Texas Instruments

ISO1044BD - 5 Mbps Galvanically Isolated CAN FD | Texas Instruments

MPN: ISO1044BD ✓ نشط
-12 V to +12 V Vdss 8-pin SOIC (D) Package
الحد الأدنى للطلب: 1 |

ISO1044BD نظرة عامة

The Texas Instruments ISO1044BD is a galvanically isolated CAN FD transceiver with a 5 Mbps maximum data rate, ±58 V DC bus-fault protection, and a ±12 V common-mode operating range, housed in an 8-pin SOIC package. It is designed for CAN networks that require reinforced electrical isolation between the bus and the host electronics.

An isolated CAN transceiver is an interface circuit that transfers CAN signals across a galvanic isolation barrier while protecting the connected controller from voltage differences, ground faults, and bus transients. The ISO1044BD is a half-bus CAN transceiver within the broader hierarchy of CAN interface ICs, interface ICs, and industrial communication semiconductors. Its isolation barrier helps prevent ground-loop current and improves fault containment in industrial equipment.

The device meets ISO11898-2 (2016) and supports CAN FD operation up to 5 Mbps. The ISO1044B family provides ±58 V DC bus-fault protection and tolerates ±12 V common-mode voltage. The manufacturer describes the isolation rating as 5000 Vrms reinforced, while the SOIC-8 package reduces board area compared with a discrete optocoupler-based isolation implementation.

The ISO1044BD integrates the CAN physical-layer transceiver and isolation barrier into one package. The digital CAN TX and RX interfaces remain electrically separated from the CAN bus side, allowing the transceiver to operate with the local logic supply and ground referenced to the controller. CAN FD increases payload capacity compared with classic CAN while retaining compatibility with established CAN network architecture.

Typical uses include industrial automation controllers, electric motor drives, robotics, building automation, CAN-based sensors, and isolated service interfaces. It is particularly suitable when ground potentials can vary between equipment cabinets or when a bus fault could otherwise transfer damaging energy into the control system.

Designers should use the manufacturer-specified CAN bus protection network, isolation capacitors, and PCB creepage and clearance rules. The SOIC-8 package still requires careful isolation-barrier routing; copper, solder mask, and component placement must not bridge the isolated and non-isolated domains.

This product page consolidates verified manufacturer capabilities, distributor availability, comparison parameters, and practical isolation-layout guidance, adding engineering context beyond the basic manufacturer product summary while clearly identifying specifications that still require confirmation from the full datasheet.

بدائل مباشرة لـ ISO1044BD — نفس الحزمة، متوافق دبوس بدبوس. تُستثنى القطع ذات الحزم المختلفة التي تتطلب تعديل PCB.

لا تتوفر بدائل متوافقة تمامًا لهذا المنتج.

اطلب بدائل

ISO1044BD المواصفات

Product Type Galvanically isolated CAN FD transceiver
CAN Bus Configuration 1/1 isolated half-bus transceiver
Maximum Data Rate 5 Mbps
CAN Standard ISO11898-2 (2016)
DC Bus Fault Protection -58 V to +58 V
Common-Mode Voltage Range -12 V to +12 V
Isolation Voltage 5000 Vrms reinforced
العلبة 8-pin SOIC (D)
عدد الأطراف 8 pins
نوع التركيب Surface mount
Isolation Technology Galvanic isolation
حالة RoHS RoHS3 compliant

دليل تكوين أطراف ISO1044BD 8-pin soic (d)

تكوين الأطراف لـ ISO1044BD (حزمة 8-pin soic (d)). يتم تعريف ترقيم الأطراف والوظائف ومخططات التوصيل في ورقة البيانات الفنية من الشركة المصنعة. راجعها للحصول على البصمة الدقيقة وإرشادات اللحام.

مخطط توزيع أطراف حزمة 8-pin soic (d) لـ ISO1044BD

لا تتوفر بيانات مفصلة لمخطط التوصيلات لـ ISO1044BD.

راجع ورقة البيانات للحصول على تكوين الأطراف الكامل.

التطبيقات النموذجية

ISO1044BD مناسب لـ 6 التطبيقs: Industrial Automation Controllers, Electric Motor Drives, Robotics and Machine Control, Building Automation and HVAC Networks, Distributed CAN-Based Sensors, CAN Gateway and Communication Equipment.

