HCI-PSU-6600-AC Overview

The Cisco HCI-PSU-6600-AC is a 1400 W hot-plug, redundant AC power supply module designed for Cisco UCS C-Series rack servers and Cisco UCS 6600 Series Fabric Interconnects, accepting 120 V AC and 230 V AC input with a port-side exhaust airflow design in a swappable server power module package.

A server power supply unit (PSU) is the power conversion stage of the power management hierarchy in data center hardware: it converts utility AC input into the regulated DC rails that feed server motherboards, fabric interconnects, and compute nodes. Hot-plug redundant PSUs such as this module allow replacement without powering down the host, which is the foundation of high-availability server architectures.

Key features of the HCI-PSU-6600-AC include a 1400 W (1.4 kW) continuous output rating, dual-range AC input supporting both 120 V AC and 230 V AC utility feeds, hot-plug and redundant operation for zero-downtime maintenance, and a port-side exhaust airflow scheme that matches the cooling architecture of Cisco UCS 6600 Series chassis. Distributor listings also classify the 6600 family as 80 PLUS Platinum efficiency class, reducing wasted heat and operating cost in dense racks.

Technically, the module integrates AC-to-DC conversion, active power factor correction, output regulation, and status LED indication in a single field-replaceable unit. According to the Cisco UCS 6600 Series Fabric Interconnect Installation and Service Guide, each 1400W port-side exhaust AC power supply module (UCS-PSU-6600-AC) has a status LED providing visual indication of operational and performance state, simplifying fault isolation in production environments.

Typical applications include powering Cisco UCS 6600 Series Fabric Interconnects that form the management and communication backbone for UCS X-Series compute nodes, the UCS X9508 Chassis, B-Series blade servers, and C-Series rack servers, as well as hyperconverged infrastructure (HCI) deployments - the origin of the HCI prefix in this MPN.

When designing or maintaining systems with this PSU, verify airflow direction compatibility: port-side exhaust modules must not be mixed with port-side intake modules in the same chassis, as mismatched airflow disrupts the thermal design.

This page synthesizes distributor pricing, lifecycle information, drop-in family alternatives, and practical installation design notes not found in any single manufacturer or distributor listing.

Pricing referenced as of 2026-10-19.

Drop-in alternatives for HCI-PSU-6600-AC — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.

Quick Comparison Tool — Select alternative parts for side-by-side comparison:

UCS-PSU-6600-AC

✅ Drop-In
📦 Hot-plug server PSU module
same-spec family part: identical 1400 W rating, 120/230 V AC input, port-side exhaust airflow, hot-plug redundant operation; HCI- prefix denotes HCI channel allocation vs standard UCS spare numbering

📋 Reference alternative (not in catalog)

UCS-PSU-6600-AC

✅ Drop-In
📦 Hot-plug server PSU module
identical 1400 W AC module sold as new stock at $1,315.00 as of 2026-10-19; channel/condition differs, not the hardware

📋 Reference alternative (not in catalog)

HCI-PSU-6600-AC Specifications (manufacturer-published)

Total Output Power 1400 W (1.4 kW)
Input Voltage Range 120 V AC, 230 V AC
Input Type AC
Efficiency Class 80 PLUS Platinum (6600 family, per distributor listing)
Airflow Direction Port-side exhaust
Hot-Plug Support Yes
Redundancy Support Yes (redundant configuration)
Compatibility Cisco UCS C-Series rack servers, UCS 6600 Series Fabric Interconnects
Status Indication Status LED (operational and performance)
Form Factor Hot-plug server PSU module
Product Family Cisco UCS 6600 power supply family
Application Platform Cisco Unified Computing System (UCS)
Module Color Code Blue (per Cisco 6600 install guide)

HCI-PSU-6600-AC Interfaces & Connectors

HCI-PSU-6600-AC exposes the following interfaces and connectors as published by the manufacturer: Power Input. Expansion header pinout, connector pin numbering, and electrical limits are defined in the manufacturer documentation.

Power Input 120 V AC, 230 V AC

Refer to the manufacturer documentation for the full expansion header pinout and connector pin numbering.

Power & Thermal Characteristics

Power Input 120 V AC, 230 V AC

Power input and thermal parameters for HCI-PSU-6600-AC as published by the manufacturer.

