MAX113EAG+ - 8-Bit 4-Channel 400ksps ADC | Analog Devices
MPN: MAX113EAG+ ✓ چالاکMAX113EAG+ گشتی
An ADC is a data-conversion IC that converts an analog voltage into a digital code for processing, measurement, or control. The MAX113EAG+ belongs to the flash-converter ADC hierarchy, combining a 4-bit flash stage with a 4-bit successive-approximation stage to achieve 8-bit resolution. This architecture supports sampling-based acquisition in industrial control, sensor conditioning, panel interfaces, and embedded instrumentation.
The principal operating characteristics are 8-bit resolution, 4 analog input channels, a 400ksps conversion rate, and operation from a single +3V supply. The 24-SSOP package is intended for surface-mount assembly. A 1.8µs conversion time supports rapid acquisition, while the 1µA power-down current reduces standby consumption in intermittently operating equipment.
The converter is designed for microprocessor-compatible systems, allowing acquisition results to be transferred through a digital bus and then processed by a microcontroller or logic controller. Its flash conversion method avoids the longer conversion sequence associated with successive-approximation-only ADC architectures. Supply-noise sensitivity, input-source impedance, acquisition timing, and output-code accuracy must still be evaluated against the circuit requirements.
Typical uses include four-channel sensor acquisition, industrial process monitoring, digital panel meters, battery-operated instruments, and embedded control systems. The four-channel architecture reduces the number of separate converters required when several slow or moderate-speed analog signals must be digitized, while the 400ksps rate allows successive readings to be captured rapidly.
The principal design consideration is preserving signal integrity from each sensor to the analog inputs. Use short traces, suitable input filtering, and an analog ground strategy consistent with the manufacturer datasheet. Because the device operates from +3V, confirm that every input remains within its specified analog input range before applying externally generated voltages.
This product page combines the device specifications, application guidance, pin-compatible alternatives, and design notes needed to qualify the MAX113EAG+ for a new PCB. It also provides a structured path for comparing the converter with other same-package ADC options before final schematic approval.
جێگرەوەکانی جێگۆڕکێ بۆ MAX113EAG+ — هەمان پاکەت، پین بە پین گونجاو. ئەو بەشانەی پاکەتی جیاوازیان هەیە و پێویستیان بە چاککردنەوەی PCB هەیە لابراون.
جۆرەکان لەم زنجیرەیەدا
مۆدێلەکانی هەمان زنجیرە کە بە شێوەی ڕاستەوخۆ گونجاون لەگەڵ MAX113EAG+ (هەمان شێوە و پێکهاتەی شوێن) — جیاوازە لە Supply Voltage, Conversion Time, Input Type, Package, Power-Down Current.
MAX113CAG+TG068
✅ جێگرەوەی ڕاستەوخۆپەیوەندی بۆ نرخ
بینینی داتاشیت →MAX117CAG+
✅ جێگرەوەی ڕاستەوخۆ ⚠️ تایبەتمەندییەکان پشتڕاست نەکراونەتەوە📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)
MAX117EAG+
✅ جێگرەوەی ڕاستەوخۆ ⚠️ تایبەتمەندییەکان پشتڕاست نەکراونەتەوە📋 جێگرەوەی سەرچاوە (لە کاتالۆگدا نییە)
MAX113EAG+ زۆرترین ڕێژە و تایبەتمەندییە کارەباییەکان
| ADC Resolution | 8 bit |
| Number of Analog Input Channels | 4 channels |
| Maximum Conversion Rate | 400ksps |
| Conversion Time | 1.8µs |
| ڤۆڵتیەی دابینکردن | +3V |
| Power-Down Current | 1µA |
| Conversion Architecture | Half-flash, 1 flash conversion |
| Digital Interface | Microprocessor-compatible |
| پاکێج | 24-pin SSOP |
| جۆری دامەزراندن | Surface mount |
| Input Type | 4 single-ended analog inputs |
ڕێنمایی ڕێکخستنی پینی MAX113EAG+ 24-pin ssop
ڕێکخستنی پین بۆ MAX113EAG+ (پاکێجی 24-pin ssop). ئەم پێکھاتە ئەنالۆگە پینی چوونەژوورەوە، دەرچوون و دابینکردنی وزەی ھەیە. سەرنج بدە بە داتاشیتی بەرھەمھێنەر بۆ ڕێکخستنەکانی پینی لادانی ئۆفسێت، قەرەبووکردنەوە و چالاککردن. گونجاوە بۆ ڕێکخستنی ئیشارەت و خولەکانی بەرزکەرەوە.
هیچ داتای وردی پینئاوت بەردەست نییە بۆ MAX113EAG+.
سەرنج بدە بە داتاشیت بۆ ڕێکخستنی تەواوی پینەکان.
بەکارهێنانە باوەکان
MAX113EAG+ گونجاوە بۆ 6 بەکارھێنانs: Industrial Sensor Acquisition, Digital Panel Meter, Battery-Powered Instrument, Embedded Control System, Process Monitoring, Portable Data Logger.
Industrial Sensor Acquisition
The MAX113EAG+ fits four-channel industrial sensor acquisition because it combines 8-bit resolution with a 400ksps conversion rate and 1.8µs conversion time. Its single +3V operation simplifies low-voltage instrumentation, while the microprocessor-compatible interface allows the controller to retrieve successive measurements. Use the device when sensor outputs fall within the specified analog range and the application requires compact conversion rather than high-resolution mixed-signal performance. The four inputs can reduce the number of separate converters in a panel, but input filtering and grounding should prevent sensor and digital noise from limiting measurement repeatability.
