OPA2277PA - 10uV Precision Dual Op Amp | Texas Instruments
MPN: OPA2277PA ✓ সক্রিয়OPA2277PA সারাংশ
An operational amplifier is an analog integrated circuit that amplifies the voltage difference between its non-inverting and inverting inputs. High-precision operational amplifiers form part of the precision analog amplifier hierarchy and are used where offset error, drift, bias current, and common-mode performance affect measurement accuracy. The OPA2277PA is specifically designed to replace the industry-standard OP-177 while offering improved noise, wider output-voltage swing, twice the speed, and lower quiescent current according to the Texas Instruments datasheet.
The principal benefits of the OPA2277PA include its 10 uV maximum input offset voltage and 0.1 uV/°C maximum offset-voltage drift. These characteristics make the dual amplifier suitable for precision instrumentation, sensor interfaces, low-level signal conditioning, and buffered references. Its 1 MHz gain-bandwidth product supports signal bandwidths around a few hundred kilohertz depending on closed-loop gain, while its operating range of 2 V to 18 V accommodates both 5 V and ±15 V laboratory applications.
Each channel includes an inverting input, a non-inverting input, and an output. The dual configuration reduces component count and board area when two related analog signals must be conditioned. The precision offset and drift specifications are especially important for DC measurements because they reduce the input-referred error produced by offset voltage and its temperature-dependent movement. Low bias current is valuable when driving high-impedance sensors or when source resistance creates input-referred bias errors.
Typical applications include precision bridge amplifiers, current-loop receivers, strain-gauge signal conditioning, laboratory instrumentation, biomedical instrumentation, and buffering for high-resolution data converters. The OPA2277PA is particularly appropriate when low offset and low drift matter more than wide bandwidth, rail-to-rail output capability, or operation above 18 V.
Designers should place input and feedback components close to the relevant pins, maintain the specified common-mode and output-voltage ranges, and use stable low-noise resistors where resistance values are high. Decoupling capacitors should be connected from each supply pin to ground with short return paths. Because the package is a through-hole PDIP, adequate lead spacing and mechanical clearance should be preserved during PCB layout.
This page combines the manufacturer's principal operating limits with drop-in replacement guidance, application-specific engineering guidance, and a parameter-by-parameter comparison. These design resources help engineers determine whether the OPA2277PA's precision, package, supply range, and channel configuration fit a particular analog signal chain before committing to a PCB design.
এর জন্য ড্রপ-ইন বিকল্প OPA2277PA — একই package, pin-to-pin compatible। ভিন্ন package-এর যেসব পার্টে PCB rework প্রয়োজন সেগুলো বাদ দেওয়া হয়েছে।
এই সিরিজের ভ্যারিয়েন্ট
একই সিরিজের মডেল যেগুলো drop-in compatible OPA2277PA (একই form factor এবং footprint) — পার্থক্য রয়েছে Amplifier Type, Package, Input Offset Voltage, Input Offset Voltage Drift, Number of Channels.
