Microchip Technology

SY89467UHY - 1:20 LVPECL Clock Fanout | Microchip

MPN: SY89467UHY ✓ সক্রিয়
2.5 V or 3.3 V Vdss 64-TQFP exposed pad Package 2 GHz Speed
সর্বনিম্ন অর্ডার পরিমাণ: 1 |

SY89467UHY সারাংশ

The Microchip Technology SY89467UHY is a 2.5 V/3.3 V LVPECL clock fanout buffer with a 2:1 differential input multiplexer, 20 LVPECL outputs, and a maximum clock frequency of 2 GHz in a 64-TQFP exposed-pad package. It is designed for systems that must select between two differential clock sources and distribute the selected clock across multiple high-speed loads.

A clock fanout buffer is a clock-and-timing integrated circuit that reproduces a high-speed differential clock with low skew and controlled impedance. This device combines that distribution function with a 2:1 input multiplexer. The resulting topology is useful when a serializer, transceiver, retimer, FPGA, or communication engine must switch between two clock domains while maintaining a consistent LVPECL interface. Within the product hierarchy, it is a clock buffer and clock multiplexer, both belonging to clock-and-timing ICs and ultimately to the broader semiconductor category.

The SY89467UHY provides 2:1 differential input selection, a 1:20 output fanout ratio, and operation from a 2.5 V or 3.3 V supply. Its listed operating-temperature range is -40°C to +85°C, while distributor records identify the device as a 2 GHz, 64-TQFP exposed-pad clock fanout buffer with multiplexer functionality. These characteristics make the part relevant to high-speed digital systems requiring more output copies than a simple one-to-one clock buffer can supply.

A particularly important feature is Fail-Safe Input protection. According to the Microchip Technology product page, the FSI function helps prevent metastable output conditions when the selected input clock fails to a DC voltage. This behavior supports dependable system operation during clock-source faults, although designers still need to evaluate startup, input biasing, and source-switching requirements against the complete manufacturer application guidance.

Typical uses include high-speed serial links, parallel data converters, telecommunications equipment, test-and-measurement instrumentation, FPGA clock distribution, and data-converter clocking. The 20-output architecture can feed several parallel LVPECL destinations from one selected differential source, while the multiplexer permits redundancy or source selection without requiring two complete downstream clock trees.

The main design consideration is that the exposed-pad package requires careful PCB layout for thermal and electrical performance. Place the device close to the clock source and destinations, keep high-speed traces short and impedance controlled, provide the required decoupling and termination, and connect the exposed pad to the recommended ground-plane construction. Confirm all pin assignments, LVPECL interface details, and unused-output termination against the manufacturer datasheet before fabrication.

This product record combines the manufacturer's functional description with distributor electrical and package details, drop-in replacement information, a parameter comparison, and practical clock-distribution design guidance. It is intended to help engineers identify the correct voltage, package, fanout, multiplexer, and fault-tolerance requirements before integrating the SY89467UHY into a high-speed clock architecture.

এর জন্য ড্রপ-ইন বিকল্প SY89467UHY — একই package, pin-to-pin compatible। ভিন্ন package-এর যেসব পার্টে PCB rework প্রয়োজন সেগুলো বাদ দেওয়া হয়েছে।

SY89467UHY-TR

✅ ড্রপ-ইন
📦 64-TQFP exposed pad
Identical 2:1 input multiplexer, 1:20 LVPECL fanout, 2 GHz clock rate, and 64-TQFP exposed-pad terminal arrangement; ordering suffix identifies the tape-and-reel configuration.

