ICL7106RCPL - 3.5-Digit LCD A/D Converter | Analog Devices
MPN: ICL7106RCPL ✓ Hoạt độngICL7106RCPL Tóm tắt
A 3.5-digit A/D converter is a dedicated data-acquisition IC that converts an analog voltage into a digital value suitable for direct display or downstream processing. The ICL7106 belongs to the successive-integration ADC family and integrates the functions normally distributed across a converter, display interface, reference, and timing circuit. This integration reduces component count in panel meters, laboratory instruments, and portable measurement equipment.
The device includes a seven-segment decoder and multiplexed LCD backplane drive. Its true differential input arrangement is particularly useful for ratiometric measurements because the input is evaluated relative to the reference voltage. A zero-integrator phase added to the ICL7106 and ICL7107 reduces overrange hangover and hysteresis effects, improving recovery after an out-of-range conversion. The manufacturer describes the converter as low power.
The ICL7106 integrates the converter, reference, clock, decoder, and display drivers in one package. This architecture allows a measurement circuit to use an LCD rather than a bank of discrete display drivers. Because the package is a 40-pin PDIP, it is intended for through-hole instrumentation rather than compact surface-mount products. The C suffix and exact operating limits should be checked against the manufacturer datasheet before production release.
Typical uses include digital panel meters, thermometers, laboratory meters, bridge-based instrumentation, and portable instruments with LCD readouts. For bridge or resistance measurements, ratiometric operation helps reject reference drift. For applications requiring direct LED display drive, the ICL7107 is the related family member designed for instrument-size LED displays.
The primary design consideration is PCB area and through-hole assembly rather than thermal management. Follow the datasheet input-filtering, reference, integration, clock, and display-component recommendations. Because the LCD drive is multiplexed, display glass characteristics and segment mapping also influence readability and timing.
This page combines the manufacturer family information, exact-MPN sourcing data, verified package identification, and pin-compatible replacement analysis. It also organizes application guidance and the design checks that matter when adapting this legacy through-hole converter into a new measurement instrument.
Bộ thay thế dễ dàng lắp đặt cho ICL7106RCPL — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.
Các biến thể trong loạt này
Các mẫu cùng loạt có thể lắp đặt dễ dàng tương thích với ICL7106RCPL (cùng hình factor và footprint) — khác nhau ở Conversion Architecture, Input Configuration, Input Impedance, Integrated Clock, Integrated Reference.
ICL7106CPL+
✅ Drop-InLiên hệ để biết giá
Xem tài liệu →ICL7106RCPL Tỷ lệ tối đa & tính chất điện
| ADC Resolution | 3.5 digits |
| Conversion Architecture | Successive integration |
| Technology | CMOS |
| Input Configuration | True differential |
| Reference Configuration | True differential |
| Display Type | Multiplexed liquid crystal display |
| Integrated Display Decoder | Seven-segment decoder |
| Integrated Clock | Yes |
| Integrated Reference | Yes |
| Hộp | 40-pin PDIP |
| Kiểu lắp đặt | Through-hole |
| Power Classification | Low power |
| Overrange Recovery | Zero-integrator phase |
| Trạng thái RoHS | Compliant |
Hướng dẫn cấu hình chân ICL7106RCPL 40-pin pdip
Cấu hình chân cho ICL7106RCPL (40-pin pdip gói). Thành phần số hiệu này có chân đầu vào, đầu ra và nguồn cung cấp. Tham khảo tài liệu thông số kỹ thuật của nhà sản xuất để biết cấu hình chân bù, bù trừ và chân kích hoạt. Hoàn hảo cho điều kiện tín hiệu và mạch khuếch đại.
Không có dữ liệu chân cụ thể sẵn có cho ICL7106RCPL.
Tham khảo: tài liệu kỹ thuật cho cấu hình chân đầy đủ.
Ứng dụng tiêu biểu
ICL7106RCPL phù hợp cho 6 Áp dụngs: Digital Panel Meter, Digital Thermometer, Laboratory Voltage Meter, Bridge Transducer Instrumentation, Portable Resistance Meter, Industrial Process Readout.
Digital Panel Meter
The ICL7106RCPL fits a digital panel meter because it combines a 3.5-digit A/D converter, seven-segment decoder, reference, clock, and multiplexed LCD driver in one 40-pin PDIP package. This integration reduces the number of separate display-interface components required for a compact meter. The LCD backplane and segment outputs can drive a suitable multiplexed glass display, while the converter produces a directly displayable result. Designers should confirm the display waveform, segment mapping, and timing against the datasheet before PCB release.
