Texas Instruments

ADS1230IPW - 20-Bit, 80 SPS Bridge ADC | Texas Instruments

MPN: ADS1230IPW ✓ نشط
5 V Vdss 16-pin TSSOP (PW) Package
الحد الأدنى للطلب: 1 |

ADS1230IPW نظرة عامة

Texas Instruments ADS1230IPW is a 20-bit, single-channel delta-sigma analog-to-digital converter optimized for resistive bridge sensors, with a maximum conversion rate of 80 samples per second in a 16-pin TSSOP package. It integrates a low-noise programmable gain amplifier, an onboard oscillator, and a precision 20-bit conversion stage.

A delta-sigma ADC is a class of analog-to-digital converter that uses continuous-time sampling, noise shaping, and digital filtering to provide high resolution and excellent rejection of out-of-band noise. In the signal-chain hierarchy, the ADS1230 belongs to the ADC/DAC category and integrates functions commonly implemented separately around a precision converter, including a low-noise PGA, internal clock source, and bridge-sensor front end.

The converter provides programmable gains of 1, 2, 64, and 128, allowing small differential bridge outputs to be amplified before digitization. Its 20-bit conversion resolution, 80 SPS maximum data rate, and 5 V supply operation make it suitable for precision measurement systems rather than high-speed waveform acquisition. A stated linearity error of 0.001% supports accurate measurement in weigh scales, strain-gauge systems, and pressure sensors.

Because the ADS1230 uses a delta-sigma architecture, resolution and conversion speed are intentionally traded against one another. The integrated PGA reduces the number of external analog amplification stages required, while the onboard oscillator removes the need for an external clock in many bridge-sensor designs. The result is a compact analog measurement front end with fewer external components and less opportunity for low-level signal-chain errors.

Typical uses include industrial weighing platforms, force and load measurement, resistive pressure transducers, strain-gauge conditioning, and laboratory instrumentation. In these applications, the differential input architecture suits a Wheatstone bridge, while programmable gain accommodates changes in excitation level and sensor sensitivity. Systems requiring hundreds or thousands of conversions per second should select a faster delta-sigma or SAR converter instead.

PCB design should keep the bridge inputs, reference connection, and ground return paths compact and away from switching nodes. Use a low-noise reference source and appropriate input filtering, and observe the datasheet recommendations for bypass capacitance and exposed analog grounding. The external reference and excitation arrangement directly influence the absolute accuracy of the complete measurement chain.

This page combines manufacturer specifications, pin and package guidance, application-focused engineering notes, and a parameter comparison intended to simplify ADS1230IPW selection. It also distinguishes exact drop-in opportunities from devices that share a package but require different firmware, sampling rates, interfaces, or analog front-end configurations.

بدائل مباشرة لـ ADS1230IPW — نفس الحزمة، متوافق دبوس بدبوس. تُستثنى القطع ذات الحزم المختلفة التي تتطلب تعديل PCB.

ADS1230IPWR

✅ بديل مباشر
📦 16-pin TSSOP (PW)
Same 20-bit resolution, 80 SPS maximum rate, 1-channel differential input, and 16-pin TSSOP electrical configuration; the suffix changes the tape-and-reel ordering format

📋 بديل مرجعي (غير موجود في الكتالوج)

ADS1230IPW الحدود القصوى والخصائص الكهربائية

ADC Type Delta-sigma ADC
الدقة 20 bit
Number of Input Channels 1 channel
Maximum Sampling Rate 80 SPS
جهد التغذية 5 V
Programmable Gain Amplifier Integrated
PGA Gains 1, 2, 64, and 128
Internal Oscillator Integrated
Linearity Error 0.001%
Input Type Differential bridge-sensor input
العلبة 16-pin TSSOP (PW)
Terminal Pitch 0.65 mm
نوع التركيب Surface mount

دليل تكوين أطراف ADS1230IPW 16-pin tssop (pw)

تكوين الأطراف لـ ADS1230IPW (حزمة 16-pin tssop (pw)). يتميز هذا المكوّن التناظري بأطراف الإدخال والإخراج وإمداد الطاقة. راجع ورقة بيانات الشركة المصنعة لتكوينات طرف إلغاء الإزاحة والتعويض والتمكين. مثالي لدوائر تكييف الإشارة والمضخمات.

