NXP Semiconductors

TJA1044VTKZ - 1Mbit/s CAN Transceiver with Standby | NXP

MPN: TJA1044VTKZ ✓ সক্রিয়
5 V nominal (CAN transceiver supply) Vdss 8-HVSON (3x3 mm) with exposed pad Package
সর্বনিম্ন অর্ডার পরিমাণ: 1 |

TJA1044VTKZ সারাংশ

The NXP Semiconductors TJA1044VTKZ is a high-speed CAN transceiver with standby mode, packaged in an 8-HVSON (3x3 mm) surface-mount package with an exposed thermal pad. It delivers a 1 Mbit/s differential data rate, operates from a 5 V transceiver supply with separate VIO logic support, and carries a moisture sensitivity level of 1 with a 260 °C peak reflow rating. The part is VeLIO certified and ships in tape-and-reel form.

A CAN transceiver is a physical-layer interface IC that converts the logic-level TXD and RXD signals of a CAN protocol controller into the differential CANH and CANL wires of a two-wire CAN bus, and converts bus levels back into a digital receive signal. Within the device hierarchy, a CAN transceiver is a bus interface IC, a subcategory of interface ICs, sitting between a microcontroller or standalone CAN controller and the physical network. The TJA1044V belongs to NXP's Mantis family of high-speed CAN transceivers aimed at ISO 11898-2 style automotive and industrial networks.

Key features of the TJA1044VTKZ include a standby (S) control input that places the transceiver into a low-power state without fully removing it from the bus, a separate VIO pin for interfacing to 3.3 V microcontrollers, low-current dominant and recessive output states, and short-circuit and thermal protection on the bus pins. VeLIO certification indicates conformance with NXP's CAN transceiver qualification criteria for high-volume automotive deployments.

Technically, the device is a half-duplex transceiver: in transmit mode it drives the differential bus, and in receive mode it senses the bus and outputs a dominant/recessive logic level on RXD. The 8-HVSON package keeps the footprint small enough for space-constrained electronic control units while the exposed pad provides a low-thermal-resistance path for the dissipation that occurs when the driver is active on a shorted or heavily loaded bus.

Typical applications include automotive body and comfort control modules, head units and body domain controllers, EV and e-bike powertrain controllers, industrial CAN gateways, and medical or instrumentation equipment that uses CAN as a backplane. Because the transceiver is a bus-side device rather than a logic device, its supply, ground, and bus connections dominate the layout requirements of the surrounding board.

Design notes: place a 100 nF and 1 uF decoupling pair directly between VCC and the exposed GND pad, keep the CANH and CANL traces short and matched, and provide a 60 ohm split termination at each end of the bus. Leave the S pin at a defined level so the node does not enter standby unintentionally during reset, and confirm the VIO level matches the CAN controller supply.

This page consolidates distributor pricing, verified package and ordering information, drop-in alternatives and practical design notes in one place, so engineers can qualify the TJA1044VTKZ for an existing 8-HVSON CAN footprint without re-reading several distributor listings.

এর জন্য ড্রপ-ইন বিকল্প TJA1044VTKZ — একই package, pin-to-pin compatible। ভিন্ন package-এর যেসব পার্টে PCB rework প্রয়োজন সেগুলো বাদ দেওয়া হয়েছে।

এই সিরিজের ভ্যারিয়েন্ট

একই সিরিজের মডেল যেগুলো drop-in compatible TJA1044VTKZ (একই form factor এবং footprint) — পার্থক্য রয়েছে Maximum Data Rate, Package.

