maximum offset voltage, 0.5 uV/°C maximum offset drift, 5 nA maximum input bias current, and input protection to ±40 V. The single external gain-setting resistor provides gain adjustment from 1 through 10,000 according to the manufacturer family information, while current-feedback input circuitry maintains useful bandwidth at higher gain. The stated 200 kHz bandwidth at gain 100 makes the device suitable for sensor and instrumentation signal paths rather than only static measurement. The INA129P uses a low-power instrumentation-amplifier architecture intended for precision measurement systems. Its common-mode rejection helps suppress voltage common to both inputs, and the low offset and drift reduce measurement error in bridge, current, and industrial sensor applications. The ±18 V supply capability provides flexibility for dual-supply analog systems, while the 8-pin PDIP format supports through-hole assembly and prototyping. Typical uses include bridge and load-cell signal conditioning, industrial process measurement, biomedical instrumentation, current sensing, and precision test equipment. The ±40 V input protection specification is useful when the amplifier is positioned near sensor wiring, although system-level protection and operating conditions still require engineering review. The principal design consideration is ensuring that the external gain resistor, supply bypassing, input protection, and common-mode range are matched to the sensor. For a new design, verify the exact INA129P pinout and electrical limits against the current Texas Instruments datasheet before layout release. This page consolidates verified distributor snippets, manufacturer family information, package details, and application guidance, while distinguishing documented specifications from information that requires design-team verification.

見積もり お問い合わせ
INA129PA - Precision Low-Power Instrumentation Amplifier | TI
INA129PA

INA129PA - Precision Low-Power Instrumentation Amplifier | TI

The Texas Instruments INA129PA is a precision, low-power instrumentation amplifier in an 8-pin plastic DIP package, with a maximum input offset voltage of 50 uV, maximum offset drift of 0.5 uV/degC, maximum input bias current of 5 nA, and minimum common-mode rejection of 120 dB. Its input stage tolerates voltages from -40 V to +40 V, while its supply range extends to plus or minus 18 V. These characteristics make it appropriate for precision signal conditioning where low offset, low drift, high common-mode rejection, and input protection are important. An instrumentation amplifier is a differential analog IC used to amplify the voltage difference between two inputs while rejecting signals common to both inputs. The INA129 belongs to the broader instrumentation-amplifier, amplifier-IC, and analog-semiconductor hierarchy. Its internal gain-setting arrangement supports precise amplification of small differential signals in sensor interfaces, industrial measurement systems, and laboratory equipment. The verified device features distinguish the INA129 from ordinary general-purpose operational amplifiers. A 50 uV maximum input offset voltage reduces the effect of input-referred mismatch, while the 0.5 uV/degC maximum drift limits offset variation with temperature. Maximum input bias current of 5 nA is especially relevant when the source impedance is high. Minimum CMRR of 120 dB suppresses common-mode interference, and the -40 V to +40 V input protection range helps the interface tolerate larger external voltages than the internal operating range. The INA129 supports a wide supply range of plus or minus 18 V. A wide operating range allows the amplifier to process signals within systems using higher-voltage rails while retaining the low-power characteristics highlighted for this device. Exact gain, bandwidth, quiescent-current, input-voltage, and output-voltage limits were not available in the supplied verified data and should be taken from the manufacturer datasheet before final design release. Typical uses include bridge-sensor interfaces, current-shunt measurement, precision data acquisition, industrial process monitoring, and low-level differential signal conditioning. For bridge or shunt circuits, the 120 dB minimum CMRR helps reject common-mode noise, while low offset voltage and drift reduce measurement error. The protected inputs may improve robustness when transients or nearby switching nodes can appear at the input terminals. Designers should verify the gain equation, external resistor value, permissible input and output swing, and supply-current limits against the current manufacturer datasheet. Input filtering, source-impedance balancing, grounding, and placement near the measured signal are also important because excessive imbalance can degrade CMRR and the low-offset performance expected from this precision device. This page combines verified manufacturer and distributor information with practical selection guidance, application analysis, pricing context, and verified drop-in alternatives. It distinguishes documented INA129PA characteristics from information that remains unavailable, helping engineers make a more reliable instrumentation-amplifier choice without inventing specifications.

