ADM3073EYRZ - 500kbps ESD RS-485 Transceiver | Analog Devices
MPN: ADM3073EYRZ ✗ End of LifeADM3073EYRZ Overview
An RS-485 transceiver is a differential line-interface component used to connect a host controller to a balanced, multidrop communication bus. Its transmit and receive paths support the RS-485 and RS-422 physical layers, placing it in the interface IC hierarchy alongside differential line drivers, receivers, and other communication transceivers. Balanced signaling improves noise immunity in industrial environments where cables may run near motors, relays, and power-conversion equipment.
The ADM3073EYRZ operates from a 3.3 V supply and supports communication rates up to 500 kbps. Its principal protection feature is ±15 kV ESD protection on the bus-facing interface. The full-duplex configuration provides separate transmit and receive paths, which is useful for point-to-point links, industrial control networks, and equipment requiring continuous bidirectional communication. The 14-pin SOIC package supports conventional surface-mount assembly.
The integrated transceiver architecture reduces the component count and board area associated with separate RS-485 drivers and receivers. Its 500 kbps capability is substantially faster than the commonly used 100 kbps class, making it suitable for higher-speed supervisory, industrial-control, and instrumentation links. Designers must still account for propagation delay, bus loading, termination, connector surge exposure, and the characteristics of the installed cable.
Typical uses include industrial programmable logic controllers, factory automation equipment, data-acquisition systems, building-control gateways, and communications ports for test and measurement instruments. In these applications, the device converts logic-level data into differential bus signals and receives differential bus signals into CMOS-compatible logic levels. The 3.3 V supply also supports integration with modern low-voltage controllers and field-programmable gate arrays.
For a robust implementation, place the transceiver close to the bus connector, route the differential pair as a tightly coupled pair, and terminate the far end of the cable according to the system topology. Decoupling and protection components should be positioned to minimize high-current loops between the supply, device, and connector. Confirm pin-level enable, driver-enable, and receiver-enable behavior in the manufacturer datasheet before finalizing PCB connections.
This page combines the ADM3073EYRZ device identity, interface characteristics, family-level replacement candidates, application guidance, and practical PCB considerations. It also distinguishes verified product attributes from electrical details that require confirmation in the Analog Devices ADM3073E datasheet, helping engineers plan sourcing and schematic review efficiently.
Drop-in alternatives for ADM3073EYRZ — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.
Variants in this series
Same-series models that are drop-in compatible with ADM3073EYRZ (same form factor and footprint) — differing in Package, Product Type, Maximum Data Rate, Supply Voltage.
ADM3073EARZ
✅ Drop-InContact for price
View Datasheet →ADM3076EYRZ
✅ Drop-InContact for price
View Datasheet →ADM3077EARZ
✅ Drop-InContact for price
View Datasheet →ADM3072EARZ
✅ Drop-InContact for price
View Datasheet →SP3070EEN-L
✅ Drop-In📋 Reference alternative (not in catalog)
ADM3073EYRZ Specifications
| Product Type | Full-duplex RS-485/RS-422 transceiver |
| Supply Voltage | 3.3 V |
| Maximum Data Rate | 500 kbps |
| ESD Protection | ±15 kV |
| Interface Standards | RS-485 and RS-422 |
| Duplex Mode | Full duplex |
| Transceiver Configuration | 1 transmitter and 1 receiver |
| Package | 14-pin SOIC |
| Mounting Type | Surface mount |
| Number of Pins | 14 pins |
| RoHS Status | Compliant |
| REACH Status | Compliant |
ADM3073EYRZ 14-pin soic Pin Configuration Guide
Pin configuration for ADM3073EYRZ (14-pin soic package). Pin numbering, functions, and connection diagrams are defined in the manufacturer datasheet. Refer to it for the exact footprint and soldering guidelines.
No detailed pinout data available for ADM3073EYRZ.
Refer to the datasheet for full pin configuration.
Typical Applications
ADM3073EYRZ is suitable for 6 applications: Industrial PLC Communication, Factory Automation Equipment, Data Acquisition Systems, Building Control Gateways, Test and Measurement Instruments, Instrumentation and Sensor Networks.
Industrial PLC Communication
The ADM3073EYRZ fits industrial PLC links that require a 3.3 V controller to communicate over a balanced RS-485 bus at rates up to 500 kbps. Its full-duplex architecture supports separate differential transmit and receive paths, while ±15 kV ESD protection strengthens the connector-facing interface against electrostatic discharge. Place the transceiver near the bus connector and route the differential pair as a coupled pair. Confirm the actual bus topology, cable length, termination strategy, and fail-safe behavior in the Analog Devices ADM3073E datasheet, Rev. F, before deployment.
Recommended
Factory Automation Equipment
The ADM3073EYRZ can serve as the physical interface between factory automation controllers and remote I/O modules, motion-control electronics, or operator panels. A 500 kbps maximum data rate supports faster supervisory communication than 100 kbps-class buses, while the 3.3 V supply reduces the need for level translation from modern control logic. The ±15 kV ESD rating is useful near exposed cables but does not replace certified surge protection. Maintain a controlled ground relationship between attached equipment and select termination according to the multidrop network rather than placing termination at every node.
