Analog Devices

MAX378EWG+ - 8:1 Fault-Protected Multiplexer | Analog Devices

MPN: MAX378EWG+ ✓ সক্রিয়
3.5 kOhm Rds(on) 24-pin SOIC Package
সর্বনিম্ন অর্ডার পরিমাণ: 1 |

MAX378EWG+ সারাংশ

The Analog Devices MAX378EWG+ is an 8-channel, single-ended 1-of-8 multiplexer with a specified on-resistance of 3.5 kOhm, fault protection, and a 24-pin SOIC package. The device is designed for routing one of eight analog inputs to a common output while providing protection when supply voltages are inadvertently removed from a powered system. The MAX378 uses a series N-channel, P-channel, and N-channel switch arrangement that supports fault-protected operation in demanding measurement and control circuits.

A multiplexer is an analog switch that connects multiple signal sources to one destination. In the broader hierarchy of electronic components, the MAX378EWG+ is an analog multiplexer, an analog switch, an interface IC, and ultimately a semiconductor. Its eight-to-one configuration reduces the number of external signal lines needed when several sensors, voltage sources, or measurement channels must be evaluated by one downstream converter. The fault-protected architecture is particularly useful when an input may remain energized while the device's own supply rails are off.

The manufacturer identifies the MAX378 as an 8-channel, high-voltage, fault-protected multiplexer and lists it in production. Its principal specifications include an 8:1 configuration, one multiplexer circuit, 3.5 kOhm on-resistance, and a 24-SOIC package. The MAX378EWG+ ordering code is listed by distributors as a 24-pin SOIC analog switch or multiplexer. The similarly named MAX379 is a different 4-channel differential multiplexer and therefore is not an interchangeable functional substitute for the single-ended MAX378.

The N-channel, P-channel, and N-channel topology distinguishes this device from a basic eight-channel analog multiplexer. According to the Analog Devices MAX378 product page, the fault-protection structure causes all mux channels to turn off if the power supplies are inadvertently turned off while input voltages remain applied. This behavior limits unintended signal paths during an abnormal power sequence and is valuable in equipment where external sources can outlive the local control electronics.

Typical uses include battery-powered instrumentation, industrial test equipment, data acquisition, automated measurement systems, and analog sensor interfaces. The 8:1 organization is useful when one analog-to-digital converter or measurement front end must interrogate multiple inputs without requiring a separate switch for every channel. Engineers should also account for the relatively high 3.5 kOhm on-resistance when designing sensors that require low source impedance or when calculating the resulting signal attenuation.

For layout and protection, place the multiplexer near the routed analog signals, keep the selected-channel traces compact, and provide a defined return path for every switched input. Review the manufacturer's datasheet pin description, absolute maximum ratings, and typical application circuit before connecting high-voltage sources. The fault-protection feature should not be interpreted as permission to exceed those ratings or as a substitute for external surge protection.

This product page consolidates the manufacturer identity, package, multiplexing configuration, fault-protection architecture, ordering information, sourcing guidance, and design considerations into an engineering-focused reference. It also distinguishes true drop-in alternatives from related devices whose channel count, signal architecture, or package implementation differs, helping PCB designers avoid substitutions that require schematic or layout changes.

এর জন্য ড্রপ-ইন বিকল্প MAX378EWG+ — একই package, pin-to-pin compatible। ভিন্ন package-এর যেসব পার্টে PCB rework প্রয়োজন সেগুলো বাদ দেওয়া হয়েছে।

MAX378EWG

✅ ড্রপ-ইন
📦 24-SOIC
Trailing plus suffix differs by 0 V and no quantified electrical difference appears in the listings; both are specified as 8:1, 3.5 kOhm, 24-SOIC devices

📋 রেফারেন্স বিকল্প (ক্যাটালগে নেই)

MAX378EWG+ বিশেষণ

Multiplexer Configuration 8:1 (1-of-8)
Number of Channels 8 channels
Number of Circuits 1 circuit
Signal Type Single-ended
On-Resistance 3.5 kOhm
Fault Protection High-voltage fault-protected operation
Switch Architecture Series N-channel/P-channel/N-channel structure
Power-Off Protection Behavior All channels turn off when supplies are off while input voltages remain applied
Package Type 24-pin SOIC
Terminal Count 24 terminals
মাউন্টিং টাইপ Surface mount
Package Shape Rectangular
Temperature Grade Industrial
Production Status Production

