Skyworks Solutions

SI2439-A-GM V.34/V.92 ISOMODEM | Skyworks Solutions

MPN: SI2439-A-GM ✓ সক্রিয়
3 V to 3.6 V Vdss ITU-T V.34 and V.92 Rds(on) 38-pin QFN, 5 mm x 7 mm Package
সর্বনিম্ন অর্ডার পরিমাণ: 1 |

SI2439-A-GM সারাংশ

Skyworks Solutions SI2439-A-GM is a V.34 and V.92 ISOmodem system-side interface integrated circuit housed in a 38-pin QFN package measuring 5 mm by 7 mm. The device operates at 33.6 kbps and is intended for data communication equipment requiring a complete analog telephone-interface modem solution. Its defining characteristics include support for ITU-T V.34 and V.92 protocols, a global DAA, a 3 V to 3.6 V supply range, and surface-mount construction.

An ISOmodem is an integrated modem interface and data-access arrangement used within communications equipment. In this product category, the modem controller and telephone-line interface functions are combined to reduce the number of external components needed by the host system. Within the broader hierarchy, an ISOmodem is an interface IC, a communication IC, and ultimately a semiconductor designed to connect digital equipment to analog or digital communication channels.

The SI2439-A-GM is identified by Skyworks Solutions as a V.34/V.92 modem with global DAA support. It supports operation up to 33.6 kbps, as confirmed by the product listing for the exact MPN. The 38-QFN package places the device in a compact surface-mount format suitable for high-density communication equipment, while the exposed-pad construction provides a defined path for heat transfer through the PCB. The 3 V to 3.6 V operating supply allows integration with common low-voltage digital systems.

A primary use for this device is a data communications terminal or remote-access unit requiring a complete system-side modem. The global DAA can support country-specific telephone-line interfaces while the V.34 and V.92 capabilities provide compatibility with legacy and higher-speed modem standards. Integration can reduce board area compared with a discrete codec, line-driver, and controller implementation, although the host equipment must still satisfy the applicable telephone-network requirements.

Designers should pay close attention to the analog line interface, supply decoupling, exposed-pad soldering, and signal-integrity layout. The manufacturer datasheet is the controlling document for pin assignments, recommended external circuitry, timing, electrical limits, and programming procedures. Because the modem connects directly to communication circuitry, keep sensitive analog routing separated from noisy digital and power-conversion paths, and provide the required bypass capacitors close to the supply pins.

This product page organizes the exact SI2439-A-GM identity, package information, technical specifications, sourcing guidance, and verified same-family alternatives into one engineering reference. It also distinguishes confirmed catalog parameters from detailed electrical characteristics that must be established from the manufacturer datasheet before schematic capture or production release.

এর জন্য ড্রপ-ইন বিকল্প SI2439-A-GM — একই package, pin-to-pin compatible। ভিন্ন package-এর যেসব পার্টে PCB rework প্রয়োজন সেগুলো বাদ দেওয়া হয়েছে।

এই সিরিজের ভ্যারিয়েন্ট

একই সিরিজের মডেল যেগুলো drop-in compatible SI2439-A-GM (একই form factor এবং footprint) — পার্থক্য রয়েছে Maximum Data Rate, Package, Product Type.

Skyworks Solutions
Maximum Data Rate: 56 kbps
Package: 38-pin QFN with exposed pad, 5 mm x 7 mm
Product Type: System-side ISOmodem data communications controller
এর সাথে তুলনা করুন SI2439-A-GM →

SI2439-B-GM

✅ ড্রপ-ইন
📦 38-QFN (5x7)
Same SI2439 family and 38-QFN format, with unspecified minor feature or performance variations; protocol and pin-level differences must be verified before substitution

📋 রেফারেন্স বিকল্প (ক্যাটালগে নেই)

SI2439-C-GM

✅ ড্রপ-ইন
📦 38-QFN (5x7)
Same SI2439 family and 38-QFN format, with unspecified minor feature or performance variations; protocol and pin-level differences must be verified before substitution

📋 রেফারেন্স বিকল্প (ক্যাটালগে নেই)

SI2494-A-GM

✅ ড্রপ-ইন
Skyworks Solutions
📦 38-QFN (5x7)
System-side ISOmodem data communications controller · 56 kbps · V.21, V.22, V.29, V.32, V.34, V.42, V.42bis, V.44, and V.92 · Bell 300 bps · Supported · Supported · Supported · MNP2-5

