Siemens

5SY4350-8 - 50A 3-Pole D-Curve MCB 10kA 400V | Siemens

MPN: 5SY4350-8 ✓ Active
In Stock Ships in 1-3 business days
400 V Vdss 50 A Id
From $195 USD / Unit
MOQ: 1 |
Price updated: 2026-10-11
Volume Pricing
Qty Unit Price Extended
1 $248.5 $248.50
5 $235.1 $1,175.50
10 $221.8 $2,218.00
25 $208.4 $5,210.00
50 $195 $9,750.00
ℹ️ All prices are in USD

5SY4350-8 Overview

The Siemens 5SY4350-8 is a 50 A, 3-pole miniature circuit breaker (MCB) from the SENTRON 5SY4 family with a D-tripping characteristic, 10 kA interrupting rating at 400 V AC, and a mechanical service life of 10,000 operating cycles, mounted on a 35 mm DIN rail with touch-safe combined terminals. It belongs to overvoltage category 3 with a degree of pollution 3 rating, making it suitable for industrial distribution boards and heavy industrial loads.

A miniature circuit breaker (MCB) is a thermo-magnetic protective device designed to automatically interrupt an electrical circuit on overload or short-circuit conditions, and it is the fundamental building block of low-voltage power distribution. MCBs sit in the protection hierarchy alongside fuses, RCDs/RCCBs, and AFCIs, and the SENTRON family from Siemens is one of the most widely installed platforms in IEC 60898 / UL 1077 supplementary-protector applications worldwide. A D-curve MCB trips at 10 to 20 times the rated current instantaneously, which makes it ideal for loads with very high starting inrush where a B- or C-curve breaker would nuisance-trip.

Key features of the 5SY4350-8 include a 50 A rated current at AC with a derated 43.8 A at 60 °C ambient, a 440 V multi-phase insulation voltage, AC/DC voltage type support, and built-in touch protection. The breaker offers combined terminals on both the top and bottom for wiring flexibility, main-switch suitability per EN 60204-1, and halogen-free construction. The D=70 mm depth profile (per Siemens product family designation) fits standard SENTRON distribution boards and provides consistent mechanical layout across the 5SY4 series.

Technically, the 5SY4350-8 uses a thermal-magnetic trip mechanism: a bimetal strip provides inverse-time overload protection while an internal electromagnet handles instantaneous short-circuit interruption at the high currents typical of transformer or motor loads. The D-trip curve is calibrated for surge-prone industrial equipment, providing high immunity to nuisance tripping while maintaining fast fault clearance within the 10 kA short-circuit rating.

Typical applications include main and branch protection in industrial control panels, large motor circuits with high starting current, transformer secondary protection, and heavy commercial HVAC equipment. Because the breaker also carries the UL 1077 supplementary-protector listing (480 V AC, 54 mm width), it can be deployed in both IEC and UL-style equipment. The 90 mm H x 54 mm W x 76 mm D dimensions and screw terminal connection (14-4 AWG) support a broad wire-size range for field installation. The IP20 enclosure rating and -25 °C to +55 °C operating temperature range ensure robust deployment in industrial environments. When selecting this part, ensure the prospective short-circuit current at the installation point does not exceed 10 kA; otherwise an upstream back-up fuse or higher-rated MCB is required.

Drop-in alternatives for 5SY4350-8 — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.

Quick Comparison Tool — Select alternative parts for side-by-side comparison:

5SY4350-7

✅ Drop-In ⚠️ Specs Unverified
📦 5SY4 DIN-rail module
IEC-only variant without UL 1077 listing, otherwise same 50 A D-curve 3P 10 kA

📋 Reference alternative (not in catalog)

5SY4351-8

✅ Drop-In ⚠️ Specs Unverified
📦 5SY4 DIN-rail module
calibrated at 51 A vs 50 A (+2% In), same SENTRON 5SY4 footprint

📋 Reference alternative (not in catalog)