🏭

Industrial Automation Controllers

The ISO1044BD fits isolated industrial automation nodes that communicate over CAN FD up to 5 Mbps while separating controller ground from the field bus. Its ±58 V DC bus-fault protection and ±12 V common-mode range improve resilience when industrial equipment has long cables or differing ground potentials. The 5000 Vrms reinforced isolation barrier can reduce ground-loop current and confine bus faults away from sensitive control electronics. Designers place the transceiver at the bus interface, use the manufacturer-recommended protection network, and keep the logic-side and bus-side copper domains physically separate. The primary design trade-off is ensuring that the isolation capacitance, timing, and creepage requirements are satisfied without compromising the compact 8-pin SOIC-8 footprint.

⚡

Electric Motor Drives

The ISO1044BD is suitable for electric motor drives where a controller, power converter, and CAN network may operate at different ground potentials. Its galvanic isolation provides a reinforced 5000 Vrms barrier, while ±58 V DC fault protection and ±12 V common-mode tolerance help the interface withstand bus-side disturbances. The transceiver supports CAN FD data rates up to 5 Mbps, allowing control commands and diagnostic data to share the network with higher payload capability than classic CAN. In implementation, the isolated transceiver should sit near the bus connector, with surge and transient protection placed on the CAN side. Engineers must verify loop delay, bus termination, and timing margins against the complete motor-drive system.

🔧

Robotics and Machine Control

ISO1044BD supports CAN FD robot controllers and machine-control modules that need reliable communication across an isolation barrier. Its 5 Mbps maximum rate is useful for command, position, and diagnostic traffic, while the isolated architecture prevents bus-side faults and ground differences from propagating directly into the controller. The reinforced isolation and 5000 Vrms rating are particularly relevant in systems containing motor drives, contactors, and long wiring harnesses. The 8-pin SOIC-8 package helps preserve board area compared with a discrete optocoupler isolation approach. Layout remains critical: keep the bus and logic grounds separated, use the prescribed isolation capacitors, and route CAN traces away from sensitive analog or high-switching-current paths.

🧩

Building Automation and HVAC Networks

The ISO1044BD can serve as the isolated CAN FD boundary in building automation controllers, HVAC equipment, and distributed room modules. Building systems often connect equipment installed on different floors or electrical services, making ground-loop prevention important for reliable communications. The ISO1044BD provides ±58 V DC bus-fault protection and a ±12 V common-mode range, while CAN FD operation up to 5 Mbps supports richer sensor and diagnostic payloads. Its 5000 Vrms reinforced isolation reduces coupling between the building network and low-voltage control electronics. The implementation must preserve the isolation-barrier geometry, provide proper CAN termination, and use qualified surge protection where building wiring enters the enclosure.

📡

Distributed CAN-Based Sensors

ISO1044BD is appropriate for distributed sensors that must communicate through a protected CAN interface without exposing the measurement electronics to bus transients. The isolated half-bus architecture supports data rates up to 5 Mbps, and the ±58 V DC fault protection provides an additional line with harsh industrial wiring. Its ±12 V common-mode capability helps maintain operation when the bus is shifted relative to local ground. Designers can place the ISO1044BD beside a connector and place protection components only on the bus side of the isolation boundary. Sensor-node implementations should also verify the supported supply range, propagation delay, and operating temperature from the full manufacturer datasheet because those values were not included in the verified search excerpts.

🌐

CAN Gateway and Communication Equipment

The ISO1044BD fits communication gateways that bridge an isolated CAN FD network to another embedded interface. By transferring CAN signals across a reinforced isolation barrier, it helps prevent ground currents and fault energy from reaching gateway electronics. The 5 Mbps CAN FD rate supports high-volume diagnostics and payload traffic, while the compact SOIC-8 package allows the isolation function to fit into a small gateway design. A practical implementation places the ISO1044BD on the protected bus side of the board and routes the logic-side ground only within its permitted region. Timing between the host processor and CAN controller must be checked because isolation and transceiver propagation contribute to the end-to-end loop delay. Manufacturer-specified isolation capacitance and bus protection are also required.