মূল্যের জন্য যোগাযোগ করুন

ডেটাশিট দেখুন →

SI2439-A-GM বিশেষণ

Product Type V.34/V.92 ISOmodem system-side interface IC
Maximum Data Rate 33.6 kbps
Supported Modem Standards ITU-T V.34 and V.92
DAA Support Global DAA
Supply Voltage Range 3 V to 3.6 V
প্যাকেজ 38-pin QFN, 5 mm x 7 mm
Package Form 38-VFQFN with exposed pad
মাউন্টিং টাইপ Surface mount
Component Category Modems ICs and Modules
Product Family ISOmodem chipset
Data Standards V.92 and V.34
RoHS স্ট্যাটাস RoHS compliant
Lead-Free Status Lead free

SI2439-A-GM 38-vfqfn with exposed pad পিন কনফিগারেশন গাইড

SI2439-A-GM (38-vfqfn with exposed pad প্যাকেজ)-এর পিন কনফিগারেশন। পিন নম্বরিং, ফাংশন এবং সংযোগ ডায়াগ্রাম প্রস্তুতকারকের ডেটাশিটে সংজ্ঞায়িত করা আছে। সঠিক ফুটপ্রিন্ট এবং সোল্ডারিং নির্দেশিকার জন্য এটি দেখুন।

SI2439-A-GM-এর জন্য 38-vfqfn with exposed pad প্যাকেজ পিনআউট ডায়াগ্রাম

এর জন্য বিস্তারিত পিনআউট ডেটা পাওয়া যায়নি SI2439-A-GM.

দেখুন ডেটাশিট সম্পূর্ণ পিন কনফিগারেশনের জন্য।

সাধারণ ব্যবহার

SI2439-A-GM এর জন্য উপযুক্ত 6 অ্যাপ্লিকেশনs: V.34 Remote-Access Terminal, V.92 Data-Modem Equipment, Global-DAA Telephone Interface, Industrial Data Communication Gateway, Embedded Data Terminal, Telecommunications Service Equipment.

🌐

V.34 Remote-Access Terminal

SI2439-A-GM fits a remote-access terminal requiring a system-side modem at up to 33.6 kbps. The confirmed V.34 capability provides the protocol foundation, while V.92 support broadens compatibility with the surrounding access equipment. Place the IC beside the telephone-network interface and route the analog line signals according to the manufacturer reference design. Its 38-QFN 5 mm by 7 mm package preserves board area in compact terminal hardware, but the exposed-pad land pattern and grounding layout must follow the datasheet exactly.

📡

V.92 Data-Modem Equipment

SI2439-A-GM is suitable for equipment designed around V.92 modem operation while retaining V.34 compatibility. The device's documented maximum data rate of 33.6 kbps makes it relevant to legacy and transition-era modem systems, and its global DAA support simplifies integration where country-specific line-interface behavior must be managed. The 3 V to 3.6 V operating range aligns with low-voltage host logic, although the power architecture, bypass network, and host-control interface must be implemented exactly as described by Skyworks Solutions.

☎️

Global-DAA Telephone Interface

The global DAA identified for SI2439-A-GM supports telephone-interface designs intended for internationally varied line conditions. Integrating the DAA-related function into the system-side modem can simplify board partitioning while retaining V.34 and V.92 operation. However, DAA integration does not remove country-specific certification or network-interface obligations. The implementation should follow the recommended line-network components, isolation strategy, and analog layout in the manufacturer datasheet, with particular attention to keeping sensitive line signals away from digital switching paths.

🏭

Industrial Data Communication Gateway

SI2439-A-GM can support legacy connectivity in an industrial gateway that must interoperate with V.34 or V.92 modem equipment. The 33.6 kbps rate is appropriate for low-bandwidth control, configuration, and monitoring links rather than modern high-throughput traffic. Its 38-QFN package supports compact industrial terminal designs, but deployment requires confirmation of operating-temperature limits, EMC performance, and environmental compliance from the manufacturer documentation before the product is used in harsh environments.

🖥️

Embedded Data Terminal

SI2439-A-GM is appropriate for embedded terminals that require a direct modem connection rather than an external USB or network modem. Supporting both V.34 and V.92 lets one platform address a broad range of legacy access equipment. The compact 38-QFN package and 3 V to 3.6 V supply support integration into dense embedded systems, while system designers must budget board area for the recommended external telephone-interface network, bypass capacitors, and exposed-pad thermal construction.

