INA114BP - 1MHz Precision Instrumentation Amplifier | TI
MPN: INA114BP ✓ چالاکINA114BP گشتی
An instrumentation amplifier is a specialized amplifier category designed to extract a small differential voltage while rejecting common-mode interference. Its internal three-op-amp architecture provides high input impedance and precise gain control, making it more effective than ordinary operational amplifiers in many sensor-front-end applications. Within the signal-chain hierarchy, it belongs to the broader family of amplifier ICs and analog signal-conditioning components.
Key features include 11 nV/sqrt(Hz) input noise, 115 dB minimum common-mode rejection, 2 nA maximum input bias current, and 0.25 uV/degree C maximum input offset drift. The low offset voltage and drift reduce measurement errors in bridge, strain-gauge, and low-level current sensing systems. Internal input protection supports +/-40 V, helping the device tolerate transient overloads encountered outside the normal operating input range.
The INA114 uses a versatile three-op-amp signal chain and accepts single or dual supply operation. Its gain is established with one external resistor, allowing a single circuit implementation to cover gain settings from 1 to 10,000. The 1 MHz bandwidth supports dynamic sensor signals while remaining appropriate for precision industrial instrumentation rather than very high-frequency signal extraction.
Typical uses include 4-20 mA current-loop receivers, strain-gauge bridge amplifiers, isolated-signal front ends, precision current-shunt measurements, biomedical instrumentation, and laboratory measurement equipment. The device is particularly useful when the wanted differential signal is small relative to ground offsets or common-mode noise present at the input connectors.
When designing the input stage, use an external gain resistor with suitable stability and thermal characteristics, keep input traces short, and connect the reference pin to a clean analog ground when unity gain is required. Check input common-mode range and output swing at every supply voltage before selecting the final gain, because bandwidth and output capability change with operating conditions.
This page combines the device's precision specifications, application guidance, package information, replacement analysis, and practical design considerations to support faster component evaluation and more reliable front-end design.
جێگرەوەکانی جێگۆڕکێ بۆ INA114BP — هەمان پاکەت، پین بە پین گونجاو. ئەو بەشانەی پاکەتی جیاوازیان هەیە و پێویستیان بە چاککردنەوەی PCB هەیە لابراون.
جۆرەکان لەم زنجیرەیەدا
مۆدێلەکانی هەمان زنجیرە کە بە شێوەی ڕاستەوخۆ گونجاون لەگەڵ INA114BP (هەمان شێوە و پێکهاتەی شوێن) — جیاوازە لە Common-Mode Rejection Ratio, Gain Range, Input Bias Current.
INA114BPG4
✅ جێگرەوەی ڕاستەوخۆ📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)
INA114AP
✅ جێگرەوەی ڕاستەوخۆپەیوەندی بۆ نرخ
بینینی داتاشیت →INA111BP
✅ جێگرەوەی ڕاستەوخۆپەیوەندی بۆ نرخ
بینینی داتاشیت →INA114BP زۆرترین ڕێژە و تایبەتمەندییە کارەباییەکان
| Product Type | Precision instrumentation amplifier |
| Number of Amplifiers | 1 circuit |
| Architecture | Three-op-amp instrumentation amplifier |
| Gain Range | 1 to 10,000 |
| Gain-Bandwidth Product | 1 MHz |
| Input Noise | 11 nV/sqrt(Hz) |
| Input Offset Voltage | 50 uV maximum |
| Input Offset Drift | 0.25 uV/degree C maximum |
| Input Bias Current | 2 nA maximum |
| Common-Mode Rejection Ratio | 115 dB minimum |
| Input Overvoltage Protection | +/-40 V |
| ڤۆڵتیەی دابینکردن | +/-18 V maximum |
| ئێستای ئارام | 3 mA maximum |
| مەودای پلەی گەرمیی کارکردن | -40 degrees C to +85 degrees C |
| پاکێج | 8-pin PDIP |
| جۆری دامەزراندن | Through-hole |
| Gain Configuration | Single external resistor |
ڕێنمایی ڕێکخستنی پینی INA114BP 8-pin pdip
ڕێکخستنی پین بۆ INA114BP (پاکێجی 8-pin pdip). ئەم پێکھاتە ئەنالۆگە پینی چوونەژوورەوە، دەرچوون و دابینکردنی وزەی ھەیە. سەرنج بدە بە داتاشیتی بەرھەمھێنەر بۆ ڕێکخستنەکانی پینی لادانی ئۆفسێت، قەرەبووکردنەوە و چالاککردن. گونجاوە بۆ ڕێکخستنی ئیشارەت و خولەکانی بەرزکەرەوە.
هیچ داتای وردی پینئاوت بەردەست نییە بۆ INA114BP.
سەرنج بدە بە داتاشیت بۆ ڕێکخستنی تەواوی پینەکان.
بەکارهێنانە باوەکان
INA114BP گونجاوە بۆ 6 بەکارھێنانs: Precision Current-Shunt Measurement, Strain-Gauge Bridge Instrumentation, 4-20 mA Process-Control Receiver, Medical and Biomedical Signal Conditioning, Portable Sensor and IoT Interface, Precision Test and Measurement Front End.
Precision Current-Shunt Measurement
The INA114BP suits low-side current measurement when a small differential voltage across a shunt must be amplified in the presence of a much larger common-mode voltage. Its 115 dB minimum common-mode rejection reduces errors from supply and ground disturbances, while 2 nA maximum input bias current limits disturbance of the shunt network. A gain from 1 to 10,000 is available through one external resistor. Choose the gain so the expected load current produces useful output swing without clipping, and keep the shunt connections short to minimize added pickup. The 1 MHz bandwidth accommodates rapidly changing current, while the 50 uV maximum offset sets an important floor for low-current measurements.