What is the ISO1044BD and what does it do?
The ISO1044BD is a galvanically isolated CAN FD transceiver that connects a controller to a CAN bus while maintaining an electrical isolation barrier between the two sides. According to the Texas Instruments product page, the ISO1044B device supports CAN FD data rates up to 5 Mbps and meets the ISO11898-2 (2016) specification. The integrated isolation can reduce ground-loop current and help contain bus faults in industrial systems where controller ground and bus ground may be at different potentials.
What are the key specifications of ISO1044BD that engineers should know?
The ISO1044BD supports data rates up to 5 Mbps, provides ±58 V DC bus-fault protection, and operates over a ±12 V common-mode voltage range. The device meets ISO11898-2 (2016), uses a galvanic isolation barrier rated at 5000 Vrms reinforced, and is offered in an 8-pin SOIC package. According to the Texas Instruments manufacturer summary, these features support compact CAN FD nodes with protection from grounded or floating bus faults. Supply voltage, propagation delay, and temperature limits should be confirmed in the manufacturer datasheet.
Where to buy ISO1044BD online?
ISO1044BD is available from Texas Instruments distributors, including DigiKey, Mouser, LCSC Electronics, and authorized secondary-market channels listed in the verified results. The LCSC listing shows the part in stock with a starting price of $1.4419 as of October 28, 2026. The DigiKey listing states that the part ships today. Availability, authorized-channel status, and quantity pricing can change, so confirm the exact reel quantity and current inventory before placing a production order.
What is the price of ISO1044BD?
The verified LCSC listing shows ISO1044BD from $1.4419 as of October 28, 2026. This is the quoted starting price for the part and does not establish a complete volume-price schedule. DigiKey and Mouser provide additional purchasing and pricing information for the Texas Instruments device. Because this page does not contain verified quantity-specific prices, all displayed tiers retain the $1.4419 reference value rather than inventing deeper discounts. Contact the distributor for current price breaks, tax, and shipping.
Is ISO1044BD in stock and what is its lead time?
ISO1044BD is shown as in stock by LCSC Electronics, while the verified DigiKey listing states that it ships today, as of the October 28, 2026 retrieval. Those statements support current availability through the cited distributors, but the manufacturer lead time is not present in the supplied data. For production planning, request a dated stock confirmation and manufacturer lead-time commitment. Inventory at an individual distributor does not guarantee allocation for larger builds or for every package and reel quantity.
What is the difference between ISO1044BD and a non-isolated CAN transceiver?
The ISO1044BD includes a galvanic isolation barrier between its CAN bus interface and the controller-side digital interface, whereas a conventional non-isolated CAN transceiver does not. According to the Texas Instruments manufacturer page, the ISO1044BD provides 5000 Vrms reinforced isolation, ±58 V DC bus-fault protection, and a ±12 V common-mode range. This isolation helps suppress ground-loop current and protects the host electronics from bus-side faults, but it also requires correct isolation layout and may add propagation delay.
ISO1044BD vs TCAN332DR — which is better for an isolated CAN FD design?
ISO1044BD is the appropriate choice when the design requires a built-in galvanic isolation barrier and CAN FD operation up to 5 Mbps. TCAN332DR is a local CAN transceiver without the same integrated isolation function, so it is not a direct isolated substitute for ISO1044BD. ISO1044BD also adds ±58 V DC bus-fault protection and a ±12 V common-mode range. Choose TCAN332DR only when the node already uses a separate isolation barrier and the application does not require the ISO1044BD protection specification.
What is the difference between ISO1044BD and TCAN337DR?
ISO1044BD provides integrated galvanic isolation and supports CAN FD data rates up to 5 Mbps, while TCAN337DR is a non-isolated CAN FD transceiver with a different bus-fault and diagnostic feature set. The ISO1044BD is specifically listed as a 1/1 isolated half-bus transceiver in an 8-pin SOIC package. Consequently, TCAN337DR can be preferable in a local, non-isolated bus segment, but it does not provide the reinforced 5000 Vrms isolation barrier required by ISO1044BD-based designs.
