Analog Devices

AD7710AN - 24-Bit Dual-Input Sigma-Delta ADC | Analog Devices

MPN: AD7710AN ✓ نشط
1 integrated current source Id 24-PDIP Package
الحد الأدنى للطلب: 1 |

AD7710AN نظرة عامة

Analog Devices AD7710AN is a 24-bit, dual-input, single-channel sigma-delta analog-to-digital converter designed for low-level measurement systems. It accepts differential signals directly from strain gauges, transducers, and other slow-varying sensors, while providing digital output through a serial interface. The device is available in a 24-pin plastic dual inline package designated 24-PDIP and is specified for operation from -40°C to +85°C.

A sigma-delta ADC is a voltage-regulating measurement category that uses oversampling and digital filtering to achieve high resolution in low-bandwidth applications. Within the hierarchy of data-conversion components, the AD7710AN belongs to the analog-to-digital converter class, combining a low-noise analog front end with a digital noise-shaping conversion stage. This architecture is intended to resolve small differential inputs without requiring a high-speed flash or successive-approximation converter.

The AD7710AN provides up to 24-bit resolution, two differential analog inputs, and a differential reference input. One channel normally serves as the main measurement input while the second can be used as an auxiliary channel for periodic measurements. Its integrated signal-conditioning and conversion functions reduce the external circuitry required for strain-gage bridges and other low-frequency instrumentation. The manufacturer identifies the device as a production CMOS signal-conditioning ADC with an integrated current source.

The dual-channel architecture supports single-channel and dual-channel measurement arrangements. Differential input operation helps reject common-mode voltage, while the auxiliary channel can monitor another sensor or establish channel-specific correction information. Because the converter targets low-frequency signals rather than waveform capture, its strengths are resolution, input flexibility, and direct transducer interfacing rather than high conversion throughput.

Typical applications include strain-gage and load-cell measurement, pressure and force sensing, industrial process monitoring, laboratory instrumentation, and low-level bridge excitation. The differential reference input supports externally defined reference voltage, while the current source supports suitable resistive sensor networks. Designers should still account for input bandwidth, settling time, digital filter selection, reference accuracy, and sensor excitation requirements when defining measurement performance.

For implementation, follow the analog-device pin-description table in the manufacturer datasheet for every connection and supply decoupling requirement. Keep reference and sensor traces short, isolate them from switching-node currents, use a stable reference source, and include filtering appropriate to the selected digital notch frequency. These practices are especially important because sensor-level signals are often small enough for layout noise or reference drift to affect the final measurement.

This product page combines the AD7710AN package and converter characteristics with sourcing guidance, comparison criteria, and practical sensor-conditioning design notes. It also identifies manufacturer documentation, real product-search links, and the most relevant option for locating pin assignments, electrical limits, and application guidance before PCB implementation.

بدائل مباشرة لـ AD7710AN — نفس الحزمة، متوافق دبوس بدبوس. تُستثنى القطع ذات الحزم المختلفة التي تتطلب تعديل PCB.

AD7710AQ

✅ بديل مباشر
Analog Devices
📦 24-PDIP
24 bit · 2 analog inputs · 1 Sigma-Delta · Sigma-delta analog-to-digital converter · Integrated programmable-gain analog front end for low-level transducer signals

تواصل لمعرفة السعر

عرض ورقة البيانات ←

AD7710ANZ

✅ بديل مباشر
📦 24-PDIP
Lead-free ordering suffix; converter resolution remains 24 bits and channel count remains 2, a 0% change in those key parameters

📋 بديل مرجعي (غير موجود في الكتالوج)

AD7710BN

✅ بديل مباشر ⚠️ مواصفات غير مُتحقق منها
📦 24-PDIP
Standard-family plastic-DIP ordering suffix; converter resolution remains 24 bits and channel count remains 2, a 0% change in those key parameters

📋 بديل مرجعي (غير موجود في الكتالوج)

AD7710BNZ

✅ بديل مباشر ⚠️ مواصفات غير مُتحقق منها
📦 24-PDIP
Lead-free plastic-DIP ordering suffix; converter resolution remains 24 bits and channel count remains 2, a 0% change in those key parameters

📋 بديل مرجعي (غير موجود في الكتالوج)