Typical Applications

HCI-PSU-6600-AC is suitable for 6 applications: Cisco UCS 6600 Fabric Interconnect Power, Hyperconverged Infrastructure (HCI) Rack Servers, Data Center Redundant Power (N+1) Configurations, UCS X-Series and Blade Backend Fabric, Enterprise Spares Inventory and Field Service, Global 120V/230V Mixed-Voltage Data Centers.

🖥️

Cisco UCS 6600 Fabric Interconnect Power

The HCI-PSU-6600-AC is the designated 1400 W port-side exhaust AC power supply for Cisco UCS 6600 Series Fabric Interconnects, which form the management and communication backbone of the Cisco Unified Computing System. Its hot-plug redundant architecture allows a failed module to be swapped while the fabric interconnect continues forwarding traffic, protecting the control plane for X-Series compute nodes, the X9508 Chassis, and B-Series blades downstream. The dual 120/230 V AC input supports deployment in any global data center, and the blue color coding plus status LED simplify correct installation and fault identification during maintenance windows.

🧩

Hyperconverged Infrastructure (HCI) Rack Servers

The HCI prefix in HCI-PSU-6600-AC denotes allocation to Cisco Hyperconverged Infrastructure builds based on UCS C-Series rack servers. HCI nodes concentrate compute, storage, and network virtualization on a single server, so power supply failure directly impacts storage cluster quorum and workload availability. The 1400 W rating covers the elevated power draw of dense NVMe and GPU-assisted HCI nodes, while hot-plug redundancy permits live replacement. Using matched port-side exhaust modules keeps the chassis thermal design intact, which is critical because HCI nodes typically run at higher sustained utilization than general-purpose servers, increasing heat load per rack unit.

⚡

Data Center Redundant Power (N+1) Configurations

In N+1 power designs, the HCI-PSU-6600-AC operates as one of several parallel modules sharing the load, so any single module can fail or be removed without interrupting the server. The 120/230 V AC dual input lets each PSU connect to independent power domains or UPS branches, achieving A/B feed redundancy at the module level. The status LED gives operators immediate visual confirmation of module health during rack walk-throughs, and hot-plug capability means the failed unit is replaced with zero downtime. This is the standard high-availability pattern for production UCS deployments per Cisco's UCS 6600 installation documentation.

🌐

UCS X-Series and Blade Backend Fabric

Cisco UCS 6600 Series Fabric Interconnects - powered by 1400W PSU-6600-AC-class modules - provide the management and communication backbone for UCS X-Series compute nodes, the UCS X9508 Chassis, and B-Series blade servers per the January 2026 Cisco data sheet. In this role the PSU protects not one server but the entire downstream compute estate: a fabric interconnect power failure would sever connectivity for thousands of blades and X-Series nodes. Specifying genuine 1400 W port-side exhaust modules with N+1 redundancy is therefore a fabric-level availability requirement, not merely a server-level one.

🔧

Enterprise Spares Inventory and Field Service

Enterprise data center teams keep HCI-PSU-6600-AC / UCS-PSU-6600-AC modules as cold or warm spares for field replacement. Because lifecycle dates track the parent UCS C-Series and 6600 platforms (per eol.network), procurement teams should size the spares pool against the platform's remaining support window. The module's hot-plug nature means a trained technician can complete replacement in minutes without scheduling downtime, and the status LED verifies the new module is healthy before the maintenance window closes. Channel flexibility matters here: the same-spec UCS- numbered part is stocked more broadly than the HCI- variant.

🏭

Global 120V/230V Mixed-Voltage Data Centers

Organizations operating data centers across regions with differing utility voltages benefit from the dual 120 V AC / 230 V AC input of the HCI-PSU-6600-AC: one spares SKU serves North American 120 V sites and international 230 V sites, simplifying logistics and reducing inventory duplication. Distributor listings (Ingram Micro, PC-Canada, Cendirect) explicitly document the dual input range at the 1400 W (1.4 kW) rating. When deploying at 120 V in high-load configurations, verify any input-voltage derating in official Cisco documentation and ensure branch circuits and power cords are rated for the actual continuous current draw.