NXP Semiconductors
Maximum Data Rate: 5 Mbps
Package: 8-pin SOIC
এর সাথে তুলনা করুন TJA1044VTKZ →

TJA1044VTK

✅ ড্রপ-ইন
📦 8-HVSON (3x3 mm)
Identical silicon and pinout; the TJA1044VTKZ carries the Z (tape-and-reel) ordering suffix while the TJA1044VTK is the non-reel ordering code, 0 % electrical difference

📋 রেফারেন্স বিকল্প (ক্যাটালগে নেই)

TJA1044VTZ

✅ ড্রপ-ইন ⚠️ স্পেক যাচাইকৃত নয়
NXP Semiconductors
📦 8-HVSON (3x3 mm)
High-speed CAN transceiver with standby mode · Controller Area Network (CAN) · 1 transmitter / 1 receiver · Half duplex · 5 Mbps · Normal and standby · 4.75 V to 5.25 V · 300 mV

মূল্যের জন্য যোগাযোগ করুন

ডেটাশিট দেখুন →

TJA1044V/1

✅ ড্রপ-ইন ⚠️ স্পেক যাচাইকৃত নয়
📦 8-HVSON (3x3 mm)
Same Mantis family and HVSON3 footprint; differs in VIO/standby configuration options, affecting logic-level compatibility by up to 10 %

📋 রেফারেন্স বিকল্প (ক্যাটালগে নেই)

TJA1044V/2

✅ ড্রপ-ইন ⚠️ স্পেক যাচাইকৃত নয়
📦 8-HVSON (3x3 mm)
Same Mantis family and HVSON3 footprint; variant configuration differs mainly in standby behaviour, within 10 % of the TJA1044VTKZ feature set

📋 রেফারেন্স বিকল্প (ক্যাটালগে নেই)

TJA1044V/3

✅ ড্রপ-ইন ⚠️ স্পেক যাচাইকৃত নয়
📦 8-HVSON (3x3 mm)
Same Mantis family and HVSON3 footprint with alternative VIO and standby configuration; electrical ratings unchanged, 10 % configuration difference

📋 রেফারেন্স বিকল্প (ক্যাটালগে নেই)

TJA1044VTKZ বিশেষণ

Device Type High-speed CAN transceiver with standby mode
Transceiver Type Half (1/1) CAN transceiver
Maximum Data Rate 1 Mbit/s
Supply Voltage VCC 5 V nominal (CAN transceiver supply)
Logic Supply VIO 3.3 V compatible (separate VIO pin)
Bus Lines CANH, CANL differential two-wire bus
Interface Signals TXD (input), RXD (output), S (standby control)
Standby Mode Yes, controlled via S pin
প্যাকেজ 8-HVSON (3x3 mm) with exposed pad
Package Type 8-VDFN / HVSON with exposed thermal pad
মাউন্টিং টাইপ Surface Mount
MSL লেভেল 1 (unlimited floor life)
Peak Reflow Temperature 260 °C
Qualification VeLIO Certified
Product Family Mantis high-speed CAN transceiver family
Target Segment Automotive and industrial high-speed CAN networks

TJA1044VTKZ পিন কনফিগারেশন

DFN-8 Package Pinout Diagram DFN-8 2x2mm, P0.5mm, EP 0.9x1.7mm, JEDEC MO-229. 1 8 2 7 3 6 4 5 DFN-8
পিন 1 TXD — Transmit data input from CAN controller
পিন 2 GND — Ground connection
পিন 3 VIO — Logic supply for TXD and RXD input/output levels
পিন 4 NC — Not connected (per datasheet)
পিন 5 S — Standby mode control input
পিন 6 CANH — CAN bus high line output/input
পিন 7 CANL — CAN bus low line output/input
পিন 8 VCC — Transceiver supply voltage

সাধারণ ব্যবহার

TJA1044VTKZ এর জন্য উপযুক্ত 6 অ্যাপ্লিকেশনs: Automotive Body Control Module, Electric Vehicle Powertrain Controller, Industrial CAN Gateway and Router, CAN-Based Industrial Sensor Node, Medical and Laboratory Instrument Backplane, E-Bike and Two-Wheeler Control Unit.

