LT1007XH সারাংশ

Analog Devices LT1007XH is a single-circuit, low-noise operational amplifier specified for operation up to 200°C and supplied in a hermetic TO-5 package. It combines 10 µV offset voltage, 0.2 µV/°C offset drift, 130 dB common-mode rejection, and 130 dB power-supply rejection with monolithic noise performance of 2.5 nV/√Hz. The 1/f noise corner is 2 Hz, and 0.1 Hz-to-10 Hz noise is 60 nV peak-to-peak, making the device suitable for precision analog signal chains requiring low voltage noise and low drift.

An operational amplifier, or op amp, is a high-gain differential amplifier used to amplify, buffer, filter, compare, or control analog signals. The LT1007 belongs to the precision operational-amplifier hierarchy, where low input noise, low offset drift, high rejection, and stable operation are more important than maximum bandwidth or minimum cost. Its wide operating-temperature capability extends that precision-focused role to industrial, instrumentation, and high-temperature analog systems.

Key features include a 10 µV input offset voltage, 0.2 µV/°C input offset drift, and 130 dB common-mode rejection. The manufacturer describes a 2.5 nV/√Hz wideband noise density, a 2 Hz 1/f corner, and 60 nV peak-to-peak noise from 0.1 Hz to 10 Hz. The manufacturer datasheet also states that these devices are 100% tested at 200°C ±3°C, with normal operating-temperature specifications provided separately for the LT1007M version.

The LT1007 series was designed as a direct replacement for the OP-27 operational-amplifier family, as stated in the manufacturer datasheet. This heritage is important because it provides an established precision-amplifier upgrade path for existing instrumentation and signal-conditioning designs. The LT1007XH combines the series noise and precision characteristics with a hermetic TO-5 construction intended to support demanding thermal environments.

Typical uses include precision instrumentation, low-level sensor amplification, bridge and strain-gauge signal conditioning, laboratory measurement equipment, and industrial analog front ends. Its low-noise and low-drift characteristics are particularly valuable when the input signal is small and the useful measurement must remain stable despite temperature changes. In these applications, the amplifier is usually placed directly in front of an ADC or downstream measurement chain.

When designing with the LT1007XH, verify the exact LT1007XH electrical limits from the manufacturer datasheet rather than substituting the normal-temperature LT1007M limits. Decoupling, input-bias-current compensation, source impedance, output loading, and stability must be evaluated around the selected noise and gain conditions. The hermetic package also requires attention to lead strain, thermal expansion, and PCB soldering practices.

This page combines verified manufacturer specifications, current distributor sourcing information, same-package drop-in candidates, and practical selection guidance. It also distinguishes the uniquely tested LT1007XH temperature grade from ordinary package-code or reel-code variants, helping engineers make a replacement decision based on electrical compatibility and environmental requirements.

এর জন্য ড্রপ-ইন বিকল্প LT1007XH — একই package, pin-to-pin compatible। ভিন্ন package-এর যেসব পার্টে PCB rework প্রয়োজন সেগুলো বাদ দেওয়া হয়েছে।

LT1007AH

✅ ড্রপ-ইন ⚠️ স্পেক যাচাইকৃত নয়
📦 TO-5
Same LT1007 family and TO-5 format, but the A temperature grade differs from the XH 200°C-tested grade

📋 রেফারেন্স বিকল্প (ক্যাটালগে নেই)

LT1007CH

✅ ড্রপ-ইন ⚠️ স্পেক যাচাইকৃত নয়
Analog Devices
📦 TO-5
Single low-noise, high-speed precision operational amplifier · 1 circuit · 2.5 nV/√Hz · 4.5 nV/√Hz · 3.8 nV/√Hz · 60 nV peak-to-peak from 0.1 Hz to 10 Hz · 2 Hz · 10 µV

মূল্যের জন্য যোগাযোগ করুন

ডেটাশিট দেখুন →

LT1007UH

✅ ড্রপ-ইন ⚠️ স্পেক যাচাইকৃত নয়
📦 TO-5
Same LT1007 family and TO-5 format, but the U temperature grade differs from the XH 200°C-tested grade

