ICL7106RCPL - 3.5-Digit LCD A/D Converter | Analog Devices
MPN: ICL7106RCPL ✓ چالاکICL7106RCPL گشتی
A 3.5-digit A/D converter is a dedicated data-acquisition IC that converts an analog voltage into a digital value suitable for direct display or downstream processing. The ICL7106 belongs to the successive-integration ADC family and integrates the functions normally distributed across a converter, display interface, reference, and timing circuit. This integration reduces component count in panel meters, laboratory instruments, and portable measurement equipment.
The device includes a seven-segment decoder and multiplexed LCD backplane drive. Its true differential input arrangement is particularly useful for ratiometric measurements because the input is evaluated relative to the reference voltage. A zero-integrator phase added to the ICL7106 and ICL7107 reduces overrange hangover and hysteresis effects, improving recovery after an out-of-range conversion. The manufacturer describes the converter as low power.
The ICL7106 integrates the converter, reference, clock, decoder, and display drivers in one package. This architecture allows a measurement circuit to use an LCD rather than a bank of discrete display drivers. Because the package is a 40-pin PDIP, it is intended for through-hole instrumentation rather than compact surface-mount products. The C suffix and exact operating limits should be checked against the manufacturer datasheet before production release.
Typical uses include digital panel meters, thermometers, laboratory meters, bridge-based instrumentation, and portable instruments with LCD readouts. For bridge or resistance measurements, ratiometric operation helps reject reference drift. For applications requiring direct LED display drive, the ICL7107 is the related family member designed for instrument-size LED displays.
The primary design consideration is PCB area and through-hole assembly rather than thermal management. Follow the datasheet input-filtering, reference, integration, clock, and display-component recommendations. Because the LCD drive is multiplexed, display glass characteristics and segment mapping also influence readability and timing.
This page combines the manufacturer family information, exact-MPN sourcing data, verified package identification, and pin-compatible replacement analysis. It also organizes application guidance and the design checks that matter when adapting this legacy through-hole converter into a new measurement instrument.
جێگرەوەکانی جێگۆڕکێ بۆ ICL7106RCPL — هەمان پاکەت، پین بە پین گونجاو. ئەو بەشانەی پاکەتی جیاوازیان هەیە و پێویستیان بە چاککردنەوەی PCB هەیە لابراون.
جۆرەکان لەم زنجیرەیەدا
مۆدێلەکانی هەمان زنجیرە کە بە شێوەی ڕاستەوخۆ گونجاون لەگەڵ ICL7106RCPL (هەمان شێوە و پێکهاتەی شوێن) — جیاوازە لە Conversion Architecture, Input Configuration, Input Impedance, Integrated Clock, Integrated Reference.
ICL7106CPL+
✅ جێگرەوەی ڕاستەوخۆپەیوەندی بۆ نرخ
بینینی داتاشیت →ICL7106RCPL زۆرترین ڕێژە و تایبەتمەندییە کارەباییەکان
| ADC Resolution | 3.5 digits |
| Conversion Architecture | Successive integration |
| Technology | CMOS |
| Input Configuration | True differential |
| Reference Configuration | True differential |
| Display Type | Multiplexed liquid crystal display |
| Integrated Display Decoder | Seven-segment decoder |
| Integrated Clock | Yes |
| Integrated Reference | Yes |
| پاکێج | 40-pin PDIP |
| جۆری دامەزراندن | Through-hole |
| Power Classification | Low power |
| Overrange Recovery | Zero-integrator phase |
| دۆخی RoHS | Compliant |
ڕێنمایی ڕێکخستنی پینی ICL7106RCPL 40-pin pdip
ڕێکخستنی پین بۆ ICL7106RCPL (پاکێجی 40-pin pdip). ئەم پێکھاتە ئەنالۆگە پینی چوونەژوورەوە، دەرچوون و دابینکردنی وزەی ھەیە. سەرنج بدە بە داتاشیتی بەرھەمھێنەر بۆ ڕێکخستنەکانی پینی لادانی ئۆفسێت، قەرەبووکردنەوە و چالاککردن. گونجاوە بۆ ڕێکخستنی ئیشارەت و خولەکانی بەرزکەرەوە.
هیچ داتای وردی پینئاوت بەردەست نییە بۆ ICL7106RCPL.
سەرنج بدە بە داتاشیت بۆ ڕێکخستنی تەواوی پینەکان.
بەکارهێنانە باوەکان
ICL7106RCPL گونجاوە بۆ 6 بەکارھێنانs: Digital Panel Meter, Digital Thermometer, Laboratory Voltage Meter, Bridge Transducer Instrumentation, Portable Resistance Meter, Industrial Process Readout.
Digital Panel Meter
The ICL7106RCPL fits a digital panel meter because it combines a 3.5-digit A/D converter, seven-segment decoder, reference, clock, and multiplexed LCD driver in one 40-pin PDIP package. This integration reduces the number of separate display-interface components required for a compact meter. The LCD backplane and segment outputs can drive a suitable multiplexed glass display, while the converter produces a directly displayable result. Designers should confirm the display waveform, segment mapping, and timing against the datasheet before PCB release.
