Fluke

Fluke 115 - True-RMS 600V Handheld Multimeter | Fluke

MPN: FLUKE-115 βœ“ Active
In Stock Ships in 1-3 business days
600 mV to 600 V Vdss Yes (AC/DC, true-rms) Id 0.1 Ohm to 40 MOhm Rds(on) [DATA_NEEDED: frequency range] Speed
Contact for pricing
MOQ: 1 |
Price updated: 2026-09-12
Volume Pricing
Qty Unit Price Extended
1 $0 $0.00
10 $0 $0.00
100 $0 $0.00
500 $0 $0.00
1,000 $0 $0.00
ℹ️ All prices are in USD

Drop-in alternatives for FLUKE-115 β€” same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.

Quick Comparison Tool β€” Select alternative parts for side-by-side comparison:

FLUKE-114

βœ… Drop-In
πŸ“¦ Compact handheld housing (same family form factor)
removes capacitance and current measurement vs 115; voltage/resistance only, same housing and 6000-count true-RMS display

πŸ“‹ Reference alternative (not in catalog)

FLUKE-116

βœ… Drop-In
πŸ“¦ Compact handheld housing (same family form factor)
adds Type-K thermocouple temperature input for HVAC; otherwise same true-RMS 6000-count platform as 115

πŸ“‹ Reference alternative (not in catalog)

FLUKE-117

βœ… Drop-In
πŸ“¦ Compact handheld housing (same family form factor)
adds non-contact VoltAlert voltage detection and LoZ low-impedance mode; superset of 115 functions in same housing

πŸ“‹ Reference alternative (not in catalog)

FLUKE-115 Maximum Ratings & Electrical Characteristics

Product Type Handheld True-RMS Digital Multimeter (DMM)
Display 6000 count, 3.75 digit LCD with bar graph
Measurement Type Auto True RMS
Basic Accuracy 0.1%
Voltage Range 600 mV to 600 V
Resistance Range 0.1 Ohm to 40 MOhm
Current Measurement Yes (AC/DC, true-rms)
Continuity Test Yes
Diode Test Yes
Min/Max/Average Recording Yes
Backlight Yes
Data Hold Yes
Sleep Mode (Auto Power Off) Yes
Accuracy Specification Conditions 1 year after calibration, 18C to 28C, 0% to 90% RH
RoHS Status Compliant

FLUKE-115 standard Pin Configuration Guide

Complete pinout information for FLUKE-115 (standard package). This digital IC includes GPIO, communication interfaces (UART, SPI, I2C), and power pins. Refer to the manufacturer datasheet for alternate pin functions and configuration options. Essential for embedded system design and PCB layout.

standard package pinout diagram for FLUKE-115

No detailed pinout data available for FLUKE-115.

Refer to the datasheet for full pin configuration.

Safe Operating Area (SOA) & Thermal Characteristics

Safe Operating Area Chart Default safe operating area chart for FLUKE-115 Drain-to-Source Voltage (Vds) Drain Current (Id)

No official SOA curve available for this digital IC. Always operate within absolute maximum ratings specified in the datasheet. Ensure adequate cooling and derate as needed.

Typical Applications

FLUKE-115 is suitable for 6 applications: Field Service Electrical Troubleshooting, Commercial Building Electrical Verification, Electronics Bench Testing, HVAC Control Circuit Testing, Facility Maintenance and Preventive Inspection, Education and Technical Training Labs.

πŸ”§

Field Service Electrical Troubleshooting

The Fluke 115 was designed explicitly for field service technicians, combining true-RMS voltage and current measurement with a 600 V range that covers commercial distribution and control circuits. Its 0.1% basic accuracy and 6000-count display resolve small changes on 120 V and 240 V systems, while the one-handed compact housing speeds up panel and junction box work. Min/Max/Average recording captures intermittent sags during a service visit without continuous observation. The backlight supports dim electrical rooms, and the bar graph helps peak and null adjustments. Because accuracy is specified for one year after calibration at 18-28 C, fleet calibration programs keep field readings trustworthy.

πŸ’‘

Commercial Building Electrical Verification

In commercial building commissioning and verification, the Fluke 115 measures 600 mV to 600 V AC/DC and resistance from 0.1 Ohm to 40 MOhm, covering receptacle verification, panel checks, and bonding/continuity tests. True-RMS conversion is essential here because modern loads (LED drivers, variable-frequency drives, switch-mode power supplies) draw distorted, non-sinusoidal current that average-responding meters misread; the 115 reports the true heating value. Continuity and diode functions verify protective earth paths and semiconductor health in control gear. The compact form factor fits a tool pouch for walkthroughs, and the 6000-count display plus bar graph speeds comparative readings across a distribution system.