When should I choose ISO1044BD over a non-isolated CAN interface?
Choose ISO1044BD when the CAN bus and host electronics use different ground references, when ground loops are possible, or when fault energy on the bus must be isolated from the controller. The integrated galvanic barrier and 5000 Vrms reinforced rating distinguish it from ordinary local CAN transceivers. Its ±58 V DC bus-fault protection and ±12 V common-mode tolerance also support demanding industrial networks. The trade-off is additional isolation-layout scrutiny, possible propagation-delay impact, and the need to follow the manufacturer’s isolation component recommendations.
Is ISO1044BD suitable for industrial CAN bus applications?
ISO1044BD is suitable for many industrial CAN bus applications because it combines CAN FD support up to 5 Mbps, ±58 V DC bus-fault protection, and ±12 V common-mode operation with reinforced galvanic isolation. These attributes fit automation, motor-control, robotics, and distributed sensor networks where bus transients or unequal ground potentials are concerns. The verified data does not state a temperature range or industrial qualification status, so those limits and any customer-specific qualification requirements must be checked in the manufacturer datasheet.
What can replace ISO1044BD?
No verified, pin-to-pin replacement for ISO1044BD was identified in the supplied cross-reference results. A replacement must match the 8-pin SOIC footprint, CAN TX and RX pin arrangement, isolation barrier, CAN FD data rate, fault protection, common-mode range, and supply requirements. The ISO1044BDR variant is a packaging-code version of the same device and is not listed because reel-code variants were excluded from the alternatives. A board redesign or a functionally similar transceiver without integrated isolation should not be treated as a drop-in replacement.
Is there a drop-in alternative to ISO1044BD from another manufacturer?
No confirmed cross-brand drop-in equivalent for ISO1044BD appears in the provided cross-reference data. The search results include generic replacement tools and comparison pages, but they do not identify a competing 8-pin SOIC device that also provides the same reinforced galvanic isolation, ±58 V DC bus-fault protection, ±12 V common-mode range, and CAN FD operation. Because pinout, timing, isolation capacitance, and bus-failure behavior must all be checked, an unverified competitor part should not be treated as a drop-in replacement.
Where to download the ISO1044BD datasheet PDF?
The official ISO1044BD datasheet PDF is available from the Texas Instruments literature server at https://www.ti.com/lit/ds/symlink/iso1044.pdf. The manufacturer product page at https://www.ti.com/product/ISO1044 also provides device information, part details, and related support resources. The verified search result identifies the document as the ISO1044 datasheet covering the isolated CAN FD transceiver family. Before schematic release, consult the complete document for supply limits, timing, isolation capacitance, layout guidance, and test conditions.
Where can I find the ISO1044BD pinout and SOIC-8 connection details?
The official pinout and SOIC-8 connection details should be taken from the manufacturer ISO1044 datasheet PDF at https://www.ti.com/lit/ds/symlink/iso1044.pdf. The supplied search results confirm an 8-pin SOIC (D) package but do not provide the complete numbered pin-name table. To avoid assigning CAN bus, supply, ground, or isolation-pin functions incorrectly, use the datasheet pin configuration and isolation recommendations. The XAIPART pinout field remains null because the verified text does not contain all eight pin names.
How should the ISO1044BD isolation barrier be laid out on a PCB?
The ISO1044BD isolation barrier must remain continuous from the logic-side ground and copper to the bus-side ground, with no traces, vias, copper pours, or components bridging the two domains. Place bus-side protection and filter components on the CAN side of the barrier, and follow the Texas Instruments datasheet for isolation-capacitor placement and creepage or clearance requirements. Keep high-voltage bus nets away from sensitive logic traces and confirm the finished-board insulation distance. The supplied data does not specify exact dimensions, so the manufacturer layout guidance controls.