مخطط توزيع أطراف حزمة 16-pin tssop (pw) لـ ADS1230IPW

لا تتوفر بيانات مفصلة لمخطط التوصيلات لـ ADS1230IPW.

راجع ورقة البيانات للحصول على تكوين الأطراف الكامل.

التطبيقات النموذجية

ADS1230IPW مناسب لـ 6 التطبيقs: Industrial Weighing Systems, Strain-Gauge Instrumentation, Resistive Pressure Transducers, Force and Torque Measurement, Laboratory Measurement Instruments, Battery-Powered Portable Sensors.

⚡

Industrial Weighing Systems

The ADS1230IPW fits industrial load-cell front ends that measure a slowly changing differential bridge signal with high resolution. Its 20-bit conversion capability, selectable gains of 1, 2, 64, and 128, and 80 SPS maximum rate provide ample conversion speed for static or moderately filtered weight readings. The integrated PGA and oscillator reduce the number of external low-level analog and timing components, although bridge excitation and the external reference must remain stable to preserve weighing accuracy.

🏭

Strain-Gauge Instrumentation

The ADS1230IPW is appropriate for strain-gauge monitoring where the bridge produces a small differential output around a larger common-mode voltage. Programmable gains of 64 and 128 amplify low-milliamp or microvolt-level changes before the 20-bit delta-sigma conversion stage, while the 80 SPS ceiling is suitable for structural loads, force fixtures, and test systems that do not require waveform capture. Close analog routing and a clean reference path are essential for preserving the converter's measurement quality.

🧩

Resistive Pressure Transducers

The ADS1230IPW can digitize bridge-based pressure sensors whose resistance changes slightly under applied pressure. The integrated low-noise PGA supports sensitivity levels from 1 through 128, and the 20-bit resolution is useful for detecting small differential changes. An 80 SPS maximum rate is suitable for process monitoring and pressure-panel displays, but it should be reduced when lower output noise is required. Mechanical pressure cycling and sensor self-heating must also be considered during calibration.

🔧

Force and Torque Measurement

The ADS1230IPW suits compact force or torque instrumentation built around resistive bridges because it combines differential analog input, programmable amplification, a 20-bit ADC, and an internal oscillator in one package. The converter's 80 SPS limit is ample for static load acquisition and controlled test cycles, while the available gains permit a useful match to the sensor's millivolt-level output. For dynamic force analysis, an external anti-alias network and higher-rate converter may be preferable.

🖥️

Laboratory Measurement Instruments

The ADS1230IPW can serve as the acquisition element in precision laboratory instruments that monitor resistive sensor bridges through a control or measurement panel. Its integrated oscillator simplifies standalone operation, and the 20-bit resolution supports careful characterization of small changes in load, displacement, or stress. The 80 SPS maximum data rate makes it best for slow measurements rather than high-bandwidth laboratory signals. Reference layout, excitation settling, and digital filtering remain the principal accuracy considerations.

📱

Battery-Powered Portable Sensors

The ADS1230IPW is suitable for portable battery-operated sensor modules when measurement bandwidth is modest and analog simplicity is important. Integrating the low-noise PGA, 20-bit delta-sigma converter, and onboard oscillator reduces component count compared with a discrete precision measurement front end. The 80 SPS rate is more than adequate for many portable load, strain, and pressure probes. The final power budget should still include bridge excitation consumption, regulator efficiency, and the selected data-rate mode.