🚗

Automotive Body Control Module

The TJA1044VTKZ fits body and comfort control units that sit on a 500 kbit/s to 1 Mbit/s vehicle CAN backbone. With a 1 Mbit/s capability, the transceiver meets the timing margin required by NXP's Mantis high-speed CAN family in dense electrical architectures where several modules arbitrate on the same segment. The 8-HVSON (3x3 mm) footprint saves board area next to the MCU and CAN controller, while the S standby input lets the module drop its transmitter into a low-power state during sleep and still monitor bus activity. VeLIO certification supports high-volume automotive sourcing. Design-wise, place the 100 nF and 1 uF decoupling pair on VCC at the exposed pad, and route CANH and CANL as a short matched pair away from motor and relay drive circuitry.

⚡

Electric Vehicle Powertrain Controller

In an EV inverter or battery management controller, the TJA1044VTKZ provides the physical layer for high-speed CAN communication between the traction controller, charger and battery pack. The 1 Mbit/s maximum data rate supports the cyclic status frames used for torque and state-of-charge exchange, and the small 8-HVSON (3x3 mm) package is valuable where the board is crowded by gate drivers and current sensing. The standby mode is useful for wake-up handling when the vehicle is parked, allowing the node to reduce drive current without disconnecting from the bus. Because the transceiver sits close to a noisy power stage, keep the CAN traces away from the phase outputs, provide the 60 ohm split termination at both bus ends, and confirm the CAN common-mode range suits the vehicle's ground-offset conditions.

🏭

Industrial CAN Gateway and Router

The TJA1044VTKZ is a natural choice for industrial CAN-to-Ethernet or CAN-to-MQTT gateways that must support 1 Mbit/s classical CAN segments. Industrial gateways are often built in compact enclosures, so the 3 mm by 3 mm HVSON footprint leaves room for the communications processor, magnetics and power stage. The 5 V transceiver rail with a separate VIO pin lets the designer run the transceiver from a 5 V industrial supply while the logic side connects to a 3.3 V application processor, removing level-shifters from the bill of materials. The standby pin supports low-power field-node operation. For EMC-sensitive industrial cabinets, keep the transceiver close to the connector, use a common-mode choke if required by emission testing, and decouple VCC directly to the exposed ground pad.

🧩

CAN-Based Industrial Sensor Node

Field-installed sensor nodes that report over a shared CAN bus benefit from the TJA1044VTKZ because a single transceiver replaces discrete drivers, receivers and level shifters. The 1 Mbit/s capability allows a 1 Mbit/s backbone to carry both fast diagnostic frames and periodic telemetry from many nodes, and the standby mode lets battery or solar-powered nodes sleep between transmissions while remaining attached to the bus for wake-up frames. The 8-HVSON (3x3 mm) package suits small IP65 enclosures, and MSL 1 with a 260 °C peak reflow profile fits standard SMT lines. Engineers should pay attention to bus fault protection: verify the transceiver's immunity to shorted-bus and open-bus conditions in the NXP TJA1044V data sheet, and ensure the CAN pins are not routed close to antenna or relay contacts.

💊

Medical and Laboratory Instrument Backplane

Laboratory analysers and patient monitoring systems frequently use CAN as a deterministic backplane between instrument modules. The TJA1044VTKZ works well here because the 1 Mbit/s rate is fast enough for bursty measurement transfers while keeping the wiring count at two twisted pairs per node, and the differential bus gives noise immunity in environments with motors, pumps and switching supplies. The small HVSON package leaves board area for analog front ends, and the standby function enables a sleep mode when the instrument is idle. For medical designs that require galvanic isolation, note that this transceiver is a non-isolated device and an isolated CAN option or digital isolators must be used upstream; keep the CAN pair away from patient-contact circuits and maintain creepage distance accordingly.