AD7710BQ

✅ بديل مباشر ⚠️ مواصفات غير مُتحقق منها
📦 24-PDIP
Ceramic-DIP family ordering suffix; converter resolution remains 24 bits and channel count remains 2, a 0% change in those key parameters

📋 بديل مرجعي (غير موجود في الكتالوج)

AD7710AN الحدود القصوى والخصائص الكهربائية

الدقة 24 bits
Analog Input Count 2 inputs
Input Configuration 2 differential analog inputs
Reference Input 1 differential reference input
Conversion Architecture 1 sigma-delta converter
Resolution Method Sigma-delta conversion with up to 24 bits of no missing codes
العلبة 24-PDIP
Package Pin Count 24 pins
Package Style In-line DIP
Package Height 5.33 mm
درجة حرارة التشغيل -40°C to +85°C
Process Technology Production CMOS
Signal Conditioning Integrated analog front end for low-frequency measurement
Transducer Support Direct low-level signal acquisition from strain gauges and transducers
Current Source 1 integrated current source
Digital Output 1 serial digital word output

دليل تكوين أطراف AD7710AN 5.33 mm

تكوين الأطراف لـ AD7710AN (حزمة 5.33 mm). يتميز هذا المكوّن التناظري بأطراف الإدخال والإخراج وإمداد الطاقة. راجع ورقة بيانات الشركة المصنعة لتكوينات طرف إلغاء الإزاحة والتعويض والتمكين. مثالي لدوائر تكييف الإشارة والمضخمات.

مخطط توزيع أطراف حزمة 5.33 mm لـ AD7710AN

لا تتوفر بيانات مفصلة لمخطط التوصيلات لـ AD7710AN.

راجع ورقة البيانات للحصول على تكوين الأطراف الكامل.

التطبيقات النموذجية

AD7710AN مناسب لـ 6 التطبيقs: Strain-Gage Load-Cell Measurement, Industrial Pressure and Force Sensing, Laboratory Instrumentation, Precision Temperature Monitoring, Process-Control Instrumentation, Portable Sensor and Test Equipment.

🏭

Strain-Gage Load-Cell Measurement

The AD7710AN is well suited to low-frequency bridge measurements because its 24-bit resolution preserves small differential changes produced by strain gauges. The integrated analog front end and current source reduce the amount of external signal-conditioning hardware required around the sensor. In a typical load-cell circuit, the transducer output is applied differentially while the reference channel establishes the conversion scale. Designers should still include input protection, shield or guard strategies for long cable runs, and calibration for offset and gain. The converter’s low-frequency focus makes it more appropriate for static force and weight measurements than for rapidly changing mechanical waveforms.

🏭

Industrial Pressure and Force Sensing

Industrial pressure transmitters and force sensors frequently produce small differential signals that require high resolution and careful reference control. The AD7710AN provides a 24-bit conversion result, two differential input channels, and an integrated current source suitable for compatible resistive sensor networks. One input can serve as the primary measurement channel while the auxiliary input supports a second sensor or periodic correction measurement. Its analog front end simplifies the signal chain, but practical accuracy depends on bridge resistance matching, reference stability, input settling, and digital-filter selection. Use short guarded traces and separate sensitive returns from switching or relay currents to preserve sensor-level signal integrity.

🔧

Laboratory Instrumentation

The AD7710AN can serve as the measurement core in laboratory instruments that acquire slow, high-resolution sensor data rather than waveforms. Its 24-bit resolution supports precise reading of strain, temperature, and resistance-based probes when the front end and reference are designed appropriately. The serial digital output is suitable for a microcontroller or instrument controller, while the second differential input adds measurement flexibility. Because the converter requires finite settling time after each conversion, firmware must synchronize measurements with the selected digital filter and output rate. Reference drift, offset calibration, and sensor self-heating should be included in the instrument’s uncertainty budget.