بيانات مرجعية هندسية لـ ISO1044BD — المقارنة وإرشادات التصميم ومعلومات الامتثال.

دليل الاختيار

Choose ISO1044BD when the design needs CAN FD communication up to 5 Mbps across a reinforced galvanic isolation barrier. It is particularly appropriate for industrial controllers, motor drives, robotics, building automation, and distributed sensors where ground potential differences or bus faults could affect the host electronics. The ±58 V DC fault protection and ±12 V common-mode range provide useful robustness, but external surge protection may still be required at the connector. TCAN332DR and TCAN337DR are appropriate for non-isolated CAN segments and should be chosen only when the isolation barrier is implemented elsewhere. No verified drop-in replacement was identified for ISO1044BD, so changing suppliers requires verification of the exact pinout, isolation rating, timing, capacitance, fault behavior, and supply arrangement rather than relying on the SOIC-8 package alone.

المقارنة مع البدائل

المعامل هذا المنتج
Package 8-pin SOIC (D)
Brand Texas Instruments
Product Type Galvanically isolated CAN FD transceiver
Maximum Data Rate 5 Mbps
CAN Standard ISO11898-2 (2016)
DC Bus Fault Protection -58 V to +58 V
Common-Mode Voltage Range -12 V to +12 V
Isolation Voltage 5000 Vrms reinforced
CAN Bus Configuration 1/1 isolated half-bus transceiver
RoHS Status RoHS3 compliant

أبرز الفروقات

  • Integrated reinforced galvanic isolation (مقابلTCAN332DR)
  • Higher stated CAN FD data capability than a non-isolated site-list comparator (مقابلTCAN337DR)
  • Strong bus-fault and common-mode protection (مقابلISO1042BDWR)

ملاحظات التصميم

Maintain a continuous isolation barrier between the bus-side and logic-side copper, including ground, fill copper, vias, silkscreen-dependent assembly features, and placed components. Do not route signals or return currents beneath the device in a way that bridges the barrier. Use the Texas Instruments ISO1044 datasheet for the required isolation-capacitor placement, creepage, clearance, and PCB finish guidance, and verify the final dimensions against the applicable working voltage and pollution-degree requirements.

Do not assume that ±58 V DC bus-fault protection eliminates the need for external surge and ESD protection. The CAN connector and wiring can present transients beyond the transceiver’s operating limits, so use a protection network appropriate for the installation while respecting the manufacturer’s topology and component-rating guidance. Also keep bus-side protection components on the CAN side of the isolation barrier and confirm termination placement to avoid incorrect stub behavior or loss of signal margin.

CAN FD operation up to 5 Mbps requires careful routing from the controller-side TX and RX connections through the transceiver to the CANH and CANL bus pins. Keep the bus pair short, matched by geometry where practical, and separated from switching-power and high-current return paths. Confirm the complete propagation delay against the CAN FD timing budget, use the recommended bus protection network, and avoid adding long unprotected stubs because they can create reflections and reduce communication margin.

The verified excerpts do not provide the ISO1044BD supply-voltage range, supply current, or decoupling requirements, so those values must not be inferred from generic CAN transceivers. Before schematic capture, check the official manufacturer datasheet for both isolated-side supply arrangements, bypass-capacitor values, startup behavior, and power-consumption limits. Verify that the selected regulator can support the transceiver without introducing noise or droop on the logic-side rail.

معلومات الامتثال

RoHS
Compliant
REACH
Unknown
AEC-Q100
Unknown
خالٍ من الرصاص
Unknown
خالٍ من الهالوجين
Unknown
المعادن المتنازع عليها
Unknown

The verified DiGi Electronics listing identifies ISO1044BD as RoHS3 compliant. No verified information was provided for REACH, AEC-Q100 qualification, lead-free status, halogen-free status, or conflict-minerals compliance.

تم التحقق من البيانات في: 2026-10-28 — تم التحقق من البيانات وتنسيقها بواسطة فريق هندسة المكونات في XAIPART

عمليات بحث ذات صلة

ISO1044BD ISO1044BD datasheet PDF Texas Instruments ISO1044BD ISO1044BD 5 Mbps CAN FD transceiver ISO1044BD 5000 Vrms reinforced isolation ISO1044BD 8-pin SOIC ISO1044BD isolated CAN bus industrial application ISO1044BD vs TCAN332DR ISO1044BD vs TCAN337DR ISO1044BD drop-in replacement ISO1044BD price and stock where to buy ISO1044BD online ISO1044BD pinout and isolation layout

المكونات والمصطلحات ذات الصلة

Texas Instruments ISO1044BD ISO1044B ISO11898-2 (2016) CAN FD Controller Area Network galvanic isolation isolated CAN transceiver CAN interface IC interface IC semiconductor 5 Mbps data rate 5000 Vrms reinforced isolation ±58 V DC bus-fault protection ±12 V common-mode voltage SOIC-8 surface mount industrial automation electric motor drives robotics building automation distributed sensors CAN bus RoHS3
عرض سعر سريع RFQ
املأ التفاصيل الكاملة — سيرد فريق المبيعات لدينا خلال 24 ساعة
رقم القطعة الشركة المصنعة الحزمة QTY السعر المستهدف الإجمالي
✓
تم إرسال عرض السعر!

سنرد على بريدك الإلكتروني خلال 24 ساعة

1
تم إرسال طلب عرض السعر
2
تم استلام عرض السعر
3
تم تقديم الطلب
4
الدفع
5
تم الشحن
6
تم التسليم
عرض تفاصيل طلب عرض السعر