📋 রেফারেন্স বিকল্প (ক্যাটালগে নেই)

SY89467UHY বিশেষণ

Product Type LVPECL clock fanout buffer with 2:1 differential input multiplexer
Input Configuration 2 differential inputs
আউটপুট কনফিগারেশন 20 LVPECL outputs
Fanout Ratio 1:20
Multiplexer Ratio 2:1
সর্বোচ্চ ক্লক ফ্রিকোয়েন্সি 2 GHz
Nominal Supply Voltage 2.5 V or 3.3 V
Operating Supply Voltage Range 2.375 V to 3.6 V
অপারেটিং তাপমাত্রার পরিসর -40°C to +85°C
প্যাকেজ 64-TQFP exposed pad
পিন সংখ্যা 64 pins
মাউন্টিং টাইপ Surface mount
Logic Family LVPECL
Fail-Safe Input Yes

SY89467UHY 64-tqfp exposed pad পিন কনফিগারেশন গাইড

SY89467UHY (64-tqfp exposed pad প্যাকেজ)-এর পিন কনফিগারেশন। পিন নম্বরিং, ফাংশন এবং সংযোগ ডায়াগ্রাম প্রস্তুতকারকের ডেটাশিটে সংজ্ঞায়িত করা আছে। সঠিক ফুটপ্রিন্ট এবং সোল্ডারিং নির্দেশিকার জন্য এটি দেখুন।

SY89467UHY-এর জন্য 64-tqfp exposed pad প্যাকেজ পিনআউট ডায়াগ্রাম

এর জন্য বিস্তারিত পিনআউট ডেটা পাওয়া যায়নি SY89467UHY.

দেখুন ডেটাশিট সম্পূর্ণ পিন কনফিগারেশনের জন্য।

সাধারণ ব্যবহার

SY89467UHY এর জন্য উপযুক্ত 6 অ্যাপ্লিকেশনs: High-Speed Serial-Link Clock Distribution, FPGA Clock Distribution, Data-Converter and Parallel Interface Clocking, Telecommunications Backplane Clocking, Test and Measurement Instrumentation, Clock Redundancy and Source Switching.

🌐

High-Speed Serial-Link Clock Distribution

The SY89467UHY fits serial-link clock distribution when the system must select between two differential clock sources and drive multiple LVPECL endpoints. Its 2:1 input multiplexer avoids duplicating the downstream fanout network, while the 1:20 ratio provides 20 outputs for transceivers, retimers, serializers, or interface controllers. Operation up to 2 GHz supports demanding clock trees, and the 2.375 V to 3.6 V supply range accommodates nominal 2.5 V or 3.3 V systems. The design must preserve controlled-impedance routing, apply the manufacturer's LVPECL interface network, and implement the exposed-pad ground and via arrangement. Fail-Safe Input adds value when a selected source can fail to a DC voltage, but downstream logic should still monitor clock health and initiate recovery.

🖥️

FPGA Clock Distribution

The SY89467UHY is useful when an FPGA or multiple FPGA tiles need low-skew LVPECL clock copies from one of two selectable differential sources. Twenty outputs allow one selected clock to serve several fabric or interface clock inputs without constructing a large tree from discrete buffers. The 2 GHz maximum clock frequency accommodates high-speed fabric and transceiver clocking, while Fail-Safe Input helps constrain output behavior if the selected reference settles at a DC level. In implementation, place the buffer near the clock-source and destination region, use the manufacturer's pinout and exposed-pad layout, maintain controlled impedance, and ensure each LVPECL receiver uses the specified termination. External clock monitoring and switching control remain necessary for deterministic fault recovery.

📺

Data-Converter and Parallel Interface Clocking

The SY89467UHY can supply multiple parallel data converters, interface controllers, or acquisition channels from a selected differential clock. Its 1:20 fanout provides enough copies for grouped clock domains, and the integrated 2:1 multiplexer permits source redundancy or alternating clock selection. The 2.5 V or 3.3 V operating point aligns with many high-speed mixed-signal systems, while the 2 GHz capability supports demanding sampling or transfer rates. Because converter timing depends on low skew and clean transitions, route clock outputs as short controlled-impedance traces, apply the specified LVPECL termination, decouple supply pins near the device, and keep the exposed pad connected to the recommended ground-plane structure. Validate edge quality and channel-to-channel timing in the final board environment.