💊

Precision Temperature Monitoring

Low-amplitude resistive or differential temperature sensors can benefit from the AD7710AN’s 24-bit resolution when the measurement requires more resolution than a conventional general-purpose ADC. The integrated front end reduces analog signal-conditioning complexity, and the differential reference supports common-mode rejection when the sensor and reference arrangement are carefully balanced. The auxiliary input can monitor a second sensor when temperature compensation or redundancy is needed. Engineers should evaluate sensor excitation drift, self-heating, reference accuracy, and conversion latency rather than treating nominal resolution as total measurement accuracy. A stable low-noise reference and an appropriate input network are particularly important for detecting small temperature changes.

🖥️

Process-Control Instrumentation

The AD7710AN is appropriate for slow process variables such as force, pressure, level, or bridge-based flow measurements where high resolution is more valuable than rapid sampling. Two differential inputs allow the controller to alternate between a primary process sensor and an auxiliary measurement, supporting periodic diagnostics or reference tracking. The sigma-delta front end performs filtering and conversion within one device, allowing a compact analog section before the digital controller. Commissioning should include zero and full-scale calibration, verification of input settling, and testing against the required update interval. Care must be taken to isolate the front end from relays, motor drives, and other high-energy switching sources.

📱

Portable Sensor and Test Equipment

Battery-operated measurement instruments can use the AD7710AN to obtain high-resolution readings from low-level sensors while retaining a straightforward 24-pin through-hole package for serviceable or prototype hardware. The converter’s multi-stage analog conditioning avoids many discrete amplification and filtering stages, helping reduce board complexity. Portable designs still require careful power planning because the supply and reference circuitry contribute to total system error and energy use. Choose capacitors and reference components according to the manufacturer’s guidance, minimize leakage around high-impedance sensor inputs, and define whether each reading must be settled, averaged, or digitally filtered. The serial interface supports compact embedded control.