Được đề xuất
Digital Thermometer
A thermometer can use the ICL7106RCPL when the sensing element produces an analog voltage that fits the converter's measurement range. The 3.5-digit result is appropriate for displaying a temperature with limited resolution, and the integrated LCD drive supports a compact handheld format. The key engineering task is scaling and conditioning the sensor signal so it remains within the input limits while preserving useful resolution. Input filtering, reference stability, and the conversion interval must be selected from the manufacturer guidance.
Được đề xuất
Laboratory Voltage Meter
The ICL7106RCPL is suitable for a laboratory voltage-meter front end that prioritizes a simple display readout over a high-speed sampling architecture. Its integrated reference, clock, seven-segment decoder, and LCD backplane drive provide the major functions needed around a conditioned input. The instrument can present a stable 3.5-digit result on multiplexed LCD glass while keeping the external analog network focused on scaling, filtering, and input protection. Calibration should account for reference accuracy and the true differential input arrangement.
Được đề xuất
Bridge Transducer Instrumentation
The ICL7106RCPL is particularly appropriate for bridge or resistance measurements because the manufacturer identifies true differential input and reference terminals as useful for ratiometric operation. In such a system, the output depends on the ratio of the measured quantity to the reference rather than on absolute reference voltage alone. This architecture can reduce sensitivity to reference drift in precision thermometry, load-cell front ends, and portable ohmmeters. Component matching and amplifier or network design remain essential because the converter cannot correct an unbalanced bridge or unwanted noise at the input.
Được đề xuất
Portable Resistance Meter
The ICL7106RCPL can serve as the display-processing core of a portable resistance meter because it provides 3.5-digit conversion and integrated LCD drive in a single through-hole package. The instrument can measure a ratiometric bridge or resistance network and show the result directly, avoiding a separate display driver. Battery operation benefits from the family's low-power positioning, but total current must include the LCD load and external reference network. The design should also provide input protection and account for contact resistance in low-value measurements.
Được đề xuất
Industrial Process Readout
An industrial process readout can use the ICL7106RCPL when the measured signal is slow enough for a display-oriented converter and the enclosure uses a standard LCD. The integrated decoder and multiplexed backplane drive simplify the instrument architecture, while the 40-pin PDIP supports through-hole construction on a large controller board. A protected analog front end should scale the process voltage into the converter's input range. Verify the exact suffix's temperature limits for the operating environment and validate isolation, grounding, and noise performance at the interface.
Được đề xuất
Tóm tắt các sản phẩm được đề xuất
Dữ liệu tham khảo kỹ thuật cho ICL7106RCPL — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.
Hướng dẫn chọn lựa
So sánh với các sản phẩm thay thế
| Tham số | Sản phẩm này | ICL7106CPL |
|---|---|---|
| Package | 40-pin PDIP | 40-pin PDIP |
| Brand | Analog Devices | Renesas Electronics |
| ADC Resolution | 3.5 digits | 3.5 digits |
| Technology | CMOS | CMOS |
| Display Output | Multiplexed LCD drive | Multiplexed LCD drive |
| Input Type | True differential | True differential |
| Reference Type | True differential | True differential |
| Integrated Functions | Seven-segment decoder, LCD driver, reference, and clock | Seven-segment decoder, LCD driver, reference, and clock |
| Lifecycle Status | Production family; exact RCPL suffix requires quotation confirmation | Active listing |
Bảo phân biệt quan trọng
- Complete LCD-oriented converter integration (vsICL7107CPL)
- True differential measurement architecture (vsICL7106CPL)
- Exact production-family sourcing path (vsICL7106CPL)
Ghi chú thiết kế
Use the 40-pin PDIP footprint and assign every net from the ICL7106RCPL pin-description table. Place the input-filtering components, reference components, integration-network parts, clock components, and display connections according to the manufacturer application guidance. Incorrect peripheral values can affect conversion timing, noise rejection, or LCD readability even when the IC and display are pin-compatible.
Protect the differential input from switching noise and electrostatic discharge before it reaches the converter. Keep the analog input path compact, use a stable reference arrangement, and follow the recommended input-filter topology. Ratiometric operation can reduce the effect of reference drift, but it does not remove errors caused by an unbalanced bridge, parasitic leakage, or poorly matched network components.
Do not substitute an ICL7107-family device into an ICL7106 LCD design without redesigning the display interface. The ICL7107 family directly drives LED displays, whereas the ICL7106 uses multiplexed LCD backplane drive. Also confirm operating-temperature grade and supply limits for the exact RCPL suffix before approving it for industrial or battery-powered equipment.
Thông tin tuân thủ
The exact-MPN sourcing record marks ICL7106RCPL as RoHS compliant. Other compliance declarations are not established by the available records.