📞

Telecommunications Service Equipment

SI2439-A-GM can be evaluated for telecommunications service equipment that still depends on V.34 and V.92 modem links. The global DAA and system-side modem positioning make it relevant to line-interface subsystems, test equipment, and legacy-access adapters. Since the catalog summaries establish protocol and packaging but not full electrical ratings, engineers should verify clock tolerance, line impedance requirements, operating temperature, EMC behavior, and production test procedures in the manufacturer datasheet before architecture approval.

সুপারিশকৃত পণ্যের সারসংক্ষেপ

SI2439-B-GM Same-family V.34/V.92 ISOmodem alternative ব্যবহৃত হয়: V.34 Remote-Access Terminal, Global-DAA Telephone Interface, Embedded Data Terminal SI2439-C-GM Same-family V.34/V.92 ISOmodem alternative ব্যবহৃত হয়: V.34 Remote-Access Terminal, Global-DAA Telephone Interface, Embedded Data Terminal SI2494-A-GM Skyworks Solutions ব্যবহৃত হয়: V.92 Data-Modem Equipment, Industrial Data Communication Gateway, Telecommunications Service Equipment SI2439-A-GM Skyworks Solutions ব্যবহৃত হয়: V.92 Data-Modem Equipment, Industrial Data Communication Gateway, Telecommunications Service Equipment
What is SI2439-A-GM?
SI2439-A-GM is a Skyworks Solutions system-side ISOmodem IC that supports V.34 and V.92 modem operation at up to 33.6 kbps. According to the Skyworks product description, it includes global DAA support and is packaged in a 38-QFN measuring 5 mm by 7 mm. Its main role is to provide modem and telephone-interface functionality within communications equipment.
What are the key specifications of SI2439-A-GM that engineers should know?
The principal SI2439-A-GM specifications are 33.6 kbps operation, V.34 and V.92 support, global DAA capability, a 3 V to 3.6 V supply range, and a 38-QFN package measuring 5 mm by 7 mm. The Skyworks catalog identifies the part as a modem IC. Additional electrical limits and timing values should be confirmed in the manufacturer datasheet before schematic approval.
Where can I download the SI2439-A-GM datasheet PDF?
The SI2439-A-GM datasheet PDF is available from the listed Skyworks document repository, whose search result identifies the document as covering the V.92 and V.34 ISOmodem with global DAA. Use the manufacturer datasheet for the final pin descriptions, timing values, electrical characteristics, recommended components, and application schematic rather than relying on distributor summaries.
Where can I find the SI2439-A-GM pinout?
The SI2439-A-GM pinout is contained in the manufacturer datasheet rather than in the distributor search summaries. The exact package is a 38-pin QFN with an exposed pad. Consult the datasheet pin-description table when assigning PCB nets, especially for supply, ground, analog telephone-line, and host-interface signals.
Is SI2439-A-GM suitable for a V.34 modem application?
Yes, SI2439-A-GM is explicitly identified as a V.34 modem IC with operation up to 33.6 kbps. The device also includes V.92 support and global DAA capability, making it appropriate for communications equipment that needs a complete system-side ISOmodem function and compatibility with V.34-based connections.
What is the power supply requirement for SI2439-A-GM?
SI2439-A-GM operates from a 3 V to 3.6 V supply. The exact test conditions, absolute maximum ratings, and recommended decoupling should be taken from the manufacturer datasheet. In implementation, place the required bypass capacitors near their associated pins and keep analog and digital return-current paths controlled.
How does SI2439-A-GM differ from SI2494-A-GM?
SI2494-A-GM is identified in a direct comparison page as another member of the same ISOmodem product family, but the available comparison summary does not establish pin-for-pin interchangeability. Both are associated with the SI24xx modem family, yet the protocol set, clocking, line interface, and pin assignments must be checked before either device replaces the other.
SI2439-A-GM vs SI2439-B-GM: which is better for a new design?