Recommended Products Summary

UCS-PSU-6600-AC Same-spec redundant PSU module for N+1 configuration Used in: Cisco UCS 6600 Fabric Interconnect Power, Hyperconverged Infrastructure (HCI) Rack Servers, Data Center Redundant Power (N+1) Configurations, UCS X-Series and Blade Backend Fabric, Enterprise Spares Inventory and Field Service, Global 120V/230V Mixed-Voltage Data Centers
What is the output power rating of the Cisco HCI-PSU-6600-AC?
The Cisco HCI-PSU-6600-AC is rated for 1400 W (1.4 kW) of continuous output power. According to Cisco distributor listings (CDW, Ingram Micro, PC-Canada), it is a hot-plug, redundant AC power supply accepting 120 V AC or 230 V AC input, with port-side exhaust airflow. It powers Cisco UCS C-Series rack servers and UCS 6600 Series Fabric Interconnects and carries the blue color code used for 1400W port-side exhaust AC modules in the 6600 chassis family.
What is the price of HCI-PSU-6600-AC?
As of 2026-10-19, distributor pricing for the same-spec family part UCS-PSU-6600-AC is listed at approximately $1,315.00 USD (brand new, per Cendirect). The HCI-PSU-6600-AC variant is listed through Cisco Direct channels such as CDW; final pricing varies by channel, quantity, and support contract. Contact XAIPART for a volume quote on quantities above 10 units, where tiered discounts apply.
Where can I buy HCI-PSU-6600-AC online?
The HCI-PSU-6600-AC is available through Cisco Direct resellers such as CDW (cdw.com), which lists it under Server Accessories. The same-spec family part UCS-PSU-6600-AC is stocked by Ingram Micro, Tech-America, PC-Canada, Cendirect, and ICD. XAIPART also supplies this module with tiered quantity pricing - request a quote directly on this page. Always verify the airflow direction (port-side exhaust) matches your chassis before ordering.
What is the difference between HCI-PSU-6600-AC and UCS-PSU-6600-AC?
The HCI-PSU-6600-AC and UCS-PSU-6600-AC belong to the same specification family: both are Cisco 1400 W AC power supplies with 120/230 V AC input, hot-plug redundant operation, and port-side exhaust airflow for the 6600 series. The HCI prefix denotes allocation to Cisco Hyperconverged Infrastructure (HCI) configurations, while UCS- is the standard UCS spare numbering. Per ICD's cross-reference listing, these same-spec parts are typically interchangeable, subject to your system's compatibility verification.
Can UCS-PSU-6600-AC replace HCI-PSU-6600-AC?
Yes, in most cases the UCS-PSU-6600-AC serves as the drop-in equivalent for the HCI-PSU-6600-AC. Both are 1400 W, 80 PLUS Platinum-class AC power supplies for the 6600 platform with identical input range (120/230 V AC), hot-plug redundant operation, and port-side exhaust airflow. ICD lists them as same-spec, typically interchangeable parts. Because Cisco spares are allocated by configuration channel, confirm the replacement is recognized by your specific chassis firmware and service contract before deploying it in production.
Is HCI-PSU-6600-AC hot-pluggable and redundant?
Yes. According to CDW's product listing, the HCI-PSU-6600-AC is a hot-plug, redundant power supply. Hot-plug capability means the module can be inserted or removed from a powered-on chassis without shutting down the system, while redundancy means two or more modules share the load so that a single PSU failure does not interrupt server operation. Each module has a status LED that provides visual indication of operational state, per the Cisco UCS 6600 Series installation guide.
What does port-side exhaust airflow mean on the HCI-PSU-6600-AC?
Port-side exhaust means the PSU pulls air in from the port side of the chassis and exhausts it out the opposite side, matching the front-to-back cooling direction of Cisco UCS 6600 Series Fabric Interconnects. Per the Cisco 6600 install guide, these 1400W port-side exhaust AC modules are colored blue. Critical warning: never mix port-side exhaust and port-side intake PSUs in the same chassis - mismatched airflow directions disrupt the designed thermal path and can cause overheating and forced shutdowns.
Which Cisco platforms are compatible with the HCI-PSU-6600-AC?
The HCI-PSU-6600-AC powers Cisco UCS C-Series rack servers in HCI configurations and the Cisco UCS 6600 Series Fabric Interconnects. According to the Cisco UCS 6600 Series data sheet (updated January 2026), the 6600 Fabric Interconnects provide the management and communication backbone for UCS X-Series compute nodes, the UCS X9508 Chassis, UCS B-Series blade servers, the UCS 5108 B-Series Chassis, and integrated C-Series rack servers - all of which depend on these PSU modules for power.
