ICL7136CM44 - 3.5-Digit LCD ADC | Analog Devices
MPN: ICL7136CM44 ✗ انتهى عمره الإنتاجيICL7136CM44 نظرة عامة
An integrated 3.5-digit ADC is a special-purpose data-acquisition IC that converts an analog input voltage into a numerical code and then drives a numeric display. Within the broader semiconductor hierarchy, the ICL7136 belongs to the ADC/DAC class and integrates measurement conversion, decoding, display excitation, reference voltage, and timing into one package. This integration removes the need for separate display drivers in many panel-meter and laboratory-instrument designs.
Key characteristics include a 3.5-digit measurement format, two display-related channels, integrated seven-segment decoding, a multiplexed LCD backplane output, automatic zeroing, and a 0°C to 70°C operating-temperature range. The device is supplied in a 44-QFP surface-mount package, allowing compact instrumentation layouts without through-hole interconnects. The exact converter resolution, input ranges, timing, current consumption, and absolute maximum ratings must be confirmed in the manufacturer datasheet before final circuit design.
The ICL7136 architecture is intended for low-power display measurement rather than high-speed waveform acquisition. Its integrated clock and reference establish the measurement framework, while automatic zeroing helps remove offset-related error during conversion. Because display excitation is included, the external interface can concentrate on the analog input network, protection components, display selection, and mechanical arrangement of the readout.
Typical uses include digital panel meters, laboratory meters, process-monitoring equipment, portable instrumentation, temperature-measurement instruments, and other systems that present a three-and-a-half-digit decimal value on an LCD. The ICL7136 family is also associated with replacing an ICL7126 while eliminating overrange hangover and hysteresis effects. Exact display compatibility, input conditioning, and timing should be confirmed against the relevant package variant.
A key design consideration is the relationship among the analog input, reference voltage, clock source, LCD characteristics, and bypass components. Follow the manufacturer recommended application circuit and pin-description table because display drive timing, segment mapping, and input configuration are package-specific. Use the complete pinout and electrical limits from the manufacturer datasheet when assigning PCB tracks.
This page combines lifecycle information, package and functional attributes, focused drop-in candidates, comparison parameters, and practical application guidance. These engineering views help buyers identify the correct ICL7136 package variant while distinguishing it from unrelated ADC families and display-driver packages.
بدائل مباشرة لـ ICL7136CM44 — نفس الحزمة، متوافق دبوس بدبوس. تُستثنى القطع ذات الحزم المختلفة التي تتطلب تعديل PCB.
ICL7136CM44Z
✅ بديل مباشر📋 بديل مرجعي (غير موجود في الكتالوج)
ICL7136CM44Z-03
✅ بديل مباشر📋 بديل مرجعي (غير موجود في الكتالوج)
ICL7136CMH+D
✅ بديل مباشر📋 بديل مرجعي (غير موجود في الكتالوج)
ICL7136CMH-D
✅ بديل مباشر📋 بديل مرجعي (غير موجود في الكتالوج)
ICL7136CM44 الحدود القصوى والخصائص الكهربائية
| Device Type | 3.5-digit low-power analog-to-digital converter with display driver |
| Displayed Resolution | 3.5 digits |
| Number of Channels | 2 channels |
| Input Type | Single-ended analog voltage input |
| Integrated Functions | Seven-segment decoder, display driver, voltage reference, and clock |
| Display Output | Direct LCD drive with multiplexed backplane |
| Zeroing Method | Automatic zeroing |
| درجة حرارة التشغيل | 0°C to 70°C |
| العلبة | 44-QFP |
| Package Dimensions | 10 mm x 10 mm |
| نوع التركيب | Surface mount |
| Product Category | ADCs/DACs - Special Purpose |
| Product Status | Obsolete |
دليل تكوين أطراف ICL7136CM44 10 mm x 10 mm
تكوين الأطراف لـ ICL7136CM44 (حزمة 10 mm x 10 mm). يتميز هذا المكوّن التناظري بأطراف الإدخال والإخراج وإمداد الطاقة. راجع ورقة بيانات الشركة المصنعة لتكوينات طرف إلغاء الإزاحة والتعويض والتمكين. مثالي لدوائر تكييف الإشارة والمضخمات.
لا تتوفر بيانات مفصلة لمخطط التوصيلات لـ ICL7136CM44.
راجع ورقة البيانات للحصول على تكوين الأطراف الكامل.
التطبيقات النموذجية
ICL7136CM44 مناسب لـ 6 التطبيقs: Digital Panel Meters, Laboratory Voltage Measurement, Process Monitoring Instruments, Temperature Measurement Displays, Portable Test Instruments, Laboratory Data-Logging Readouts.
Digital Panel Meters
The ICL7136CM44 is suited to digital panel meters because it combines a 3.5-digit analog-to-digital conversion function with seven-segment decoding and display-driver outputs. The integration reduces the number of components required to present a measurement directly on a multiplexed LCD. Its 44-QFP surface-mount package also supports compact meter electronics. Before finalizing the design, verify the exact LCD segment mapping, backplane outputs, reference arrangement, and pin functions in the manufacturer datasheet.
موصى به
Laboratory Voltage Measurement
ICL7136CM44 can serve as the central measurement and readout device in a laboratory voltage instrument. Its integrated clock, reference, seven-segment decoders, and display drivers support a compact front panel, while the 3.5-digit format is appropriate for displays such as 0.000 or 19.99. Because this converter targets display-oriented measurement rather than high-speed sampling, use it for stable readings and confirm input-reference and timing details from the manufacturer datasheet.