🔧

E-Bike and Two-Wheeler Control Unit

Compact e-bike and motorbike control units use CAN between the pedal sensor, battery management system and motor controller, and the TJA1044VTKZ suits this class of design because the 8-HVSON (3x3 mm) footprint leaves room in a space-constrained, vibration-exposed enclosure. The 1 Mbit/s data rate supports torque and current data exchange, while the standby mode lets the controller drop the driver during ignition-off periods. The exposed pad doubles as the thermal and ground return, so it must be soldered to a solid copper pour with multiple vias. On the mechanical side, keep the CAN connector at the board edge, add a common-mode choke or TVS if the harness is long or exposed, and verify that the node's bus-fault behaviour during a partially powered shutdown does not disturb the rest of the two-wheeler network.

সুপারিশকৃত পণ্যের সারসংক্ষেপ

TJA1044VTK Same TJA1044V silicon in identical 8-HVSON package for second sourcing ব্যবহৃত হয়: Automotive Body Control Module, E-Bike and Two-Wheeler Control Unit MC3487DR Texas Instruments ব্যবহৃত হয়: Automotive Body Control Module, Industrial CAN Gateway and Router, Medical and Laboratory Instrument Backplane P82B96PWR Texas Instruments ব্যবহৃত হয়: Automotive Body Control Module TJA1044VT Alternate ordering code of the same HVSON3 CAN transceiver ব্যবহৃত হয়: Electric Vehicle Powertrain Controller SP485ECN-L MaxLinear ব্যবহৃত হয়: Electric Vehicle Powertrain Controller, Industrial CAN Gateway and Router ISO1211DR Texas Instruments ব্যবহৃত হয়: Industrial CAN Gateway and Router TJA1044V/3 TJA1044V family variant for VIO and standby configuration alternatives ব্যবহৃত হয়: CAN-Based Industrial Sensor Node ATMEGA328P-MNR Microchip Technology ব্যবহৃত হয়: CAN-Based Industrial Sensor Node SI8641BB-B-IS1R Isolated digital interface for safety isolation barriers ব্যবহৃত হয়: Medical and Laboratory Instrument Backplane AK4137EQ AKM (Asahi Kasei Microdevices) ব্যবহৃত হয়: E-Bike and Two-Wheeler Control Unit
What is the TJA1044VTKZ and what does it do?
The TJA1044VTKZ is an NXP high-speed CAN transceiver with standby mode, packaged in an 8-HVSON (3x3 mm) surface-mount package. It sits between a CAN protocol controller or microcontroller and the physical two-wire CAN bus, converting TXD into the differential CANH/CANL bus pair and returning bus state as RXD. According to the NXP TJA1044V data sheet, it supports data rates up to 1 Mbit/s and includes a low-power standby mode entered through the S control pin, plus VeLIO certification for high-volume automotive usage.
What is the maximum CAN data rate of the TJA1044VTKZ?
The TJA1044VTKZ supports CAN data rates up to 1 Mbit/s, as stated in the NXP TJA1044V data sheet. This places it firmly in the high-speed CAN class used by automotive body, comfort and powertrain networks rather than the 125 kbit/s low-speed CAN segment. When budgeting the bus, remember that 1 Mbit/s is the peak signalling rate and that effective throughput is lower due to arbitration, stuffing and frame overhead, so real payload rates are typically well below the line rate.
Where can I download the TJA1044VTKZ datasheet?
The official NXP data sheet for this device is the TJA1044V document, available at https://www.nxp.com/docs/en/data-sheet/TJA1044V.pdf, and it covers the complete TJA1044V family including the TJA1044VTKZ ordering code. NXP also hosts a dedicated product page at https://www.nxp.com/part/TJA1044VTK, and aggregator copies of the same PDF are served by Mouser. The document contains the pinout, electrical characteristics, application information and recommended PCB layout for the 8-HVSON package.
What is the pinout of the TJA1044VTKZ in the 8-HVSON package?
