MAX181CCPL Overview

The Maxim Integrated MAX181CCPL is a complete 8-channel, 12-bit data-acquisition system (DAS) housed in a 40-pin PDIP (Plastic DIP) through-hole package. It integrates a successive-approximation analog-to-digital converter, 8 analog input channels, a track/hold amplifier, and an on-chip reference, delivering up to 100 ksps throughput from a single +5 V supply. The 'CC' grade operates over the commercial 0°C to +70°C temperature range, and the parallel word-access interface simplifies connection to 8-bit and 16-bit microprocessors or microcontrollers.

What is a Data-Acquisition System? A DAS is a mixed-signal integrated circuit that combines an analog front end (multiplexer, sample-and-hold, and ADC) with digital control logic in a single chip, replacing the discrete ADC-plus-mux-plus-reference designs of the past. Within the broader converter hierarchy, a DAS sits above stand-alone ADCs and below full system-on-chip solutions; MAX181-class devices belong to the successive-approximation register (SAR) ADC family, prized for deterministic latency and ease of microprocessor interfacing. By integrating the reference and analog switches, Maxim's DAS parts reduce board area, lower BOM cost, and remove the burden of matching discrete analog stages.

Key features of the MAX181CCPL include 12-bit resolution with ±½ LSB linearity (typical), an on-chip 5 V reference (with external override option), software-configurable unipolar/bipolar input ranges (0 V to 5 V or ±5 V / ±10 V / 0 V to 10 V depending on external scaling), and a hardware-mode or software-mode channel scan sequencer. The device also offers an interrupt output at end-of-conversion, low power dissipation (~75 mW typical at 100 ksps), and single +5 V operation. The 40-pin PDIP footprint remains compatible with legacy through-hole test fixtures and breadboard prototypes.

Architecturally, the MAX181CCPL uses a charge-redistribution successive-approximation ADC core with a capacitive DAC, which provides inherent sample-and-hold action and eliminates the need for an external SHA. The on-chip precision reference is laser-trimmed at the factory, and an external reference pin allows system designers to substitute higher-accuracy or ratiometric references when required. The parallel interface supports either 8-bit (two read cycles) or 16-bit (single read) data transfer, with chip-select and read-strobe handshaking that map directly to 8051, 68HC11, and similar MCU buses.

Typical applications include industrial process-control front ends, multi-channel data loggers, instrumentation front panels, and portable test equipment. The 8-channel count suits it for monitoring thermocouple banks, RTD arrays, strain-gauge bridges, and 4 mA to 20 mA current-loop sensors. Designers also use the MAX181CCPL in legacy microprocessor-based factory automation cards where a parallel-bus ADC eliminates the need for an SPI/QSPI peripheral.

When designing with the MAX181CCPL, pay attention to analog-input protection: the analog inputs can be damaged by overvoltage transients, so series resistors and clamping diodes networks are recommended for industrial applications. Also, because the part uses a successive-approximation core, the analog input must remain stable during the conversion window (typically 8 µs to 10 µs); if the source impedance is too high, add an external buffer to avoid conversion errors.

This page synthesizes distributor pricing, drop-in Maxim Integrated alternatives, and practical design notes not found in the manufacturer datasheet alone.

Drop-in alternatives for MAX181CCPL — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.

Variants in this series

Same-series models that are drop-in compatible with MAX181CCPL (same form factor and footprint) — differing in Package, Resolution, Input Type, Mounting Type, Operating Temperature Range.

Maxim Integrated
Package: 40-pin PDIP (PL)
Resolution: 12 bit
Mounting Type: Through-Hole (DIP)
Compare with MAX181CCPL →
Maxim Integrated
Package: 40-pin PDIP
Resolution: 12 bit
Input Type: Single-Ended / Bipolar (software configurable)
Compare with MAX181CCPL →

Quick Comparison Tool — Select alternative parts for side-by-side comparison:

MAX181CCPL+

✅ Drop-In
📦 PDIP-40
same die and PDIP-40 footprint, lead-free RoHS terminal finish (Pb-free vs SnPb)

📋 Reference alternative (not in catalog)

MAX181CEPL+

✅ Drop-In
📦 PDIP-40
extended -40C to +85C industrial temp grade vs commercial 0C to +70C, same pinout

📋 Reference alternative (not in catalog)

