KSZ8051RNL - 100BASE-TX Ethernet PHY | Microchip | Automotive
MPN: KSZ8051RNL ✓ چالاکKSZ8051RNL گشتی
An Ethernet physical-layer transceiver, commonly called an Ethernet PHY, converts between a digital MAC-facing interface and analog signals carried over twisted-pair Ethernet cabling. The KSZ8051RNL supports 10BASE-T and 100BASE-TX operation through an RMII connection to an Ethernet MAC or switch controller. Because RMII uses a parallel digital interface, it reduces the number of signal lines compared with MII while maintaining compatibility with common automotive Ethernet controller architectures. The 32-QFN package supports compact placement close to the Ethernet magnetics and connector.
The KSZ8051RNL includes integrated 10BASE-T on-chip termination resistors, as shown in the manufacturer system-block diagram, and supports management access through MDC and MDIO signals. Its 50 MHz RMII reference-clock arrangement allows the device to accept REF_CLK from the MAC or system board at XI and leaves the corresponding output as no connect. This makes clock planning an important part of RMII interface implementation. The manufacturer identifies the KSZ8051 as a highly integrated PHY intended to reduce board cost and simplify board layout.
Typical applications include automotive Ethernet infotainment systems, head units, domain controllers, vehicle gateways, telematics units, and industrial or embedded Ethernet equipment using 100BASE-TX links. The device can support low-power management and connectivity functions where the system requires a 10/100 Ethernet physical layer without a full MII interface. The companion KSZ8051MNL uses the MII interface, so it is not an interchangeable choice for an existing RMII board.
For layout, place the PHY near the RJ45 or automotive Ethernet connector and follow the manufacturer reference layout for magnetics, termination, and high-speed differential routing. Use the datasheet pin-description table and layout guidance when assigning signals, and verify the RMII clock source before fabrication. The AEC-Q100 qualification makes the KSZ8051RNL particularly relevant to automotive programs, but system-level qualification, EMC testing, and environmental testing remain the responsibility of the final vehicle or equipment design.
جێگرەوەکانی جێگۆڕکێ بۆ KSZ8051RNL — هەمان پاکەت، پین بە پین گونجاو. ئەو بەشانەی پاکەتی جیاوازیان هەیە و پێویستیان بە چاککردنەوەی PCB هەیە لابراون.
جۆرەکان لەم زنجیرەیەدا
مۆدێلەکانی هەمان زنجیرە کە بە شێوەی ڕاستەوخۆ گونجاون لەگەڵ KSZ8051RNL (هەمان شێوە و پێکهاتەی شوێن) — جیاوازە لە Package, Product Type.
KSZ8041RNL
✅ جێگرەوەی ڕاستەوخۆپەیوەندی بۆ نرخ
بینینی داتاشیت →KSZ8051RNL تایبەتمەندییەکان
| Product Type | 10BASE-T/100BASE-TX Ethernet physical-layer transceiver |
| Manufacturer | Microchip Technology |
| Supported Ethernet Speeds | 10 Mbps and 100 Mbps |
| MAC Interface | RMII |
| Supply Type | Single supply |
| Nominal Supply Voltage | 3.3 V |
| پاکێج | 32-pin QFN, 5 mm x 5 mm |
| جۆری دامەزراندن | Surface mount |
| Automotive Qualification | AEC-Q100 standard qualified |
| Termination | 10BASE-T on-chip termination resistors |
| Management Interface | MDC/MDIO management |
| RMII Reference Clock | 50 MHz |
| ژمارەی پین | 32 pins |
| Lead Finish | Lead-free |
| Ethernet Cable Type | Twisted-pair 10BASE-T/100BASE-TX |
| Maximum Data Rate | 100 Mbps |
ڕێنمایی ڕێکخستنی پینی KSZ8051RNL 32-pin qfn, 5 mm x 5 mm
ڕێکخستنی پین بۆ KSZ8051RNL (پاکێجی 32-pin qfn, 5 mm x 5 mm). ژمارەدانی پین، فەنکشنەکان و نەخشەکانی پەیوەندی لە داتاشیتی بەرھەمھێنەردا پێناسە کراون. سەرنجی بدە بۆ شوێنپێی ورد و ڕێنمایییەکانی لەحیمکردن.
هیچ داتای وردی پینئاوت بەردەست نییە بۆ KSZ8051RNL.
سەرنج بدە بە داتاشیت بۆ ڕێکخستنی تەواوی پینەکان.
بەکارهێنانە باوەکان
KSZ8051RNL گونجاوە بۆ 6 بەکارھێنانs: Automotive Infotainment Ethernet, Vehicle Domain Controller, Automotive Head Unit Connectivity, Telematics and Connectivity Unit, Body and Comfort Ethernet Node, Industrial Embedded Ethernet Port.
Automotive Infotainment Ethernet
The KSZ8051RNL fits automotive infotainment systems requiring a compact 10BASE-T/100BASE-TX physical layer with an RMII connection to the Ethernet MAC. Its 3.3 V single-supply operation reduces the number of rails required around the PHY, while the 32-pin QFN package places the transceiver close to the Ethernet connector and magnetics. The 50 MHz RMII reference clock supports a structured digital interface for head units, cockpit controllers, and passenger-zone systems. AEC-Q100 standard qualification makes the device relevant to programs that require an automotive-qualified Ethernet component. The designer should still validate EMC, network topology, clocking, and system-level environmental requirements.