پێشنیارکراو
Strain-Gauge Bridge Instrumentation
The INA114BP is appropriate for resistive strain-gauge bridges where the full-scale differential signal is small and the bridge midpoint can sit at a substantial common-mode voltage. Its 11 nV/sqrt(Hz) input noise and 0.25 uV/degree C maximum offset drift help preserve the integrity of millivolt-level measurements. The 1 to 10,000 gain range allows one amplifier topology to cover different bridge sensitivities. Use regulated bridge excitation, verify the input common-mode range under worst-case imbalance, and place the amplifier close to the bridge to avoid adding noise between the sensor and input pins.
پێشنیارکراو
4-20 mA Process-Control Receiver
The INA114BP can amplify the differential voltage produced by a 4-20 mA industrial transmitter while rejecting the common-mode voltage present on long field-wired loops. Its 115 dB minimum common-mode rejection and input protection to +/-40 V add useful robustness for industrial interfaces, although the normal operating range must still be respected. The external gain resistor lets the receiver establish the required scale factor and bandwidth without a complex resistor network. Place surge-protection components at the connector, keep their capacitance and leakage under control, and confirm that the selected gain remains compatible with the transmitter output at zero and full-scale current.
پێشنیارکراو
Medical and Biomedical Signal Conditioning
The INA114BP provides the differential input stage required for low-level biomedical transducers when the source includes large electrode or supply common-mode offsets. Its low input bias current of 2 nA maximum and 50 uV maximum offset voltage are useful for high-impedance sensor interfaces, while 11 nV/sqrt(Hz) input noise supports sensitive signal conditioning. The instrument-amplifier architecture reduces dependence on resistor matching in the input stage. In patient-connected equipment, however, system safety, isolation, leakage, and applicable regulatory requirements must be evaluated independently; the amplifier itself is not a complete medical interface solution.
پێشنیارکراو
Portable Sensor and IoT Interface
The INA114BP is useful in compact sensor interfaces that amplify a small differential output while rejecting battery-system noise and ground offsets. The 3 mA maximum quiescent current supports power-conscious instrumentation, and the 8-pin PDIP package simplifies through-hole prototyping and repair. A gain from 1 to 10,000 lets the same amplifier family serve resistive, magnetic, and current-sensing front ends. Because it is a through-hole package rather than a miniature surface-mount option, compare board area carefully against newer surface-mount instrumentation amplifiers. Confirm low-voltage common-mode range, output swing, noise, and overall standby current before finalizing a wearable or compact IoT design.
پێشنیارکراو
Precision Test and Measurement Front End
The INA114BP supports laboratory and production-test front ends that must resolve small differential signals with limited common-mode interference. Its 1 MHz bandwidth, 115 dB minimum common-mode rejection, and selectable gain are useful for conditioning bridge outputs, precision dividers, and diagnostic loops. The 50 uV maximum offset and 0.25 uV/degree C maximum drift establish important calibration limits, so system-level error budgets should include resistor tolerance, reference accuracy, and temperature. Use short guarded input traces, clean grounding, and an output ADC whose noise and input range complement the amplifier rather than limiting system accuracy.
پێشنیارکراو
کورتەی بەرهەمە پێشنیارکراوەکان
داتای سەرچاوەی ئەندازیاری بۆ INA114BP — بەراوردکردن، ڕێنمایی دیزاین و زانیاری پابەندبوون.
ڕێنمایی هەڵبژاردن
بەراوردکردن لەگەڵ جێگرەوەکان
| پارامەتر | ئەم بەرهەمە | INA114BPG4 | INA114AP | INA111BP |
|---|---|---|---|---|
| Package | 8-pin PDIP | 8-pin PDIP | 8-pin PDIP | 8-pin PDIP |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Product Type | Precision instrumentation amplifier | Instrumentation amplifier | Precision instrumentation amplifier | Instrumentation amplifier |
جیاکەرەوە سەرەکییەکان
- Wide programmable gain with one external resistor (بەراورد بەINA111BP)
- Documented precision offset and drift (بەراورد بەINA114AP)
- High common-mode rejection for differential sensing (بەراورد بەINA114BPG4)
تێبینییەکانی دیزاین
Route the differential input pair as a short, symmetric pair and keep them away from switching nodes and high-current return paths. Connect the gain-setting resistor directly to the appropriate pins, and place any input protection components close to the connector. Since the device specifies 11 nV/sqrt(Hz) input noise, unnecessary copper, breadboard wiring, and leakage can materially degrade the noise performance of a millivolt-level measurement.
Check the common-mode input range, output swing, and gain at the lowest operating supply voltage rather than checking only the nominal rail. The device supports single and dual supplies and has a stated maximum of +/-18 V. Use a supply arrangement that keeps every input node inside its common-mode range, including during startup and sensor-signal transitions. Bypass the supply pins locally with the capacitance recommended by the manufacturer datasheet.
Do not treat the +/-40 V input-protection rating as the normal operating input range. Protection helps against fault conditions, but excessive voltage can still produce unintended current, heating, or saturation. Also avoid assuming that identical package outlines guarantee a replacement: verify gain-resistor equations, reference-pin behavior, input limits, offset, noise, and common-mode rejection for the exact alternative ordering code.
زانیاری پابەندبوون
No explicit component compliance declarations were identified. Use the current Texas Instruments product and material-compliance documentation for production qualification.