📋 রেফারেন্স বিকল্প (ক্যাটালগে নেই)

OP27CHZ

✅ ড্রপ-ইন
📦 TO-5
OP-27-family precision amplifier identified by the LT1007 datasheet as directly replaceable, with separate grade and limit verification required

📋 রেফারেন্স বিকল্প (ক্যাটালগে নেই)

OP27JZ

✅ ড্রপ-ইন
📦 TO-5
OP-27-family TO-5 precision amplifier identified by the LT1007 datasheet as directly replaceable, with separate temperature-grade limits

📋 রেফারেন্স বিকল্প (ক্যাটালগে নেই)

LT1007XH সর্বোচ্চ রেটিং ও বৈদ্যুতিক বৈশিষ্ট্য

Amplifier Type Low-noise precision operational amplifier
Number of Circuits 1 circuit
Input Offset Voltage 10 µV
Input Offset Drift 0.2 µV/°C
Common-Mode Rejection 130 dB
Power-Supply Rejection 130 dB
Wideband Input Noise Density 2.5 nV/√Hz
1/f Noise Corner Frequency 2 Hz
0.1 Hz to 10 Hz Input Noise 60 nV peak-to-peak
High-Temperature Test Condition 100% tested at 200°C ±3°C
Guaranteed Parameters at Temperature 190°C ±3°C
Absolute Maximum Operating Temperature 225°C
প্যাকেজ TO-5 hermetic package
পিন সংখ্যা 8 pins
Product Classification Standard general-purpose amplifier
Legacy Compatibility Direct replacement for OP-27 series

LT1007XH to-5 hermetic package পিন কনফিগারেশন গাইড

LT1007XH (to-5 hermetic package প্যাকেজ)-এর পিন কনফিগারেশন। এই অ্যানালগ কম্পোনেন্টে ইনপুট, আউটপুট ও পাওয়ার সাপ্লাই পিন রয়েছে। অফসেট নাল, কম্পেনসেশন ও এনেবল পিন কনফিগারেশনের জন্য প্রস্তুতকারকের ডেটাশিট দেখুন। সিগন্যাল কন্ডিশনিং ও অ্যামপ্লিফায়ার সার্কিটের জন্য আদর্শ।

LT1007XH-এর জন্য to-5 hermetic package প্যাকেজ পিনআউট ডায়াগ্রাম

এর জন্য বিস্তারিত পিনআউট ডেটা পাওয়া যায়নি LT1007XH.

দেখুন ডেটাশিট সম্পূর্ণ পিন কনফিগারেশনের জন্য।

সাধারণ ব্যবহার

LT1007XH এর জন্য উপযুক্ত 6 অ্যাপ্লিকেশনs: Precision Instrumentation, Bridge and Strain-Gauge Signal Conditioning, High-Temperature Sensor Amplification, Low-Level Audio and Communication Interfaces, Laboratory Measurement Equipment, Industrial Analog Signal Conditioning.

🔧

Precision Instrumentation

The LT1007XH fits precision instrumentation where low-level differential signals must be amplified without adding excessive noise or temperature-dependent error. Its 2.5 nV/√Hz wideband input-noise density, 10 µV offset voltage, and 0.2 µV/°C offset drift establish a strong signal-to-error ratio for laboratory and industrial measurement systems. The 130 dB common-mode rejection and 130 dB power-supply rejection also help suppress interference coupled into sensitive inputs. It is especially useful when the amplifier operates near the high-temperature capability for which the LT1007X devices are 100% tested at 200°C ±3°C.

🏭

Bridge and Strain-Gauge Signal Conditioning

The LT1007XH is appropriate for bridge and strain-gauge front ends because small sensor signals require low voltage noise, low offset drift, and high common-mode rejection. The 60 nV peak-to-peak noise from 0.1 Hz to 10 Hz supports low-frequency measurement, while the 0.2 µV/°C drift limits temperature-related baseline movement. Its 130 dB common-mode rejection can reduce errors from common-mode voltage on the sensor lines. The amplifier should be evaluated with the actual bridge impedance, excitation method, cable length, and grounding configuration because those external factors materially affect total measurement error.