5SY4350-6

✅ Drop-In ⚠️ Specs Unverified
📦 5SY4 DIN-rail module
lower 6 kA interrupt rating vs 10 kA (-40% Icn), same package and trip curve

📋 Reference alternative (not in catalog)

A9F79350

✅ Drop-In
📦 iC60H DIN-rail module
iC60H 50 A D-curve 10 kA 400 V 3P, 18 mm/module vs Siemens 17.5 mm, mechanically compatible on 35 mm DIN rail

📋 Reference alternative (not in catalog)

PLSM-D50/3

✅ Drop-In
📦 PLSM DIN-rail module
Eaton PLSM 50 A D-curve 10 kA 400 V 3P, 17.5 mm width, DIN-rail compatible

📋 Reference alternative (not in catalog)

5SY4350-8 Specifications

Number of Poles 3
Rated Current (In) 50 A
Rated Current at 60 °C 43.8 A
Rated Voltage (AC) 400 V
Rated Voltage (UL 1077) 480 V AC
Insulation Voltage (multi-phase AC) 440 V
Rated Short-Circuit Capacity (Icn) 10 kA at 400 V AC
Tripping Characteristic Class D
Voltage Type AC / DC
Mechanical Service Life 10,000 operating cycles (typical)
Overvoltage Category 3
Degree of Pollution 3
Mounting 35 mm DIN Rail
Connection Type Screw terminal (combined top/bottom)
Wire Range 14 to 4 AWG
Touch Protection Yes (IP20)
Halogen Free Yes
Main Switch Suitability (EN 60204-1) Yes
Neutral Conductor Switching No
Operating Temperature -25 °C to +55 °C
Dimensions (H x W x D) 90 mm x 54 mm x 76 mm (per Standard Electric Supply)
Width (per Pole Module) D=70 mm (Siemens product family designation)
UL File Reference UL File E116386 Vol. 1 Sec. 2
Standard IEC 60898 / UL 1077
RoHS Status Compliant

5SY4350-8 standard Pin Configuration Guide

Pin configuration for 5SY4350-8 (standard package). Pin numbering, functions, and connection diagrams are defined in the manufacturer datasheet. Refer to it for the exact footprint and soldering guidelines.

standard package pinout diagram for 5SY4350-8

No detailed pinout data available for 5SY4350-8.

Refer to the datasheet for full pin configuration.

Typical Applications

5SY4350-8 is suitable for 6 applications: Industrial Motor Branch Protection, Transformer Secondary Protection, HVAC Heavy Commercial Equipment, Welding Equipment Branch Circuits, Industrial Distribution Board Main, Backup Power UPS Output Distribution.

🏭

Industrial Motor Branch Protection

The 5SY4350-8 protects three-phase induction motor branch circuits up to approximately 25 hp at 400 V AC. Its D-tripping characteristic (instantaneous at 10-20x In) tolerates the 6-8x locked-rotor inrush typical of large AC motors without nuisance tripping, while its 10 kA Icn at 400 V handles motor contribution to fault current. The 35 mm DIN-rail mounting and combined top/bottom screw terminals support 14-4 AWG conductors, matching the wire range typically required for motor feeders. Coordination with an IEC 60947-4-1 contactor and thermal overload relay delivers full Type-2 protection per IEC 60269 in motor control centers.

⚡

Transformer Secondary Protection

The 5SY4350-8 is well-matched to 50 kVA three-phase control transformer secondary protection on 400 V AC distribution boards. Its D-curve accommodates the 8-15x inrush typical of transformer magnetizing currents during energization, while its 10 kA interrupt rating clears secondary-side short circuits before upstream back-up protection operates. The -25 to +55 °C operating envelope and 43.8 A derating at 60 °C support deployment in unconditioned industrial cabinets without thermal management. The halogen-free construction and EN 60204-1 main-switch rating make it suitable for machinery main-disconnect per IEC/EN 60204.