پێشنیارکراو
Vehicle Domain Controller
The KSZ8051RNL can provide the physical layer for a 100BASE-TX Ethernet link between a vehicle domain controller and another Ethernet-capable node. Its RMII interface suits controllers designed with parallel Ethernet data and control signals, and the 5 mm x 5 mm 32-QFN package conserves board area near the connector. With integrated 10BASE-T termination resistors, the design can reduce discrete magnetics-interface complexity. The 3.3 V supply and AEC-Q100 qualification align with typical automotive electrical environments. Implementation should account for the specified 50 MHz clock-source arrangement and verify all RMII timing against the selected MAC.
پێشنیارکراو
Automotive Head Unit Connectivity
The KSZ8051RNL is appropriate for head-unit Ethernet connectivity where a 10/100 network link is required without a full MII bus. RMII limits host-side signal count while preserving a standardized parallel interface to the MAC. The device operates from a single 3.3 V supply and is offered in a compact surface-mount QFN package, allowing placement near the RJ45 or automotive Ethernet connection. Its 10BASE-T on-chip termination resistors can simplify the analog network section. Layout engineers should follow the manufacturer reference layout to maintain controlled differential routing and appropriate separation between digital RMII signals and Ethernet magnetics.
پێشنیارکراو
Telematics and Connectivity Unit
The KSZ8051RNL can support a 100BASE-TX wired connection in automotive telematics and connectivity modules where reliable local Ethernet complements a wireless communication link. The single-supply 3.3 V architecture simplifies power planning, and the RMII interface allows connection to a capable Ethernet controller. Automotive qualification status is particularly useful for harsh temperature and quality-program environments. Because the component supports both 10BASE-T and 100BASE-TX, it can accommodate legacy 10 Mb/s devices as well as higher-speed local links. The final design must confirm the 50 MHz clock configuration, magnetics choice, termination implementation, and network-compliance requirements.
پێشنیارکراو
Body and Comfort Ethernet Node
The KSZ8051RNL can serve compact body and comfort controller networks that exchange data over 10BASE-T or 100BASE-TX links. Its small 5 mm x 5 mm QFN package is useful where connector placement and PCB area are constrained, while RMII provides a defined digital boundary to the system controller. AEC-Q100 standard qualification supports automotive sourcing requirements, and integrated 10BASE-T termination reduces the component count around magnetics. Because low-speed body networks and faster backbones may coexist, validate cable reach, topology, latency, and EMC behavior in the complete enclosure rather than relying only on nominal PHY specifications.
پێشنیارکراو
Industrial Embedded Ethernet Port
The KSZ8051RNL can implement a compact 10/100 Ethernet port in embedded industrial equipment when RMII is preferred over MII and the AEC-Q100-qualified part is acceptable for the environment. The 3.3 V single-supply operation and 32-QFN footprint simplify integration next to the network connector, while integrated 10BASE-T termination assists the magnetics interface. The device supports 100BASE-TX for higher-rate equipment and 10BASE-T for compatibility with legacy links. Engineers should check the exact operating-temperature limits, lifecycle commitments, and any non-automotive qualification requirements before using an automotive-qualified component in an industrial design.
پێشنیارکراو
کورتەی بەرهەمە پێشنیارکراوەکان
داتای سەرچاوەی ئەندازیاری بۆ KSZ8051RNL — بەراوردکردن، ڕێنمایی دیزاین و زانیاری پابەندبوون.
ڕێنمایی هەڵبژاردن
بەراوردکردن لەگەڵ جێگرەوەکان
| پارامەتر | ئەم بەرهەمە | KSZ8041RNL |
|---|---|---|
| Package | 32-QFN (5x5) | 32-QFN (5x5) |
| Brand | Microchip Technology | Microchip Technology |
جیاکەرەوە سەرەکییەکان
- Purpose-built RMII automotive Ethernet PHY (بەراورد بەKSZ8051MNL)
- Automotive qualification aligned with compact vehicle networking (بەراورد بەKSZ8041RNL)
- Compact 5 mm x 5 mm 32-QFN integration (بەراورد بەKSZ8041RNL)
- Integrated 10BASE-T termination and management access (بەراورد بەKSZ8041RNL)
تێبینییەکانی دیزاین
Place the KSZ8051RNL near the Ethernet connector and magnetics, and follow the manufacturer reference layout for the analog network section. Keep the 10BASE-T/100BASE-TX differential pair geometry controlled and route RMII, MDC, MDIO, and clock signals away from the magnetics region. The 32-QFN footprint requires careful thermal-pad assembly because its electrical and thermal performance depends on a continuous solder connection and controlled copper spreading.
Resolve the RMII clock architecture before PCB routing. In 50 MHz mode, the manufacturer document states that the KSZ8051RNL accepts REF_CLK from the MAC or system board at XI, pin 9, while pin 19 is no connect. Confirm source impedance, voltage levels, timing margins, and return paths against the current datasheet so the clock is not driven by two incompatible sources.
Do not substitute the KSZ8051MNL for the KSZ8051RNL on an RMII board merely because both use a related 32-QFN package. The RNL device exposes RMII, whereas the MNL device is associated with MII. Likewise, the KSZ8041RNL requires a pin-function, register, clock-mode, and qualification review before it is treated as a production drop-in replacement.
Decouple the 3.3 V supply locally and route it using the pin and layout requirements in the manufacturer datasheet. The PHY communicates with an Ethernet MAC over digital RMII signals and with magnetics over the analog network interface, so return-current continuity through ground and power planes is important. Validate the design with the selected magnetics, connector, cable, and enclosure rather than treating the nominal PHY supply voltage as a complete power-integrity solution.
زانیاری پابەندبوون
Microchip identifies the KSZ8051 as AEC-Q100 standard qualified and the KSZ8051RNL package as lead-free. RoHS, REACH, halogen-free, and conflict-minerals status are not explicitly stated for the exact part.