MC1489ANE4 - Quad RS-232 Receiver, 4.5-5.5V | Texas Instruments
MPN: MC1489ANE4 ✓ ActiveMC1489ANE4 Overview
An RS-232 line receiver is an interface-circuit category that converts bipolar differential line-level signals into a single-ended logic-level output. The MC1489ANE4 belongs to the RS-232 receiver hierarchy, where it bridges data-terminal equipment and data-communications equipment. Its high-impedance inputs and wide input-signal tolerance are designed for receive-only ports that connect to a protected, physically distant communications cable.
Key features include four receiver channels in one package, operation across a 4.5 V to 5.5 V supply range, and compatibility with the TI A/EIA-232-F interface definition cited for the family. The monolithic low-power Schottky implementation allows a single package to serve four receive channels. The commercial-grade part is specified over 0°C to 70°C and is available in a through-hole PDIP-14 package for legacy industrial and communications equipment.
Each receiver converts its corresponding RS-232 input into a TTL-compatible output. A dedicated CONT terminal is provided for each channel, allowing the receiver behavior to be adjusted for particular system requirements. Unlike an RS-232 transceiver, this device contains no driver stages, so it must be paired with separate transmitters when a design requires bidirectional communication.
Typical uses include industrial RS-232 equipment, data-terminal interfaces, legacy printers and test instruments, point-of-sale systems, and embedded control panels that retain a through-hole communications interface. A four-channel receiver can reduce the component count when a system has four or fewer incoming serial ports, although unused channels still require appropriate input termination.
When laying out a board, route each receiver input directly to its connector and keep the sensitive input node away from high-current switching paths. Because this is a legacy PDIP-14 device, check the current manufacturer product page for availability and lifecycle status before starting a new volume production run.
This page combines package details, interface characteristics, cross-reference candidates, application guidance, and PCB design considerations to support component selection and legacy-product maintenance beyond the basic manufacturer datasheet.
Drop-in alternatives for MC1489ANE4 — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.
Variants in this series
Same-series models that are drop-in compatible with MC1489ANE4 (same form factor and footprint) — differing in Input Resistance, Interface Standard, Response Control, Input Hysteresis.
MC1489AN
✅ Drop-InContact for price
View Datasheet →DS14C89AN/NOPB
✅ Drop-In📋 Reference alternative (not in catalog)
SN75189AN
✅ Drop-In📋 Reference alternative (not in catalog)
MC1489N
✅ Drop-InContact for price
View Datasheet →MC1489N
✅ Drop-InContact for price
View Datasheet →MC1489ANE4 Specifications
| Product Type | Quadruple RS-232 line receiver |
| Number of Receiver Channels | 4 channels |
| Supply Voltage Range | 4.5 V to 5.5 V |
| Input Resistance | 3.0 kΩ to 7.0 kΩ |
| Input Signal Range | -30 V to +30 V |
| Interface Standard | TI A/EIA-232-F |
| Technology | Monolithic low-power Schottky |
| Response Control | One separate CONT terminal per receiver |
| Number of Pins | 14 pins |
| Package Type | PDIP-14 |
| Case Style | DIP-14 rectangular through-hole package |
| Mounting Type | Through-hole |
| Temperature Grade | Commercial |
| Operating Temperature | 0°C to 70°C |
| Transmitter Channels | 0 channels |
| Manufacturer Cross-Reference | Interchangeable with Motorola MC1489 |
MC1489ANE4 Pin Configuration
| Pin 1 | R1OUT — Receiver 1 output |
| Pin 2 | R1IN — Receiver 1 input |
| Pin 3 | R2OUT — Receiver 2 output |
| Pin 4 | R2IN — Receiver 2 input |
| Pin 5 | GND — Ground connection |
| Pin 6 | CONT3 — Receiver 3 response control |
| Pin 7 | R3IN — Receiver 3 input |
| Pin 8 | R3OUT — Receiver 3 output |
| Pin 9 | VCC — Positive supply connection |
| Pin 10 | CONT4 — Receiver 4 response control |
| Pin 11 | R4IN — Receiver 4 input |
| Pin 12 | R4OUT — Receiver 4 output |
| Pin 13 | CONT2 — Receiver 2 response control |
| Pin 14 | CONT1 — Receiver 1 response control |
Typical Applications
MC1489ANE4 is suitable for 6 applications: Legacy Industrial Controller RS-232 Input, Data-Terminal Equipment Interface, Legacy Printer and Test-Instrument Port, Point-of-Sale Terminal Communication, Four-Port Serial Data Concentrator, Laboratory and Service-Diagnostic Equipment.
Legacy Industrial Controller RS-232 Input
The MC1489ANE4 fits a legacy industrial controller that must receive as many as four RS-232 signals while retaining a 14-pin through-hole footprint. Its four independent receivers provide a single-ended logic output for each incoming line, and the 3.0 kΩ to 7.0 kΩ input resistance presents a light load to the communications cable. The 4.5 V to 5.5 V operating range suits a regulated 5 V control rail. Because the device includes receivers only, pair it with a separate transmitter when the controller also needs to transmit. Confirm the CONT-terminal connections and route the input traces away from switching nodes.