見積もり お問い合わせ
INA129PG4 Precision Instrumentation Amplifier | Texas Instruments
INA129PG4

INA129PG4 Precision Instrumentation Amplifier | Texas Instruments

The Texas Instruments INA129PG4 is a precision, low-power instrumentation amplifier rated for a 700 µA supply current, 1.3 MHz gain-bandwidth product, and 8-PDIP package. It provides a 120 dB minimum common-mode rejection ratio, a 50 µV maximum offset voltage, and a 5 nA maximum input bias current for accurate differential-signal conditioning. An instrumentation amplifier is a specialized amplifier category designed to amplify the difference between two input signals while rejecting common-mode voltage. The instrumentation-amplifier hierarchy includes differential amplifiers, analog signal-conditioning ICs, amplifiers, and semiconductor devices. Its three-op-amp architecture and current-feedback input stage make it suitable for sensors and measurement systems in which small differential signals are superimposed on a larger common-mode voltage. Key characteristics include 4 V/µs slew rate, low offset drift of 0.5 µV/5°C maximum, and input protection to +40 V. The wide supply range extends to +18 V, while the input architecture retains a bandwidth of 200 kHz at a gain of 100. These characteristics support precision bridge, current-shunt, and sensor-amplification circuits without requiring a high-power amplifier. The INA129PG4 uses a versatile three-op-amp architecture. A single external resistor establishes the gain, allowing the same device to serve multiple measurement ranges. Its current-feedback input circuitry is designed to preserve usable bandwidth at higher closed-loop gains. The combination of low supply current, low offset, high CMRR, and protected inputs makes it especially useful for compact, low-power measurement instruments. Typical applications include bridge-sensor signal conditioning, portable instrumentation, industrial process monitoring, medical measurement interfaces, and low-level differential-signal acquisition. Its protected inputs can simplify front-end design when the source may produce transient overvoltage, although the complete application must still satisfy the device's absolute maximum ratings. For a new PCB, use the manufacturer pin-description table to assign all eight DIP connections and place the gain resistor close to the gain-setting pin. Check supply voltage, common-mode input range, input impedance, and output swing at the intended gain before finalizing component values. This product page combines the manufacturer specifications, package details, replacement analysis, parameter comparisons, and practical design guidance to help engineers evaluate the INA129PG4 before committing a precision measurement circuit to production.

見積もり お問い合わせ
INA129U - ±18V Precision Instrumentation Amp | Texas Instruments
INA129U

INA129U - ±18V Precision Instrumentation Amp | Texas Instruments

The Texas Instruments INA129U is a precision, low-power instrumentation amplifier with a 1.3 MHz gain-bandwidth product, 120 dB minimum common-mode rejection, and an 8-pin SOIC package. It accepts single or dual supplies up to ±18 V and uses one external resistor to set gain from 1 through 10,000. Designed around a versatile three-op-amp architecture, the INA129U supports accurate differential measurement while preserving wide common-mode range and robust input protection. An instrumentation amplifier is a specialized amplifier category that measures the voltage difference between two inputs while rejecting signals common to both nodes. INA129U belongs to the hierarchy instrumentation amplifier, differential amplifier, analog signal-conditioning IC, and power-management-independent semiconductor. Its three-op-amp topology provides high input impedance, precise differential gain, and improved common-mode rejection compared with a simple difference amplifier. Key verified features include maximum offset voltage of 50 µV, maximum offset drift of 0.5 µV/°C, maximum input bias current of 5 nA, and differential input protection extending to ±40 V. The current-feedback input circuitry maintains useful bandwidth at higher closed-loop gains, including 200 kHz at a gain of 100. These characteristics make the device useful where small transducer outputs must be amplified accurately in the presence of a larger common-mode voltage. The INA129 gain equation uses a 49.4 kΩ external resistor to support drop-in replacement with comparable instrumentation amplifiers. Gain accuracy depends on that resistor and associated layout parasitics, so designers should follow the manufacturer gain-setting guidance and preserve a symmetric input path. Low bias current is especially valuable for high-impedance sensor sources, while high CMR suppresses supply and ground disturbances that appear equally on both inputs. Typical uses include bridge-transducer signal conditioning, isolated low-voltage sensing, current-shunt measurement, biomedical acquisition, industrial sensor interfaces, laboratory instrumentation, and portable diagnostic equipment. For these applications, the ±40 V protected inputs can reduce accidental overload risk, although external protection and supply limits still require validation. The principal design consideration is keeping both input paths symmetric and placing the gain resistor close to the device. Incorrect Kelvin routing or unequal input impedance can degrade CMR and offset performance. The 8-pin SOIC also makes PCB assembly straightforward, while exposed thermal behavior and supply noise still require normal analog-layout practices. This page consolidates verified manufacturer and distributor information, package details, purchasing context, applications, and replacement guidance. It also distinguishes explicitly supported drop-in candidates from parts that require engineering review, helping designers compare the INA129U with alternatives rather than treating them as automatic equivalents.

