TCAN1042HVDR - 2Mbps Fault-Protected CAN FD Transceiver | Texas Instruments
MPN: TCAN1042HVDR ✓ ActiveTCAN1042HVDR Overview
A CAN transceiver, also called a CAN physical-layer transceiver, converts logic-level TXD and RXD signals into differential CAN bus signals and converts received bus data back into a logic-level RXD output. It belongs to the interface IC hierarchy: CAN physical-layer transceiver, CAN bus interface, interface IC, and semiconductor. Fault-protected devices add internal mechanisms intended to limit the effects of electrical transients and abnormal bus conditions.
The TCAN1042HV family supports classic CAN and CAN FD communication up to 2 Mbps. According to the Texas Instruments TCAN1042HV datasheet, it meets ISO 11898-2:2016 and ISO 11898-5:2007 physical-layer standards. The transceiver also provides flexible data-rate operation, allowing a CAN FD controller to use higher payload rates while retaining compatibility with conventional CAN nodes. Its 4.5 V to 5.5 V operating range supports regulated 5 V systems, while the VIO interface supports integration with systems operating at different logic levels.
Internally, the transmitter drives the dominant and recessive states of the CANH and CANL conductors, while the receiver interprets differential bus voltage. A standby control allows the device to reduce activity when the bus is not required. Fault protection is particularly useful in industrial and automotive environments where cables, connectors, and external circuitry can expose the transceiver to electrostatic discharge or other bus transients. The short, symmetrical propagation-delay characteristics help preserve message timing across a network.
Typical uses include industrial automation controllers, automotive body and comfort modules, building-control gateways, robotics equipment, motor-control systems, and CAN FD gateways. The 8-pin SOIC package allows direct placement on conventional through-hole or mixed-technology assemblies. The TCAN1042HVDR ordering option is identified by Texas Instruments as an 8-pin SOIC (D) package, and the specified temperature range covers -55 °C to 125 °C.
When laying out the circuit, place the transceiver close to the CAN bus connector and its protection network. Keep the CANH and CANL traces short, route them as a differential pair, and provide a continuous return path. Decoupling capacitors should be positioned near the supply pins, and the ground connection should use a low-impedance path. The bus-side network and termination must be designed for the cable length and network topology rather than copied without considering propagation delay and termination.
This product overview combines the manufacturer device information, package details, operating limits, standard support, and engineering guidance for practical selection. It also organizes drop-in family alternatives and design considerations so engineers can evaluate the TCAN1042HVDR alongside closely related 8-pin transceivers before releasing a PCB design.
Drop-in alternatives for TCAN1042HVDR — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.
TCAN1042HGVDR
✅ Drop-In ⚠️ Specs Unverified📋 Reference alternative (not in catalog)
TCAN1042HDRQ1
✅ Drop-In📋 Reference alternative (not in catalog)
TCAN1042HVDRQ1
✅ Drop-In ⚠️ Specs Unverified📋 Reference alternative (not in catalog)
TCAN1042HVGDRQ1
✅ Drop-In ⚠️ Specs Unverified📋 Reference alternative (not in catalog)
TCAN1042HVD
✅ Drop-In📋 Reference alternative (not in catalog)
TCAN1042HVDR Specifications
| Product Type | Fault-protected CAN transceiver |
| Supported Protocol | Classic CAN and CAN FD |
| Maximum CAN FD Data Rate | 2 Mbps |
| Supply Voltage Range | 4.5 V to 5.5 V |
| Number of Bus Nodes | 1 CAN node |
| Physical-Layer Standard | ISO 11898-2:2016 |
| CAN FD Physical-Layer Standard | ISO 11898-5:2007 |
| Operating Temperature Range | -55 °C to 125 °C |
| Package | 8-pin SOIC (D) |
| Mounting Type | Surface mount |
| Bus Interface | Differential CANH and CANL |
TCAN1042HVDR Pin Configuration
| Pin 1 | VIO — Logic-side supply voltage input |
| Pin 2 | GND — Ground connection |
| Pin 3 | TXD — Transmit data input |
| Pin 4 | RXD — Receive data output |
| Pin 5 | VCC — CAN transceiver supply voltage input |
| Pin 6 | CANH — Differential CAN high bus terminal |
| Pin 7 | CANL — Differential CAN low bus terminal |
| Pin 8 | STB — Standby mode control input |
Typical Applications
TCAN1042HVDR is suitable for 6 applications: Industrial Automation Controller, Automotive Body Control Module, Robotics Motor Network, Building Control Gateway, CAN FD Diagnostic Interface, Industrial Sensor Network.
Industrial Automation Controller
The TCAN1042HVDR fits an industrial automation controller that communicates with sensors, drives, and remote I/O over a CAN bus. Its support for classic CAN and CAN FD at up to 2 Mbps allows the same physical layer to handle control traffic and higher-rate diagnostic or payload data. The 4.5 V to 5.5 V operating range suits regulated 5 V controller boards, while the -55 °C to 125 °C rating supports industrial temperature requirements. Place the transceiver near the field connector, route CANH and CANL as a differential pair, and use the manufacturer application circuit to select surge-protection and bus-filtering components.