پێشنیارکراو
Digital Thermometer
A thermometer can use the ICL7106RCPL when the sensing element produces an analog voltage that fits the converter's measurement range. The 3.5-digit result is appropriate for displaying a temperature with limited resolution, and the integrated LCD drive supports a compact handheld format. The key engineering task is scaling and conditioning the sensor signal so it remains within the input limits while preserving useful resolution. Input filtering, reference stability, and the conversion interval must be selected from the manufacturer guidance.
پێشنیارکراو
Laboratory Voltage Meter
The ICL7106RCPL is suitable for a laboratory voltage-meter front end that prioritizes a simple display readout over a high-speed sampling architecture. Its integrated reference, clock, seven-segment decoder, and LCD backplane drive provide the major functions needed around a conditioned input. The instrument can present a stable 3.5-digit result on multiplexed LCD glass while keeping the external analog network focused on scaling, filtering, and input protection. Calibration should account for reference accuracy and the true differential input arrangement.
پێشنیارکراو
Bridge Transducer Instrumentation
The ICL7106RCPL is particularly appropriate for bridge or resistance measurements because the manufacturer identifies true differential input and reference terminals as useful for ratiometric operation. In such a system, the output depends on the ratio of the measured quantity to the reference rather than on absolute reference voltage alone. This architecture can reduce sensitivity to reference drift in precision thermometry, load-cell front ends, and portable ohmmeters. Component matching and amplifier or network design remain essential because the converter cannot correct an unbalanced bridge or unwanted noise at the input.
پێشنیارکراو
Portable Resistance Meter
The ICL7106RCPL can serve as the display-processing core of a portable resistance meter because it provides 3.5-digit conversion and integrated LCD drive in a single through-hole package. The instrument can measure a ratiometric bridge or resistance network and show the result directly, avoiding a separate display driver. Battery operation benefits from the family's low-power positioning, but total current must include the LCD load and external reference network. The design should also provide input protection and account for contact resistance in low-value measurements.
پێشنیارکراو
Industrial Process Readout
An industrial process readout can use the ICL7106RCPL when the measured signal is slow enough for a display-oriented converter and the enclosure uses a standard LCD. The integrated decoder and multiplexed backplane drive simplify the instrument architecture, while the 40-pin PDIP supports through-hole construction on a large controller board. A protected analog front end should scale the process voltage into the converter's input range. Verify the exact suffix's temperature limits for the operating environment and validate isolation, grounding, and noise performance at the interface.
پێشنیارکراو
کورتەی بەرهەمە پێشنیارکراوەکان
داتای سەرچاوەی ئەندازیاری بۆ ICL7106RCPL — بەراوردکردن، ڕێنمایی دیزاین و زانیاری پابەندبوون.
ڕێنمایی هەڵبژاردن
بەراوردکردن لەگەڵ جێگرەوەکان
| پارامەتر | ئەم بەرهەمە | ICL7106CPL |
|---|---|---|
| Package | 40-pin PDIP | 40-pin PDIP |
| Brand | Analog Devices | Renesas Electronics |
| ADC Resolution | 3.5 digits | 3.5 digits |
| Technology | CMOS | CMOS |
| Display Output | Multiplexed LCD drive | Multiplexed LCD drive |
| Input Type | True differential | True differential |
| Reference Type | True differential | True differential |
| Integrated Functions | Seven-segment decoder, LCD driver, reference, and clock | Seven-segment decoder, LCD driver, reference, and clock |
| Lifecycle Status | Production family; exact RCPL suffix requires quotation confirmation | Active listing |
جیاکەرەوە سەرەکییەکان
- Complete LCD-oriented converter integration (بەراورد بەICL7107CPL)
- True differential measurement architecture (بەراورد بەICL7106CPL)
- Exact production-family sourcing path (بەراورد بەICL7106CPL)
تێبینییەکانی دیزاین
Use the 40-pin PDIP footprint and assign every net from the ICL7106RCPL pin-description table. Place the input-filtering components, reference components, integration-network parts, clock components, and display connections according to the manufacturer application guidance. Incorrect peripheral values can affect conversion timing, noise rejection, or LCD readability even when the IC and display are pin-compatible.
Protect the differential input from switching noise and electrostatic discharge before it reaches the converter. Keep the analog input path compact, use a stable reference arrangement, and follow the recommended input-filter topology. Ratiometric operation can reduce the effect of reference drift, but it does not remove errors caused by an unbalanced bridge, parasitic leakage, or poorly matched network components.
Do not substitute an ICL7107-family device into an ICL7106 LCD design without redesigning the display interface. The ICL7107 family directly drives LED displays, whereas the ICL7106 uses multiplexed LCD backplane drive. Also confirm operating-temperature grade and supply limits for the exact RCPL suffix before approving it for industrial or battery-powered equipment.
زانیاری پابەندبوون
The exact-MPN sourcing record marks ICL7106RCPL as RoHS compliant. Other compliance declarations are not established by the available records.