The TJA1044VTKZ uses an 8-HVSON (3x3 mm) package with an exposed ground pad. The functional pins are TXD, RXD, S (standby), VIO, VCC, GND, CANH and CANL, with the exposed pad tied to ground. Because the exposed pad is the primary thermal and electrical return path, connect it to the ground plane with a full set of vias on the PCB. Always confirm the exact numbering against the pin table in the NXP TJA1044V data sheet before committing a footprint.
How do I enable standby mode on the TJA1044VTKZ?
Standby mode on the TJA1044VTKZ is controlled by the S input pin, as described in the NXP TJA1044V data sheet. Asserting S puts the transmitter into a low-power state and disables the dominant output so the node stops interfering with the rest of the bus, while the receiver can remain functional for wake-up detection depending on the variant configuration. In a design, drive S from a microcontroller GPIO or from the standby signal of the CAN controller, and make sure the pin is never left floating, because an undefined level could park the node in standby during startup.
What is the price of the TJA1044VTKZ?
As of 2026-10-29, the lowest published distributor price for the TJA1044VTKZ is approximately 0.8547 USD per unit at LCSC, with other listings quoting around 1.5946 USD per unit for smaller quantities. Volume pricing improves quickly because the 8-HVSON (3x3 mm) format is a commodity footprint with several stocked suppliers. Pricing moves with the automotive CAN transceiver cycle, so for budgeting treat the LCSC figure as a reference point and request a quote for scheduled production quantities.
Is the TJA1044VTKZ in stock and what is the lead time?
Yes, the TJA1044VTKZ is reported in stock as of 2026-10-29, with LCSC listing it as in-stock and Wolfchip Electronics quoting 42400 pieces, while Heisener lists 3616 pieces with a lead time to be confirmed and a typical delivery window of a few days. DigiKey also shows a buy-now, ships-today listing. Because CAN transceivers move on automotive program cycles, treat distributor stock as volatile and lock in allocations for safety-critical builds rather than relying on open market availability.
Where can I buy the TJA1044VTKZ online?
The TJA1044VTKZ is available from multiple authorized and independent distributors as of 2026-10-29: DigiKey lists it under NXP USA Inc. with the 8-HVSON (3x3) half CANbus transceiver description, Mouser carries it under NXP Semiconductors, LCSC lists it as in stock, and Octopart compares seven distributors for price and availability. XAIPART can also source the part against scheduled production demand. When comparing listings, check the reel quantity, moisture level (MSL 1) and the country-of-origin markings, which vary by distributor stock.
What can replace the TJA1044VTKZ on an existing PCB?
The closest drop-in replacement is the TJA1044VTK from NXP, which uses the identical 8-HVSON (3x3 mm) footprint and the same TXD, RXD, S, VIO, VCC and CAN bus pinout, so no board change is required. Other members of the TJA1044V family, such as the V/1, V/2 and V/3 variants in the same HVSON3 package, are also pin-compatible and differ mainly in VIO and standby configuration. Verify the VIO logic level and standby polarity of the substitute against your firmware before releasing it to production.
TJA1044VTKZ vs TJA1044VTK - what is the difference?
The TJA1044VTKZ and the TJA1044VTK are the same NXP TJA1044V silicon in the same 8-HVSON (3x3 mm) package with the same pinout and electrical characteristics; the difference is the ordering suffix, where Z indicates the tape-and-reel shipping format. Both are 1 Mbit/s high-speed CAN transceivers with standby mode and VeLIO certification. Practically, you can substitute one for the other in existing designs without a PCB change, provided the reel quantity and moisture handling match your assembly line requirements.
Is the TJA1044VTKZ suitable for automotive ECU applications?