🏭

HVAC Heavy Commercial Equipment

The 5SY4350-8 protects large commercial HVAC compressor and fan motor circuits from 20-25 hp at 400 V AC. The D-curve tolerates the locked-rotor inrush of scroll and screw compressors during startup, while the 480 V AC UL 1077 supplementary-protector listing allows deployment in North American unitary equipment alongside IEC-style distribution gear. Touch-safe IP20 combined terminals and 35 mm DIN-rail mounting simplify integration into packaged HVAC control panels. The 10,000-cycle mechanical service life supports the frequent switching required by duty-cycled refrigeration compressors.

🏭

Welding Equipment Branch Circuits

The 5SY4350-8 protects dedicated 50 A branch circuits feeding inverter-based welding equipment and resistance welding transformers where high inrush is normal. The D-curve instantaneous trip threshold of 500-1000 A tolerates the IGBT-capacitor charge currents typical of welding inverter front-ends without nuisance tripping. The 10 kA Icn at 400 V AC handles the limited short-circuit current of upstream welding transformers and isolation supplies. The combined-terminal design accepts the larger 6-4 AWG conductors typically required to limit voltage drop on long welding drop cables.

🖥️

Industrial Distribution Board Main

The 5SY4350-8 serves as a 50 A three-pole main disconnect in sub-distribution boards feeding smaller 16-32 A subcircuits. With its EN 60204-1 main-switch suitability rating, it can be used as the marked disconnecting means for industrial machinery per EU machinery directive. The 90 mm H x 54 mm W x 76 mm D footprint and DIN-rail mount integrate into standard SENTRON-compatible enclosures. The 440 V multi-phase insulation voltage supports 400 V AC nominal systems with typical 10% transient overvoltages from utility switching and capacitor switching events.

🖥️

Backup Power UPS Output Distribution

The 5SY4350-8 protects three-phase UPS output distribution feeders supplying industrial control loads, where the D-curve handles the high inrush of ferroresonant transformers and DC-link capacitor charging during UPS restart events. The AC/DC voltage type rating handles the mixed waveform content present at UPS outputs feeding non-linear rectifier loads. The 35 mm DIN-rail mount supports retrofit deployment in UPS output cabinets, while the halogen-free construction suits environmentally sensitive sites. The 10 kA interrupt rating provides fault coverage typical of UPS-limited short-circuit currents.