見積もり お問い合わせ
INA129U/2K5 - Precision Low Power INA, SOIC-8 | Texas Instruments
INA129U/2K5

INA129U/2K5 - Precision Low Power INA, SOIC-8 | Texas Instruments

The Texas Instruments INA129U/2K5 is a precision, low-power instrumentation amplifier (INA) in an 8-pin SOIC surface-mount package, supplied on a 2,500-piece tape-and-reel. The INA129 family uses a classic three-op-amp topology with current-feedback input stages, delivering 50 µV maximum offset voltage, 0.5 µV/°C maximum drift, 5 nA maximum input bias current, and a minimum common-mode rejection ratio (CMRR) of 120 dB at G = 100. A single external resistor sets any gain from 1 V/V to 10,000 V/V. The /2K5 suffix indicates the SO-8 packaging option on a 2.5k reel per TI's ordering nomenclature. An instrumentation amplifier is a precision differential amplifier with very high input impedance on both inputs, a defined and stable gain set by one external resistor, and exceptionally high common-mode rejection. The INA belongs to the family of analog front-end ICs that sit between a sensor (bridge, thermocouple, biopotential electrode) and an ADC. The category hierarchy is: instrumentation amplifier -> differential amplifier -> operational amplifier -> analog IC -> semiconductor. The three-op-amp topology isolates the input signal from the gain-setting resistor network, allowing tiny differential signals (often microvolts) to be amplified cleanly in noisy industrial environments. Key features of the INA129U/2K5 include wideband operation up to 1.3 MHz (G = 1) with 200 kHz bandwidth even at G = 100, a 4 V/µs slew rate, ±2.25 V to ±18 V dual-supply operation (±2.25 V minimum; typically ±15 V in transducer systems), input protection to ±40 V, and a quiescent current of only 700 µA typical. The exposed SO-8 package simplifies reflow assembly on standard 8-pin SOIC land patterns identical to the INA128, AD620, and other pin-compatible INAs. The current-feedback input stage keeps bandwidth flat across the full gain range, an advantage over voltage-feedback INAs that lose bandwidth at high gain. The INA129's gain equation G = 1 + 49.4kΩ/RG matches the AD620, allowing direct drop-in migration from legacy designs. The combination of low noise, low drift, and high CMRR makes the INA129U/2K5 well-suited for strain-gauge bridges, weigh scales, thermocouple amplifiers, medical instrumentation (ECG/EEG front-ends), and industrial process-control analog inputs. Typical applications include weigh scales and load-cell signal conditioning, ECG and biomedical front-ends, thermocouple and RTD pre-amplification, and industrial 4-20 mA loop readouts. Place the gain-setting resistor close to pins 1 and 8, and use 0.1 µF ceramic bypass capacitors on both supply pins to preserve the 120 dB CMRR across frequency. This page synthesizes distributor pricing, drop-in alternatives, and practical design notes not found in the manufacturer datasheet.

見積もり お問い合わせ
INA129UA - Precision Instrumentation Amplifier | Texas Instruments
INA129UA