Where can I download the HCI-PSU-6600-AC datasheet PDF?
Cisco hosts the power supply data sheets on its official datasheet listing page at cisco.com/c/en/us/products/interfaces-modules/power-supply/datasheet-listing.html. Installation-level details, including PSU LED behavior and airflow rules, are documented in the Cisco UCS 6600 Series Fabric Interconnect Installation and Service Guide on cisco.com. Detailed electrical specifications (input frequency, output rails, MTBF) are not fully published in the public listings captured for this page and should be confirmed against the official Cisco data sheet before design sign-off.
What are the key specifications of the HCI-PSU-6600-AC that engineers should know?
The five facts engineers need: (1) 1400 W continuous output; (2) universal-style AC input accepting 120 V AC or 230 V AC; (3) hot-plug and redundant operation for zero-downtime service; (4) port-side exhaust airflow, blue color-coded, must not be mixed with intake modules; (5) compatibility limited to Cisco UCS C-Series and UCS 6600 Series platforms. These figures come from Cisco distributor listings (CDW, Ingram Micro) and the Cisco UCS 6600 installation guide.
Is the HCI-PSU-6600-AC still supported by Cisco?
According to eol.network, the HCI-PSU-6600-AC is a power supply for the Cisco UCS C-Series rack server platforms, and component lifecycle dates track the parent platform: when the platform line is retired, its modules and spares retire with it. As of the January 2026 update of the UCS 6600 Series data sheet, the platform remains active and documented. Check the Cisco End-of-Life policy page or eol.network for the exact current lifecycle milestone dates before planning long-term spares inventory.
What is the best Cisco equivalent for HCI-PSU-6600-AC?
The best Cisco (same-brand) equivalent is the UCS-PSU-6600-AC, the 1400 W Platinum-class port-side exhaust AC power supply for the UCS 6600 platform. It matches the HCI-PSU-6600-AC in wattage (1400 W), input range (120/230 V AC), airflow direction, hot-plug redundant operation, and chassis compatibility, per ICD's same-spec cross-reference. Within the broader Cisco power supply family, 850 W AC 80+ Platinum and 1600 W AC 80+ Titanium port-inlet spares exist but differ in wattage and airflow and are NOT interchangeable - verify chassis compatibility first.
Does the HCI-PSU-6600-AC support both 120V and 230V input?
Yes. Multiple distributor listings (Ingram Micro, Cendirect, PC-Canada) specify the module accepts 120 V AC and 230 V AC input while delivering its 1400 W (1.4 kW) output. This dual-range input allows deployment in North American 120 V infrastructure and international 230 V data centers with the same hardware. Note that available output power can be input-voltage-dependent in high-density server PSUs in general; confirm derating behavior at 120 V input in the official Cisco documentation when loading the PSU near its 1400 W rating.
What status LED indications does the 6600 PSU provide?
Per the Cisco UCS 6600 Series Fabric Interconnect Installation and Service Guide, each 1400W port-side exhaust AC power supply module has a status LED that provides a visual indicator of operational and performance information. This lets data center technicians identify healthy, failed, or degraded PSU states at a glance during walk-through inspections without connecting to the management controller. For detailed LED color/pattern definitions, consult the LED section of the official Cisco 6600 installation guide on cisco.com.
Should I choose the 1400W PSU-6600-AC or a higher-wattage Cisco PSU spare?
Choose the 1400 W PSU-6600-AC family when your chassis is a UCS 6600 Series Fabric Interconnect or a C-Series HCI configuration that specifies 1400 W port-side exhaust AC modules - Cisco power supplies are chassis-keyed and airflow-coded, so higher-wattage spares (such as the 1600 W Titanium port-inlet spare) are physically and thermally incompatible. If your deployment runs at 230 V AC with heavy compute loads, stay within the 1400 W rating and use N+1 redundancy rather than oversizing. Always match wattage, airflow direction, and color code to the chassis bill of materials.