موصى به
Process Monitoring Instruments
The ICL7136CM44 is appropriate for industrial process-monitoring equipment that must show a controlled process variable on a local LCD. Its integrated display excitation simplifies the signal chain from an analog sensor or transmitter to a numerical panel, and its 0°C to 70°C catalog operating range covers many commercial environments. The input-conditioning network, protection strategy, and reference behavior must be designed from the exact ICL7136CM44 electrical characteristics rather than inferred from a generic ADC.
موصى به
Temperature Measurement Displays
ICL7136CM44 can drive a decimal temperature readout when the output of a suitable linearized temperature sensor is conditioned into the converter's input range. The integrated decoder and display drivers allow the instrument to show temperature directly without a separate display controller. System accuracy will depend on sensor linearity, reference stability, input filtering, and calibration. Confirm the input range, reference voltage, conversion sequence, and display timing in the manufacturer datasheet before production.
موصى به
Portable Test Instruments
The ICL7136CM44 is useful in portable meters and service instruments where a low-power numerical LCD provides the primary user interface. Its integrated clock, reference, segment decoder, and LCD drivers reduce board area and external logic compared with a discrete measurement chain. The 44-QFP package avoids through-hole pins, although careful grounding and input protection remain essential in handheld equipment. Validate battery compatibility, operating current, startup behavior, and LCD drive compatibility against the exact manufacturer documentation.
موصى به
Laboratory Data-Logging Readouts
ICL7136CM44 can provide a local numerical readout in data-logging or test equipment where operators need a visible value alongside external data collection. The converter handles analog measurement, decoding, and LCD excitation in one device, leaving the system controller free to handle logging functions. The 3.5-digit resolution suits conventional panel-meter indications rather than high-resolution graphing. Confirm that the converter's measurement cycle and display timing are appropriate for the application.
موصى به
ملخص المنتجات الموصى بها
بيانات مرجعية هندسية لـ ICL7136CM44 — المقارنة وإرشادات التصميم ومعلومات الامتثال.
دليل الاختيار
المقارنة مع البدائل
| المعامل | هذا المنتج | ICL7136CM44Z | ICL7136CM44Z-03 | ICL7136CMH+D | ICL7136CMH-D |
|---|---|---|---|---|---|
| Package | 44-QFP | 44-MQFP (10 mm x 10 mm) | 44-QFP | 44-QFP | 44-QFP |
| Brand | Analog Devices | Renesas Electronics | Renesas Electronics | Analog Devices | Maxim Integrated |
| Converter Format | 3.5-digit A/D converter | 3.5-digit A/D converter | 3.5-digit A/D converter | 3.5-digit A/D converter | 3.5-digit A/D converter |
| Display Type | LCD with multiplexed backplane drive | LCD with multiplexed backplane drive | LCD with multiplexed backplane drive | LCD with multiplexed backplane drive | LCD with multiplexed backplane drive |
| Integrated Functions | Seven-segment decoders, display drivers, reference, and clock | Seven-segment decoders, display drivers, reference, and clock | Seven-segment decoders, display drivers, reference, and clock | Seven-segment decoders, display drivers, reference, and clock | Seven-segment decoders, display drivers, reference, and clock |
| Mounting Type | Surface mount | Surface mount | Surface mount | Surface mount | Surface mount |
| Zeroing Method | Automatic zeroing | Automatic zeroing | Automatic zeroing | Automatic zeroing | Automatic zeroing |
أبرز الفروقات
- Complete 3.5-digit measurement-to-display integration (مقابلICL7136CM44Z)
- Direct multiplexed LCD excitation (مقابلICL7136CMH+D)
- Integrated automatic zeroing for offset reduction (مقابلICL7136CMH-D)
ملاحظات التصميم
Assign the PCB footprint from the exact 44-QFP ordering code and its manufacturer package drawing rather than from the converter family name alone. Confirm pin 1 orientation, exposed-pad treatment, pad dimensions, and solder-mask clearance before releasing artwork. The target has no documented 44-pin SVG key in the package library, so use the manufacturer land pattern and verify it during PCB review.
Keep the analog input path short, shielded from LCD drive and clock traces, and return through a quiet ground reference. Place input filtering and protection components close to the relevant converter pins when the circuit permits. Because the ICL7136 combines high-impedance measurement with multiplexed display excitation, PCB leakage, contaminated boards, and ground-current coupling can affect displayed readings.
Do not interchange ICL7136 suffixes solely because their catalog descriptions are similar. Check the pin-description table, LCD segment assignments, backplane outputs, supply limits, reference configuration, conversion timing, temperature grade, and ordering code for the proposed replacement. A mechanically similar 44-pin package can still differ in electrically significant pin functions or operating classification.
Follow the manufacturer recommended bypass and reference-decoupling arrangement. Keep switching-regulator and display-related noise sources physically separated from the high-impedance input node, and route converter ground carefully through the display and supply returns. Confirm operating current and permissible supply voltage from the datasheet because those values are essential when calculating battery life and regulator headroom.
معلومات الامتثال
Compliance declarations were not identified for the exact obsolete ICL7136CM44 ordering code. Confirm RoHS, REACH, halogen, and conflict-minerals documentation for the actual manufacturer and lot before use.