MAX378EWG+ rectangular পিন কনফিগারেশন গাইড

MAX378EWG+ (rectangular প্যাকেজ)-এর পিন কনফিগারেশন। পিন নম্বরিং, ফাংশন এবং সংযোগ ডায়াগ্রাম প্রস্তুতকারকের ডেটাশিটে সংজ্ঞায়িত করা আছে। সঠিক ফুটপ্রিন্ট এবং সোল্ডারিং নির্দেশিকার জন্য এটি দেখুন।

MAX378EWG+-এর জন্য rectangular প্যাকেজ পিনআউট ডায়াগ্রাম

এর জন্য বিস্তারিত পিনআউট ডেটা পাওয়া যায়নি MAX378EWG+.

দেখুন ডেটাশিট সম্পূর্ণ পিন কনফিগারেশনের জন্য।

সাধারণ ব্যবহার

MAX378EWG+ এর জন্য উপযুক্ত 6 অ্যাপ্লিকেশনs: Battery-Powered Data Acquisition, Industrial Sensor Multiplexing, Automated Test Equipment, High-Voltage Measurement Interface, Analog Control Signal Multiplexing, Instrumentation Signal Conditioning.

🔋

Battery-Powered Data Acquisition

The MAX378EWG+ fits battery-powered data-acquisition equipment that must measure several analog inputs through one downstream converter. Its eight-channel, single-ended 1-of-8 organization reduces the number of analog switch packages needed for channel selection, while the 3.5 kOhm on-resistance establishes the maximum source impedance that should be considered in the signal path. The fault-protected N-channel, P-channel, and N-channel architecture is particularly relevant when sensor inputs can remain energized after the local supply has been removed. A practical implementation uses the common mux output to feed the measurement front end and selects one of eight inputs with the control interface described in the manufacturer datasheet.

🏭

Industrial Sensor Multiplexing

The MAX378EWG+ is suitable for industrial measurement systems that combine multiple analog sensors onto one processing channel. Its eight-to-one routing reduces wiring complexity when monitoring several pressure, temperature, or process-control signals, and its industrial temperature grade supports non-consumer equipment designs. The primary engineering trade-off is the specified 3.5 kOhm on-resistance, which forms a divider with sensor and input-network impedance. Account for that attenuation at the design stage and compare it with the measurement front-end input impedance. The fault-protection behavior also helps prevent unintended conduction during abnormal shutdown sequences when external inputs remain powered.

🧪

Automated Test Equipment

The MAX378EWG+ can route one of eight test signals to a shared measurement amplifier or converter in automated test equipment. The single-ended 1-of-8 architecture provides a straightforward way to scan DUT nodes without duplicating the measurement chain eight times. Because the device is specified at 3.5 kOhm on-resistance, high-accuracy measurements should include an error budget for source resistance, switch resistance, leakage, and the input impedance of the downstream instrument. Its fault-protected topology is useful in systems where test points may remain energized after the tester enters shutdown or standby, although external protection remains necessary for voltages beyond the published limits.

⚡

High-Voltage Measurement Interface

The MAX378EWG+ fits high-voltage measurement interfaces that require controlled analog routing and protection against power-sequencing faults. Analog Devices specifically describes the MAX378 as a high-voltage, fault-protected multiplexer, and its series N-channel, P-channel, and N-channel structure turns the channels off if the supplies are removed while input voltages remain applied. This makes the device useful in instruments where sensors or test fixtures can outlive the local electronics. The switch must still be operated only within its absolute maximum ratings, and the 3.5 kOhm on-resistance must be included in the sensor-to-converter signal calculation.

🎛️

Analog Control Signal Multiplexing

The MAX378EWG+ can consolidate eight analog control signals for a single actuator or signal-conditioning path. Its eight-to-one configuration reduces the number of direct analog connections to a downstream controller while preserving individual channel selection through the device's control interface. Engineers should avoid using the 3.5 kOhm switch resistance as an ideal short when driving high-current loads; instead, treat the mux as a voltage-routing element with a specified resistance and check the resulting voltage drop. The fault-protected design adds useful control during unexpected supply removal, but system-level shutdown logic and external clamps may still be required.

