A CMOS liquid-crystal display driver is a logic-family device that accepts digital control information and produces the electrical drive signals required by compatible LCD segments. Within the broader semiconductor hierarchy, the CD4056BEX belongs to CMOS logic, interface ICs, and display-driver ICs. Its primary role is signal generation and display-segment control rather than computation, analog amplification, or power conversion.
The principal feature visible in the manufacturer documentation is the combination of a CMOS display-driver function, active device status, and a 14-DIP package. The suffix EX denotes the manufacturer's extended-temperature ordering option, while the B family designation identifies the CD4056B implementation. The family documentation identifies the device category as a CMOS liquid-crystal display driver, making it appropriate for designs using compatible segmented LCD displays.
The CD4056BEX architecture is implemented in CMOS logic, allowing digital control signals to interface with LCD segment structures while limiting the device to the logic-level voltage range specified by the family documentation. Because the display characteristics depend on the selected LCD, supply voltage, operating environment, and external configuration, the exact drive voltage, segment count, output configuration, and timing limits must be confirmed in the manufacturer datasheet before schematic approval.
Typical uses include digital instrument panels, counters, industrial panel meters, small monochrome LCD modules, and embedded control systems that require a dedicated display-driver IC. In each case, the LCD glass and segment arrangement determine whether the CD4056BEX is suitable. Designers should verify segment count, common and segment electrode topology, bias requirements, and logic compatibility rather than selecting the driver from package size alone.
A critical design practice is to compare every LCD electrode with the manufacturer's pin-description and truth-table information before routing the PCB. Supply bypassing, unused inputs, and display contrast should be evaluated together because the LCD threshold voltages, rather than ordinary digital logic levels alone, determine whether segments illuminate reliably.
This page combines the identified CD4056BEX package and lifecycle information with engineering guidance for LCD interface design, pin verification, PCB implementation, and component sourcing. It also distinguishes documented facts from parameters that must be checked against the manufacturer datasheet, helping engineers plan the display subsystem before layout begins.
بدائل مباشرة لـ CD4056BEX — نفس الحزمة، متوافق دبوس بدبوس. تُستثنى القطع ذات الحزم المختلفة التي تتطلب تعديل PCB.
الطرازات في هذه السلسلة
طرازات من نفس السلسلة متوافقة تمامًا مع CD4056BEX (نفس عامل الشكل والبصمة) — يختلف في Logic Family, Manufacturer, Product Type.
CD4056BE
✅ بديل مباشر ⚠️ مواصفات غير مُتحقق منها📋 بديل مرجعي (غير موجود في الكتالوج)
CD4056BF
✅ بديل مباشر ⚠️ مواصفات غير مُتحقق منهاتواصل لمعرفة السعر
عرض ورقة البيانات ←CD4056BP
✅ بديل مباشر ⚠️ مواصفات غير مُتحقق منها📋 بديل مرجعي (غير موجود في الكتالوج)
CD4056BCN
✅ بديل مباشر ⚠️ مواصفات غير مُتحقق منها📋 بديل مرجعي (غير موجود في الكتالوج)
CD4056BD
✅ بديل مباشر ⚠️ مواصفات غير مُتحقق منها📋 بديل مرجعي (غير موجود في الكتالوج)
CD4056BEX المواصفات
| Manufacturer | Harris Corporation |
| Product Type | CMOS liquid-crystal display driver |
| Logic Family | CD4000 CMOS |
| Device Family | CD4056B |
| Package Type | 14-DIP |
| عدد الأطراف | 14 pins |
| Lead-Row Spacing | 0.300 inch (7.62 mm) |
| نمط التركيب | Through-hole |
| حالة دورة الحياة | Active |
| Reported Inventory | 1,550 units |
دليل تكوين أطراف CD4056BEX 14-dip
تكوين الأطراف لـ CD4056BEX (حزمة 14-dip). يتم تعريف ترقيم الأطراف والوظائف ومخططات التوصيل في ورقة البيانات الفنية من الشركة المصنعة. راجعها للحصول على البصمة الدقيقة وإرشادات اللحام.
لا تتوفر بيانات مفصلة لمخطط التوصيلات لـ CD4056BEX.
راجع ورقة البيانات للحصول على تكوين الأطراف الكامل.
التطبيقات النموذجية
CD4056BEX مناسب لـ 6 التطبيقs: Digital Instrument Panels, Industrial Panel Meters, Electronic Counters and Timers, Small Monochrome LCD Modules, Portable Measurement Equipment, Legacy Display-System Repair.
Digital Instrument Panels
The CD4056BEX is suitable for digital instrument panels that use a compatible segmented monochrome LCD, such as measurement instruments, timers, and bench equipment. Its documented CMOS liquid-crystal display-driver function is intended to translate digital control information into display-segment drive signals. The 14-DIP package also makes it convenient for through-hole prototypes and repair assemblies. Before routing the board, map every LCD segment and common electrode to the manufacturer pin description, verify the required bias and supply conditions, and confirm that the EX ordering option meets the instrument's temperature specification.