🏭

High-Temperature Sensor Amplification

The LT1007XH supports high-temperature sensor amplification because the manufacturer tests LT1007X devices at 200°C ±3°C and guarantees specified parameters at 190°C ±3°C. This capability is relevant to equipment operating near industrial ovens, furnaces, engines, or thermally exposed sensors where a conventional commercial amplifier may lose accuracy or fail. The amplifier’s 10 µV offset and 0.2 µV/°C drift remain important because temperature changes are intrinsic to the application. Designers must still distinguish guaranteed operating parameters from the 225°C absolute maximum operating temperature and should verify thermal stability in the completed assembly.

🎧

Low-Level Audio and Communication Interfaces

The LT1007XH can amplify low-level signals in audio and communication equipment when low voltage noise is more important than switching-converter efficiency or very wide bandwidth. Its 2.5 nV/√Hz noise density and 2 Hz 1/f corner reduce amplifier-added noise over the measured signal band, while 130 dB common-mode rejection helps reject common-mode interference. The TO-5 package is less compact than modern surface-mount packages, making the LT1007XH more relevant to established precision, aerospace-style, or high-reliability equipment than to compact consumer designs. Input and output loading must be checked against the complete gain and bandwidth design.

📺

Laboratory Measurement Equipment

The LT1007XH is suitable for laboratory measurement equipment requiring a stable, low-noise amplifier rather than a general-purpose op amp. The combination of 10 µV offset voltage, 0.2 µV/°C drift, 130 dB common-mode rejection, and 60 nV peak-to-peak low-frequency noise supports accurate conditioning of small measurement signals. Its ability to operate in elevated-temperature conditions also supports specialized environmental and thermal test chambers. When replacing an earlier OP-27 design, engineers should verify the power-supply range, stability at the intended closed-loop gain, output swing, and the exact TO-5 lead configuration before production use.

🌐

Industrial Analog Signal Conditioning

The LT1007XH can serve in industrial analog signal-conditioning modules that process small sensor outputs in electrically noisy environments. Its 130 dB common-mode rejection and 130 dB power-supply rejection improve tolerance of unwanted common-mode and supply-related disturbances, while low noise and drift preserve measurement integrity. The hermetic TO-5 construction and 200°C test capability are useful in elevated-temperature equipment, although the complete enclosure, connector system, and thermal path determine practical reliability. Protection networks, input filtering, and grounding should be designed around the actual source impedance and operating bandwidth.