🌐

Telecommunications Backplane Clocking

The SY89467UHY is appropriate for telecommunications equipment that requires a selected differential reference clock to reach several line-card or backplane interface circuits. Twenty LVPECL outputs reduce the number of separate fanout stages, while the 2:1 mux supports primary and alternate source selection. Its operation to 2 GHz is suitable for high-rate communication paths, and the stated -40°C to +85°C range covers industrial telecom environments. Board-level implementation is critical: preserve differential impedance, minimize clock-route length and branching, use recommended termination values, and provide a solid ground reference to the exposed pad. Fail-Safe Input improves behavior during a failed DC input condition, but a system-level health monitor and safe state machine should still determine which source is enabled.

🔧

Test and Measurement Instrumentation

The SY89467UHY can distribute a selected high-speed reference clock across multiple acquisition, synthesis, or calibration blocks in test-and-measurement equipment. Twenty outputs allow one LVPECL source to feed instrument sections that require coherent timing, and the integrated 2:1 input selection supports switching between an internal and external reference. The 2 GHz maximum frequency supports demanding test clocks, while nominal 2.5 V or 3.3 V operation fits many mixed-signal instrument architectures. Preserve edge quality by using short routes, continuous reference planes, correct LVPECL termination, and the manufacturer's exposed-pad via pattern. If the instrument expects deterministic phase relationships during source changes, evaluate source isolation and loop-locking behavior because the multiplexer changes which clock reaches all 20 outputs.

⚡

Clock Redundancy and Source Switching

The SY89467UHY addresses clock redundancy by selecting between two differential inputs and driving the selected clock to 20 LVPECL outputs. This is useful when a system needs to switch between a primary oscillator, an external reference, or another low-jitter source without duplicating the entire distribution network. The Fail-Safe Input feature helps prevent metastable outputs when the selected input fails to a DC voltage, improving the behavior of a fault transition. Engineering validation should still include switch timing, output continuity requirements, receiver tolerance, and system recovery logic. Keep the two input networks symmetric where possible, use controlled-impedance routing, and monitor both sources through separate diagnostic paths so that a failed reference can be identified before it disrupts the distributed clock.