MAX181BCPL+

✅ Drop-In
📦 PDIP-40
earlier silicon revision, wider linearity tolerance, same PDIP-40 pinout

📋 Reference alternative (not in catalog)

MAX181AEPL+

✅ Drop-In
📦 PDIP-40
initial silicon revision, extended -40C to +85C temp grade, same PDIP-40 pinout

📋 Reference alternative (not in catalog)

MAX181ACPL+

✅ Drop-In
📦 PDIP-40
initial silicon revision, commercial 0C to +70C temp grade, same PDIP-40 pinout

📋 Reference alternative (not in catalog)

MAX181CCPL Maximum Ratings & Electrical Characteristics

Resolution 12 bits
Number of Analog Input Channels 8
Sampling Rate 100 ksps
ADC Architecture Successive Approximation (SAR)
Input Type Single-Ended, Multiplexed
Data Interface Parallel (Word Access)
Supply Voltage +5 V single supply
On-Chip Reference Yes (5 V, internal)
Sample-and-Hold Internal (Track/Hold)
Operating Temperature Range 0°C to +70°C (Commercial 'C' grade)
Package PDIP-40 (Plastic DIP, 0.600 inch / 15.24 mm)
Mounting Type Through-Hole
Temperature Grade Commercial
Power Dissipation (typ) 75 mW at 100 ksps

MAX181CCPL pdip-40 (plastic dip, 0.600 inch / 15.24 mm) Pin Configuration Guide

Pin configuration for MAX181CCPL (pdip-40 (plastic dip, 0.600 inch / 15.24 mm) package). This analog component features input, output, and power supply pins. Refer to the manufacturer datasheet for offset null, compensation, and enable pin configurations. Ideal for signal conditioning and amplifier circuits.

pdip-40 (plastic dip, 0.600 inch / 15.24 mm) package pinout diagram for MAX181CCPL

No detailed pinout data available for MAX181CCPL.

Refer to the datasheet for full pin configuration.

Typical Applications

MAX181CCPL is suitable for 6 applications: Industrial Process Control Front End, Multi-Channel Data Logger, Instrumentation Front Panel, Legacy Microprocessor-Based Factory Card, Portable Test Equipment, Strain-Gauge / Bridge Transducer Reader.

🏭

Industrial Process Control Front End

The MAX181CCPL is a strong fit for industrial process-control front ends because it integrates 8 single-ended analog inputs, an internal track/hold, and an internal 5 V reference in a single PDIP-40 IC. With 12-bit resolution (4,096 codes) and 100 ksps throughput, the device easily digitizes thermocouple banks, RTD arrays, and 4-20 mA current-loop sensors after external signal conditioning. The parallel microprocessor interface maps directly to 8051, 68HC11, and similar legacy MCU buses, eliminating the need for an SPI peripheral in factory-automation cards. Compared to a discrete ADC-plus-mux-plus-reference design, the MAX181CCPL reduces board area by roughly 40% and removes the burden of matching analog stages. The 100 ksps rating is more than sufficient for process-control scan rates of 1 Hz to 1 kHz per channel after round-robin distribution.

📱

Multi-Channel Data Logger

Portable multi-channel data loggers benefit from the MAX181CCPL's single +5 V supply operation and 75 mW typical power dissipation, which simplify battery-powered and USB-powered designs. The 8 input channels can monitor a mix of slow-changing analog signals (temperature, voltage, current) by time-multiplexing through the on-chip analog mux. The 100 ksps burst rate allows the host microcontroller to sample all 8 channels in under 1 ms, then enter a low-power sleep state between scan intervals, dramatically extending battery life. The parallel interface is fast enough to keep pace with the ADC without inserting wait states on most MCUs. Engineers building SD-card or flash-based loggers often pair the MAX181CCPL with a small RISC MCU and a precision external reference for ratiometric measurements.

🔧

Instrumentation Front Panel

Bench instruments and rack-mounted test equipment often require a front-panel ADC subsystem that can digitize multiple transducer signals and present readings on a local display. The MAX181CCPL fits this role with 12-bit resolution sufficient for 3-1/2 digit panel meters (where 12 bits = 4096 counts, exceeding the 2000-count display range with margin). The 8 single-ended inputs can be configured for differential operation in pairs, supporting bridge-type transducers such as strain gauges and load cells. The on-chip reference simplifies calibration: designers use the internal 5 V reference for absolute measurements or override with an external MAX6350 for higher accuracy. The DIP-40 footprint also enables through-hole assembly for low-volume, hand-soldered prototypes used in R&D labs.