সুপারিশকৃত পণ্যের সারসংক্ষেপ

LT1007AH Same-family precision amplifier in the hermetic TO-5 format ব্যবহৃত হয়: Precision Instrumentation, High-Temperature Sensor Amplification, Laboratory Measurement Equipment OP27CHZ OP-27-family precision amplifier identified as directly replaceable ব্যবহৃত হয়: Precision Instrumentation, Low-Level Audio and Communication Interfaces LT1007CH Analog Devices ব্যবহৃত হয়: Bridge and Strain-Gauge Signal Conditioning, Laboratory Measurement Equipment, Industrial Analog Signal Conditioning LT1007UH Same-family precision amplifier with a different orderable temperature grade ব্যবহৃত হয়: Bridge and Strain-Gauge Signal Conditioning, Low-Level Audio and Communication Interfaces OP27JZ OP-27-family precision alternative requiring temperature-limit verification ব্যবহৃত হয়: High-Temperature Sensor Amplification, Industrial Analog Signal Conditioning
What are the key specifications of LT1007XH that engineers should know?
The LT1007XH is a single low-noise precision op amp with 10 µV input offset voltage, 0.2 µV/°C offset drift, 130 dB common-mode rejection, and 130 dB power-supply rejection. According to the Analog Devices product page and manufacturer datasheet, its wideband input noise is 2.5 nV/√Hz, its 1/f corner is 2 Hz, and its 0.1 Hz-to-10 Hz noise is 60 nV peak-to-peak. It is packaged in TO-5 and 100% tested at 200°C ±3°C.
Where can I download the LT1007XH datasheet PDF?
The official LT1007X datasheet PDF is available from Analog Devices at the manufacturer datasheet link provided on this page. The document identifies the part as a low-noise 200°C operational amplifier and includes pin configuration, absolute maximum operating temperature, precision specifications over an extended temperature range, and compatibility with the OP-27 series. Download the LT1007X datasheet rather than using the LT1007M document when the LT1007XH high-temperature grade is required.
What is the input noise of the LT1007XH?
The LT1007XH has a wideband input-noise density of 2.5 nV/√Hz, according to the Analog Devices manufacturer datasheet. The same source specifies a 1/f noise corner frequency of 2 Hz and 60 nV peak-to-peak noise from 0.1 Hz to 10 Hz. These figures make the device appropriate for low-level instrumentation where source resistance, amplifier noise, and temperature drift determine the smallest signal that can be measured reliably.
Is the LT1007XH suitable for 200°C operation?
Yes, the LT1007XH is specifically qualified and tested for elevated-temperature operation. The manufacturer datasheet states that devices are 100% tested at 200°C ±3°C to the applicable limits and that parameters are guaranteed at 190°C ±3°C because they change rapidly with temperature. The listed absolute maximum operating temperature is 225°C, but absolute maximum ratings are not operating specifications.
What can replace the LT1007XH on the same board?
The closest same-brand drop-in candidates identified from the verified manufacturer material are hermetic TO-5 members of the LT1007 family, while the LT1007 datasheet identifies the series as a direct replacement for the OP-27 series. Replacement still requires checking the exact operating-temperature grade, supply range, offset limits, and pin configuration. The listed candidates share the TO-5 format, but their temperature guarantees and orderable suffixes are not necessarily identical to LT1007XH.
Is LT1007XH the same as an OP-27 replacement?
The LT1007XH belongs to a series that the manufacturer explicitly describes as a direct replacement for the OP-27 series. Its characterized precision includes 10 µV offset voltage and 0.2 µV/°C offset drift, together with 2.5 nV/√Hz wideband noise. An OP-27-family device is therefore a relevant alternative, but engineers should still verify pinout, supply voltage, temperature grade, and exact electrical limits before substitution.
Where can I buy LT1007XH online?
The LT1007XH can be sourced from major authorized distributors, including DigiKey and Mouser. The verified DigiKey listing identifies Analog Devices as the manufacturer, describes a one-circuit TO-5 standard general-purpose amplifier, and reports that the part ships today. Current inventory, lot traceability, and the final delivered price should be confirmed with the distributor at the time of order because the provided web record does not contain numeric price or stock-quantity values.
What is the price of LT1007XH?
A verified numeric price for LT1007XH was not present in the supplied distributor records, so no distributor price is asserted here. Both DigiKey and Mouser provide live product pages where the current quantity-1 price and negotiated volume pricing can be checked. Pricing must therefore be confirmed as of 2026-10-30, and changes in availability, manufacturer inventory, or currency can affect the final purchase cost.
What is the lead time for LT1007XH?
The lead time cannot be stated numerically from the supplied data. The verified DigiKey result says “buy now, ships today,” which indicates immediate availability at the time of that search, but a live distributor quote is required for a guaranteed delivery date. Because this is a hermetic, high-temperature specialty amplifier, production and inventory status should be confirmed before making a large-volume purchasing commitment.
Is LT1007XH in stock?
The verified DigiKey page reports that LT1007XH ships today, indicating availability at the time of the search on 2026-10-30. Inventory can change rapidly and may vary by package, manufacturer lot, and distributor quantity. The Mouser and DigiKey listings should be checked immediately before purchase to confirm current stock, authorized-distributor status, and the desired quantity.
LT1007XH vs LT1007M: which operating-temperature version should I choose?
Choose LT1007XH when the circuit must operate in an extended high-temperature environment. The manufacturer datasheet states that LT1007X devices are 100% tested at 200°C ±3°C, guaranteed at 190°C ±3°C, and have a listed absolute maximum operating temperature of 225°C. It also states that normal operating-temperature specifications are available in the LT1007M datasheet, so LT1007M should be selected for ordinary-temperature requirements.
When should I choose LT1007XH over another low-noise op amp?
Choose LT1007XH when low noise, low offset drift, high rejection, and operation around 200°C are all important. Its 2.5 nV/√Hz wideband noise, 10 µV offset voltage, 0.2 µV/°C drift, and 130 dB common-mode rejection make it suitable for demanding precision instrumentation. A general-purpose amplifier may cost less, but it may not provide the same high-temperature qualification or low-noise precision.
Is LT1007XH suitable for precision instrumentation and sensor signals?
Yes, the LT1007XH is well suited to precision instrumentation because it combines 2.5 nV/√Hz wideband noise with 10 µV offset voltage and 0.2 µV/°C drift. These characteristics help preserve small differential signals in bridge, strain-gauge, and measurement front ends. The source impedance must be considered because the selected source resistance affects total input noise and bias-current error.
What pinout information is available for LT1007XH?
The official Analog Devices LT1007X datasheet contains the authoritative pin configuration, but the supplied web excerpts do not reproduce every terminal name or number. Because the available text does not permit a complete, verified pin-by-pin transcription, the pinout field is intentionally null rather than guessed. Download the manufacturer PDF and compare its pin configuration with the physical board before replacing or substituting the amplifier.
Is the LT1007XH RoHS and REACH compliant?
The supplied manufacturer and distributor excerpts do not explicitly state the LT1007XH RoHS, REACH, lead-free, or halogen-free status, so those compliance fields remain unknown. Compliance should be confirmed using the current Analog Devices product declaration, material-declaration documentation, or the distributor’s regulatory records for the exact orderable MPN. The high operating-temperature rating by itself is not evidence of environmental compliance.