What are the key specifications of ADS1230IPW that engineers should know?
The ADS1230IPW is a 20-bit, single-channel delta-sigma ADC with a maximum sampling rate of 80 SPS, an integrated programmable gain amplifier, and an onboard oscillator. According to the Texas Instruments ADS1230 product page and datasheet, its selectable PGA gains are 1, 2, 64, and 128, and the device operates from a 5 V supply. It is packaged in a 16-pin TSSOP with a 0.65 mm terminal pitch and is intended primarily for resistive bridge-sensor measurements such as load cells, strain gauges, and pressure sensors.
What is ADS1230IPW used for?
The ADS1230IPW is used for precision low-frequency measurements from resistive bridge sensors. Its differential input, selectable gains of 1, 2, 64, and 128, and 20-bit resolution suit strain gauges, weigh scales, and pressure transducers operating around a Wheatstone bridge. Texas Instruments describes it as a complete bridge-sensor front end because the low-noise PGA, onboard oscillator, and delta-sigma conversion stage are integrated into one device.
What is the sampling rate of ADS1230IPW?
The ADS1230IPW supports a maximum data rate of 80 samples per second. According to the Texas Instruments ADS1230 product page, it is a 20-bit, 80 SPS converter designed for bridge sensors rather than high-speed signal acquisition. This rate is appropriate for slowly changing physical quantities such as force, load, strain, and pressure. It may also be reduced through the device's data-rate and operating-mode configuration to improve noise performance.
What is the resolution and linearity of ADS1230IPW?
The ADS1230IPW provides 20-bit resolution with a stated linearity error of 0.001%. According to the Texas Instruments ADS1230 documentation, the converter is intended for precision bridge-sensor measurements where small differential signals must be resolved accurately. Practical system accuracy also depends on excitation stability, reference quality, bridge resistance matching, PCB layout, and the selected PGA gain.
Which PGA gains does ADS1230IPW support?
The ADS1230IPW supports programmable gains of 1, 2, 64, and 128. According to the Texas Instruments ADS1230 product page, the onboard low-noise PGA can amplify small bridge-sensor outputs before conversion while preserving a useful common-mode range. Gain selection should account for the sensor's full-scale differential output, bridge excitation voltage, input common-mode voltage, and the ADC's permitted analog input range.
Where can I download the ADS1230IPW datasheet PDF?
The official ADS1230IPW datasheet is available through the Texas Instruments ADS1230 product support page and the linked manufacturer datasheet document. The device page identifies the part as a 20-bit, 80 SPS, one-channel delta-sigma ADC for resistive bridge sensors. Engineers should use the TI document for the authoritative pin description, electrical characteristics, recommended application circuit, and digital-interface timing before finalizing a PCB or firmware design.
Where can I find the ADS1230IPW pinout and package information?
The ADS1230IPW uses a 16-pin TSSOP package with 0.65 mm terminal pitch, and its complete pin description is shown in the Texas Instruments ADS1230 datasheet. Use the pin-description table and package drawing to assign supplies, analog inputs, reference connections, digital interface signals, and ground pins. The present page does not reproduce the complete numbered pin table, so the manufacturer pinout should be followed directly during schematic capture and layout.
ADS1230IPW vs ADS1259IPWR - which is better for a bridge sensor?