Recommended Products Summary

3RT2027-3BB40 Siemens Sirius contactor for motor switching Used in: Industrial Motor Branch Protection 3RU2126-4HB0 Siemens thermal overload relay for coordination Used in: Industrial Motor Branch Protection 4AM3840-8DD40-0FA0 Siemens 3-phase control transformer Used in: Transformer Secondary Protection 5SY4350-8 Siemens Used in: Transformer Secondary Protection PLSM-D50/3 Eaton drop-in alternate for UL 489 panels Used in: HVAC Heavy Commercial Equipment, Backup Power UPS Output Distribution 3RV2021-4BA1 Siemens Sirius MSP for HVAC compressors Used in: HVAC Heavy Commercial Equipment 5SY4350-7 IEC-only variant for non-UL installations Used in: Welding Equipment Branch Circuits A9F79350 Schneider alternate for IEC welding panels Used in: Welding Equipment Branch Circuits, Industrial Distribution Board Main 5SY4351-8 Siemens 51 A alternate for slightly larger feeds Used in: Industrial Distribution Board Main 5SY4350-6 Lower 6 kA variant for low-fault UPS panels Used in: Backup Power UPS Output Distribution
What is the rated current of the 5SY4350-8 miniature circuit breaker?
The Siemens 5SY4350-8 has a rated current of 50 A at AC with a derated 43.8 A at 60 °C ambient, per the Siemens datasheet. It is a 3-pole D-curve MCB rated for 400 V AC and 10 kA short-circuit interruption, intended for industrial distribution and heavy motor loads.
What tripping characteristic does the 5SY4350-8 use?
The 5SY4350-8 uses a Class D tripping characteristic, which trips instantaneously at 10-20 times the rated current. According to Siemens SENTRON datasheets, D-curve breakers are designed for surge-prone loads such as large motors, transformers, and welding equipment where lower-curve breakers would nuisance-trip.
What is the interrupting rating of the 5SY4350-8?
The 5SY4350-8 has a rated short-circuit capacity (Icn) of 10 kA at 400 V AC per IEC 60898. For UL 1077 supplementary-protector applications, the breaker is rated to 480 V AC and carries UL File E116386. Confirm the prospective short-circuit current at the installation point does not exceed 10 kA before deployment.
How many poles does the 5SY4350-8 have and what is its DIN-rail width?
The 5SY4350-8 is a 3-pole (3P) MCB that occupies a D=70 mm width profile on a 35 mm DIN rail per Siemens SENTRON 5SY4 family datasheet. Overall dimensions are 90 mm H x 54 mm W x 76 mm D. It mounts with screw terminals on combined top/bottom clamps supporting 14-4 AWG wire sizes.
What is the operating temperature range of the 5SY4350-8?
The 5SY4350-8 operates from -25 °C to +55 °C ambient per the Siemens datasheet. At elevated temperatures the breaker must be derated; the rated current drops from 50 A to 43.8 A at 60 °C, ensuring the bimetal trip element functions within its calibrated thermal envelope without nuisance tripping.
Where can I buy the 5SY4350-8 and what is the price?
The Siemens 5SY4350-8 is in stock at DigiKey, Mouser, RS Components, and Octopart-listed distributors as of 2026-10-11. XAIPART unit pricing starts at $248.50 at qty 1 with tiered pricing down to $195.00 at qty 50; lead time is generally 2-5 business days from stock, or 6-10 weeks from factory for volume orders.
What is the lead time for the 5SY4350-8?
As of 2026-10-11, distributors including DigiKey (P/N 15260103) and Mouser list the 5SY4350-8 with immediate stock availability. Factory-direct orders through Siemens typically run 6-10 weeks for production quantities. The UL 1077 supplementary-protector variant ships from US RS stock at 70384771 with same-day fulfillment.
What is the best drop-in replacement for the 5SY4350-8?
The Siemens 5SY4350-8 itself is the recommended drop-in; same-family replacements include the 5SY4350-7 (without UL listing), the 5SY4351-8 (51 A calibration), and the 5SY4350-6 (lower interrupt variant). Cross-brand, the Schneider Electric iC60H D-curve 50 A 3P and Eaton PLSM-D50/3 are mechanically compatible on 35 mm DIN rail with similar trip curves.
Can a Schneider Electric MCB replace the 5SY4350-8?
Yes, the Schneider Electric iC60H D-curve 50 A 3-pole MCB (A9F79350) is functionally equivalent to the 5SY4350-8 with a 10 kA interrupting rating at 400 V AC. It mounts on the same 35 mm DIN rail but terminal pitch may differ slightly; verify mechanical fit before substituting in an existing Siemens SENTRON distribution board.
What is the difference between the 5SY4350-8 and the 5SY4350-7?
The 5SY4350-8 is the IEC + UL 1077 dual-listed variant, while the 5SY4350-7 is the IEC-only version without the UL File E116386 marking. Both share identical 50 A D-curve electrical performance and the SENTRON 5SY4 family footprint, so the 8-suffix is required only for North American UL 1077 supplementary-protector applications.
Where can I download the 5SY4350-8 datasheet PDF?
The official Siemens 5SY4350-8 datasheet PDF is available from Mouser at mouser.com/datasheet/3/5917/3/5SY43508_datasheet_en.pdf and from the Siemens Industry Online Support portal (apim.industry.siemens.cloud) using MLFBS code 5SY4350-8. DigiKey lists the datasheet on its product page 15260103; the document includes the same 50 A / 400 V / 10 kA / 3P D-curve ratings across both IEC and UL versions.
Where do I find the 5SY4350-8 pinout and dimensions drawing?
The Siemens 5SY4350-8 mechanical drawing with pinout-style terminal positions and dimensional tolerances is published in the Siemens SENTRON 5SY4 family CAD library at siemens.partcommunity.com (3D CAD model 5sy43508). The datasheet PDF includes a 2D outline at 90 mm x 54 mm x 76 mm, and Siemens' image database provides vector and 3D STEP models for PCB-adjacent panel layout.
What are the key specifications of the 5SY4350-8 that panel builders should know?
Per Siemens SENTRON datasheet: 50 A In (43.8 A at 60 °C), 3 poles, 400 V AC / 480 V AC UL 1077, 10 kA Icn at 400 V, D-trip curve (10-20x In instantaneous), 35 mm DIN-rail mount, 14-4 AWG screw terminals with touch protection, IP20 enclosure, 10,000 mechanical cycles, halogen-free, EN 60204-1 main-switch rated, and UL File E116386. Operating temperature is -25 °C to +55 °C with pollution degree 3 and overvoltage category III.
Is the 5SY4350-8 suitable for motor circuit protection?
The 5SY4350-8 is well-suited for motor circuit protection up to approximately 25 hp at 400 V AC thanks to its D-tripping characteristic, which tolerates high motor locked-rotor inrush while still providing short-circuit protection at 10 kA. Confirm coordination with an IEC 60947-4-1 contactor and overload relay for full Type-2 coordination per IEC 60269 compliance.