Recommended
Data Acquisition Systems
The ADM3073EYRZ is appropriate for data-acquisition equipment that must collect measurements from distributed sensors or instrument modules over a balanced RS-485 network. The full-duplex configuration simplifies designs requiring simultaneous command and response traffic, and the 500 kbps limit provides useful throughput for sampled laboratory and industrial monitoring data. Use low-ESR local supply decoupling, keep the transceiver and protection network close to the connector, and verify receiver input thresholds against the ground offsets present in the installed system.
Recommended
Building Control Gateways
The ADM3073EYRZ can interface a 3.3 V building-control gateway with RS-485 lighting, access-control, environmental, or HVAC controllers. Its 500 kbps capability supports responsive command traffic across several nodes when cable length and loading permit. The full-duplex configuration is particularly useful for gateways that exchange status and commands simultaneously. Because building wiring may connect equipment with different grounding systems, use isolation or surge protection where required, follow the recommended bus common-mode limits, and avoid treating the ±15 kV ESD rating as a complete lightning-protection solution.
Recommended
Test and Measurement Instruments
The ADM3073EYRZ is useful in test and measurement instruments that expose an RS-485 control or trigger port to remote fixtures. Its 3.3 V operation integrates directly with modern controller logic, while full-duplex operation can support continuous command and response traffic at rates up to 500 kbps. The 14-pin SOIC package simplifies replacement in an existing 14-SOIC footprint, but the device is obsolete, so new instruments should evaluate a current transceiver. For exposed bench connections, combine careful differential routing with connector-side surge protection and a defined ground reference.
Recommended
Instrumentation and Sensor Networks
The ADM3073EYRZ can connect a low-voltage controller to distributed instrumentation nodes using an RS-485 differential bus. Its 500 kbps maximum rate allows compact systems to aggregate commands and measurements efficiently, and the ±15 kV ESD protection improves tolerance to static discharge on field wiring. Differential signaling rejects common-mode noise encountered near motors and switching power stages. Validate cable length against the selected data rate, use a termination network appropriate to the bus topology, and confirm that all nodes share an allowable ground potential.
Recommended
Recommended Products Summary
Engineering reference data for ADM3073EYRZ — comparison, design guidance, and compliance information.
Selection Guide
Comparison with Alternatives
| Parameter | This Product | ADM3073EARZ | ADM3076EYRZ | ADM3077EARZ | ADM3072EARZ | SP3070EEN-L |
|---|---|---|---|---|---|---|
| Package | 14-SOIC | 14-SOIC | 14-SOIC | 14-SOIC | 14-SOIC | 14-SOIC |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Exar |
| Product Type | Full-duplex RS-485/RS-422 transceiver | Full-duplex RS-485/RS-422 transceiver | Full-duplex RS-485 transceiver | RS-485/RS-422 transceiver | RS-485/RS-422 transceiver | Differential RS-485/RS-422 line transceiver |
| Mounting Type | Surface mount | Surface mount | Surface mount | Surface mount | Surface mount | Surface mount |
Key Differentiators
- Full-duplex operation in a compact 14-SOIC interface (vs SP3070EEN-L)
- Established 14-SOIC family upgrade path (vs ADM3072EARZ)
- Explicit 3.3 V operation and ±15 kV ESD protection (vs ADM3077EARZ)
- Direct same-family ordering-code comparison (vs ADM3073EARZ)
Design Notes
Place the ADM3073EYRZ close to the RS-485 connector and route the differential pair as a tightly coupled pair on the same PCB layer. Keep the pair away from switching nodes, relay contacts, and high-current power paths. Connect local supply decoupling directly to the device power and ground pins, and place connector-side protection at the entry point so surge or discharge current does not flow through sensitive logic traces.
Do not assume that identical 14-pin SOIC packages imply identical behavior. Before using ADM3073EARZ, ADM3076EYRZ, ADM3077EARZ, ADM3072EARZ, or SP3070EEN-L, compare supply voltage, maximum data rate, receiver thresholds, fail-safe response, driver-enable polarity, and thermal limits. The target is obsolete, so preserve the original schematic and verify any substitute against the manufacturer datasheet rather than relying only on package dimensions.
Apply termination according to the physical bus topology, normally at the two physical endpoints of a long multidrop RS-485 network. Do not terminate every node because excessive loading can reduce signal margin. Use the data-rate-versus-cable-length guidance in the Analog Devices ADM3073E datasheet, Rev. F, and validate the installed network with worst-case node count, cable characteristic impedance, and grounding conditions.
The ±15 kV ESD rating protects the bus interface against electrostatic discharge, but it does not eliminate industrial surge, EFT, or lightning threats. Determine whether the installation requires an external surge-protection network, isolation, or a common-mode choke. Keep protective-return paths away from the differential signal pair and confirm that the selected protection component does not significantly degrade the intended 500 kbps operation.
Compliance Information
RoHS and REACH compliance are identified in the ADM3073 comparison information. AEC-Q100 qualification, lead-free status, halogen-free status, and conflict-minerals status are not confirmed.