AD7946BCPZ - 14-Bit 500kSPS PulSAR ADC | Analog Devices
Артикул: AD7946BCPZ ✓ Активен| Кол-во | Цена за ед. | Итого |
|---|---|---|
| 1 | $13.26 | $13,26 |
| 10 | $12.5 | $125,00 |
| 100 | $11.2 | $1.120,00 |
| 500 | $10.1 | $5.050,00 |
| 1.000 | $9.5 | $9.500,00 |
AD7946BCPZ Обзор
An ADC (analog-to-digital converter) is an electronic component that converts continuous analog signals into discrete digital values, enabling digital processing of real-world signals. The AD7946 is a successive approximation register (SAR) ADC, which uses a charge redistribution architecture to achieve high accuracy and speed with low power consumption. SAR ADCs are widely used in applications requiring a balance of resolution, speed, and power efficiency, such as industrial process control, medical instrumentation, and portable devices.
Key features of the AD7946 include 14-bit resolution with no missing codes, integral nonlinearity (INL) of 0.4 LSB typical and 1 LSB maximum, and differential nonlinearity (DNL) of 0.25 LSB typical and 0.7 LSB maximum. The device operates over an industrial temperature range of -40°C to +85°C and features a pseudo-differential analog input with an input voltage range of -0.5 V to 5.8 V. The AD7946 also includes a 1-pole low-pass filter on the analog input, which helps to reduce noise from the driving amplifier.
The AD7946 uses a charge redistribution architecture with an internal sample-and-hold circuit, providing excellent AC and DC performance. The device supports multiple power-down modes, including Warp, Normal, and Impulse, allowing designers to optimize power consumption versus throughput. The SPI-compatible serial interface enables easy connection to microcontrollers and DSPs, and the device is fully specified for operation from a single 5 V supply.
Typical applications for the AD7946 include high-speed data acquisition, industrial process control, medical instrumentation, and portable battery-powered devices. Its low power consumption and small package make it ideal for portable and space-constrained applications, while its high accuracy and speed suit demanding industrial and medical systems.
When designing with the AD7946, ensure that the analog input is driven by a low-impedance source and that adequate decoupling is provided on the VDD pin. The device's noise performance is excellent, allowing the use of a noisier amplifier to meet system noise specifications, as the internal filter attenuates high-frequency noise.
Аналоги без доработки для AD7946BCPZ — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.
Варианты в этой серии
Модели той же серии, совместимые без доработки с AD7946BCPZ (тот же форм-фактор и посадочное место) — отличается по Architecture, Package, Input Type, Resolution, Operating Temperature.
Инструмент быстрого сравнения — выберите альтернативные компоненты для сравнения бок о бок:
AD7946BCP
✅ Прямая замена📋 Справочный аналог (нет в каталоге)
AD7946BCPZ Максимальные параметры и электрические характеристики
| Разрешение | 14-bit |
| Sample Rate (Warp mode) | 500 kSPS |
| Sample Rate (Normal mode) | 450 kSPS |
| Sample Rate (Impulse mode) | 380 kSPS |
| INL | 0.4 LSB typ, 1 LSB max |
| DNL | 0.25 LSB typ, 0.7 LSB max |
| Диапазон входного напряжения | -0.5 V to 5.8 V |
| Напряжение питания | 5 V |
| Рабочая температура | -40°C to +85°C |
| Корпус | 10-lead LFCSP (3 mm x 3 mm) |
| Тип монтажа | Surface Mount |
| Количество выводов | 10 |
| Architecture | SAR (charge redistribution) |
| Input Type | Pseudo-differential |
| Интерфейс | SPI-compatible |
Конфигурация выводов AD7946BCPZ
| Контакт 1 | VDD — Power supply, 5V |
| Контакт 2 | GND — Ground |
| Контакт 3 | IN+ — Positive analog input |
| Контакт 4 | IN- — Negative analog input |
| Контакт 5 | REF — Reference input |
| Контакт 6 | SCK — Serial clock input |
| Контакт 7 | SDI — Serial data input |
| Контакт 8 | SDO — Serial data output |
| Контакт 9 | CNV — Convert input |
| Контакт 10 | GND — Ground |
Типичное применение
AD7946BCPZ подходит для 6 применениеs: High-Speed Data Acquisition, Industrial Process Control, Medical Instrumentation, Portable Battery-Powered Devices, Test and Measurement Equipment, Communication Systems.