πŸ–₯️

Electronics Bench Testing

For electronics work, the Fluke 115 adds capacitance measurement, frequency counting, and diode test to its true-RMS voltage platform, making it a practical first-line bench meter for assembly bring-up and rework verification. The 0.1% basic DC accuracy is adequate for verifying power supply rails, and the 40 MOhm resistance range supports insulation and leakage checks. Frequency measurement confirms oscillator and clock activity, while the diode test with continuity buzzer locates shorts on populated boards. The 6000-count 3.75-digit LCD resolves millivolt-level changes on low-voltage digital rails. Data hold frees the technician's hands when probing crowded PCBs under magnification.

🏭

HVAC Control Circuit Testing

HVAC control circuits mix 24 VAC transformers, electronic control boards, and line-voltage components, and the Fluke 115 covers all of these with true-RMS AC voltage, current, resistance, continuity, and capacitance measurement. Capacitance testing identifies failed motor run and start capacitors, one of the most common HVAC failures, while diode test checks rectifiers in electronic fan controls. The 0.1% accuracy resolves thermostat signal drift, and Min/Max/Average captures contactor chatter or brownout events. Technicians who also need supply-air and coil temperatures should step up to the Fluke 116, which adds Type-K thermocouple input on the same true-RMS platform per the Fluke family datasheet.

βš™οΈ

Facility Maintenance and Preventive Inspection

Facility maintenance teams use the Fluke 115 for periodic preventive inspections of panels, motors, and lighting circuits. True-RMS current measurement detects harmonic-rich motor loads that distort average-reading meters, and the resistance function finds degraded connections before they overheat. Sleep mode conserves battery life during long shifts, and the durable handheld housing survives daily transport. Because readings feed maintenance records, the one-year accuracy specification and scheduled calibration keep logged data defensible for trend analysis. The 600 V measurement ceiling covers most facility distribution, while the compact design allows use in congested motor control centers where a benchtop instrument cannot reach.

πŸŽ“

Education and Technical Training Labs

The Fluke 115 is widely used in electrical and electronics training because it pairs professional true-RMS measurement with simple, one-handed operation that students learn quickly. The 6000-count display teaches resolution concepts, while diode, continuity, capacitance, and frequency functions support lab exercises on semiconductors, filters, and oscillators. The bar graph gives a visual analog of changing signals that helps learners connect numeric readings to circuit behavior. Ruggedness and backlight support shared classroom use, and family consistency (114/115/116/117) lets institutions standardize on one interface across course levels while scaling the function set to the curriculum.