SI2439-A-GM is the baseline choice when the design specifically calls for the exact A-grade ordering variant supporting V.34 and V.92 operation up to 33.6 kbps. SI2439-B-GM is identified as an alternative with minor feature or performance variations, but the published summary does not quantify those changes. Select it only after comparing the datasheets, pin table, and required modem features.
When should I choose SI2439-A-GM instead of another SI24xx modem?
Choose SI2439-A-GM when the equipment requires the confirmed combination of V.34, V.92, global DAA, 33.6 kbps operation, and a 38-QFN implementation. A different SI24xx device may be preferable if it adds required clocks, codecs, protocol modes, package options, or qualification. The deciding factors should be protocol coverage, pin compatibility, and the host-system architecture.
Is SI2439-A-GM suitable for industrial or embedded communications equipment?
SI2439-A-GM can support embedded communications equipment that implements V.34/V.92 modem connectivity and global DAA requirements. Its suitability for a specific industrial environment depends on operating-temperature limits, EMC performance, and regulatory requirements that are not stated in the catalog summaries. Confirm those characteristics against the manufacturer datasheet and applicable product certification records.
What can replace SI2439-A-GM?
SI2439-B-GM and SI2439-C-GM are identified same-family alternatives to SI2439-A-GM, while SI2494-A-GM is another related modem variant. A defensible drop-in replacement requires exact package, pin mapping, supply voltage, clocking, protocol, and exposed-pad compatibility. The available summaries do not prove those conditions, so validate each candidate against the manufacturer datasheet before substitution.
What is the best alternative manufacturer equivalent for SI2439-A-GM?
No cross-manufacturer drop-in equivalent is established by the available cross-reference results. The search results identify generic comparison tools and same-family Skyworks variants, but they do not document a competing 38-QFN device with matching pinout and modem functionality. Treat any cross-brand candidate as a redesign requiring full electrical, protocol, clocking, and mechanical validation.
Where can I buy SI2439-A-GM online?
SI2439-A-GM can be requested through the Request a Quote form on this product page. The form allows buyers to state required quantity, target packaging, and delivery expectations without relying on changing public prices. The manufacturer and distributor listings also confirm that the exact SI2439-A-GM ordering code is actively cataloged.
What is the price of SI2439-A-GM?
Use the Request a Quote form on this page for the current SI2439-A-GM price and quantity breaks. Pricing can vary with quantity, date, and channel, so a durable figure should be obtained for the exact MPN and required ship date. The qualified price evidence field is empty because the catalog results do not provide a complete quantity-break table for this exact MPN.
What is the lead time and stock status for SI2439-A-GM?
Request current stock, minimum order quantity, and lead time through the Request a Quote form on this page. One catalog result describes the part as available to buy and ship, while other listings reference inventory or stock, but the retrieved data does not establish a dated, quantity-specific commitment. Confirm availability against the requested quantity and manufacturing schedule.
Does SI2439-A-GM support RoHS and lead-free manufacturing?
SI2439-A-GM is listed as RoHS compliant and lead free. These declarations support lead-free production planning, but the product description does not establish every other environmental or automotive qualification. Use the manufacturer datasheet and applicable declarations for halogen-free, conflict-minerals, and lifecycle details.
What PCB layout practices are important for SI2439-A-GM?
Keep the modem's telephone-line and analog signal paths compact and isolated from switching nodes and digital return currents. Follow the manufacturer datasheet's recommended decoupling, exposed-pad, grounding, and trace-routing diagrams exactly. Because the 38-QFN has an exposed pad, verify the PCB land pattern and solder-process requirements during footprint and assembly review.