پێشنیارکراو
Digital Panel Meter
The MAX113EAG+ is appropriate for a digital panel meter that must capture several analog channels at modest resolution. Four inputs support sensor or setpoint monitoring without requiring four separate converter packages, and the 400ksps rate supports rapid sequential sampling. Its 24-pin SSOP package is suitable for compact surface-mount instrument designs. The 1µA power-down current is valuable when the meter operates intermittently, although panel noise, display excitation, and ground-return paths still require careful layout to prevent meter readings from becoming unstable.
پێشنیارکراو
Battery-Powered Instrument
The MAX113EAG+ supports battery-powered instruments because it operates from +3V and provides a 1µA power-down mode for periods between measurements. Its 400ksps conversion rate allows multiple readings to be captured from four inputs during a short active window, helping the instrument obtain useful data before returning to a low-power state. The 8-bit resolution is suitable for threshold, trend, and basic process measurements where finer quantization is unnecessary. Battery life calculations should include the active conversion current, digital interface activity, and any external display or sensor loads.
پێشنیارکراو
Embedded Control System
The MAX113EAG+ can serve as the acquisition front end in an embedded control system requiring several analog measurements and a straightforward processor interface. Its microprocessor-compatible digital interface supports integration with control logic, while 400ksps throughput provides adequate speed for many feedback, monitoring, and setpoint tasks. The single +3V supply is useful in compact embedded equipment. Select it when 8-bit measurement resolution is sufficient and validate acquisition timing against the controller's bus activity. For higher precision or wider dynamic range, a different converter class would be more appropriate.
پێشنیارکراو
Process Monitoring
The MAX113EAG+ suits process-monitoring equipment that tracks multiple slowly changing analog quantities such as temperature, pressure, or position. Four channels can represent several sensing elements, and the 1.8µs conversion time permits closely spaced readings for trend analysis. The 8-bit output is appropriate for coarse process indication, alarm thresholds, and basic closed-loop adjustment. Use input dividers or transducers appropriate to each signal, keep the acquisition front end away from high-current switching paths, and account for source impedance and acquisition timing in the analog network.
پێشنیارکراو
Portable Data Logger
The MAX113EAG+ fits a portable data logger that records four low-bandwidth analog channels while minimizing standby consumption. The converter's 400ksps rate provides more sampling capability than typical slow sensor outputs require, while its 1µA power-down mode can reduce current during inactive logging intervals. An 8-bit result is suitable for basic environmental or equipment-condition records and can reduce storage and processing requirements. The enclosure should be designed to prevent connector transients, moisture, and switching supplies from introducing errors greater than the selected measurement resolution.
پێشنیارکراو
کورتەی بەرهەمە پێشنیارکراوەکان
داتای سەرچاوەی ئەندازیاری بۆ MAX113EAG+ — بەراوردکردن، ڕێنمایی دیزاین و زانیاری پابەندبوون.
ڕێنمایی هەڵبژاردن
بەراوردکردن لەگەڵ جێگرەوەکان
| پارامەتر | ئەم بەرهەمە | MAX113CAG+ | MAX117CAG+ | MAX117EAG+ |
|---|---|---|---|---|
| Package | 24-pin SSOP | 24-pin SSOP | 24-pin SSOP | 24-pin SSOP |
| Brand | Maxim Integrated | Maxim Integrated | Maxim Integrated | Maxim Integrated |
| Resolution | 8 bit | 8 bit | 8 bit | 8 bit |
| Conversion Rate | 400ksps | 400ksps | 400ksps | 400ksps |
| Conversion Time | 1.8µs | 1.8µs | 1.8µs | 1.8µs |
| Supply Voltage | +3V | +3V | +3V | +3V |
| Power-Down Current | 1µA | 1µA | 1µA | 1µA |
| Conversion Architecture | Half-flash, 1 flash conversion | Half-flash, 1 flash conversion | Half-flash, 1 flash conversion | Half-flash, 1 flash conversion |
| Digital Interface | Microprocessor-compatible | Microprocessor-compatible | Microprocessor-compatible | Microprocessor-compatible |
جیاکەرەوە سەرەکییەکان
- Matches the four-channel MAX113 family configuration in the same 24-pin SSOP footprint (بەراورد بەMAX113CAG+)
- Provides a 400ksps acquisition rate for compact four-channel measurements (بەراورد بەMAX117CAG+)
- Supports low-duty-cycle operation from a single +3V rail (بەراورد بەMAX117EAG+)
تێبینییەکانی دیزاین
Route each analog input directly to its assigned pin and keep the paths short, with no digital clock or bus traces running directly beneath them. Place input filtering components close to the converter so transient protection and anti-aliasing networks do not add long high-impedance routes. Use the manufacturer package drawing and pin-description table to preserve the 24-pin SSOP footprint and maintain adequate clearance around neighboring components.
Do not assume that an 8-bit converter can accurately measure a signal that crosses or approaches its allowed input range. Clamp external voltages, confirm the reference configuration, and account for source impedance during each conversion. The MAX113EAG+ uses a half-flash architecture with a stated 1.8µs conversion time, so acquisition and sample-and-hold settling requirements must be checked before reading the result.
Provide a stable +3V rail and follow the manufacturer bypass recommendations at the supply pins. Keep converter current paths separate from noisy sensor returns and high-current digital loads. In portable equipment, include the active supply current, power-down current, and external circuit consumption in the battery budget; the converter's 1µA power-down figure alone does not determine total standby consumption.
Use a single consistent ground reference for the converter, reference network, input sources, and digital interface. If the analog source has appreciable impedance, include its settling behavior in the acquisition design rather than relying only on the nominal 1.8µs conversion time. Verify sampled-code repeatability under the intended switching conditions and add filtering where sensor or digital coupling causes unstable readings.
زانیاری پابەندبوون
RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals status require confirmation from the current manufacturer product documentation or the relevant declaration.