এর জন্য ইঞ্জিনিয়ারিং রেফারেন্স ডেটা LT1007XH — তুলনা, ডিজাইন গাইডেন্স এবং কমপ্লায়েন্স তথ্য।

নির্বাচন গাইড

Choose the LT1007XH when the design needs a low-noise precision amplifier that can operate in an elevated-temperature environment. Its documented 2.5 nV/√Hz noise, 10 µV offset, 0.2 µV/°C drift, 130 dB common-mode rejection, 130 dB power-supply rejection, and 200°C production testing make it particularly suitable for precision instrumentation and high-temperature sensing. Select LT1007AH, LT1007CH, or LT1007UH only after confirming that their orderable temperature grade provides the required operating limits. Consider an OP27CHZ or OP27JZ when its individual noise, drift, temperature, supply, and stability specifications meet the design and the board can accept the replacement; the LT1007 datasheet supports OP-27-series replacement intent but does not make every OP-27 code electrically identical. For any substitution, verify the pin configuration, supply range, input common-mode range, output swing, gain bandwidth, and compensation requirements against the manufacturer datasheets.

বিকল্পের সাথে তুলনা

পারামিটার এই পণ্য LT1007AH LT1007CH LT1007UH OP27CHZ OP27JZ
Package TO-5 hermetic package, 8 pins TO-5 hermetic package, 8 pins TO-5 hermetic package, 8 pins TO-5 hermetic package, 8 pins TO-5 hermetic package, 8 pins TO-5 hermetic package, 8 pins
Brand Analog Devices Analog Devices Analog Devices Analog Devices Analog Devices Analog Devices
Product Family LT1007 precision low-noise operational amplifier LT1007 precision low-noise operational amplifier LT1007 precision low-noise operational amplifier LT1007 precision low-noise operational amplifier OP-27 precision operational amplifier OP-27 precision operational amplifier
Number of Circuits 1 circuit 1 circuit 1 circuit 1 circuit 1 circuit 1 circuit

মূল পার্থক্যসমূহ

  • Explicit 200°C production-test coverage (বনামLT1007AH)
  • High rejection with low-noise precision (বনামLT1007CH)
  • Documented elevated-temperature qualification (বনামOP27CHZ)
  • Low drift for changing thermal environments (বনামOP27JZ)

ডিজাইন নোট

Use the LT1007X datasheet’s guaranteed limits at 190°C ±3°C when designing around elevated-temperature operation; the 225°C value is an absolute maximum and is not a recommended operating point. Because parameters change rapidly with temperature, calculate worst-case offset drift from the specified 0.2 µV/°C and include the complete thermal environment, lead-frame heat path, and adjacent heat sources. The 200°C ±3°C test condition is a production test condition, not permission to operate continuously at the test ceiling.