موصى به
Industrial Panel Meters
An industrial panel meter can use the CD4056BEX when its display has the segment count and electrode arrangement supported by the CD4056 family. This application benefits from a dedicated display driver rather than burdening the controller with repetitive LCD timing and electrode-control logic. The through-hole 14-DIP package is practical for meter platforms assembled with conventional PCB processes. Confirm the panel's voltage thresholds, drive waveform, viewing temperature, and ESD environment against the manufacturer datasheet, and reserve PCB clearance for the 0.300 inch lead-row spacing.
موصى به
Electronic Counters and Timers
The CD4056BEX fits counters, timers, and event-display modules that use a simple segmented LCD. Digital count or elapsed-time information can be presented through the display-driver outputs while the controlling logic maintains the counting function and operating sequence. This arrangement keeps display wiring separate from the main signal path and provides a conventional through-hole option for laboratory or industrial counter boards. Verify the number and arrangement of LCD outputs, input timing, supply requirements, and unused-input states before fixing the schematic, since those details must follow the manufacturer datasheet.
موصى به
Small Monochrome LCD Modules
The CD4056BEX can be evaluated for small monochrome LCD modules used in control, status, and diagnostic equipment. Its liquid-crystal display-driver function makes it relevant where the module requires dedicated segment control, while the DIP package allows socketed assembly during prototype development. Compatibility depends on matching the module's segment and common lines, expected drive levels, and operating environment to the manufacturer's device documentation. Confirm whether the module requires a different bias method or output count before committing to the PCB footprint and external component arrangement.
موصى به
Portable Measurement Equipment
The CD4056BEX is applicable to portable measurement equipment that includes a small LCD for displaying readings, units, status, or set points. A dedicated display driver can separate display control from the analog measurement and processing circuitry, helping organize the system architecture. The 14-DIP package is practical for battery-powered prototypes assembled by hand and for legacy repairs. The designer should still verify operating supply limits, quiescent consumption, temperature behavior, and display drive requirements directly from the manufacturer datasheet before optimizing battery life or approving the enclosure temperature range.
موصى به
Legacy Display-System Repair
The CD4056BEX is useful for repairing or extending older equipment built around Harris CD4056-family LCD circuitry. The active listing and documented 14-DIP package make it relevant to boards that require a through-hole replacement rather than a redesigned surface-mount solution. Before installation, compare the original device's manufacturer markings, suffix, pin assignment, and temperature grade with the replacement documentation. If the original part was from another producer, verify every output and supply connection rather than assuming that a matching 14-DIP outline guarantees functional compatibility.
موصى به
ملخص المنتجات الموصى بها
بيانات مرجعية هندسية لـ CD4056BEX — المقارنة وإرشادات التصميم ومعلومات الامتثال.
دليل الاختيار
المقارنة مع البدائل
| المعامل | هذا المنتج |
|---|---|
| Manufacturer | Harris Corporation |
| Product Type | CMOS liquid-crystal display driver |
| Package | 14-DIP |
| Pin Count | 14 pins |
| Lead-Row Spacing | 0.300 inch (7.62 mm) |
| Mounting Style | Through-hole |
| Lifecycle Status | Active |
| Ordering Suffix | EX |
أبرز الفروقات
- Documented active lifecycle status (مقابلGeneric CD4056 family listing)
- Exact EX ordering configuration (مقابلCD4056 family designation)
- Established 14-DIP mechanical format (مقابلSurface-mount LCD-driver concepts)
ملاحظات التصميم
Create the PCB footprint from the manufacturer package drawing rather than from a generic DIP outline. The documented lead-row spacing is 0.300 inch, or 7.62 mm, but hole diameter, lead length, and body width must also follow the official drawing. Confirm the pin-1 orientation and match each LCD electrode to the numbered pin in the datasheet. For repair-oriented boards, also check solderability and whether an alternate socket footprint is needed for serviceability.
Do not select the driver solely because the LCD is described as an LCD. Build a compatibility matrix covering segment count, common-electrode count, display bias, supply voltage, logic thresholds, drive timing, and temperature range. Use the manufacturer truth table to identify required control sequences and any unused inputs. An apparently identical 14-DIP display driver can still differ in output assignment or timing, so every alternative must be checked against the original CD4056BEX datasheet.
Plan the supply network only after confirming the CD4056BEX operating-voltage range and the LCD module's voltage requirements in the manufacturer datasheet. Place the required bypass capacitor close to the supply pins, keep the display output traces short, and maintain a return path that does not share noisy switching-current paths with sensitive circuitry. Verify that all control inputs remain at valid logic levels during reset and power transitions so the display cannot present unintended segment states.
Separate LCD segment routes from high-speed, high-current, or switching nodes to reduce coupling into the display and control circuitry. Use a common ground reference and avoid routing return current beneath the LCD driver when another low-impedance path is available. Keep connector and keypad wiring away from segment outputs, and provide adequate spacing around exposed leads for inspection and rework. Apply the manufacturer's handling and ESD requirements during assembly and servicing.
معلومات الامتثال
No specific RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals statements are identified for this exact part. The EX suffix identifies the ordering-temperature option and should not be interpreted as an automotive qualification statement.