সুপারিশকৃত পণ্যের সারসংক্ষেপ

SY89467UHY-TR Same-function, same-package ordering option for a tape-and-reel assembly flow ব্যবহৃত হয়: High-Speed Serial-Link Clock Distribution, FPGA Clock Distribution, Data-Converter and Parallel Interface Clocking, Telecommunications Backplane Clocking, Test and Measurement Instrumentation, Clock Redundancy and Source Switching SY89467U Microchip base-family device for the 1:20 LVPECL fanout and 2:1 input multiplexer ব্যবহৃত হয়: High-Speed Serial-Link Clock Distribution, FPGA Clock Distribution, Data-Converter and Parallel Interface Clocking, Telecommunications Backplane Clocking, Test and Measurement Instrumentation, Clock Redundancy and Source Switching
What is the Microchip SY89467UHY?
The Microchip SY89467UHY is a 2.5 V/3.3 V LVPECL clock fanout buffer with a 2:1 differential input multiplexer. It distributes one selected differential clock source to 20 LVPECL outputs, supports operation up to 2 GHz, and is packaged in a 64-TQFP with an exposed pad. According to the Microchip Technology product page, the device also includes Fail-Safe Input protection to help prevent metastable outputs when the selected clock fails to a DC voltage.
What are the key specifications of SY89467UHY that engineers should know?
The SY89467UHY combines 2 differential inputs, 20 LVPECL outputs, a 1:20 fanout ratio, and operation up to 2 GHz. Its supply range is 2.375 V to 3.6 V for nominal 2.5 V or 3.3 V operation, and its stated temperature range is -40°C to +85°C. The 64-TQFP exposed-pad package is also a key integration consideration because its pad and thermal construction must follow the manufacturer's PCB-layout requirements.
Where can I download the SY89467UHY datasheet PDF?
The official SY89467UHY documentation starts at the Microchip Technology product page for SY89467U. That page links the device to its manufacturer datasheet and associated technical resources. Use the manufacturer's document for the authoritative pin descriptions, recommended application circuit, exposed-pad layout, electrical characteristics, and input/output termination details. Distributor search results also identify the part as a 2 GHz, 2:1 multiplexer and 1:20 clock fanout buffer in a 64-TQFP exposed-pad package.
Where can I find the SY89467UHY pinout?
The SY89467UHY pinout is defined by the manufacturer datasheet for the 64-TQFP exposed-pad package. Use the package drawing and pin-description table to assign every power, ground, differential clock input, LVPECL output, control, and exposed-pad connection. The exposed pad is part of the thermal and electrical construction, so it should not be treated as an unused pin. Do not infer pin functions from a generic TQFP-64 library diagram because the control and exposed-pad assignments are device-specific.
What does Fail-Safe Input mean on the SY89467UHY?
Fail-Safe Input on the SY89467UHY is intended to prevent metastable output conditions when the selected clock input fails to a DC voltage. This protection supports predictable behavior during a clock-source fault, which is important when a single source feeds multiple high-speed destinations. According to the Microchip Technology product page, the FSI feature addresses the failed-input condition; it does not replace correct input biasing, source control, downstream clock monitoring, or system-level recovery logic.
When should I choose SY89467UHY for a clock-distribution design?
Choose the SY89467UHY when the design must select between two differential clock sources and distribute the selected source to as many as 20 LVPECL destinations. It is particularly suitable when the clock frequency reaches 2 GHz, the supply operates in the 2.375 V to 3.6 V range, and source-failure behavior is important. It is less suitable when fewer outputs are needed, single-ended clocking is required, or a lower-cost general-purpose buffer is sufficient.
Is SY89467UHY suitable for FPGA and high-speed serial interfaces?
The SY89467UHY is suitable for high-speed clock distribution associated with FPGA designs, serial links, and parallel converters when those loads accept LVPECL and the complete interface requirements are satisfied. Its 20 outputs support several destinations from one selected differential source, and its 2 GHz maximum frequency addresses demanding clock trees. The board design must still use controlled-impedance routing, suitable termination, decoupling, and the manufacturer-recommended exposed-pad layout.
What is the difference between SY89467UHY and SY89467UHY-TR?