📊

Instrumentation Signal Conditioning

The MAX378EWG+ is applicable to instrumentation front ends that must select among multiple sensor outputs before amplification. Routing eight channels through one package can conserve board area compared with separate single-channel switches, while the common output simplifies the connection to the next gain or conversion stage. Signal integrity planning must account for the 3.5 kOhm on-resistance, the impedance of the selected sensor, and parasitic capacitance introduced by routed traces. Keeping the mux close to the source and output circuitry reduces switching transients and coupling from adjacent digital controls. Follow the manufacturer's pin assignments and recommended decoupling arrangement for predictable operation.

What is the MAX378EWG+?
The MAX378EWG+ is an 8-channel, single-ended 1-of-8 fault-protected analog multiplexer with 3.5 kOhm on-resistance in a 24-pin SOIC package. Analog Devices describes the MAX378 family as a high-voltage, fault-protected multiplexer using a series N-channel, P-channel, and N-channel structure. It routes one of eight inputs to a common output while limiting unintended conduction when the device is unpowered but external inputs remain energized.
What are the key specifications of MAX378EWG+?
The MAX378EWG+ provides an 8:1 mux configuration, eight single-ended channels, 3.5 kOhm on-resistance, fault-protected switching, and a 24-pin SOIC package. According to the Analog Devices MAX378 product page, the part is in production. The N-channel, P-channel, and N-channel structure is specifically designed to improve protection when supply voltages are inadvertently turned off while voltages remain present on the mux inputs.
Where can I download the MAX378EWG+ datasheet PDF?
The official MAX378 datasheet is available through the Analog Devices product page at https://www.analog.com/en/products/max378.html. The page identifies the device as an 8-channel, high-voltage, fault-protected multiplexer and provides the manufacturer data sheet and product documentation. For board-level implementation, use the manufacturer's pin-description table, absolute maximum ratings, electrical characteristics, and typical application circuit rather than relying on distributor summaries.
Where can I find the MAX378EWG+ pinout?
The MAX378EWG+ pinout is contained in the pin-description section of the Analog Devices MAX378 manufacturer datasheet. The distributor listings identify the device as a 24-pin SOIC, but they do not reproduce the individual terminal names. Use the datasheet pin table to assign the eight inputs, common output, control terminals, enable functions, and supply pins before laying out a PCB or checking a replacement.
How does the MAX378EWG+ fault-protection mechanism work?
The MAX378EWG+ uses a series N-channel, P-channel, and N-channel structure to provide fault protection. According to the Analog Devices MAX378 product page, all channels turn off if the power supplies are inadvertently turned off while input voltages remain applied. This behavior helps prevent unintended signal paths during abnormal power conditions, but it does not replace external surge protection or permit operation beyond the datasheet ratings.
When should I choose MAX378EWG+ instead of MAX379?
Choose MAX378EWG+ when the design requires an eight-channel, single-ended 1-of-8 multiplexer. The MAX379 is described by Analog Devices as a four-channel differential 2-of-8 multiplexer, so it has a different signal architecture and is not a direct drop-in replacement for MAX378EWG+. Although both belong to the MAX378/MAX379 family and provide fault-protected multiplexing, their channel counts, routing requirements, and application interfaces differ.
What is the difference between MAX378EWG+ and MAX378EWG?
The MAX378EWG+ and MAX378EWG listings identify the same 8:1, 3.5 kOhm, 24-SOIC MAX378 configuration, while the exact MPNs differ by the trailing plus sign. The distributor excerpts do not quantify an electrical difference between those two ordering codes, so the manufacturer ordering information should determine which suffix is approved for a new design. The MAX378EWG is the only directly identified related MPN in the available cross-reference results.