🖥️

Legacy Microprocessor-Based Factory Card

Industrial PCs and legacy PLCs based on 8-bit and 16-bit microprocessors (8051, 68HC11, Z80) often need a parallel-interface ADC card because the host lacks an SPI or I2C peripheral. The MAX181CCPL directly maps to these bus architectures with its 12-bit parallel data port, chip-select input, and read-strobe handshake. The 8 analog inputs allow a single IC to monitor up to 8 sensors per card slot, reducing slot count and BOM cost in PLC racks. The +5 V single supply operation aligns with the digital logic rail of legacy microprocessors, eliminating the need for level translation. Engineers maintaining installed-base equipment find the DIP-40 package particularly serviceable in the field because through-hole parts can be replaced without specialized rework stations.

📺

Portable Test Equipment

Handheld multimeters, field service testers, and battery-powered diagnostic equipment benefit from the MAX181CCPL's integrated 8-channel mux and parallel readback architecture. At 100 ksps burst rate, the device can digitize a transient event (such as a relay-contact bounce or a switched-mode power-supply startup surge) and stream the captured waveform to a host processor. The internal 5 V reference eliminates one external component, shrinking the BOM and reducing the chance of reference-related errors in field-deployed units. The commercial 0°C to +70°C range suits most indoor and mild outdoor environments; for harsher conditions, the MAX181CEPL extended-grade variant is preferred. The DIP-40 package also simplifies field-repair and reduces rework cost compared to fine-pitch QFN alternatives.

💊

Strain-Gauge / Bridge Transducer Reader

Strain gauges, load cells, and pressure transducers typically produce low-level differential signals that must be digitized with high resolution and adequate common-mode rejection. The MAX181CCPL can be configured for pseudo-differential operation by pairing its 8 single-ended inputs as 4 differential channels, doubling as a bridge transducer reader for 4 load cells per chip. The 12-bit resolution provides 4,096 counts, sufficient for 0.1% full-scale measurements when paired with low-noise instrumentation amplifiers on the front end. The on-chip reference supports ratiometric measurement when paired with an external excitation supply, eliminating absolute-accuracy errors. Engineers building weighing scales, force-test rigs, and pressure monitoring systems use the MAX181CCPL to balance cost (parallel-interface legacy support) against integration (no external mux or reference needed).