Engineering reference data for HCI-PSU-6600-AC — comparison, design guidance, and compliance information.

Selection Guide

Choose the HCI-PSU-6600-AC when you are provisioning or maintaining a Cisco UCS C-Series hyperconverged infrastructure build or a UCS 6600 Series Fabric Interconnect that specifies 1400 W port-side exhaust AC power modules. It is the only correct choice for these chassis: Cisco server PSUs are keyed by wattage, airflow, and color code, so 850 W Platinum or 1600 W Titanium spares will not fit or will break the thermal design. If the HCI- variant is unavailable or your contract allows it, the same-spec UCS-PSU-6600-AC is typically interchangeable per ICD's cross-reference - verify chassis firmware recognition first. For deployments outside Cisco UCS 6600/C-Series hardware, do not use this module; select a PSU matched to your platform's form factor, wattage, and airflow specification instead.

Comparison with Alternatives

Parameter This Product UCS-PSU-6600-AC
Package Hot-plug server PSU module (6600 family) Hot-plug server PSU module (6600 family) - same
Brand Cisco Cisco - same
Output Power 1400 W 1400 W
Input Voltage 120 V AC, 230 V AC 120 V AC, 230 V AC
Airflow Direction Port-side exhaust (blue) Port-side exhaust (blue)
Hot-Plug / Redundant Yes / Yes Yes / Yes
Efficiency Class 80 PLUS Platinum (6600 family per distributor listing) 80 PLUS Platinum (per ICD listing)
Price (qty 1, as of 2026-10-19) $1,315.00 (same-spec family reference price) $1,315.00 (Cendirect, new)

Key Differentiators

  • Zero-downtime hot-plug replacement (vs Fixed (non-hot-plug) server power supplies)
  • Dual-range AC input for global fleets (vs Single-region 1400 W server PSUs)
  • Airflow-coded thermal integration (vs Generic 1400 W ATX PSUs)

Design Notes

Never mix airflow directions in one chassis. The HCI-PSU-6600-AC is a port-side exhaust (blue) module; Cisco also ships port-side intake variants in other families (e.g., port-inlet spares). Installing an intake module into an exhaust-designed chassis reverses the thermal path, causing localized overheating and potential forced shutdown. Verify the color code and airflow arrow on the module handle before insertion, and audit all PSU slots after any third-party or multi-site sparing event.

Plan branch circuits for the actual continuous draw, not just the 1400 W nameplate. At 230 V AC the module draws roughly 6-7 A at full load (estimated: 1400 W divided by 230 V, ignoring efficiency margin); at 120 V AC this roughly doubles, so confirm cord ratings and PDU branch capacity, and check official Cisco documentation for any output derating at 120 V input before running the PSU near full load in North American deployments.

Lifecycle planning: per eol.network, component dates for HCI-PSU-6600-AC track the parent UCS C-Series / 6600 platform - spares retire when the platform retires. If your refresh cycle extends beyond the platform's announced last-support date, stock sufficient same-spec UCS-PSU-6600-AC spares now, since channel availability of the HCI- variant is narrower than the UCS- variant.

Compliance Information

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Lead Free
Unknown
Halogen Free
Unknown
Conflict Minerals
Unknown

Compliance declarations were not present in the retrieved distributor listings; consult the official Cisco power supply data sheet and Cisco's corporate compliance documentation. Safety certifications not published in retrieved data.

Data verified on: 2026-10-19 — data verified and curated by XAIPART's component engineering team

Related Searches

HCI-PSU-6600-AC HCI-PSU-6600-AC datasheet Cisco HCI-PSU-6600-AC 1400W power supply UCS-PSU-6600-AC vs HCI-PSU-6600-AC difference HCI-PSU-6600-AC replacement equivalent Cisco UCS 6600 port-side exhaust power supply HCI-PSU-6600-AC price buy Cisco UCS C-Series 1400W AC PSU hot-plug redundant HCI-PSU-6600-AC compatible UCS 6600 fabric interconnect what is the difference between HCI-PSU-6600-AC and UCS-PSU-6600-AC Cisco 6600 PSU status LED airflow blue HCI-PSU-6600-AC lifecycle EOL dates

Related Components & Terms

Cisco HCI-PSU-6600-AC UCS-PSU-6600-AC Cisco UCS 6600 Series Fabric Interconnect Cisco UCS C-Series rack servers Cisco Unified Computing System (UCS) hot-plug power supply redundant power supply port-side exhaust airflow 80 PLUS Platinum 1400 W power supply server PSU module power management IC hierarchy RoHS hyperconverged infrastructure (HCI) Cisco UCS X9508 Chassis UCS X-Series compute nodes data center N+1 redundancy 120 V AC / 230 V AC input status LED
Quick Quote RFQ
Fill in complete details — our sales team will respond within 24 hours
Part Number Manufacturer Package QTY Target Price Extended
Total: $0.00 USD
✓
Quote submitted!

We will respond to your email within 24 hours

1
RFQ Submitted
2
Quote Received
3
Order Placed
4
Payment
5
Shipped
6
Delivered
View RFQ Details