Can MAX378EWG+ replace MAX378EWG without PCB changes?
MAX378EWG and MAX378EWG+ are listed with the same 8:1 configuration, 3.5 kOhm on-resistance, and 24-SOIC package, making the base MAX378EWG the only identified drop-in candidate in the available results. Before substituting, compare the exact manufacturer ordering information, absolute maximum ratings, temperature grade, and marking requirements. The trailing plus character is not a packaging-only reel-code change and should be checked against the manufacturer ordering guide.
What can replace MAX378EWG+ on the same PCB?
The only verified same-package replacement candidate in the available cross-reference results is MAX378EWG, which is also identified as an 8:1, 3.5 kOhm, 24-SOIC device. No five-part drop-in set can be substantiated from the available manufacturer and distributor pages. The MAX379 is not a drop-in replacement because it is a four-channel differential multiplexer, and generic cross-reference tools do not establish pin and parametric compatibility without detailed part-level records.
Is MAX378EWG+ suitable for high-voltage measurement systems?
The MAX378EWG+ is specifically described by Analog Devices as a high-voltage, fault-protected multiplexer, making it suitable for suitable high-voltage measurement interfaces when the applied signals remain within the datasheet limits. Its fault-protection architecture helps control unintended paths during power-loss conditions. The 3.5 kOhm on-resistance may still attenuate high-impedance sensor signals, and external clamping may be required for voltages exceeding the device's absolute maximum ratings.
Where can I buy MAX378EWG+ and check its price?
The MAX378EWG+ can be requested through the Request a Quote form on this page, where the current commercial terms and availability can be addressed with XAIPART. The manufacturer and distributor listings identify the part as an 8-channel, fault-protected multiplexer in a 24-SOIC package. Because commercial terms can change, use the quote form rather than relying on an outdated listing snapshot.
What is the lead time for MAX378EWG+?
The current lead time for MAX378EWG+ should be confirmed through the Request a Quote form on this page. The Analog Devices product page identifies the MAX378 family as being in production, while distributor search results indicate that the exact ordering code has been listed for sale. Production status does not by itself guarantee a particular lot quantity, delivery schedule, or current stock level.
Is MAX378EWG+ in stock?
Current inventory for MAX378EWG+ should be confirmed through the Request a Quote form on this page. The available distributor records include an in-stock listing for the exact MPN and a manufacturer page identifying the family as production, but inventory changes by channel, lot, and region. Use the quote form to obtain the current availability for the required package and shipment destination.
Is MAX378EWG+ RoHS compliant?
The RoHS status of MAX378EWG+ cannot be conclusively stated from the available product-page and distributor excerpts. The trailing plus sign is part of the ordering code, but its exact regulatory meaning should be confirmed in the manufacturer's ordering information or material declaration. Review the Analog Devices product documentation before using the component in a RoHS-controlled assembly.
How should MAX378EWG+ be laid out for analog signals?
Place the MAX378EWG+ close to the source and destination analog signals, and route each selected channel with a short, guarded trace to reduce parasitic capacitance and pickup. Provide a continuous ground reference, keep the common output route away from fast digital lines, and follow the manufacturer's typical application layout for decoupling and protection. Because the on-resistance is 3.5 kOhm, calculate source impedance and channel attenuation rather than treating the switch as nearly lossless.