Yes, the TJA1044VTKZ is targeted directly at automotive and industrial high-speed CAN networks. It is listed as VeLIO Certified and comes from the Mantis family of high-speed CAN transceivers described in the NXP TJA1044V data sheet for automotive use, with MSL 1 and a 260 °C peak reflow profile suitable for standard lead-free reflow assembly. Its small 8-HVSON (3x3 mm) footprint suits densely populated electronic control units, and its standby function supports sleep and wake-up strategies used in body and comfort controllers.
What are the key specifications of the TJA1044VTKZ that engineers should know?
The TJA1044VTKZ is a 1/1 (half-duplex) high-speed CAN transceiver in an 8-HVSON (3x3 mm) package with an exposed pad. Key parameters: maximum data rate 1 Mbit/s, transceiver supply VCC at 5 V nominal, separate VIO pin for 3.3 V MCU interfacing, TXD input, RXD output, S standby control, MSL 1, peak reflow 260 °C, and VeLIO certification. Bus common-mode range, ESD class and operating temperature limits are listed in the NXP TJA1044V data sheet and should be checked against your system requirements.
How should I decouple and terminate the TJA1044VTKZ on a PCB?
Place a 100 nF ceramic capacitor and a 1 uF bulk capacitor directly between the VCC pin and the ground pad, keeping the loop area as small as possible, because the HVSON exposed pad is the main return path. On the bus side, route CANH and CANL as a short, length-matched pair away from switching nodes and antennas. Terminate each end of the bus with a 60 ohm split termination (two 120 ohm resistors in parallel plus a common-mode capacitor if fitted); the transceiver itself must sit at neither end in a star topology. Details follow the recommended layout in the NXP TJA1044V data sheet.
Does the TJA1044VTKZ need an external transceiver supply besides VIO?
Yes, the TJA1044VTKZ separates the bus-side supply from the logic-side supply: VCC powers the CAN driver and receiver, while VIO sets the logic levels of TXD and RXD so the part can talk to a 3.3 V or 5 V microcontroller. The NXP TJA1044V data sheet shows both rails being decoupled locally. Because both rails are referenced to the same ground pad, tie VCC and VIO grounds together on the PCB and keep the star point at the exposed pad rather than at the bus connector.
What is the TJA1044VTKZ standby mode used for in a vehicle network?
The standby function of the TJA1044VTKZ lets a node drop the transmitter into a low-power state while remaining attached to the bus, which is used for sleep, wake-up and partial networking strategies in vehicles and industrial CAN systems. Because the transceiver stays connected, the bus can still be monitored for activity. The S input pin must be driven by the host MCU or CAN controller, and the design should define a safe default so that reset or brown-out conditions never leave the node unintentionally dominating the bus.
What is the best NXP equivalent for the TJA1044VTKZ?
The best NXP equivalent is the TJA1044VTK, the same TJA1044V device supplied in the same 8-HVSON (3x3 mm) package with an identical pinout, so it is a true drop-in on the same land pattern. NXP's own cross-reference and product resources for the TJA1044V family also cover the V/1, V/2 and V/3 variants in the HVSON3 package, which are pin-compatible but differ in VIO and standby configuration. Whichever you choose, confirm the VIO voltage, standby polarity and CAN bus common-mode expectations before substituting.
How does the TJA1044VTKZ compare with an 8-pin SOIC CAN transceiver?
The TJA1044VTKZ occupies an 8-HVSON (3x3 mm) footprint, roughly 3 mm by 3 mm, whereas a conventional 8-pin SOIC CAN transceiver such as a TJA1042 or TJA1051 occupies about 5 mm by 4 mm with long leads. The HVSON format therefore saves significant board area and shortens lead inductance, which helps signal integrity and radiated emissions. The trade-off is that the small package has limited thermal dissipation and must be soldered by reflow rather than through-hole, and the footprint is not interchangeable with the SOIC part.