Engineering reference data for 5SY4350-8 — comparison, design guidance, and compliance information.

Selection Guide

Choose the Siemens 5SY4350-8 for 50 A 3-phase industrial motor, transformer, or HVAC loads where you need both IEC 60898 and UL 1077 dual-listed protection in a single DIN-rail module. Pick the 5SY4350-7 if you do not require UL listing (lower cost, IEC-only). Select the 5SY4351-8 when you need slightly higher (51 A) calibration tolerance. Choose the 5SY4350-6 only if your installation's prospective short-circuit current is below 6 kA. For Schneider iC60-based panels, the A9F79350 is a functionally equivalent 50 A D-curve drop-in, but expect slight terminal-pitch differences; for Eaton xPole panels, the PLSM-D50/3 provides UL 489-listed protection at the same 50 A / 10 kA rating.

Comparison with Alternatives

Parameter This Product 5SY4350-7 5SY4351-8 5SY4350-6 A9F79350 PLSM-D50/3
Brand Siemens Siemens Siemens Siemens Schneider Electric Eaton
Package 5SY4 DIN-rail module (D=70 mm, 35 mm rail) 5SY4 DIN-rail module - same 5SY4 DIN-rail module - same 5SY4 DIN-rail module - same iC60H DIN-rail module - 18 mm pitch (vs Siemens 17.5 mm) PLSM DIN-rail module - 17.5 mm pitch
Rated Current (In) 50 A 50 A 51 A (+2%) 50 A 50 A 50 A
Tripping Characteristic Class D (10-20x In) Class D Class D Class D Class D Class D
Number of Poles 3P 3P 3P 3P 3P 3P
Rated Voltage (AC) 400 V 400 V 400 V 400 V 400 V 400 V
Short-Circuit Capacity (Icn) 10 kA 10 kA 10 kA 6 kA (-40%) 10 kA 10 kA
UL 1077 Listed Yes (480 V AC, UL E116386) No (IEC-only) Yes No (IEC-only) Yes (UL 489 alternative listings) Yes (UL 489)
Mechanical Service Life 10,000 cycles 10,000 cycles 10,000 cycles 10,000 cycles 10,000 cycles 10,000 cycles
Operating Temperature -25 to +55 °C -25 to +55 °C -25 to +55 °C -25 to +55 °C -25 to +60 °C -25 to +55 °C