Recommended Products Summary

MAX1302 Higher-channel successor (14-channel, SPI) Used in: Industrial Process Control Front End MAX6341 External precision reference upgrade Used in: Industrial Process Control Front End MAX14701EWC+T Analog Devices Used in: Multi-Channel Data Logger MAX1280 Lower-power 12-bit SAR alternative for battery designs Used in: Multi-Channel Data Logger MAX6350 Precision 5 V external reference for calibration Used in: Instrumentation Front Panel MAX1300 Higher-integration 12-channel successor Used in: Instrumentation Front Panel MAX1306ECM+T Maxim Integrated Used in: Legacy Microprocessor-Based Factory Card MAX1156 12-bit parallel SAR with bipolar inputs Used in: Legacy Microprocessor-Based Factory Card MAX1157 16-channel 12-bit parallel SAR for higher density Used in: Portable Test Equipment MAX1062 Lower-power 14-bit SAR for battery designs Used in: Portable Test Equipment MAX1452 Strain-gauge signal conditioner companion Used in: Strain-Gauge / Bridge Transducer Reader MAX4238 Low-noise op-amp for bridge amplification Used in: Strain-Gauge / Bridge Transducer Reader
What is the resolution and channel count of MAX181CCPL?
The MAX181CCPL is a 12-bit, 8-channel data-acquisition system. According to the Maxim Integrated datasheet description, the device integrates a successive-approximation ADC, 8 analog input channels, a track/hold amplifier, and an internal reference. The 12-bit resolution provides 4,096 codes per conversion cycle, suitable for industrial process monitoring where moderate dynamic range is sufficient.
What is the maximum sampling rate of MAX181CCPL?
The MAX181CCPL performs up to 100,000 samples per second (100 ksps) on a single +5 V supply. The conversion time is dominated by the SAR settling and internal reference settling, typically ~8 µs to 10 µs. This throughput supports multi-channel scanning systems averaging 12.5 ksps per channel across all 8 inputs when round-robined.
What package does MAX181CCPL use?
The MAX181CCPL is offered in a 40-pin PDIP (Plastic DIP) through-hole package with 0.600 inch (15.24 mm) row spacing. The DIP-40 footprint is breadboard-friendly and supports legacy through-hole test fixtures. Designers targeting surface-mount assembly should consider the MAX181CCQP (PLCC-44) or MAX181CCWP (SOIC-28 wide) equivalents.
Where can I download the MAX181CCPL datasheet PDF?
The official MAX181CCPL datasheet is hosted at Maxim Integrated's datasheet archive at https://datasheets.maximintegrated.com/en/ds/MAX181-MAX181C.pdf. Third-party mirrors exist at alldatasheet.com, findic.us, and datasheets360.com. According to distributor listings, the document is 20 pages with file size ~732 KB.
Where can I buy MAX181CCPL and what is the price?
The MAX181CCPL is available through authorized distributors including Mouser, DigiKey (stock under the Analog Devices / Maxim Integrated franchise), Octopart, Vyrian, and Jotrin Electronics. As of 2026-10-15, distributor pricing starts around $9.95 in single-piece quantities and scales down to approximately $5.95 at 1,000-piece volume. Lead time varies; consult each distributor's inventory page for current stock.
What is the lead time and stock status of MAX181CCPL?
As of 2026-10-15, the MAX181CCPL lifecycle status is Not Recommended for New Designs (NRND), with limited distributor stock remaining. Authorized-channel inventory fluctuates between distributors, and lead times for production volumes are typically 8 to 12 weeks from factory or via remaining authorized inventory. Designers planning new designs should consider the MAX181CCPL+ variant or migrate to the MAX130x series.
MAX181CCPL vs MAX181BCPL - what is the difference?
The MAX181CCPL is the commercial-temperature grade (0°C to +70°C) variant of the MAX181 family, while the MAX181BCPL is the lower-spec 'B' grade. Both share the same PDIP-40 footprint and pinout, so they are drop-in compatible at the PCB level. According to the Maxim datasheet family, the 'C' grade typically offers improved linearity and the latest revision of the silicon; the 'B' grade may have wider linearity tolerance.
MAX181CCPL vs MAX181CEPL - which should I choose?
The MAX181CCPL and MAX181CEPL share the same 40-pin PDIP footprint and pinout, and both belong to the Maxim MAX181 DAS family. According to FindIC cross-reference data, they are complete replacements at the package and terminal level. The difference lies in the temperature grade: 'C' indicates 0°C to +70°C commercial, while 'E' indicates the -40°C to +85°C extended industrial range. Choose 'CEPL' for industrial temperature environments.
What is a drop-in replacement for MAX181CCPL?
The drop-in replacement for MAX181CCPL on the same 40-pin PDIP footprint is the MAX181CCPL+ variant (with RoHS compliance) or the MAX181CEPL+ (extended temperature grade). Cross-brand drop-in alternatives are limited because the MAX181's integrated track/hold + reference + 8-channel mux combination is rare; consult the DigiKey cross-reference tool at digikey.com/en/cross-reference for current parametric matches.
When should I choose MAX181CCPL over MAX130x series?
Choose the MAX181CCPL when you need a parallel-microprocessor-interface DAS with 8 single-ended channels, an internal reference, and a DIP package for through-hole prototyping. Migrate to the MAX130x series (MAX1302, MAX1300) when you need higher channel count (12 to 16 channels), true bipolar inputs without external scaling, SPI/QSPI interface, or surface-mount packaging. The MAX130x parts are newer and recommended for new designs.
What are the key specifications of MAX181CCPL that engineers should know?
The MAX181CCPL key specifications are: 12-bit resolution, 8 single-ended analog input channels, 100 ksps throughput, +5 V single supply, internal 5 V reference (externally overridable), successive-approximation architecture with internal track/hold, parallel data interface, commercial 0°C to +70°C operating range, and PDIP-40 through-hole package. Power dissipation is approximately 75 mW during continuous 100 ksps conversion.
Does MAX181CCPL require an external reference?
The MAX181CCPL includes an internal +5 V reference that is laser-trimmed at the factory for the SAR ADC core. For applications requiring higher absolute accuracy or ratiometric measurements, the internal reference can be overridden by driving the REF pin with an external precision reference (e.g., MAX6341 or MAX6350). According to the Maxim datasheet, the reference input range and bypass capacitor requirements are detailed in the electrical characteristics table.
Can MAX181AEPL replace MAX181CCPL?
The MAX181AEPL and MAX181CCPL share the same PDIP-40 footprint and pin assignment, making them pin-compatible on the PCB. Functionally, both are 12-bit, 8-channel, 100 ksps DAS devices with integrated reference. The 'A' grade is the initial-revision silicon and the 'C' grade is a later revision with improved linearity; the 'AEPL' suffix also extends to the -40°C to +85°C industrial temperature range, suitable when the 'C' commercial range is insufficient.
What is the difference between MAX181CCPL and MAX181CCPL+?
The MAX181CCPL and MAX181CCPL+ are functionally identical: 12-bit, 8-channel, 100 ksps DAS in PDIP-40. The '+' suffix on Maxim part numbers denotes lead-free (Pb-free) and RoHS-compliant terminal finish. According to Mouser's product listing, the MAX181CCPL+ is the RoHS-compliant version of the legacy MAX181CCPL. Both share the same datasheet and pinout; choose '+' for new designs requiring RoHS compliance.
Is MAX181CCPL suitable for industrial process control?
Yes, the MAX181CCPL is well suited for industrial process-control front ends because it integrates 8 single-ended input channels, an internal track/hold, an internal 5 V reference, and parallel-microprocessor interfacing in one chip. The commercial 0°C to +70°C temperature grade is acceptable for cabinet-mounted equipment, but for outdoor or factory-floor installations the MAX181CEPL (extended -40°C to +85°C) variant is recommended. The DIP-40 footprint supports easy field service and replacement.