Do not replace LT1007XH with LT1007M without reviewing the separate operating-temperature specifications. The manufacturer explicitly directs users to the LT1007M datasheet for normal operating-temperature limits, while LT1007X devices receive elevated-temperature testing. Also verify the exact TO-5 lead configuration and the alternative’s offset, drift, noise, rejection, supply-voltage, and output-swing limits. Package match alone does not prove that every electrical limit is identical.

Place the amplifier’s input and output paths away from switching nodes, high-current returns, and long parallel traces that can capacitively couple interference into the low-noise input stage. Use short ground returns and a quiet analog ground strategy appropriate to the system. Include input-referenced compensation or source-resistance analysis because the 2.5 nV/√Hz voltage-noise figure does not include all noise introduced by the source impedance or bias current.

Do not treat the OP-27-family compatibility statement as permission to substitute any OP-27 orderable code. Verify temperature grade, supply range, offset limits, drift, gain bandwidth, slew rate, output swing, input common-mode range, and the physical pinout against both datasheets. The verified excerpts establish family-level replacement intent but do not provide every alternative’s numeric limits, so those limits must be confirmed in the applicable manufacturer documentation.

কমপ্লায়েন্স তথ্য

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
লিড ফ্রি
Unknown
হ্যালোজেন ফ্রি
Unknown
কনফ্লিক্ট মিনারেলস
Unknown

The supplied Analog Devices and distributor excerpts do not explicitly state RoHS, REACH, lead-free, halogen-free, or conflict-minerals status for LT1007XH. AEC-Q100 is treated as not applicable because this is an Analog Devices precision operational amplifier, not an identified automotive-qualified product.

ডেটা যাচাই করা হয়েছে: 2026-10-30 — ডেটা XAIPART-এর কম্পোনেন্ট ইঞ্জিনিয়ারিং টিম দ্বারা যাচাই ও কিউরেট করা হয়েছে

সম্পর্কিত অনুসন্ধান

LT1007XH LT1007XH datasheet PDF Analog Devices LT1007XH LT1007XH 200°C operational amplifier LT1007XH 2.5 nV/√Hz noise LT1007XH TO-5 pinout LT1007XH precision instrumentation LT1007XH high temperature sensor amplifier LT1007XH vs OP27 LT1007XH drop-in replacement LT1007XH price buy LT1007XH online what can replace LT1007XH

সম্পর্কিত কম্পোনেন্ট ও শর্তাবলী

Analog Devices Linear Technology LT1007XH LT1007X LT1007M LT1007AH LT1007CH LT1007UH OP27CHZ OP27JZ operational amplifier op amp precision operational amplifier low-noise amplifier analog integrated circuit voltage noise density 2.5 nV/√Hz input offset voltage 10 µV offset voltage 0.2 µV/°C offset drift common-mode rejection power-supply rejection TO-5 hermetic package instrumentation amplifier sensor signal conditioning 200°C operational amplifier
তাৎক্ষণিক বিলওয়াছে রেকোজিউইট
সম্পূর্ণ বিবরণ পূরণ করুন — আমাদের সেলস টিম 24 ঘণ্টার মধ্যে উত্তর দেবে
পার্ট নম্বর উৎপাদক প্যাকেজ QTY লক্ষ্যমূল্য প্রসারিত
✓
বিল প্রস্তুত করা হয়েছে!

আমরা ২৪ ঘণ্টার মধ্যে আপনার ইমেইলে প্রত্যুত্তর দেব

1
RFQ জমা হয়েছে
2
কোটেশন পাওয়া গেছে
3
অর্ডার দেওয়া হয়েছে
4
পেমেন্ট
5
শিপ করা হয়েছে
6
ডেলিভারি হয়েছে
RFQ বিবরণ দেখুন