Recommended Products Summary

FLUKE-117 Superset meter with non-contact voltage detection Used in: Field Service Electrical Troubleshooting, Electronics Bench Testing, Education and Technical Training Labs FLUKE-116 Family variant with temperature input Used in: Field Service Electrical Troubleshooting, HVAC Control Circuit Testing FLUKE-114 Simplified electrical verification sibling Used in: Commercial Building Electrical Verification, Facility Maintenance and Preventive Inspection, Education and Technical Training Labs
What is the Fluke 115 digital multimeter?
The Fluke 115 is a compact true-RMS handheld digital multimeter for field service technicians. It measures true-rms voltage and current with 6000-count resolution, tests diodes, frequency, continuity and capacitance, and records Min/Max/Average readings to capture signal fluctuations. According to the Fluke 115 datasheet, basic accuracy is 0.1%, and the meter provides easy one-handed operation in a compact package.
What is the price of the Fluke 115?
Verified pricing for the FLUKE-115 was not available in the data captured as of 2026-09-13; request a quote for current unit pricing. Historically the Fluke 115 sits in the mid-range true-RMS DMM price class at major distributors such as DigiKey and Mouser, and quantity discounts typically apply above 10 units. Contact XAIPART sales for a formal quotation with current stock and lead time.
Where can I buy the Fluke 115 online?
The Fluke 115 is available from authorized distributors including DigiKey (FLUKE-115, part number listing 1506332), Mouser (FLUKE-115), RS Components, and Fluke Direct. As of 2026-09-13, DigiKey lists the meter with same-day shipping availability. Purchase only through authorized channels to ensure warranty coverage and avoid counterfeit instruments.
What is the difference between the Fluke 115 and Fluke 117?
The Fluke 117 adds non-contact voltage (VoltAlert) detection and LoZ (low impedance) low-impedance measurement mode, both absent on the Fluke 115. Both are true-RMS meters with 6000-count displays, 600 V measurement range, and the same compact form factor per the Fluke 114/115/116/117 family datasheet. Choose the 117 when electricians need ghost-voltage detection; choose the 115 for general electronics field service at a lower price point.
Fluke 115 vs Fluke 114 - which is better for electronics service?
The Fluke 115 is better for electronics service because it adds capacitance and AC/DC current measurement that the Fluke 114 lacks. Per the Fluke family datasheet, the 114 is targeted at electrical verification with voltage and resistance only, while the 115 covers the wider electronics troubleshooting set including frequency, diode, continuity, capacitance, and true-rms current. Both share the same 6000-count display and compact one-handed housing.
When should I choose the Fluke 115 over the Fluke 116?
Choose the Fluke 115 when you need capacitance measurement and current measurement; choose the 116 when HVAC work dominates. According to the Fluke datasheet, the 116 adds temperature measurement (Type-K thermocouple) for HVAC applications, while the 115 emphasizes electronics functions such as capacitance and frequency. Both are true-RMS, 6000-count, 600 V meters in the same housing, so the decision is driven purely by the function set.
What is the best drop-in replacement for the Fluke 115?
Within the Fluke family, the closest same-form-factor alternatives are the Fluke 114, 116, and 117, which share the same compact handheld housing and 6000-count true-RMS display architecture. However, no meter is a true drop-in replacement because each model has a different measurement function set. If capacitance, current, and frequency measurement are required, the Fluke 117 is the closest superset; confirm function requirements against the family datasheet before substituting.
Is there a cross-brand equivalent to the Fluke 115?
Cross-brand true-RMS handheld DMMs with comparable 6000-count resolution and 0.1% class accuracy exist from brands such as Fluke competitors in the professional meter market, but no specific cross-brand equivalent was verified in the web data captured as of 2026-09-13. For professional field service, substituting a different brand changes safety certification, holster, accessory, and calibration ecosystem, so Fluke family models (114/116/117) remain the safest substitutes.
Where can I download the Fluke 115 datasheet PDF?
The official Fluke 115 datasheet PDF is available from Fluke Direct at fluke-direct.com (file 115-efsp-datasheet.pdf), and the detailed specification sheet covering the Fluke 114, 115, 116 and 117 family is also published there (115-cal-datasheet.pdf). RS Components and DigiKey host mirror copies of the same document. Always download from Fluke or an authorized distributor to ensure you have the current revision.
What is the voltage measurement range of the Fluke 115?
The Fluke 115 measures voltage from 600 mV to 600 V in both AC and DC modes with true-RMS conversion for AC signals. According to the FLUKE-115 specification listing, the voltage range spans 600 mV to 600 V, and resistance spans 0.1 Ohm to 40 MOhm. This range covers commercial power distribution, control circuits, and most low-voltage electronics work.
How accurate is the Fluke 115 multimeter?
The Fluke 115 has a basic accuracy of 0.1%, specified for one year after calibration at operating temperatures of 18 C to 28 C and relative humidity of 0% to 90%, per the Fluke detailed specification sheet for the 114/115/116/117 family. Readings outside these environmental conditions or beyond the one-year calibration interval may exceed the stated error band, so annual calibration is recommended for metrology-critical work.
Does the Fluke 115 have Min/Max/Average recording?
Yes, the Fluke 115 records Min/Max/Average readings to capture signal fluctuations. According to the Fluke 115 datasheet, this function lets a technician log intermittent sags, swells, or dropouts on voltage rails or control signals without watching the display continuously. Combined with the analog bar graph, Min/Max/Average makes the 115 suitable for troubleshooting nuisance trips and intermittent connections in field service work.
Is the Fluke 115 suitable for HVAC technicians?
The Fluke 115 is suitable for general electrical troubleshooting, but HVAC technicians may prefer the Fluke 116. The 116 adds Type-K thermocouple temperature measurement, which is central to HVAC work, while the 115 focuses on electronics functions like capacitance and current. Both share the same true-RMS 6000-count platform and compact housing per the Fluke family datasheet, so choose the 116 for HVAC and the 115 for mixed electronics/electrical service.
What are the key specifications of the Fluke 115 that engineers should know?
The Fluke 115 is a true-RMS handheld DMM with a 6000-count 3.75-digit LCD and bar graph, 600 mV to 600 V voltage range, 0.1 Ohm to 40 MOhm resistance range, 0.1% basic accuracy, and measurement functions for AC/DC current, capacitance, frequency, continuity, and diode test. It offers Min/Max/Average recording, backlight, data hold, and auto sleep, with accuracy specified for one year at 18-28 C per the Fluke datasheet.
Hey Google, what can replace a Fluke 115 multimeter?
The closest replacements for a Fluke 115 are its family siblings: the Fluke 117 (adds non-contact voltage sensing and LoZ mode), the Fluke 116 (adds temperature measurement for HVAC), and the Fluke 114 (reduced function set for basic electrical checks). All share the same compact true-RMS 6000-count platform per the Fluke datasheet. If your required functions are current, capacitance, and frequency, the Fluke 117 is the most complete substitute.