The ADS1230IPW is preferable when a bridge-sensor design requires low noise and a maximum rate of only 80 SPS, while the ADS1259IPWR is preferable for much faster conversion and higher resolution. According to the published comparison, ADS1259IPWR provides 24-bit resolution and up to 14.4 kSPS, whereas ADS1230IPW provides 20-bit resolution and 80 SPS. Their sampling-rate difference is too large to treat them as unconditional drop-in replacements.
Can ADS1230IPWR replace ADS1230IPW in an existing design?
The ADS1230IPWR can serve as a drop-in ordering replacement when the original ADS1230IPW was supplied in a tape-and-reel format and its electrical configuration remains unchanged. Both parts are identified as 20-bit, single-input delta-sigma ADCs in 16-pin TSSOP packages. The suffix primarily changes the shipping format, so PCB layout and circuitry are unchanged; approved ordering notation and supply-chain requirements should still be checked before substitution.
What can replace ADS1230IPW?
The closest confirmed replacement is ADS1230IPWR, which retains the same 20-bit, single-channel, 80 SPS ADS1230 configuration in a 16-pin TSSOP package. Devices such as ADS1259IPWR, ADS122U04IPW, and ADS1220IPW may share related application categories or package dimensions, but their resolution, sampling speed, interface, or channel configurations differ. They should therefore be treated as redesign candidates rather than automatic pin-to-pin replacements.
When should I choose ADS1230IPW over a higher-speed ADC?
Choose ADS1230IPW when the measured quantity changes slowly and high resolution is more important than rapid acquisition. Its 20-bit converter, 80 SPS maximum rate, integrated low-noise PGA, and onboard oscillator provide a focused solution for strain gauges, weigh scales, and pressure sensors. Select a faster ADC only when the application must capture rapid transients, requires substantially more than 80 conversions per second, or needs a different digital interface.
Is ADS1230IPW suitable for load cells and pressure sensors?
The ADS1230IPW is suitable for load cells and resistive pressure sensors operated through a Wheatstone bridge. According to the Texas Instruments product documentation, its differential bridge input, programmable gains of 1, 2, 64, and 128, and integrated oscillator support compact measurement systems. The bridge excitation and external reference must remain stable because their errors contribute directly to the final weight, force, or pressure reading.
Does ADS1230IPW need an external clock?
The ADS1230IPW includes an onboard oscillator, so it does not require an external clock for normal bridge-sensor operation. According to the Texas Instruments ADS1230 product page, the onboard oscillator is one of the functions integrated into the complete measurement front end. The datasheet also describes clock-related interface considerations, so a system requiring a deterministic external synchronization scheme should review those operating modes before committing to the device.
Is ADS1230IPW in stock and what is its lead time?
Current stock, minimum order quantity, and lead time for ADS1230IPW should be confirmed through the Request a Quote form on this page. The manufacturer lists the device as an active ADS1230 product, but inventory conditions can vary by package, quantity, and shipment destination. Submit the required quantity and target delivery date with the quote request to obtain a current sourcing commitment.
Where can I buy ADS1230IPW and what is the price?
Use the Request a Quote form on this page to request current ADS1230IPW pricing, stock, and lead time. The part is the 16-pin TSSOP version of Texas Instruments' 20-bit, 80 SPS bridge-sensor ADC. Pricing can change with order quantity, delivery schedule, and market conditions, so a current quotation is more useful than a static historical figure when budgeting a new production run.