SY89467UHY-TR is identified by distributor records as a 64-TQFP exposed-pad version of the same 2:1 multiplexer and 1:20 clock fanout architecture. A cross-reference result states that the two devices have consistent terminal and package arrangements and can replace one another without modification of the existing circuit. The principal ordering distinction is the -TR packaging suffix, so engineers should confirm reel or tape-and-reel configuration, procurement format, and procurement availability before treating it as a substitution.
What is the best drop-in replacement for SY89467UHY?
SY89467UHY-TR is the documented drop-in replacement candidate for the SY89467UHY. The cross-reference listing describes matching performance characteristics, terminals, and package, with no circuit modification required. It uses the same 64-TQFP exposed-pad format and the same 2:1 input multiplexer with 1:20 fanout function. Always verify ordering code, manufacturing status, and exact electrical characteristics against the manufacturer datasheet before converting an existing design.
Can SY89467UHY-TR replace SY89467UHY on an existing PCB?
Yes, SY89467UHY-TR can replace SY89467UHY without changing the circuit according to the available cross-reference information. Both use a 64-TQFP exposed-pad package with consistent terminals, and the listed multiplexer, fanout, and clock-frequency characteristics are consistent. Because the distinction can include ordering or shipping format, verify that the replacement's mechanical orientation, exposed-pad connection, electrical limits, and intended delivery method align with the existing assembly process.
What can replace SY89467UHY?
The directly documented replacement is SY89467UHY-TR, which a cross-reference listing identifies as having consistent performance characteristics, terminals, and package. No additional qualified cross-brand drop-in replacement was established by the available compatibility information, so other devices should not be assumed to be pin-compatible. A valid substitution must retain the 64-TQFP exposed-pad footprint, 2:1 differential input multiplexing, 1:20 LVPECL fanout, 2.375 V to 3.6 V supply range, and required timing performance.
Is there a Microchip equivalent for SY89467UHY with the same package?
The closest documented Microchip ordering equivalent is SY89467UHY-TR, which retains the same 64-TQFP exposed-pad package and is described as a complete replacement with consistent terminals and performance characteristics. No separate competitor MPN with independently verified pin compatibility was identified. For an equivalent selection, prioritize identical package construction, supply range, differential input architecture, output count, frequency capability, Fail-Safe Input behavior, and output-edge performance rather than relying only on a generic fanout-buffer description.
How should the SY89467UHY exposed-pad PCB layout be handled?
The 64-TQFP exposed pad should follow the manufacturer's recommended land pattern, thermal-pad geometry, and via arrangement. Connect the pad to the specified ground construction and provide low-impedance return paths for every LVPECL output. Place decoupling and interface components close to their associated pins, preserve controlled differential and single-ended LVPECL impedance, and minimize stubs on 2 GHz-class clock routes. Confirm the final stack-up and termination arrangement in the manufacturer datasheet and signal-integrity simulation.
Where can I buy SY89467UHY online and what is its price?
Use the Request a Quote form on this page to ask about SY89467UHY price, stock, minimum order quantity, lead time, and delivery format. The component is a 64-TQFP exposed-pad clock fanout buffer and multiplexer with a stated operating-temperature range of -40°C to +85°C. Commercial terms can change with volume and packaging, so request a current quotation for the exact ordering code rather than relying on a static price reference.
Is SY89467UHY in stock and what is its lead time?
Current stock and lead time should be requested through the Request a Quote form on this page. Distributor and reseller records indicate market availability, but quantities and timing can vary by channel, package format, order volume, and date. When requesting a quotation, identify the standard SY89467UHY ordering code, the required delivery quantity, and whether tape-and-reel or another assembly format is needed so the supplier can confirm the exact supply position.