What is the AD7710AN?
The AD7710AN is a 24-bit, dual-input sigma-delta analog-to-digital converter from Analog Devices for low-frequency measurement applications. It combines an analog front end, programmable gain, digital conversion, and filtering in a 24-PDIP package. According to the Analog Devices AD7710 datasheet, it accepts low-level differential signals directly from strain gauges and transducers and produces a serial digital result.
What are the key specifications of AD7710AN that engineers should know?
The AD7710AN provides 24-bit resolution, two differential analog inputs, one differential reference input, and one sigma-delta conversion channel in a 24-PDIP package. Its specified operating range is -40°C to +85°C. Analog Devices describes it as a production CMOS signal-conditioning ADC with an integrated current source for low-level transducer measurement.
Where can I download the AD7710AN datasheet PDF?
The official AD7710AN datasheet PDF is available from Analog Devices at the AD7710 product-page download link. The manufacturer document is titled AD7710 Data Sheet and is identified as Revision G in the product-page result. Use the pin-description and electrical-characteristics tables there when assigning connections, setting the reference, and checking operating limits.
Where can I find the AD7710AN pinout?
The AD7710AN pinout is documented in the AD7710 manufacturer datasheet and must be assigned from the package drawing and pin-description table rather than inferred from another package. The AD7710AN uses a 24-PDIP package with 24 terminals. Confirm analog inputs, reference terminals, digital interface signals, supply pins, and the exposed package details against the exact AD7710AN ordering table.
What is the difference between AD7710AN and AD7710AQ?
AD7710AN is the 24-PDIP industrial-temperature ordering option, specified from -40°C to +85°C, while AD7710AQ is the ceramic-DIP temperature-grade option associated with the same AD7710 converter family. The AD7710AQ comparison result identifies both devices as 24-bit sigma-delta signal-conditioning ADCs. Verify mechanical details and temperature coverage in the Analog Devices ordering table before substitution.
Is AD7710AN the same as AD7710ANZ?
AD7710AN and AD7710ANZ implement the same AD7710 signal-conditioning ADC family, but the Z ordering suffix identifies a different terminal-finish or environmental ordering variant. A comparison result confirms that the AD7710ANZ retains the 24-bit converter, analog front end, and low-frequency measurement architecture. Confirm package, temperature range, and production requirements before treating the suffixes as interchangeable.
What can replace AD7710AN?
The closest verified same-family replacement candidates are AD7710AQ and AD7710ANZ because they retain the AD7710 converter architecture and 24-PDIP mechanical format. AD7710BN, AD7710BNZ, and AD7710BQ are additional same-family ordering options based on the device naming convention. No cross-brand drop-in replacement was established, so validate pinout, temperature grade, calibration behavior, and supply requirements before substitution.
What is the best Analog Devices equivalent for AD7710AN?
AD7710BN is the closest same-brand plastic-DIP option to AD7710AN for designs requiring the standard AD7710 architecture without changing the PCB footprint. The principal decision is the ordering suffix and its associated qualification or environmental profile. Because converter and electrical parameters remain family-defined, compare the official ordering table for temperature range, terminal finish, and production status.
Where can I buy AD7710AN online?
Use the Request a Quote form on this page to request AD7710AN pricing, availability, and lead time from XAIPART. The AD7710AN is listed as a 24-bit, two-input sigma-delta ADC in a 24-PDIP package, and the official manufacturer product page confirms the active AD7710 family. Submit the exact suffix AD7710AN with your required quantity and delivery location.
What is the price of AD7710AN?
Current AD7710AN pricing is handled through the Request a Quote form on this page rather than a static price table. The official Analog Devices product page lists a starting list price for the AD7710 family, but the quote form provides the appropriate response for the exact AD7710AN suffix, quantity, delivery location, and current availability. Use the form for a current purchasing response.
What is the lead time for AD7710AN?
Current AD7710AN lead time should be requested through the Request a Quote form on this page. The manufacturer lists the AD7710 as a production CMOS product, but production status does not by itself specify the available quantity or lead time for a particular order. Include your required quantity, date code preference, and destination in the request for an actionable commitment.
Is AD7710AN in stock?
Use the Request a Quote form on this page to confirm current AD7710AN stock and expected fulfillment timing. The product-page result identifies AD7710AN as a 24-bit, two-input, one-channel sigma-delta ADC in a 24-PDIP package, while the Analog Devices page identifies the AD7710 family as production CMOS. A quote response should confirm quantity, date code, and dispatch timing.
When should I choose AD7710AN over another 24-bit ADC?
Choose AD7710AN when the design needs high-resolution conversion of low-frequency differential signals from strain gauges or similar transducers. Its 24-bit resolution, integrated analog front end, differential reference input, and current source simplify measurement-chain design. Select another converter when the application requires substantially higher conversion speed, a smaller package, or a different digital interface.
Is AD7710AN suitable for strain-gauge and pressure-sensor measurements?
The AD7710AN is suitable for strain-gauge, load-cell, and related low-level bridge measurements because its analog front end accepts differential transducer signals and includes a current source. Its sigma-delta architecture is optimized for low-frequency measurement rather than high-speed sampling. System accuracy still depends on bridge excitation, reference stability, analog filtering, and mechanical offset correction.
What design considerations apply when using AD7710AN?
Use a stable reference, protect sensor inputs from switching-node noise, and route reference and analog traces away from digital return currents. The sigma-delta converter’s digital filter and conversion rate must match the required settling time. Because low-level transducer signals are sensitive to thermal gradients and parasitic resistance, follow the application-circuit guidance and grounding practices in the manufacturer datasheet.

بيانات مرجعية هندسية لـ AD7710AN — المقارنة وإرشادات التصميم ومعلومات الامتثال.

دليل الاختيار

Choose AD7710AN for slow, high-resolution measurement of strain-gage, load-cell, pressure, force, or similar differential signals when the design requires the standard 24-PDIP option specified for -40°C to +85°C. Its integrated analog front end, current source, differential reference, and serial output simplify a compact measurement channel. Select AD7710AQ when the application requires the family’s ceramic-DIP temperature grade, or AD7710ANZ when a lead-free ordering suffix is preferred. AD7710BN, AD7710BNZ, and AD7710BQ provide additional same-family ordering choices, but their environmental and qualification requirements must be checked against the production ordering table. Do not select this converter family for high-bandwidth waveform acquisition; choose a faster ADC when conversion latency or sample rate is the dominant requirement.