Recommended
Data-Terminal Equipment Interface
The MC1489ANE4 is suitable for the receive interface of data-terminal equipment designed around the TI A/EIA-232-F interface definition. Four channels in one PDIP-14 package reduce the number of discrete receiver packages and simplify multi-port equipment. Its input tolerance of -30 V to +30 V provides margin for protected RS-232 line levels, while the single-ended outputs connect directly to the system logic. Place protection components at the connector and provide a solid ground reference between the interface and logic sections. Verify the CONT pins in the manufacturer pin configuration before finalizing the schematic.
Recommended
Legacy Printer and Test-Instrument Port
A legacy printer controller or electronic test instrument can use the MC1489ANE4 to receive RS-232 status, measurement, or acknowledgment signals. The commercial 0°C to 70°C grade suits room-temperature indoor equipment, and the through-hole package remains convenient for serviceable industrial boards. Because a bidirectional printer link also requires an outbound driver, use the four MC1489ANE4 channels for inbound signals and add a separate RS-232 transmitter for transmitted commands. Route long cable-side nets through the protection network, and keep the receiver outputs away from the cable connector to minimize coupling into sensitive logic.
Recommended
Point-of-Sale Terminal Communication
Point-of-sale terminals often retain RS-232 ports for peripherals, scales, or service equipment even when newer models use USB. The MC1489ANE4 can consolidate four inbound serial lines into one package while operating from a 5 V-class supply. Its high input resistance of 3.0 kΩ to 7.0 kΩ helps limit loading of the connected equipment, and the -30 V to +30 V input range suits properly protected RS-232 signaling. Use separate protection and grounding provisions at the external connector because the IC is not a standalone surge protector. Confirm unused receiver inputs and CONT terminals against the manufacturer configuration table.
Recommended
Four-Port Serial Data Concentrator
The MC1489ANE4 can form the receive side of a compact four-port serial concentrator built around a common 5 V logic supply. Each receiver converts one remote RS-232 line into a logic-level signal for a controller or field-programmable logic. The four-channel integration reduces the footprint relative to four separate receiver packages, and the high input impedance is suitable for cable-connected sources. Separate transmit circuitry is needed for bidirectional concentrator ports, so evaluate the overall port count before committing to this architecture. Keep input traces short, provide connector-side protection, and use the manufacturer CONT guidance to avoid unused inputs floating.
Recommended
Laboratory and Service-Diagnostic Equipment
The MC1489ANE4 is appropriate for laboratory and service-diagnostic equipment that retains older RS-232 service ports alongside modern computer interfaces. Its 4.5 V to 5.5 V supply range operates from a standard 5 V rail, while four receivers support status and data inputs from several pieces of test gear. The through-hole PDIP-14 construction also simplifies repair and field replacement on older boards. Use ESD-rated protection and chassis-ground isolation techniques appropriate to the installation, because the device's ±30 V input tolerance is not a substitute for surge protection. Confirm the exact ordering code and temperature grade before a production buy.
Recommended
Recommended Products Summary
Engineering reference data for MC1489ANE4 — comparison, design guidance, and compliance information.
Selection Guide
Comparison with Alternatives
| Parameter | This Product | MC1489AN | DS14C89AN/NOPB | SN75189AN | MC1489 | MC1489 |
|---|---|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | STMicroelectronics | onsemi |
| Package | PDIP-14 | PDIP-14 - same | PDIP-14 - same | PDIP-14 - same | PDIP-14 - same | PDIP-14 - same |
| Receiver Channels | 4 | 4 | 4 | 4 | 4 | 4 |
| Transmitter Channels | 0 | 0 | 0 | 0 | 0 | 0 |
Key Differentiators
- Four independent RS-232 receivers in one through-hole package (vs MC1489AN)
- Wide protected-line input capability (vs DS14C89AN/NOPB)
- Receive-only architecture simplifies bidirectional-port planning (vs SN75189AN)
- Commercial-grade legacy interface with per-channel response control (vs MC1489)
Design Notes
Do not treat the MC1489ANE4 as a complete RS-232 port. It provides four receivers and zero transmitters, so every design that sends data also needs a separate RS-232 driver. Confirm the CONT-terminal state for every channel against the manufacturer pin-configuration table, especially when migrating an MC1489ANE4 board to DS14C89AN/NOPB or SN75189AN. These devices share the 14-pin through-hole format, but a common package outline does not by itself prove that every response-control connection is interchangeable.
Place the input protection network at the connector and route the protected receiver line directly to the corresponding MC1489ANE4 input pin. Keep switching-regulator traces, relay contacts, and high-current return paths away from the cable-side nets. The receiver input resistance is 3.0 kΩ to 7.0 kΩ, so the board's protection-network impedance will influence the effective termination. Use a low-impedance ground plane and connect the interface reference deliberately rather than relying on a long cable ground conductor alone.
Decouple the 4.5 V to 5.5 V supply at the device with a local ceramic bypass capacitor and connect the supply and ground pins using short traces. The MC1489ANE4 is a receive-only interface, so its supply current is generally modest, but cable transients and improper grounding can still inject energy into the receiver inputs. Do not rely on the stated -30 V to +30 V input tolerance as a substitute for surge or ESD protection. Validate the complete protection network against the actual cable length and grounding environment.
Compliance Information
The commercial 0°C to 70°C MC1489ANE4 is a legacy interface IC. Compliance declarations are not stated in the available product information and should be confirmed with the manufacturer for the exact ordering code.