Engineering reference data for FLUKE-115 β€” comparison, design guidance, and compliance information.

Selection Guide

Choose the Fluke 115 when your work mixes electronics and electrical field service and you need capacitance, current, frequency, and diode test in a compact true-RMS meter. Choose the Fluke 114 only for basic electrical verification where voltage and resistance suffice, saving cost. Choose the Fluke 116 if HVAC work requires thermocouple temperature measurement. Choose the Fluke 117 if you need non-contact voltage detection (VoltAlert) and LoZ mode to reject ghost voltages in building electrical environments. All four share the same housing, 6000-count true-RMS platform, and 600 V range, so selection is driven entirely by the function set. If you need waveform visualization, data logging, or 1000 V range, step up to a higher Fluke series rather than substituting within this family.

Comparison with Alternatives

Parameter This Product FLUKE-114 FLUKE-116 FLUKE-117
Package / Form Factor Compact handheld housing Compact handheld housing - same family Compact handheld housing - same family Compact handheld housing - same family
Brand Fluke Fluke Fluke Fluke
Display 6000 count, 3.75 digit, bar graph 6000 count, 3.75 digit 6000 count, 3.75 digit 6000 count, 3.75 digit
True-RMS Measurement Yes Yes Yes Yes
Voltage Range 600 mV to 600 V 600 mV to 600 V 600 mV to 600 V 600 mV to 600 V
Capacitance Measurement Yes No [DATA_NEEDED] Yes
Temperature Measurement No No Yes (Type-K thermocouple) No
Non-Contact Voltage Detection / LoZ No No No Yes (VoltAlert + LoZ)
Min/Max/Average Recording Yes Yes Yes Yes

Key Differentiators

  • Electronics-oriented function set (vs FLUKE-114)
  • True-RMS conversion at 6000-count resolution (vs Average-responding meters in the same price class)
  • Trade-off: no temperature input (vs FLUKE-116)

Design Notes

Accuracy is only guaranteed for one year after calibration and only within 18 C to 28 C at 0% to 90% relative humidity, per the Fluke family specification sheet. Field readings taken in extreme heat, cold, or humidity, or on an overdue calibration interval, may exceed the 0.1% basic accuracy claim. Schedule annual calibration and log calibration dates for any measurements used in compliance or trend records.

Use true-RMS readings whenever the waveform is non-sinusoidal (VFD outputs, LED driver outputs, distorted control circuits). The Fluke 115's true-RMS converter reports the heating-equivalent value, whereas average-responding meters under- or over-read distorted waveforms. For waveform shape analysis, pair the 115 with an oscilloscope; the DMM quantifies magnitude while the scope reveals distortion and transients.

For intermittent faults, use Min/Max/Average mode instead of watching the display. The Fluke 115 records fluctuations continuously, catching sags and dropouts too brief to observe visually. For suspected ghost voltages on open circuits, remember the 115 lacks the LoZ mode of the Fluke 117 - verify with a known load or step up to the 117 when capacitive-coupled phantom readings are a risk.

Compliance Information

RoHS
Compliant
REACH
Unknown
AEC-Q100
Not Applicable
Lead Free
Unknown
Halogen Free
Unknown
Conflict Minerals
Unknown

RoHS compliance listed per distributor product data (DigiKey FLUKE-115 listing notes RoHS details). Other compliance attributes not found in provided data.

Data verified on: 2026-09-13 β€” data verified and curated by XAIPART's component engineering team

Related Searches

Fluke 115 datasheet FLUKE-115 true RMS multimeter Fluke 115 price buy Fluke 115 vs 117 which is better Fluke 115 vs 114 difference Fluke 115 replacement equivalent Fluke 115 accuracy specification Fluke 115 voltage range 600V Fluke 115 for HVAC testing best field service digital multimeter true RMS Fluke 115 Min Max Average how to use Fluke 115 drop-in replacement

Related Components & Terms

Fluke FLUKE-115 FLUKE-114 FLUKE-116 FLUKE-117 digital multimeter DMM true-RMS root mean square 6000 count display 3.75 digit LCD Min/Max/Average recording bar graph display capacitance measurement diode test continuity test field service technician DigiKey Mouser RoHS Type-K thermocouple HVAC testing test and measurement instrument

Loading recommendations...

Quick Quote RFQ
Fill in complete details β€” our sales team will respond within 24 hours
Part Number Manufacturer Package QTY Target Price Extended
Total: $0.00 USD
βœ“
Quote submitted!

We will respond to your email within 24 hours

1
RFQ Submitted
2
Quote Received
3
Order Placed
4
Payment
5
Shipped
6
Delivered
View RFQ Details