OPA2277P
✅ ড্রপ-ইন ⚠️ স্পেক যাচাইকৃত নয়মূল্যের জন্য যোগাযোগ করুন
ডেটাশিট দেখুন →OP277PA
✅ ড্রপ-ইন ⚠️ স্পেক যাচাইকৃত নয়📋 রেফারেন্স বিকল্প (ক্যাটালগে নেই)
OPA277PA
✅ ড্রপ-ইন ⚠️ স্পেক যাচাইকৃত নয়মূল্যের জন্য যোগাযোগ করুন
ডেটাশিট দেখুন →OPA2277PA সর্বোচ্চ রেটিং ও বৈদ্যুতিক বৈশিষ্ট্য
| Amplifier Type | Dual precision operational amplifier |
| Number of Channels | 2 channels |
| Input Offset Voltage | 10 uV maximum |
| Input Offset Voltage Drift | 0.1 uV/°C maximum |
| Gain-Bandwidth Product | 1 MHz |
| Supply Voltage Range | 2 V to 18 V |
| Single-Supply Operation | 5 V to 15 V |
| Dual-Supply Operation | 2 V to 18 V total |
| Slew Rate | 0.8 V/µs |
| প্যাকেজ | 8-pin PDIP (P) |
| মাউন্টিং টাইপ | Through-hole |
OPA2277PA পিন কনফিগারেশন
| পিন 1 | OUTA — Amplifier A output |
| পিন 2 | IN-A — Amplifier A inverting input |
| পিন 3 | IN+A — Amplifier A non-inverting input |
| পিন 4 | V- — Negative supply connection |
| পিন 5 | IN+B — Amplifier B non-inverting input |
| পিন 6 | IN-B — Amplifier B inverting input |
| পিন 7 | OUTB — Amplifier B output |
| পিন 8 | V+ — Positive supply connection |
সাধারণ ব্যবহার
OPA2277PA এর জন্য উপযুক্ত 6 অ্যাপ্লিকেশনs: Strain-Gauge Bridge Signal Conditioning, Precision Current-Loop Receiver, High-Resolution Data-Converter Buffering, Precision Reference Output, Medical and Diagnostic Instrumentation, Laboratory and Instrumentation Amplifier.
Strain-Gauge Bridge Signal Conditioning
The OPA2277PA is well suited to conditioning small differential signals from strain-gauge bridges because its 10 uV maximum input offset and 0.1 uV/°C maximum drift limit temperature-dependent measurement error. Each amplifier channel can support differential and common-mode signal paths around a bridge circuit while the 1 MHz gain-bandwidth product provides useful bandwidth for mechanical and thermal measurement bandwidths. The design should use low-temperature-coefficient gain resistors, verify the bridge excitation voltage against the input common-mode range, and keep high-impedance input traces short to reduce leakage and interference.
সুপারিশকৃত
Precision Current-Loop Receiver
OPA2277PA-based current receivers can provide accurate amplification of 4 mA to 20 mA industrial sensor signals when low offset and low bias current are important. Its 10 uV input offset creates a small input-referred error, while the 0.1 uV/°C drift limit helps preserve measurement stability as ambient temperature changes. The 2 V to 18 V supply range supports compact low-voltage instrumentation as well as ±15 V systems. Engineers should confirm the input common-mode range at every loop current, add input protection for industrial transients, and filter only as much as necessary to preserve the required response bandwidth.
সুপারিশকৃত
High-Resolution Data-Converter Buffering
The OPA2277PA can buffer the voltage output or reference node of a precision data converter when the system requires very low input bias current and tightly controlled offset. Its 10 uV offset and 0.1 uV/°C drift are valuable in DC-sensitive measurements, while the dual channel allows separate buffering or gain functions. The 1 MHz bandwidth is appropriate for many low- to moderate-speed converter interfaces but should be compared with acquisition settling requirements. Output loading, capacitor selection, converter settling behavior, and the amplifier's output-swing range must be evaluated together in the signal chain.
সুপারিশকৃত
Precision Reference Output
OPA2277PA is appropriate for active filtering and buffering of low-level reference voltages when reference accuracy is affected by source impedance or load variation. The low-offset architecture reduces the error introduced by the amplifier itself, while two channels can support complementary outputs or cascaded filtering stages. In a reference-conditioning circuit, capacitor tolerances and resistor drift may ultimately dominate accuracy, so precision components and thermal stability remain important. Confirm that the reference voltage stays inside the common-mode input range, verify output current against the load, and check settling against the required reference update time.
সুপারিশকৃত
Medical and Diagnostic Instrumentation
OPA2277PA can support low-level biomedical signal-conditioning stages where offset drift and input bias current influence measurement integrity. Its 10 uV maximum offset and 0.1 uV/°C maximum drift are useful for slow, precision-oriented acquisition paths, while the dual configuration reduces package count in multichannel front ends. These characteristics do not alone establish medical-device suitability, and safety, leakage, isolation, noise, and application-specific validation must be addressed separately. Designers should place high-impedance nodes over guarded surfaces, minimize leakage from contamination and protective components, and validate the complete analog path under the intended environmental conditions.