INA129UA - Precision Instrumentation Amplifier | Texas Instruments

The Texas Instruments INA129UA is a precision, low-power instrumentation amplifier with one amplifier circuit, 50 µV maximum input offset voltage, and an 8-pin SOIC package. It operates from single or dual supplies up to ±18 V, accepts protected input voltages up to ±40 V, and provides a minimum common-mode rejection ratio of 120 dB. An instrumentation amplifier is a differential amplifier optimized for measuring small signals embedded on larger common-mode voltages. Its signal-path hierarchy is instrumentation amplifier → differential amplifier → analog amplifier → semiconductor. Compared with a conventional difference amplifier, an instrumentation amplifier provides controlled input impedance and accurate differential gain while rejecting common-mode interference from sensors, industrial wiring, and power systems. Key features include maximum input offset drift of 0.5 µV/°C, maximum input bias current of 5 nA, and input-noise performance of 8 nV/√Hz. A single external resistor programs the closed-loop gain, while the three-op-amp architecture maintains common-mode rejection over a useful signal range. Current-feedback input circuitry supports wide bandwidth even at high gain, including 200 kHz at a gain of 100. The INA129UA combines precision offset and drift characteristics with low quiescent-current operation. Its current-feedback inputs are suited to sensing systems in which source impedance, sensor output level, and system noise must be balanced carefully. The ±40 V input protection rating adds robustness in industrial environments, although protected inputs do not remove the need for appropriate fault-current limiting and supply design. Typical uses include bridge-amplifier front ends, strain-gauge and pressure-transducer measurement, low-current sensing, medical instrumentation, industrial process control, and battery-powered sensor interfaces. The 8-pin SOIC package supports compact analog modules and standard surface-mount assembly, while the adjustable gain makes one device usable across several signal ranges when the external resistor and sensor-network requirements are properly matched. For a new design, check input and output common-mode limits, bandwidth at the selected gain, resistor tolerance, and the sensor source impedance before finalizing the layout. Place the gain-setting resistor close to the RG pin, keep input traces short and symmetric, and use a stable reference implementation when the measurement requires nonzero output offset correction. This product page combines the manufacturer’s device information, pin-level guidance, application analysis, and verified drop-in alternatives to support faster component selection and board-level engineering decisions.

見積もり お問い合わせ
INA131AP - Precision G=100 Instrumentation Amp | Texas Instruments
INA131AP

INA131AP - Precision G=100 Instrumentation Amp | Texas Instruments

Texas Instruments INA131AP is a precision, fixed-gain instrumentation amplifier with a gain of 100, a 70 kHz bandwidth, a 106 dB common-mode rejection ratio, and a 125 µV maximum input offset voltage. The device is supplied in an 8-pin PDIP package and operates from ±2.25 V to ±18 V. Its 3-op-amp architecture supports accurate differential signal conditioning, including low-level sensor measurements where common-mode interference must be rejected. An instrumentation amplifier is a specialized analog amplifier optimized for amplifying the difference between two input signals while rejecting voltage common to both inputs. Within the signal-conditioning hierarchy, an instrumentation amplifier is a precision analog IC used for current sensing, bridge excitation, biomedical instrumentation, and industrial measurement. Its internal differential input and feedback arrangement generally provides better common-mode rejection and offset behavior than a conventional op-amp circuit configured for the same function. The INA131AP provides a fixed gain of 100, allowing small differential sensor outputs to be raised to a level suitable for an ADC without an external gain-setting network. Maximum input offset voltage is 125 µV, while input bias current is specified at no more than 2 nA. Input overvoltage protection extends to ±40 V, helping the amplifier tolerate transient voltage at sensor inputs. The listed operating range of ±2.25 V to ±18 V supports dual-supply operation across common industrial and instrumentation systems. Internally, the INA131 uses a three-op-amp instrumentation-amplifier architecture. This arrangement provides high input impedance, differential gain of 100, and strong rejection of common-mode signals. The listed 106 dB CMRR is particularly useful when the measured differential signal is much smaller than the voltage shared by both input terminals. A slew rate of 0.7 V/µs and bandwidth of 70 kHz define its response for low-frequency industrial, measurement, and control signals. Typical uses include precision current sensing, bridge-based pressure and strain measurement, low-level differential sensor interfaces, analog signal conditioning, and buffered measurement channels. The fixed gain also simplifies system calibration because engineers do not need to select or adjust an external precision gain resistor. The 8-pin PDIP package is particularly useful for prototypes, laboratory equipment, legacy industrial systems, and designs assembled through through-hole manufacturing processes. Designers should preserve the input common-mode range and supply headroom for the selected output voltage. Because the gain is fixed at 100, input signals must remain small enough to prevent saturation, while source impedance and sensor grounding can influence offset and bias-current error. The INA131AP is non-isolated and operates from a bipolar supply, so system power architecture, grounding, transient protection, and input filtering should be reviewed before deployment. This product page consolidates the verified distributor data, manufacturer resources, package information, procurement details, and engineering guidance for the INA131AP. It also distinguishes verified drop-in candidates from cross-reference search results, helping engineers evaluate PCB compatibility and device-level limitations rather than relying only on the “instrumentation amplifier” device category.