Engineering reference data for MAX181CCPL — comparison, design guidance, and compliance information.

Selection Guide

Choose the MAX181CCPL when you need a complete 8-channel 12-bit data-acquisition system in a through-hole DIP-40 package for legacy microprocessor (8051/68HC11) interfacing, with internal reference and track/hold reducing external components. It is best suited for industrial process control, multi-channel data loggers, and instrumentation front panels where the commercial 0°C to +70°C temperature range is acceptable. For new designs, consider migrating to the MAX130x series (MAX1302, MAX1300) for higher channel count, true bipolar inputs, and SPI interface. Within the MAX181 family, choose the MAX181CCPL+ for RoHS compliance, the MAX181CEPL+ for extended -40°C to +85°C industrial temperature, and the MAX181BCPL/AEPL/ACPL only as drop-in replacements when specific silicon revisions are required. All five alternatives share the same PDIP-40 footprint, ensuring PCB compatibility.

Comparison with Alternatives

Parameter This Product MAX181CCPL+ MAX181CEPL+ MAX181BCPL+ MAX181AEPL+ MAX181ACPL+
Package PDIP-40 (through-hole) PDIP-40 - same PDIP-40 - same PDIP-40 - same PDIP-40 - same PDIP-40 - same
Brand Maxim Integrated Maxim Integrated Maxim Integrated Maxim Integrated Maxim Integrated Maxim Integrated
Resolution 12 bits 12 bits 12 bits 12 bits 12 bits 12 bits
Sampling Rate 100 ksps 100 ksps 100 ksps 100 ksps 100 ksps 100 ksps
Number of Channels 8 single-ended 8 single-ended 8 single-ended 8 single-ended 8 single-ended 8 single-ended
Operating Temperature 0°C to +70°C (Commercial) 0°C to +70°C (Commercial) -40°C to +85°C (Extended) 0°C to +70°C (Commercial) -40°C to +85°C (Extended) 0°C to +70°C (Commercial)
Interface Parallel (Word Access) Parallel (Word Access) Parallel (Word Access) Parallel (Word Access) Parallel (Word Access) Parallel (Word Access)
Supply Voltage +5 V single +5 V single +5 V single +5 V single +5 V single +5 V single
Lifecycle Status NRND Active (RoHS variant) Active NRND NRND NRND

Key Differentiators

  • Single-chip 8-channel DAS with integrated reference and track/hold (vs MAX181CCPL+ (RoHS variant))
  • Commercial temperature grade suited for indoor equipment (vs MAX181CEPL+ (extended -40C to +85C grade))
  • Parallel microprocessor interface for legacy MCU support (vs MAX1302 (SPI 12-channel successor))

Design Notes

The MAX181CCPL analog inputs can be damaged by overvoltage transients exceeding ±15 V; in industrial environments, add series resistors (typically 1 kΩ to 10 kΩ) and clamping diodes networks (e.g., BAV99 or TVS diodes to VDD/GND) on each analog input. Without protection, ESD events or nearby switching transients can permanently damage the input multiplexer. Also note that the device uses a successive-approximation architecture: the analog input must remain stable during the ~8 µs to 10 µs conversion window. If source impedance is high (>5 kΩ), buffer the input with an external op-amp to avoid conversion errors.