এর জন্য ইঞ্জিনিয়ারিং রেফারেন্স ডেটা SY89467UHY — তুলনা, ডিজাইন গাইডেন্স এবং কমপ্লায়েন্স তথ্য।

নির্বাচন গাইড

Choose the SY89467UHY when a high-speed design requires both a 2:1 differential input selection and as many as 20 LVPECL output copies from the selected clock. It is particularly compelling for FPGA, serial-interface, telecom, converter, and instrumentation clock trees that operate at frequencies up to 2 GHz and need Fail-Safe Input behavior during a failed DC input condition. The -TR suffix version, SY89467UHY-TR, offers the same documented terminal arrangement and core performance for a tape-and-reel production format. Neither option should be selected without confirming the manufacturer pinout, exposed-pad construction, termination values, and exact electrical limits. If the design needs only one or two outputs, does not require differential input multiplexing, or cannot support LVPECL interfaces, a simpler clock buffer may be more appropriate. If clock-source switching creates phase discontinuities, evaluate the receiving system before integrating the multiplexer.

বিকল্পের সাথে তুলনা

পারামিটার এই পণ্য SY89467UHY-TR
Brand Microchip Technology Microchip Technology
Package 64-TQFP exposed pad 64-TQFP exposed pad
Product Function 1:20 LVPECL fanout buffer with 2:1 differential input multiplexer 1:20 LVPECL fanout buffer with 2:1 differential input multiplexer
Maximum Clock Frequency 2 GHz 2 GHz
Input Configuration 2 differential inputs 2 differential inputs
Output Configuration 20 LVPECL outputs 20 LVPECL outputs
Fail-Safe Input Yes Yes

মূল পার্থক্যসমূহ

  • Combines source multiplexing and wide fanout in one clock-and-timing device (বনামSY89467UHY-TR)
  • Supports fault-constrained clock distribution (বনামSY89467UHY-TR)
  • Supports multiple clock destinations from one selected source (বনামSY89467UHY-TR)

ডিজাইন নোট

Implement the 64-TQFP exposed pad with the manufacturer's recommended land pattern, pad connection, and via arrangement. Treat the exposed pad as part of the electrical return network rather than adding thermal vias independently of the documented layout. Position input, output, and supply connections to minimize loop area, and preserve the intended LVPECL impedance on every high-speed trace.

Keep clock routes short, avoid unnecessary stubs, and use the exact input and output termination network specified by the manufacturer. Confirm differential pair geometry and single-ended LVPECL impedance against the final PCB stack-up. At the device's 2 GHz maximum frequency, connector launches, vias, and test pads can create reflections that compromise edge quality even when nominal trace length is acceptable.

Do not assume that selecting a failed clock input automatically produces a valid operating clock. Fail-Safe Input helps prevent metastable outputs when the selected source fails to a DC voltage, but system logic must detect the fault, select a healthy source, and confirm recovery. Also verify unused-output termination and control-pin states against the manufacturer pin-description table before releasing the PCB for production.

কমপ্লায়েন্স তথ্য

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
লিড ফ্রি
Unknown
হ্যালোজেন ফ্রি
Unknown
কনফ্লিক্ট মিনারেলস
Unknown

No explicit environmental, material, or automotive qualification declarations were identified in the cited product and distributor records. Confirm the current declarations with the manufacturer before regulatory or production release.

ডেটা যাচাই করা হয়েছে: 2026-11-05 — ডেটা XAIPART-এর কম্পোনেন্ট ইঞ্জিনিয়ারিং টিম দ্বারা যাচাই ও কিউরেট করা হয়েছে

সম্পর্কিত অনুসন্ধান

SY89467UHY datasheet SY89467UHY pinout SY89467UHY datasheet pdf SY89467UHY specifications SY89467UHY equivalent SY89467UHY replacement SY89467UHY drop-in replacement SY89467UHY vs SY89467UHY-TR SY89467UHY price SY89467UHY stock Microchip SY89467UHY SY89467UHY 2 GHz clock buffer SY89467UHY 64 TQFP pinout SY89467UHY LVPECL fanout SY89467UHY clock multiplexer

সম্পর্কিত কম্পোনেন্ট ও শর্তাবলী

Microchip Technology SY89467UHY SY89467UHY-TR SY89467U LVPECL clock fanout buffer clock multiplexer 2:1 differential input multiplexer 1:20 fanout Fail-Safe Input FSI clock-and-timing IC semiconductor 2 GHz clock 64-TQFP exposed pad TQFP package family surface-mount package LVPECL clock distribution FPGA clock distribution telecommunications clocking high-speed serial interface data-converter clocking metastability controlled-impedance routing
তাৎক্ষণিক বিলওয়াছে রেকোজিউইট
সম্পূর্ণ বিবরণ পূরণ করুন — আমাদের সেলস টিম 24 ঘণ্টার মধ্যে উত্তর দেবে
পার্ট নম্বর উৎপাদক প্যাকেজ QTY লক্ষ্যমূল্য প্রসারিত
✓
বিল প্রস্তুত করা হয়েছে!

আমরা ২৪ ঘণ্টার মধ্যে আপনার ইমেইলে প্রত্যুত্তর দেব

1
RFQ জমা হয়েছে
2
কোটেশন পাওয়া গেছে
3
অর্ডার দেওয়া হয়েছে
4
পেমেন্ট
5
শিপ করা হয়েছে
6
ডেলিভারি হয়েছে
RFQ বিবরণ দেখুন