見積もり お問い合わせ
INA131BP - G=100 Instrumentation Amplifier | Texas Instruments
INA131BP

INA131BP - G=100 Instrumentation Amplifier | Texas Instruments

The Texas Instruments INA131BP is a precision instrumentation amplifier with a fixed gain of 100, a 2.25 V to 18 V supply range, and an 8-pin PDIP package. It uses a three-amplifier architecture and combines laser-trimmed internal circuitry with a bandwidth of 70 kHz and a slew rate of 0.7 V/µs. These characteristics make it suitable for conditioning low-level differential sensor signals before measurement, conversion, or control. An instrumentation amplifier is a specialized amplifier that amplifies the voltage difference between two inputs while rejecting common-mode interference. Its internal topology belongs to the amplifier hierarchy: instrumentation amplifier, operational amplifier, analog signal-conditioning IC, and semiconductor. Unlike a conventional differential amplifier, this device is intended to provide accurate differential gain with minimal dependence on external resistor matching. The INA131BP provides a fixed gain of 100, simplifying circuit design because no external gain-setting network is required for normal operation. Its 70 kHz bandwidth supports signals from slow sensor measurements through moderate-bandwidth industrial and instrumentation signals. The 2.25 V to 18 V operating supply supports single-supply and dual-supply arrangements, while the listed maximum total supply voltage of 50 V provides additional headroom for suitable protection and biasing conditions. The three-op-amp design is a key technical feature because it performs differential input amplification, common-mode rejection, and level shifting in one integrated circuit. The laser-trimmed construction is intended to improve gain accuracy and reduce the need for calibration. Its 0.7 V/µs slew rate helps the output track input steps without excessive distortion, although bandwidth and slew-rate requirements should both be checked against the intended signal bandwidth. Typical uses include bridge-transducer signal conditioning, current-shunt measurement, industrial sensor interfaces, laboratory instrumentation, and analog-to-digital converter front ends. The fixed gain is particularly useful when a transducer already includes scaling and the system requires consistent amplification before sampling. The device can also participate in low-side current measurement when the shunt voltage remains within the amplifier's input and common-mode limits. Designers should verify the input common-mode range, output swing, offset voltage, bias current, noise, and supply-current limits in the INA131 datasheet before finalizing a board. Decoupling capacitors should be placed directly beside the supply pins, and the input and reference connections should be routed away from noisy switching nodes. Because the INA131BP uses a through-hole PDIP package, it is also convenient for prototypes, educational systems, and test equipment where socketed construction or hand assembly is useful. This page consolidates the confirmed electrical characteristics, package information, practical application guidance, and verified drop-in alternatives for the INA131BP. It is designed to help engineers compare the fixed-gain amplifier with other instrumentation-amplifier options while keeping PCB compatibility, supply range, gain, and bandwidth requirements in view.

見積もり お問い合わせ
INA132U - Low-Power Unity-Gain Diff Amp | TI | 8-SOIC
INA132U

INA132U - Low-Power Unity-Gain Diff Amp | TI | 8-SOIC

The Texas Instruments INA132U is a low-power, unity-gain difference amplifier consisting of a precision op amp with an on-chip precision resistor network, housed in an 8-pin SOIC package. It operates from a single supply of 2.7V to 36V (or dual ±1.35V to ±18V), draws only 75 µA quiescent current, and offers 300 kHz small-signal bandwidth with a 1 MHz unity-gain op-amp stage. A difference amplifier is an op-amp-based circuit that amplifies the voltage difference between two inputs while rejecting signals common to both (the common-mode voltage). It is a foundational building block in signal-chain electronics, classified under instrumentation amplifiers and differential interfaces. Within the broader taxonomy, the INA132U sits at: difference amplifier -> instrumentation amplifier -> operational amplifier -> amplifier IC -> analog semiconductor. On-chip laser-trimmed resistors set the gain at exactly unity (G = 1), so no external precision network is required, simplifying PCB layout and BOM cost in measurement and sensor-conditioning applications. Key features include 250 µV typical offset voltage, a 60 V/µs equivalent slew rate at the op-amp core, and a quiescent current of 160 µA maximum over temperature. The internal op-amp common-mode range extends to the negative supply rail, enabling true single-supply operation from ground-referenced or low-side-shifted signals. Excellent TCR (temperature coefficient of resistance) tracking of the thin-film resistors maintains both gain accuracy and common-mode rejection across the -40°C to +85°C industrial range. The architecture uses a precision bipolar input stage followed by a fixed-gain thin-film resistor network and a unity-gain output buffer. CMRR exceeds 80 dB at DC for matched input impedances, and the integrated resistor matching eliminates the gain error and trimming burden typically associated with discrete difference amplifiers built from precision 0.1% resistors and a four-op-amp instrumentation topology. Typical applications include bridge transducer signal conditioning (load cells, strain gauges), ground-loop elimination in long-cable runs, differential signal reception in industrial process control, ECG/biopotential front-ends, and audio balanced-line receivers. Designers also use the INA132U as a building block inside higher-order active filters and as a differential-to-single-ended converter for ADC inputs. When designing with this part, observe the absolute maximum supply of 36V (single) or ±18V (dual) and ensure input common-mode voltage stays within the input range of each input pin, not just the differential value. A 0.1 µF supply decoupling capacitor placed within 5 mm of the V+ pin is recommended. The integrated gain is fixed at 1, so external attenuation or pre-gain stages are needed when the source signal is smaller than the ADC full scale. This page synthesizes distributor pricing, drop-in pin-compatible alternatives, and practical design notes not found in the manufacturer datasheet.