এর জন্য ইঞ্জিনিয়ারিং রেফারেন্স ডেটা MAX378EWG+ — তুলনা, ডিজাইন গাইডেন্স এবং কমপ্লায়েন্স তথ্য।

নির্বাচন গাইড

Choose the MAX378EWG+ when the design needs an eight-channel, single-ended 1-of-8 multiplexer with high-voltage fault protection in a 24-SOIC package. It is particularly appropriate when external inputs may remain energized during local power loss and when one common measurement or control path must serve eight analog sources. Evaluate the 3.5 kOhm on-resistance carefully because it can produce meaningful attenuation with high-impedance sensors. MAX378EWG is the only same-package related MPN identified in the available listings, but its suffix, regulatory status, and ordering-code requirements should be checked before substitution. Do not use MAX379 as a drop-in choice: it is a four-channel differential multiplexer with a different routing architecture. For designs needing lower switch resistance, lower leakage, different logic levels, or a different package, the MAX378 family does not provide a qualified substitute and a separate component selection is required.

বিকল্পের সাথে তুলনা

পারামিটার এই পণ্য MAX378EWG
Brand Analog Devices Analog Devices
Package 24-SOIC 24-SOIC - same
Multiplexer Configuration 8:1 8:1 - same
Number of Channels 8 channels 8 channels - same
On-Resistance 3.5 kOhm 3.5 kOhm - same

মূল পার্থক্যসমূহ

  • Eight-to-one single-ended routing in one package (বনামMAX378EWG)
  • Fault-protected high-voltage architecture (বনামMAX378EWG)
  • Single-ended versus differential family distinction (বনামMAX379)

ডিজাইন নোট

Place the MAX378EWG+ close to the selected analog sources and the common output to minimize trace capacitance and susceptibility to coupling from control signals. Keep the switched-node routes short, provide a continuous ground reference beneath the analog path, and avoid routing them parallel to long digital buses. The manufacturer's pin-description table and typical application layout should be used for the final connection pattern.

Include the specified 3.5 kOhm on-resistance when calculating attenuation from a high-impedance sensor. The divider formed by switch resistance and downstream input impedance can create measurable gain error, and the error becomes more important as sensor impedance rises. Also account for leakage and off-channel behavior when defining the required measurement accuracy rather than treating the switch as an ideal conductor.

Do not assume that fault protection permits operation beyond the MAX378EWG+ absolute maximum ratings. External inputs can remain energized after local power is removed, so confirm the applicable voltage, current, and temperature limits in the manufacturer datasheet. Add external clamping or surge protection where the system can expose inputs to transients outside those limits.

Follow the manufacturer's decoupling and supply recommendations for both normal operation and shutdown behavior. Pay particular attention to power-off fault conditions in which an input source remains powered while the mux supply rails are inactive. Confirm the actual fault current and leakage in the operating state through the datasheet rather than relying on the generic fault-protection description.

কমপ্লায়েন্স তথ্য

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
লিড ফ্রি
Unknown
হ্যালোজেন ফ্রি
Unknown
কনফ্লিক্ট মিনারেলস
Unknown

The available manufacturer and distributor excerpts do not explicitly state RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status. The trailing plus character in the ordering code should not be interpreted as proof of a specific compliance declaration without manufacturer documentation.

ডেটা যাচাই করা হয়েছে: 2026-11-14 — ডেটা XAIPART-এর কম্পোনেন্ট ইঞ্জিনিয়ারিং টিম দ্বারা যাচাই ও কিউরেট করা হয়েছে

সম্পর্কিত অনুসন্ধান

MAX378EWG+ MAX378EWG+ datasheet MAX378EWG+ datasheet pdf MAX378EWG+ pinout MAX378EWG+ specifications MAX378EWG+ equivalent MAX378EWG+ replacement MAX378EWG+ drop-in replacement MAX378EWG+ vs MAX378EWG MAX378EWG+ application circuit MAX378EWG+ 24-SOIC Analog Devices MAX378EWG+ MAX378EWG+ price MAX378EWG+ stock

সম্পর্কিত কম্পোনেন্ট ও শর্তাবলী

Analog Devices MAX378EWG+ MAX378EWG MAX379 MAX378 MAX379 family analog multiplexer analog switch interface IC semiconductor 8:1 mux 1-of-8 multiplexer single-ended multiplexer differential multiplexer fault protection high-voltage multiplexer N-channel switch P-channel switch on-resistance 3.5 kOhm 24-SOIC SOIC package family surface mount data acquisition industrial instrumentation
তাৎক্ষণিক বিলওয়াছে রেকোজিউইট
সম্পূর্ণ বিবরণ পূরণ করুন — আমাদের সেলস টিম 24 ঘণ্টার মধ্যে উত্তর দেবে
পার্ট নম্বর উৎপাদক প্যাকেজ QTY লক্ষ্যমূল্য প্রসারিত
✓
বিল প্রস্তুত করা হয়েছে!

আমরা ২৪ ঘণ্টার মধ্যে আপনার ইমেইলে প্রত্যুত্তর দেব

1
RFQ জমা হয়েছে
2
কোটেশন পাওয়া গেছে
3
অর্ডার দেওয়া হয়েছে
4
পেমেন্ট
5
শিপ করা হয়েছে
6
ডেলিভারি হয়েছে
RFQ বিবরণ দেখুন