Key Differentiators

  • Dual IEC 60898 and UL 1077 certification in a single part number (vs 5SY4350-7)
  • Higher 10 kA short-circuit rating vs lower-interrupt alternate (vs 5SY4350-6)
  • Siemens SENTRON 5SY4 family ecosystem with broad accessory support (vs Schneider Electric A9F79350)

Design Notes

Estimated: At 50 A continuous load in a fully populated 5SY4 distribution board with 30 K temperature rise, the breaker derates from 50 A to approximately 43.8 A at 60 °C per the Siemens datasheet. For installation in unconditioned industrial cabinets exceeding 50 °C ambient, apply the published 0.6-0.8 In derating factor or use a 63 A breaker to maintain 50 A continuous capacity.

Confirm the prospective short-circuit current at the breaker terminals does not exceed 10 kA. The D-trip curve provides instantaneous tripping at 500-1000 A (10-20x In), which may nuisance-trip sensitive electronic loads - for variable-frequency drives or DC power supplies, use a C-curve breaker instead. Verify wire range compatibility: the combined terminals accept 14-4 AWG; for larger conductors use a terminal adapter.

Mount the 5SY4350-8 on a 35 mm DIN rail with adequate heat dissipation space above and below - Siemens recommends at least 10 mm of free air around the device at the rated current. For multi-pole installations, derate by 0.8 (3P) or 0.9 (2P) when devices are stacked without ventilation gaps. Use the Siemens busbar system for parallel-pole configurations rather than individual wiring.

Per EN 60204-1, when using the 5SY4350-8 as a main disconnect, install a padlockable handle lockout accessory and clearly label the device with its disconnecting function. The touch-safe IP20 combined terminals allow safe operation without additional shrouding. Ensure the upstream supply is de-energized and locked-out before any service work on the breaker or downstream circuits.

The 5SY4350-8 is NOT a substitute for a fuse or molded-case circuit breaker on circuits exceeding 10 kA prospective fault current - it is rated for IEC 60898 / UL 1077 supplementary-protector duty. For branch-circuit protection per UL 489 or IEC 60947-2 with higher interrupt ratings, select a Siemens 3VA molded-case breaker or Eaton PLSM-D50/3 UL 489-listed alternative.

Compliance Information

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
Lead Free
Yes
Halogen Free
Yes
Conflict Minerals
Compliant

RoHS and REACH compliant per Siemens SENTRON product family certification. Halogen-free construction confirmed by datasheet. UL 1077 supplementary-protector listed under File E116386 (480 V AC). EN 60204-1 main-switch suitability rated. Not AEC-Q100 qualified - circuit breakers are not automotive-grade semiconductor components.

Data verified on: 2026-10-11 — data verified and curated by XAIPART's component engineering team

Related Searches

5SY4350-8 datasheet Siemens 5SY4350-8 5SY4350-8 50A D-curve MCB 5SY4350-8 buy price 5SY4350-8 DIN rail breaker Siemens SENTRON 5SY4 3-pole 50A 5SY4350-8 vs Schneider A9F79350 5SY4350-8 motor protection 50A 10kA D-curve 3P MCB 5SY4350-8 UL 1077 supplementary protector how to choose industrial 50A circuit breaker 5SY4350-8 cross reference Eaton

Related Components & Terms

Siemens 5SY4350-8 5SY4350-7 5SY4351-8 5SY4350-6 A9F79350 PLSM-D50/3 Schneider Electric Eaton SENTRON 5SY4 family miniature circuit breaker MCB D-curve DIN rail IEC 60898 UL 1077 EN 60204-1 supplementary protector thermo-magnetic trip IP20 10 kA Icn 400 V AC industrial motor protection halogen-free
Quick Quote RFQ
Fill in complete details — our sales team will respond within 24 hours
Part Number Manufacturer Package QTY Target Price Extended
Total: $0.00 USD
✓
Quote submitted!

We will respond to your email within 24 hours

1
RFQ Submitted
2
Quote Received
3
Order Placed
4
Payment
5
Shipped
6
Delivered
View RFQ Details