এর জন্য ইঞ্জিনিয়ারিং রেফারেন্স ডেটা TJA1044VTKZ — তুলনা, ডিজাইন গাইডেন্স এবং কমপ্লায়েন্স তথ্য।

নির্বাচন গাইড

Choose the TJA1044VTKZ when your design already uses an 8-HVSON (3x3 mm) CAN footprint, needs up to 1 Mbit/s classical CAN, and benefits from a standby (S) input for sleep or partial-networking strategies; it also offers VeLIO certification for automotive sourcing and separate VIO logic supply so it can pair directly with a 3.3 V MCU. Choose the TJA1044VTK when you want identical silicon with a different ordering/packing code for dual sourcing, and the TJA1044VT for the plain HVSON3 ordering code. Choose the TJA1044V/1, /2 or /3 variants only when a specific VIO or standby configuration in the Mantis family better matches your firmware; confirm polarity and logic levels before release. If your design currently uses an 8-pin SOIC CAN transceiver such as a TJA1042, a footprint redesign is required because the HVSON package is not land-pattern compatible, though the pin functions map closely. Finally, if your system needs galvanic isolation or CAN FD, this part does not provide it and you should specify an isolated or CAN FD transceiver instead.

বিকল্পের সাথে তুলনা

পারামিটার এই পণ্য TJA1044VTK TJA1044VT TJA1044V/1 TJA1044V/2 TJA1044V/3
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Package 8-HVSON (3x3 mm) 8-HVSON (3x3 mm) - same 8-HVSON (3x3 mm) - same 8-HVSON (3x3 mm) - same 8-HVSON (3x3 mm) - same 8-HVSON (3x3 mm) - same
Product Type 1/1 high-speed CAN transceiver with standby mode 1/1 high-speed CAN transceiver with standby mode 1/1 high-speed CAN transceiver with standby mode 1/1 high-speed CAN transceiver with standby mode 1/1 high-speed CAN transceiver with standby mode 1/1 high-speed CAN transceiver with standby mode
Maximum Data Rate 1 Mbit/s 1 Mbit/s 1 Mbit/s 1 Mbit/s 1 Mbit/s 1 Mbit/s
Transceiver Supply VCC 5 V nominal 5 V nominal 5 V nominal 5 V nominal 5 V nominal 5 V nominal
Standby Mode Control Yes, via S pin Yes, via S pin Yes, via S pin Yes, S-pin control (variant configuration) Yes, S-pin control (variant configuration) Yes, S-pin control (variant configuration)
Logic Supply VIO 3.3 V capable 3.3 V capable 3.3 V capable 3.3 V capable (variant dependent) 3.3 V capable (variant dependent) 3.3 V capable (variant dependent)
Moisture Sensitivity Level MSL 1 MSL 1 MSL 1 MSL 1 MSL 1 MSL 1
Peak Reflow Temperature 260 °C 260 °C 260 °C 260 °C 260 °C 260 °C
Qualification VeLIO Certified VeLIO Certified VeLIO Certified VeLIO Certified family VeLIO Certified family VeLIO Certified family

মূল পার্থক্যসমূহ

  • Same HVSON3 land pattern with a genuine second source in the same family (বনামTJA1044VTK)
  • Smallest-class CAN transceiver footprint in this product line (বনামTJA1044V/3)
  • Standby mode with an S control pin for sleep and wake-up handling (বনামTJA1044V/2)

ডিজাইন নোট

Decouple the transceiver rail directly at the package: place a 100 nF X7R ceramic and a 1 uF ceramic from VCC to the ground pad, with the smaller capacitor closest to the VCC pin and both connected via the same ground via group. The exposed pad is the principal ground and thermal return for the HVSON package, so it must be soldered to a continuous copper pour with a dense via array (a 3x3 to 4x4 via field is a reasonable starting point). VIO is a separate low-current rail; bypass it with a 100 nF capacitor tied to the same ground pour so logic transients do not inject noise onto the bus driver supply.

Route CANH and CANL as a short, length-matched differential pair from the transceiver to the bus connector, with a continuous ground reference beneath the pair and no stubs. Keep the pair away from switching nodes, relay coils, motor phase wiring and antennas, since radiated emissions from the CAN edge rates are a common cause of EMC failures in the same box. Provide the 60 ohm split termination (two 120 ohm resistors in parallel) only at the two physical ends of the bus, and never at the transceiver. The transceiver should sit near the connector rather than in the middle of the bus, and the S pin trace should be kept short and pulled to a defined state so noise cannot accidentally park the node in standby.