見積もり お問い合わせ
INA132UA - Low-Power Difference Amplifier | Texas Instruments
INA132UA

INA132UA - Low-Power Difference Amplifier | Texas Instruments

The Texas Instruments INA132UA is a low-power, unity-gain difference amplifier with a 500 uV input-referred offset, 300 kHz gain-bandwidth product, and low 160 uA quiescent current. Designed for precision differential measurement, the device combines a precision operational amplifier with a laser-trimmed internal resistor network. It is offered in an 8-pin SOIC package and supports single-supply operation up to 36 V or dual-supply operation up to ±18 V. A difference amplifier is a specialized operational-amplifier circuit that measures the voltage difference between two input nodes while rejecting voltage common to both inputs. Within the amplifier-IC hierarchy, the INA132UA belongs to the precision instrumentation-amplifier family, combining an operational amplifier, precision gain-setting resistors, and high common-mode rejection in one package. This integration reduces external component count while preserving accurate gain behavior across temperature. The principal features of the INA132UA include 90 dB common-mode rejection, ±0.075% maximum gain error, and 0.001% maximum nonlinearity. Its internal resistors are laser trimmed for accurate gain, and their temperature-coefficient tracking helps preserve gain accuracy and common-mode rejection over operating temperature. The low-power architecture operates from a single supply as high as 36 V, making it suitable for both compact battery-powered systems and higher-voltage industrial instrumentation. The INA132UA uses a unity-gain architecture, so the differential output is scaled 1:1 from the difference between its inputs. The internal precision resistor network establishes the gain relationship without an external gain-setting resistor. Its common-mode rejection is particularly important when a small sensor signal is superimposed on a larger reference or supply-derived voltage, because the amplifier attenuates the common component while retaining the differential measurement. Typical applications include bridge-sensor and transducer signal conditioning, current-shunt measurement, battery and power-system monitoring, industrial process-control instrumentation, and precision analog sensing. The device is also appropriate for low-side current sensing when the input common-mode voltage remains within the operating range. Its 8-pin SOIC footprint supports conventional surface-mount assembly. Designers should preserve the input common-mode and output-voltage limits, provide stable input and output bypassing, and verify that source impedances remain compatible with the amplifier's input and common-mode performance. The low quiescent current reduces supply demand, but input bias current and common-mode behavior still determine accuracy in high-impedance sensor circuits. The manufacturer pin-description table should be used when assigning PCB tracks and confirming polarity. This product record combines the device's manufacturer-defined characteristics with same-package replacement guidance, application-specific engineering context, and practical layout considerations. It is intended to help engineers identify whether the unity-gain INA132UA fits a differential-measurement design without confusing it with wider-gain or different-supply-range amplifier families.