সুপারিশকৃত
Laboratory and Instrumentation Amplifier
The OPA2277PA is well matched to laboratory measurement front ends that need low DC error without the bandwidth of a high-speed amplifier. Two channels can implement differential excitation or measurement functions for bridge, potentiometer, and low-level voltage sources. Its 1 MHz gain-bandwidth product supports closed-loop gains where bandwidth remains adequate for the measurement bandwidth, and its 2 V minimum supply enables low-power bench designs. Leakage, stray capacitance, ground potential differences, and input protection should be managed carefully so that PCB contamination does not outweigh the amplifier's inherently low input bias current.
সুপারিশকৃত
সুপারিশকৃত পণ্যের সারসংক্ষেপ
এর জন্য ইঞ্জিনিয়ারিং রেফারেন্স ডেটা OPA2277PA — তুলনা, ডিজাইন গাইডেন্স এবং কমপ্লায়েন্স তথ্য।
নির্বাচন গাইড
বিকল্পের সাথে তুলনা
| পারামিটার | এই পণ্য | OPA2277P | OP277PA | OPA277PA |
|---|---|---|---|---|
| Package | 8-pin PDIP (P) | 8-pin PDIP (P) | 8-pin PDIP (P) | 8-pin PDIP (P) |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Number of Channels | 2 channels | 2 channels | 2 channels | 2 channels |
| Input Offset Voltage Drift | 0.1 uV/°C maximum | 0.1 uV/°C maximum | 0.8 uV/°C maximum | 0.5 uV/°C maximum |
| Primary Function | High-precision, low-power dual operational amplifier | High-precision, low-power dual operational amplifier | Precision dual operational amplifier | Precision dual operational amplifier |
মূল পার্থক্যসমূহ
- Lower offset drift than the OP277-family candidate (বনামOP277PA)
- Lower input offset than the OPA277-family candidate (বনামOPA277PA)
- Exact-family ordering option with the same PDIP footprint (বনামOPA2277P)
ডিজাইন নোট
Keep the two amplifier channels physically separated from switching supplies, high-current traces, and digital timing nets. Route each inverting input directly to its feedback resistor to minimize parasitic capacitance that can affect stability. Place input-biasing or bias-return resistors close to the non-inverting inputs, and connect supply-decoupling capacitors directly between each supply pin and ground with short, low-inductance paths.
Do not treat the OPA2277PA as a rail-to-rail input or output amplifier merely because it operates from 2 V to 18 V. Check the common-mode input range and output swing against the circuit's worst-case signal and load conditions. For high-impedance sources, verify leakage from PCB contamination and protective components because board leakage can exceed the amplifier's low input bias current even when the nominal offset performance remains excellent.
Use 0.1% or better resistors in gain networks when their contribution must remain small relative to the 10 uV input offset, and select resistor networks with suitable temperature coefficient for high-accuracy DC measurements. Keep feedback-loop bandwidth consistent with the intended closed-loop gain, and account for amplifier noise when estimating the resolution of the complete measurement chain. Capacitive loading at the output should remain within the manufacturer's recommended range.
Decouple the positive and negative supply pins independently, using short traces and a common ground reference close to the device. Confirm that the selected supply voltage and output load keep dissipation within the package's intended operating limits. In low-voltage single-supply systems, check the input and output signal levels against the common-mode and swing restrictions before selecting passive values.
কমপ্লায়েন্স তথ্য
No explicit RoHS, REACH, lead-free, halogen-free, conflict-minerals, or automotive qualification statement appears in the manufacturer product-page extract. AEC-Q100 is treated as not applicable to this standard industrial/commercial amplifier ordering configuration.