المقارنة مع البدائل

المعامل هذا المنتج AD7710AQ AD7710ANZ AD7710BN AD7710BNZ AD7710BQ
Package 24-PDIP 24-PDIP 24-PDIP 24-PDIP 24-PDIP 24-PDIP
Brand Analog Devices Analog Devices Analog Devices Analog Devices Analog Devices Analog Devices
Resolution 24 bits 24 bits 24 bits 24 bits 24 bits 24 bits
Analog Input Count 2 inputs 2 inputs 2 inputs 2 inputs 2 inputs 2 inputs
Reference Input Differential reference input Differential reference input Differential reference input Differential reference input Differential reference input Differential reference input
Conversion Architecture 1 sigma-delta channel 1 sigma-delta channel 1 sigma-delta channel 1 sigma-delta channel 1 sigma-delta channel 1 sigma-delta channel
Integrated Current Source Present Present Present Present Present Present
Digital Interface Serial output Serial output Serial output Serial output Serial output Serial output

أبرز الفروقات

  • Direct low-level transducer measurement (مقابلAD7710BN)
  • Temperature-graded family options (مقابلAD7710AQ)
  • Lead-free family ordering (مقابلAD7710ANZ)

ملاحظات التصميم

Route the differential sensor and reference connections as short, closely coupled traces with a continuous ground reference. Keep these nets away from switching-node copper, relay contacts, high-current returns, and digital clock signals. For long sensor cables, use guarded or shielded wiring and connect the shield according to the sensor and grounding strategy recommended for the installation. A grounded guard can reduce leakage and common-mode pickup, but incorrect chassis grounding may introduce a new error path.

Use the manufacturer’s specified supply and reference arrangements to prevent noise or instability from reducing measurement resolution. Place decoupling capacitors close to their associated pins and use a low-noise reference source when measuring small signals. Verify reference start-up, allowable input range, and digital-interface levels during power sequencing. If analog and digital supplies originate from different sources, confirm their relationship during startup to avoid forward-biased device inputs.

Do not select the digital filter solely to maximize resolution. Its notch frequency and settling time determine the usable output rate, and an overly narrow filter may slow the measurement loop beyond the application requirement. Conversely, excessive bandwidth admits noise that the nominal 24-bit resolution cannot recover. Establish the required update interval first, then select filtering and gain settings that provide adequate settling while preserving the intended measurement bandwidth.

Perform offset and gain calibration after the complete analog input network is connected. Thermal gradients, reference drift, sensor lead resistance, and the auxiliary-channel measurement can affect the final result. Use repeated zero readings to identify drift and avoid interpreting missing digital codes as meaningful sensor resolution. Document calibration temperature, gain setting, filter selection, and settling time so that software corrections match the hardware operating condition.

معلومات الامتثال

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
خالٍ من الرصاص
Unknown
خالٍ من الهالوجين
Unknown
المعادن المتنازع عليها
Unknown

Compliance status must be confirmed for the exact ordering suffix using the manufacturer’s current product and material documentation.

تم التحقق من البيانات في: 2026-11-22 — تم التحقق من البيانات وتنسيقها بواسطة فريق هندسة المكونات في XAIPART

عمليات بحث ذات صلة

ad7710 pinout ad7710 datasheet AD7710AN datasheet PDF AD7710AN pinout AD7710AN 24-PDIP pinout AD7710AN strain gauge ADC AD7710AN pressure sensor AD7710AN vs AD7710AQ AD7710AN equivalent AD7710AN replacement AD7710AN price AD7710AN stock

المكونات والمصطلحات ذات الصلة

Analog Devices AD7710AN AD7710 AD7710AQ AD7710ANZ AD7710BN AD7710BNZ AD7710BQ sigma-delta ADC analog-to-digital converter signal-conditioning ADC low-frequency measurement strain gauge load cell pressure sensor force sensor differential input differential reference input integrated current source 24-bit resolution 24-PDIP DIP package through-hole package serial digital output production CMOS
عرض سعر سريع RFQ
املأ التفاصيل الكاملة — سيرد فريق المبيعات لدينا خلال 24 ساعة
رقم القطعة الشركة المصنعة الحزمة QTY السعر المستهدف الإجمالي
✓
تم إرسال عرض السعر!

سنرد على بريدك الإلكتروني خلال 24 ساعة

1
تم إرسال طلب عرض السعر
2
تم استلام عرض السعر
3
تم تقديم الطلب
4
الدفع
5
تم الشحن
6
تم التسليم
عرض تفاصيل طلب عرض السعر