High-Speed Data Acquisition
The AD7946BCPZ's 500 kSPS sample rate and 14-bit resolution make it ideal for high-speed data acquisition systems. Its low power consumption and small package enable compact designs. The SPI interface simplifies connection to microcontrollers, and the pseudo-differential input reduces common-mode noise, ensuring accurate signal capture in industrial and test equipment.
Рекомендуется
Industrial Process Control
In industrial process control, the AD7946BCPZ provides accurate, high-speed conversion of sensor signals. Its 14-bit resolution and low INL ensure precise monitoring of temperature, pressure, and flow. The device operates over -40°C to +85°C, suitable for harsh environments. The SPI interface allows easy integration with PLCs and industrial microcontrollers, and the small LFCSP package saves board space.
Рекомендуется
Medical Instrumentation
The AD7946BCPZ is well-suited for medical instrumentation such as patient monitoring and diagnostic equipment. Its low power consumption extends battery life in portable devices, while the 14-bit resolution provides accurate readings. The small package enables miniaturization of medical devices. The device's low noise performance allows the use of simpler front-end amplifiers, reducing system cost and complexity.
Рекомендуется
Portable Battery-Powered Devices
For portable devices, the AD7946BCPZ offers multiple power-down modes (Warp, Normal, Impulse) to optimize power consumption. Its low power dissipation extends battery life, and the 3x3 mm LFCSP package is ideal for compact designs. The SPI interface is compatible with low-power microcontrollers, and the device operates from a single 5 V supply, simplifying power management.
Рекомендуется
Test and Measurement Equipment
The AD7946BCPZ is used in test and measurement equipment such as digital multimeters and data loggers. Its high sample rate and 14-bit resolution enable accurate waveform capture. The device's low INL and DNL ensure linearity, and the SPI interface allows fast data transfer to processors. The small package and industrial temperature range make it suitable for benchtop and portable instruments.
Рекомендуется
Communication Systems
In communication systems, the AD7946BCPZ can be used for baseband signal digitization in software-defined radios and receivers. Its 500 kSPS sample rate is sufficient for narrowband signals, and the 14-bit resolution provides good dynamic range. The device's low power consumption is beneficial for portable communication devices. The SPI interface enables easy integration with DSPs and FPGAs.
Рекомендуется
Сводка рекомендуемых товаров
Справочные инженерные данные для AD7946BCPZ — сравнение, рекомендации по проектированию и информация о соответствии.
Руководство по выбору
Сравнение с аналогами
| Параметр | Этот товар | AD7946BRMZ | AD7946BCP | ADS7946 |
|---|---|---|---|---|
| Package | 10-lead LFCSP (3x3 mm) | 10-lead MSOP | 10-lead LFCSP (3x3 mm) | 10-lead MSOP |
| Brand | Analog Devices | Analog Devices | Analog Devices | Texas Instruments |
| Resolution | 14-bit | 14-bit | 14-bit | 14-bit |
| Sample Rate | 500 kSPS | 500 kSPS | 500 kSPS | 2 MSPS |
| Input Voltage Range | -0.5 V to 5.8 V | -0.5 V to 5.8 V | -0.5 V to 5.8 V | 0 V to 5 V |
| Supply Voltage | 5 V | 5 V | 5 V | 2.7 V to 5.5 V |
| INL | 0.4 LSB typ | 0.4 LSB typ | 0.4 LSB typ | 1 LSB max |
| Interface | SPI | SPI | SPI | SPI |
Ключевые отличия
- Higher sample rate than AD7942 (против AD7942BRMZ)
- Smaller package than AD7946BRMZ (против AD7946BRMZ)
- Lower power consumption than ADS7946 (против ADS7946)
Заметки по проектированию
Decouple the VDD pin with a 10 µF and 0.1 µF capacitor placed as close as possible to the pin. The AD7946 operates from a single 5 V supply; ensure the supply is clean and stable to maintain ADC accuracy. Refer to the datasheet's power supply recommendations.
For optimal performance, use a solid ground plane and minimize trace lengths on the analog input. The pseudo-differential input should be routed with care to avoid noise pickup. Place the ADC close to the signal source to reduce parasitic capacitance.
Avoid driving the analog input beyond the specified -0.5 V to 5.8 V range, as this can damage the device. Use an external buffer amplifier if the source impedance is high. Also, ensure the reference input is properly decoupled to avoid reference noise affecting conversion accuracy.
Информация о соответствии
RoHS compliant per ADI product page. Not AEC-Q100 qualified.