Recommended
Automotive Body Control Module
The TCAN1042HVDR is suitable for a body-control module requiring a fault-protected physical layer for CAN communications among doors, lighting, climate controls, and seat electronics. CAN FD support up to 2 Mbps can increase the efficiency of gateway traffic compared with classic CAN while preserving compatibility with conventional nodes. Its -55 °C to 125 °C specification covers wide environmental conditions, although automotive production requires the appropriate qualified ordering option and separate verification of ESD, transient immunity, and bus-fault requirements. Keep external protection close to the connector and preserve a controlled ground path between the transceiver and connector.
Recommended
Robotics Motor Network
The TCAN1042HVDR can provide the physical layer for a distributed robot controller communicating with motor drivers and joint modules. A 2 Mbps CAN FD channel offers enough bandwidth for coordinated motion commands while retaining a robust differential bus architecture. The transceiver's fault-protected design is useful in industrial robots where motor systems can introduce electrical transients and long cable runs. Use short CANH and CANL branches, install suitable bus protection near exposed connectors, and calculate termination for the complete node count and cable topology. Validate propagation delay and node timing against the network length rather than relying only on the nominal 2 Mbps data rate.
Recommended
Building Control Gateway
The TCAN1042HVDR suits a building-control gateway that links HVAC units, lighting controllers, access equipment, and energy meters over a CAN backbone. Classic CAN support maintains interoperability with conventional building equipment, while CAN FD at up to 2 Mbps provides additional throughput for aggregated sensor or configuration data. The 4.5 V to 5.5 V supply range integrates naturally with a 5 V controller rail, and the broad -55 °C to 125 °C temperature specification supports industrial enclosure environments. Use surge protection at building entry points, maintain a low-impedance ground reference, and avoid long unprotected branches outside the enclosure.
Recommended
CAN FD Diagnostic Interface
The TCAN1042HVDR provides a physical layer for diagnostic interfaces that bridge a CAN FD-capable controller to a vehicle or industrial service network. Supporting both classic CAN and 2 Mbps CAN FD lets one transceiver interface participate in mixed networks where conventional diagnostic frames coexist with faster data traffic. The 8-pin SOIC package allows the interface to be placed close to a board connector and its protection network. During implementation, verify the controller's CAN FD mode, nominal bit timing, termination, loopback behavior, and bus-fault handling. A properly designed interface also needs isolation or common-mode components when the connected equipment has significant ground potential differences.
Recommended
Industrial Sensor Network
The TCAN1042HVDR can connect environmental, pressure, and machine-condition sensors that use CAN or CAN FD. Its 2 Mbps capability is useful when a controller combines frequent status updates with larger diagnostic payloads, while classic CAN compatibility permits mixed deployments. The 5 V supply range and compact 8-pin SOIC package simplify integration into compact sensor nodes. Keep the bus connection short for high data rates, use the termination appropriate for the selected branch, and ensure the transceiver ground shares a controlled reference with the controller. Where sensors connect through long external cables, add protection at the boundary rather than relying only on the transceiver's internal fault tolerance.
Recommended
Recommended Products Summary
Engineering reference data for TCAN1042HVDR — comparison, design guidance, and compliance information.
Selection Guide
Comparison with Alternatives
| Parameter | This Product | TCAN1042HGVDR | TCAN1042HDRQ1 | TCAN1042HVDRQ1 | TCAN1042HVGDRQ1 | TCAN1042HVD |
|---|---|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | 8-pin SOIC (D) | 8-pin SOIC (D) | 8-pin SOIC (D) | 8-pin SOIC (D) | 8-pin SOIC (D) | 8-pin SOIC (D) |
| Maximum CAN FD Data Rate | 2 Mbps | 2 Mbps | 2 Mbps | 2 Mbps | 2 Mbps | 2 Mbps |
| Supported Communication | Classic CAN and CAN FD | Classic CAN and CAN FD | Classic CAN and CAN FD | Classic CAN and CAN FD | Classic CAN and CAN FD | Classic CAN and CAN FD |
Key Differentiators
- Supports classic CAN and CAN FD in one physical-layer device (vs TCAN1042HGVDR)
- Broad specified operating-temperature range (vs TCAN1042HDRQ1)
- Fault-protected 2 Mbps CAN FD interface (vs TCAN1042HVD)
Design Notes
Place the TCAN1042HVDR near the CAN connector and place the bus protection network between the transceiver pins and the external CANH/CANL conductors. Route CANH and CANL together as a short differential pair, avoid crossing high-current switching paths, and provide a continuous ground reference beneath the pair when the board stackup and EMC strategy permit it. Keep the logic-side TXD and RXD traces away from the bus pins and protection components.
Decouple VCC and VIO locally with the capacitance specified by the manufacturer datasheet, using short ground-return paths to the device ground pins. Check the VIO supply against the controller's logic voltage because the TXD input threshold and RXD output characteristics depend on VIO. Validate the 4.5 V to 5.5 V operating range across temperature and supply tolerance, and ensure any external bus protection does not clamp normal dominant or recessive bus levels.
Do not assume that a shared SOIC-8 footprint guarantees drop-in compatibility. Confirm pin assignments, standby-input polarity, VIO range, propagation delay, receiver timeout behavior, bus-fault limits, and temperature grade for the exact alternative. CAN FD timing also depends on the complete controller, transceiver, cable, topology, and oscillator tolerance; validate the network at the intended bit rate and maximum cable length rather than relying on the nominal 2 Mbps rating alone.
Compliance Information
The general TCAN1042HVDR ordering option is not identified as an automotive-qualified part. RoHS, REACH, lead-free, halogen-free, and conflict-minerals declarations require confirmation from the manufacturer product page or declaration.