Bypass VDD with a 0.1 µF ceramic capacitor placed within 5 mm of the supply pin, in parallel with a 10 µF tantalum or aluminum electrolytic bulk capacitor. The internal +5 V reference also requires a 0.1 µF ceramic bypass on the REF pin to minimize reference-induced noise. The MAX181CCPL power dissipation is ~75 mW during 100 ksps conversion; for battery-powered designs, gate the conversion clock or use software-mode single-shot conversion to reduce average power. Estimated: total quiescent plus conversion current at +5 V is approximately 15 mA, yielding the ~75 mW figure.

Keep analog input traces short and routed away from digital lines (data bus, read/write strobes, clock) to minimize crosstalk. Use a single-point ground star topology with the AGND pin tied to a quiet analog ground island; the DGND pin connects to the digital ground plane. Place a ferrite bead or small inductor between analog and digital supplies if the +5 V rail is shared with noisy digital circuitry. The PDIP-40 footprint allows easy hand-wiring on prototype boards, but for production volume, consider migrating to the SO-28 or PLCC-44 surface-mount variants of the same MAX181 family.

Route the parallel data bus (D0-D11), chip select (CS), read (RD), and interrupt (INT) traces with matched lengths if the bus runs above 1 MHz to avoid timing skew. The MAX181CCPL parallel interface supports both 8-bit (two read cycles) and 16-bit (single read) data transfer; ensure the host processor firmware selects the correct mode by tying the BYTE/8BIT pin accordingly. Decouple the analog reference pin with both a 0.1 µF ceramic and a 10 µF electrolytic to maintain reference stability across temperature.

For multi-channel scanning, allow adequate acquisition time (typically 2 µs to 4 µs) after switching the analog mux before triggering a conversion. The internal track/hold has a finite acquisition aperture, and switching the mux too close to the conversion start can introduce channel-to-channel crosstalk. If scanning all 8 channels at the maximum 100 ksps aggregate rate, the per-channel throughput drops to 12.5 ksps, which is still ample for thermocouple and process-control scan rates.

Compliance Information

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Lead Free
No
Halogen Free
Unknown
Conflict Minerals
Unknown

RoHS and REACH compliance status not explicitly stated in verified web data for MAX181CCPL (non '+' variant). The MAX181CCPL+ is the lead-free RoHS-compliant variant per Mouser product listing. AEC-Q100 not applicable - this is a commercial/industrial-grade data acquisition IC, not automotive-grade.

Data verified on: 2026-10-15 — data verified and curated by XAIPART's component engineering team

Related Searches

MAX181CCPL MAX181CCPL datasheet Maxim Integrated MAX181CCPL 12-bit 8-channel ADC PDIP-40 100 ksps data acquisition system DIP MAX181CCPL industrial process control MAX181CCPL vs MAX181BCPL MAX181CCPL drop-in replacement MAX181CCPL buy price what is the resolution of MAX181CCPL MAX181CCPL pinout PDIP-40 legacy parallel ADC interface DAS

Related Components & Terms

Maxim Integrated MAX181CCPL MAX181CCPL+ MAX181CEPL+ MAX181BCPL+ MAX181AEPL+ MAX181ACPL+ data acquisition system DAS successive approximation ADC SAR 12-bit ADC analog-to-digital converter 8-channel multiplexer track and hold amplifier PDIP-40 Plastic DIP parallel interface word access internal reference RoHS process control industrial instrumentation
Quick Quote RFQ
Fill in complete details — our sales team will respond within 24 hours
Part Number Manufacturer Package QTY Target Price Extended
Total: $0.00 USD
✓
Quote submitted!

We will respond to your email within 24 hours

1
RFQ Submitted
2
Quote Received
3
Order Placed
4
Payment
5
Shipped
6
Delivered
View RFQ Details