見積もり お問い合わせ
INA133U - 1.5MHz Precision Difference Amplifier | TI
INA133U

INA133U - 1.5MHz Precision Difference Amplifier | TI

The Texas Instruments INA133U is a 1.5 MHz, precision unity-gain difference amplifier with up to 450 µV offset, 0.95 mA typical power-supply current, and an 8-pin SOIC package. Designed for low-level differential measurement, it combines a precision operational amplifier with a laser-trimmed resistor network for accurate gain and common-mode rejection. The device is offered in the INA133U package configuration identified by DigiKey as an 8-SOIC differential amplifier. A difference amplifier is a specialized analog amplifier that amplifies the voltage difference between two inputs while rejecting signals common to both inputs. This function is useful when a sensor, transducer, or measurement node is exposed to large common-mode voltages and the desired information exists only as a small differential signal. In the broader hierarchy, the INA133U belongs to instrumentation and difference amplifiers, within operational amplifiers and analog signal-conditioning ICs. The INA133U combines 1.5 MHz bandwidth with low offset voltage and low power consumption. Its high-speed behavior makes it suitable for current-shunt monitoring, bridge excitation, differential sensing, and industrial signal-conditioning systems. The on-chip laser-trimmed resistors are designed to improve gain accuracy and common-mode rejection, while their temperature-coefficient tracking helps preserve performance across temperature changes. The precision architecture is important because it combines amplifier bandwidth with accurate differential gain. A difference amplifier can reject shared interference, but its usefulness still depends on common-mode voltage staying within the device operating limits and on the surrounding circuit presenting suitable impedance and filtering. Designers should verify the complete input, output, supply, and common-mode conditions from the manufacturer datasheet. Typical applications include high-side current measurement, differential voltage sensing, bridge-based sensor interfaces, amplifier-input protection networks, and industrial control systems. In a shunt monitor, the INA133U can amplify the voltage across a low-ohm resistor while reducing the effect of supply or ground disturbances. In bridge sensing, it helps convert a small differential sensor output while rejecting common-mode excitation voltage. The principal design trade-off is bandwidth versus precision and power. The 1.5 MHz bandwidth supports faster signal changes than a purely low-bandwidth precision amplifier, while the 0.95 mA power figure favors low-power systems. PCB layout should keep input traces short, use a solid ground reference, and provide stable supply bypassing. This page synthesizes the verified manufacturer and distributor information, practical design considerations, and carefully limited replacement guidance.

見積もり お問い合わせ
INA133UA - 1.5 MHz Precision Difference Amplifier | Texas Instruments
INA133UA

INA133UA - 1.5 MHz Precision Difference Amplifier | Texas Instruments

Texas Instruments INA133UA is a precision difference amplifier with 1.5 MHz bandwidth, 450 uV maximum offset voltage, and 0.95 mA power consumption. The device is packaged in an 8-pin SOIC surface-mount package and is designed for high-speed signal-chain applications where a differential input must be amplified accurately. According to the Texas Instruments INA133 product information, the INA133 family uses a unity-gain configuration and provides high gain accuracy and common-mode rejection ratio. The verified product listing identifies the INA133UA as a differential amplifier in an 8-SOIC package, while the INA133UA/2K5 ordering variant is also listed in an 8-pin SOIC package. A difference amplifier is an operational-amplifier-based circuit that responds to the voltage difference between two input terminals rather than to either input voltage independently. This makes the INA133UA suitable for current-sense, bridge-sensor, instrumentation, and high-speed measurement circuits where common-mode voltage can be substantially larger than the wanted differential signal. The 1.5 MHz bandwidth provides a useful compromise between response speed and precision, while the specified 450 uV offset and 0.05% maximum gain error help establish the accuracy of the amplified result. The INA133UA operates with single or dual power supplies according to the manufacturer family information. Its 0.95 mA power consumption is suitable for compact, low-power signal-conditioning equipment when compared with general-purpose implementations that consume more current. The 8-pin SOIC package permits conventional surface-mount assembly and provides a straightforward footprint for designs that require one precision differential amplifier. Typical uses include bridge-based pressure and load sensing, current measurement in power-conversion systems, industrial instrumentation, and high-speed analog signal conditioning. In each case, the input common-mode range, supply voltage, output swing, gain-setting method, and required common-mode rejection must be checked against the complete manufacturer datasheet before implementation. Designers should pay particular attention to input filtering, resistor matching, supply bypassing, and the output reference connection. The INA133UA is not automatically interchangeable with every 8-pin amplifier because package compatibility alone does not guarantee electrical compatibility. Verify the exact pinout, supply ratings, common-mode limits, gain configuration, and stability requirements before releasing a PCB. This product page combines the verified Texas Instruments product description, distributor package information, price reference, and cross-reference results with practical selection guidance for engineers evaluating a drop-in replacement.

見積もり お問い合わせ