بيانات مرجعية هندسية لـ ADS1230IPW — المقارنة وإرشادات التصميم ومعلومات الامتثال.

دليل الاختيار

Choose the ADS1230IPW when the design converts a low-level differential bridge signal from a strain gauge, load cell, or pressure sensor and values high resolution, integrated gain, and simple clocking more than rapid acquisition. Its 80 SPS maximum rate is suitable for static or moderately filtered measurements, while the 20-bit resolution supports fine changes in the measured quantity. The ADS1230IPWR is the preferred alternate ordering source when the same electrical device is needed in a tape-and-reel presentation. ADS1259IPWR should be considered only when substantially faster sampling or 24-bit resolution is required, because its 14.4 kSPS maximum rate is architecturally different. ADS122U04IPW and ADS1220IPW require an interface, channel, or performance review and are not automatic replacements. For any substitution, verify the complete pin map, supply voltage, reference arrangement, digital protocol, register behavior, and acquisition timing rather than relying on package dimensions alone.

المقارنة مع البدائل

المعامل هذا المنتج ADS1230IPWR
Brand Texas Instruments Texas Instruments
Package 16-pin TSSOP (PW) 16-pin TSSOP (PW) - same
ADC Architecture Delta-sigma ADC Delta-sigma ADC
Resolution 20 bit 20 bit
Maximum Sampling Rate 80 SPS 80 SPS
Input Channels 1 channel 1 channel
PGA Gains 1, 2, 64, and 128 1, 2, 64, and 128
Internal Oscillator Integrated Integrated
Supply Voltage 5 V 5 V
Linearity Error 0.001% 0.001%

أبرز الفروقات

  • Complete bridge-sensor signal chain (مقابلADS1230IPWR)
  • Higher speed than the bridge-focused ADS1230 (مقابلADS1259IPWR)
  • Higher resolution in the same broad sensor-converter class (مقابلADS122U04IPW)
  • Purpose-built low-speed precision bridge measurement (مقابلADS1220IPW)

ملاحظات التصميم

Route the differential bridge inputs as a compact, symmetric pair and keep them away from switching regulators, relays, and high-current return paths. The small bridge signal makes pickup and ground-potential errors directly relevant to accuracy. Place input filtering and reference components close to the analog pins, follow the Texas Instruments ADS1230 recommended application circuit, and provide a low-impedance ground return for the analog supply.

Treat bridge excitation and reference stability as part of the measurement accuracy budget. A change in excitation voltage changes the bridge output, while reference drift changes the ADC conversion scale. Use stable, low-noise sources and avoid routing analog return current through digital switching paths. Select the PGA gain so the largest expected bridge differential and common-mode excursion remain within the ADS1230 analog input limits.

The 80 SPS ceiling should be used deliberately because it is not a high-speed acquisition rating. Lowering the data rate generally narrows the effective noise bandwidth and can improve bridge-sensor readings, but it also reduces response time. Choose anti-alias and input-filter values with the intended bandwidth and update interval, and allow the digital filter to settle after power-up, gain changes, or configuration commands.

Do not assume that a related 16-pin ADC is interchangeable merely because the package matches. ADS1259IPWR reaches 14.4 kSPS with 24-bit resolution, while ADS122U04IPW and ADS1220IPW differ in channel count, interface, speed, or front-end behavior. Validate supply levels, pin functions, digital protocol, clocking, register compatibility, and electrical performance before replacing the ADS1230IPW in a production design.

معلومات الامتثال

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
خالٍ من الرصاص
Unknown
خالٍ من الهالوجين
Unknown
المعادن المتنازع عليها
Unknown

The available manufacturer and distributor pages do not provide extractable values for the listed environmental and material compliance fields.

عمليات بحث ذات صلة

ADS1230IPW datasheet ADS1230IPW specifications ADS1230IPW pinout ADS1230IPW datasheet pdf ADS1230IPW application circuit ADS1230IPW bridge sensor ADC ADS1230IPW vs ADS1259IPWR ADS1230IPW equivalent ADS1230IPW replacement ADS1230IPW price ADS1230IPW stock Texas Instruments ADS1230IPW ADS1230IPW TSSOP-16 footprint ADS1230 20-bit 80 SPS ADC ADS1230IPW load cell circuit

المكونات والمصطلحات ذات الصلة

Texas Instruments ADS1230IPW ADS1230IPWR ADS1259IPWR ADS122U04IPW ADS1220IPW delta-sigma ADC analog-to-digital converter ADC precision ADC bridge-sensor ADC programmable gain amplifier PGA Wheatstone bridge load cell strain gauge pressure sensor onboard oscillator 20-bit resolution 80 SPS differential input TSSOP-16 surface-mount package weigh scale power supply rejection RoHS REACH
عرض سعر سريع RFQ
املأ التفاصيل الكاملة — سيرد فريق المبيعات لدينا خلال 24 ساعة
رقم القطعة الشركة المصنعة الحزمة QTY السعر المستهدف الإجمالي
✓
تم إرسال عرض السعر!

سنرد على بريدك الإلكتروني خلال 24 ساعة

1
تم إرسال طلب عرض السعر
2
تم استلام عرض السعر
3
تم تقديم الطلب
4
الدفع
5
تم الشحن
6
تم التسليم
عرض تفاصيل طلب عرض السعر