এর জন্য ইঞ্জিনিয়ারিং রেফারেন্স ডেটা SI2439-A-GM — তুলনা, ডিজাইন গাইডেন্স এবং কমপ্লায়েন্স তথ্য।

নির্বাচন গাইড

Choose SI2439-A-GM when the BOM specifies the exact A-grade ordering variant and the equipment needs a confirmed system-side ISOmodem supporting V.34 and V.92 at up to 33.6 kbps with global DAA capability. Its 38-QFN 5 mm by 7 mm package is appropriate for compact communications equipment. Consider SI2439-B-GM or SI2439-C-GM when a same-family ordering variant can meet the design and its changes have been checked against the datasheet. Use SI2494-A-GM only after comparing its protocol set, clocks, pinout, DAA implementation, and host interface. No cross-manufacturer drop-in equivalent is established, so changing vendors should be treated as a redesign rather than a procurement substitution. For every candidate, confirm supply voltage, package drawing, exposed-pad treatment, operating temperature, and lifecycle status before release.

বিকল্পের সাথে তুলনা

পারামিটার এই পণ্য SI2439-B-GM SI2439-C-GM SI2494-A-GM
Package 38-QFN (5x7) 38-QFN (5x7) 38-QFN (5x7) 38-QFN (5x7)
Brand Skyworks Solutions Skyworks Solutions Skyworks Solutions Skyworks Solutions
Product Type System-side ISOmodem System-side ISOmodem System-side ISOmodem V.92/V.34 ISOmodem
V.34 Support Supported Supported by SI2439 family Supported by SI2439 family Supported
V.92 Support Supported Supported by SI2439 family Supported by SI2439 family Supported

মূল পার্থক্যসমূহ

  • Exact cataloged V.34 and V.92 system-side modem configuration (বনামSI2494-A-GM)
  • Direct A-grade ordering variant (বনামSI2439-B-GM)
  • Compact 38-QFN integration in a 5 mm by 7 mm footprint (বনামSI2439-C-GM)

ডিজাইন নোট

Use the manufacturer PCB land pattern for the 38-QFN 5 mm by 7 mm package, including its exposed pad, rather than creating a generic 38-pin footprint. Confirm pad dimensions, solder-mask opening, and paste stencil against the latest package drawing. A mechanically correct footprint is essential because the exposed pad also provides the primary vertical thermal path and may be tied to ground according to the reference design.

Separate the telephone-line and other sensitive analog paths from digital clocks, switching-regulator nodes, and high-current return paths. Keep the modem and its recommended passive network compact, use short ground returns, and avoid routing communications traces beneath isolated or noisy regions. Follow the manufacturer reference layout for component orientation and line-network placement because small analog-routing differences can affect signal integrity and test margins.

Design a stable 3 V to 3.6 V supply for the modem and place the recommended bypass capacitors close to their associated device pins. Check the datasheet for sequencing, ripple tolerance, and capacitor technology before fixing the power network. The exposed-pad connection should follow the manufacturer grounding instructions, and analog supply branches should avoid sharing high-impedance return paths with unrelated digital loads.

Do not treat SI2439-B-GM, SI2439-C-GM, or SI2494-A-GM as interchangeable solely because they are related modem variants. Compare the complete pin-description table, clock requirements, protocol features, host interface, DAA implementation, recommended external network, and exposed-pad connection. Any substitution also requires confirmation that the package suffix, temperature grade, and production configuration remain equivalent.

কমপ্লায়েন্স তথ্য

RoHS
Compliant
REACH
Unknown
AEC-Q100
Unknown
লিড ফ্রি
Yes
হ্যালোজেন ফ্রি
Unknown
কনফ্লিক্ট মিনারেলস
Unknown

The SI2439-A-GM datasheet listing states RoHS compliant and lead free. No AEC-Q100 qualification, REACH status, halogen-free declaration, or conflict-minerals statement is established.

ডেটা যাচাই করা হয়েছে: 2026-11-08 — ডেটা XAIPART-এর কম্পোনেন্ট ইঞ্জিনিয়ারিং টিম দ্বারা যাচাই ও কিউরেট করা হয়েছে

সম্পর্কিত অনুসন্ধান

SI2439-A-GM datasheet SI2439-A-GM pinout SI2439-A-GM datasheet pdf SI2439-A-GM equivalent SI2439-A-GM replacement SI2439-A-GM price SI2439-A-GM stock SI2439-A-GM footprint SI2439-A-GM application circuit SI2439-A-GM vs SI2439-B-GM SI2439-A-GM vs SI2494-A-GM Skyworks Solutions SI2439-A-GM SI2439-A-GM 33.6 kbps modem SI2439-A-GM 38-QFN

সম্পর্কিত কম্পোনেন্ট ও শর্তাবলী

Skyworks Solutions SI2439-A-GM SI2439-B-GM SI2439-C-GM SI2494-A-GM ISOmodem system-side modem modem controller V.34 V.92 global DAA data-access arrangement DAA ITU-T modem standard 33.6 kbps 38-QFN VQFN surface-mount package exposed pad telephone-line interface interface IC communication IC semiconductor RoHS lead-free
তাৎক্ষণিক বিলওয়াছে রেকোজিউইট
সম্পূর্ণ বিবরণ পূরণ করুন — আমাদের সেলস টিম 24 ঘণ্টার মধ্যে উত্তর দেবে
পার্ট নম্বর উৎপাদক প্যাকেজ QTY লক্ষ্যমূল্য প্রসারিত
✓
বিল প্রস্তুত করা হয়েছে!

আমরা ২৪ ঘণ্টার মধ্যে আপনার ইমেইলে প্রত্যুত্তর দেব

1
RFQ জমা হয়েছে
2
কোটেশন পাওয়া গেছে
3
অর্ডার দেওয়া হয়েছে
4
পেমেন্ট
5
শিপ করা হয়েছে
6
ডেলিভারি হয়েছে
RFQ বিবরণ দেখুন