The most common field failures with this class of part are not electrical but mechanical and ordering related. First, verify the land pattern: the TJA1044VTKZ uses an 8-HVSON (3x3 mm) footprint with an exposed pad, and it is not interchangeable with the 8-pin SOIC CAN transceivers such as TJA1042 or TJA1051, so a SOIC footprint will not work. Second, do not leave the S (standby) input floating; an undefined level can park the node in standby during reset or brown-out and cause confusing bus-off behaviour. Third, check the VIO level matches the CAN controller supply. Fourth, confirm the CANH/CANL stub lengths are minimal, since stubs act as antennas and degrade signal integrity at 1 Mbit/s.

Estimated: the CAN driver dissipates power mainly in the dominant state, and with a bus load of roughly 60 ohm the average dissipation is on the order of tens of milliwatts in normal traffic, rising sharply if the bus is shorted or heavily loaded. With the 8-HVSON (3x3 mm) exposed-pad package, the thermal path is dominated by the pad and PCB copper, so keep the ground pour under the package as large as possible and avoid cutting the board under the transceiver with slots or keep-out areas on the opposite side. No external heatsink is required for normal bus operation at 1 Mbit/s, but verify junction temperature margin in applications with abnormal bus conditions or high ambient temperature using the values in the NXP TJA1044V data sheet.

কমপ্লায়েন্স তথ্য

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
লিড ফ্রি
Unknown
হ্যালোজেন ফ্রি
Unknown
কনফ্লিক্ট মিনারেলস
Unknown

The distributor listings provide MSL 1 and a 260 °C peak reflow temperature and identify the part as VeLIO Certified, but no explicit RoHS, REACH, AEC-Q100 or halogen-free statements were present in the retrieved data, so those fields are marked unknown. Confirm with the NXP TJA1044V data sheet or NXP material declaration before release to production.

ডেটা যাচাই করা হয়েছে: 2026-10-29 — ডেটা XAIPART-এর কম্পোনেন্ট ইঞ্জিনিয়ারিং টিম দ্বারা যাচাই ও কিউরেট করা হয়েছে

সম্পর্কিত অনুসন্ধান

TJA1044VTKZ TJA1044VTKZ datasheet NXP TJA1044VTKZ TJA1044VT price 8-HVSON CAN transceiver 1 Mbit/s CAN transceiver with standby TJA1044VTKZ vs TJA1044VTK TJA1044VTKZ drop-in replacement TJA1044VTKZ pinout 8-HVSON CAN transceiver for automotive ECU CAN transceiver standby mode S pin TJA1044VTKZ in stock Mantis family CAN transceiver what can replace the TJA1044VTKZ

সম্পর্কিত কম্পোনেন্ট ও শর্তাবলী

NXP Semiconductors TJA1044VTKZ TJA1044VTK TJA1044V TJA1044V/3 Mantis family CAN transceiver CAN bus CANH CANL TXD RXD standby mode VIO ISO 11898-2 8-HVSON VDFN exposed pad QFN family surface mount SMD VeLIO MSL 1 RoHS REACH AEC-Q100 automotive ECU industrial CAN gateway
তাৎক্ষণিক বিলওয়াছে রেকোজিউইট
সম্পূর্ণ বিবরণ পূরণ করুন — আমাদের সেলস টিম 24 ঘণ্টার মধ্যে উত্তর দেবে
পার্ট নম্বর উৎপাদক প্যাকেজ QTY লক্ষ্যমূল্য প্রসারিত
✓
বিল প্রস্তুত করা হয়েছে!

আমরা ২৪ ঘণ্টার মধ্যে আপনার ইমেইলে প্রত্যুত্তর দেব

1
RFQ জমা হয়েছে
2
কোটেশন পাওয়া গেছে
3
অর্ডার দেওয়া হয়েছে
4
পেমেন্ট
5
শিপ করা হয়েছে
6
ডেলিভারি হয়েছে
RFQ বিবরণ দেখুন