MAX113CAG+ 8-Bit 4-Channel ADC | Analog Devices
MPN: MAX113CAG+ ✗ کۆتایی ژیانMAX113CAG+ گشتی
An ADC is a semiconductor device that converts an analog input voltage into a digital code for processing, storage, or control. The MAX113CAG+ belongs to the ADC and DAC hierarchy within integrated circuits and combines a four-channel multiplexer, sample-and-hold circuitry, an 8-bit flash converter, and a parallel digital interface in one package. Its four single-ended inputs allow one controller to monitor multiple analog sources without requiring a separate converter for every channel.
Key features include 8-bit resolution, four analog input channels, a +3 V single-supply operating requirement, a 400 ksps conversion rate, and a 1.8 µs conversion time. The half-flash conversion architecture supports throughput-oriented acquisition while preserving the simple parallel interface commonly used by microprocessors and programmable logic controllers. A dedicated power-down function reduces supply current to 1 µA when intermittent measurements are sufficient.
The MAX113/MAX117 family is designed for microprocessor-compatible data acquisition. The MAX113CAG+ provides four channels in the 24-pin SSOP package, distinguishing it from eight-channel family members. Its architecture is appropriate when several slowly changing or periodically sampled analog signals must be digitized into an 8-bit value. Because the converter uses a parallel data interface, the host processor must connect its data bus and control signals according to the manufacturer pin-description table.
Typical applications include industrial process monitoring, factory automation, battery-powered instrumentation, data loggers, embedded environmental measurement, and general-purpose control systems. The 400 ksps rate is useful when the controller needs to scan all four inputs quickly, while the 8-bit resolution is appropriate for position, level, threshold, and status monitoring rather than laboratory-grade instrumentation requiring higher resolution.
Designers should account for input-range selection, signal conditioning, acquisition timing, and reference accuracy when assigning the four analog channels. The +3 V supply and single-ended inputs simplify portable measurement systems, while the 24-pin SSOP footprint requires careful routing of parallel bus signals. Use the manufacturer pin-description table when assigning tracks and confirm the power-down polarity before integrating the control logic.
This product page organizes the MAX113CAG+ specifications, practical application guidance, lifecycle information, and verified same-package alternatives. It also highlights design constraints that are easy to overlook when selecting a multi-channel ADC, including interface timing, supply architecture, channel multiplexing, and power management.
جێگرەوەکانی جێگۆڕکێ بۆ MAX113CAG+ — هەمان پاکەت، پین بە پین گونجاو. ئەو بەشانەی پاکەتی جیاوازیان هەیە و پێویستیان بە چاککردنەوەی PCB هەیە لابراون.
جۆرەکان لەم زنجیرەیەدا
مۆدێلەکانی هەمان زنجیرە کە بە شێوەی ڕاستەوخۆ گونجاون لەگەڵ MAX113CAG+ (هەمان شێوە و پێکهاتەی شوێن) — جیاوازە لە Supply Voltage, Conversion Time, Data Interface, Package, Power-Down Current.
MAX113EAG+TG068
✅ جێگرەوەی ڕاستەوخۆپەیوەندی بۆ نرخ
بینینی داتاشیت →MAX113CAG+ زۆرترین ڕێژە و تایبەتمەندییە کارەباییەکان
| Converter Type | 8-bit flash ADC |
| Architecture | Half-flash |
| Number of Channels | 4 channels |
| Input Type | Single-ended |
| ڤۆڵتیەی دابینکردن | +3 V |
| Conversion Rate | 400 ksps |
| Conversion Time | 1.8 µs |
| وردی | 8 bits |
| Power-Down Current | 1 µA |
| Data Interface | Parallel microprocessor-compatible interface |
| Multiplexer Ratio | 1:1 |
| Number of Internal ADCs | 1 |
| پاکێج | 24-pin SSOP |
| جۆری دامەزراندن | Surface mount |
| دۆخی چرخەی ژیان | Obsolete |
ڕێنمایی ڕێکخستنی پینی MAX113CAG+ 24-pin ssop
ڕێکخستنی پین بۆ MAX113CAG+ (پاکێجی 24-pin ssop). ئەم پێکھاتە ئەنالۆگە پینی چوونەژوورەوە، دەرچوون و دابینکردنی وزەی ھەیە. سەرنج بدە بە داتاشیتی بەرھەمھێنەر بۆ ڕێکخستنەکانی پینی لادانی ئۆفسێت، قەرەبووکردنەوە و چالاککردن. گونجاوە بۆ ڕێکخستنی ئیشارەت و خولەکانی بەرزکەرەوە.
هیچ داتای وردی پینئاوت بەردەست نییە بۆ MAX113CAG+.
سەرنج بدە بە داتاشیت بۆ ڕێکخستنی تەواوی پینەکان.
بەکارهێنانە باوەکان
MAX113CAG+ گونجاوە بۆ 6 بەکارھێنانs: Industrial Process Monitoring, Battery-Powered Data Logging, Embedded Environmental Sensing, Factory Automation Control, Portable Test and Measurement, Battery Charger Status Monitoring.
Industrial Process Monitoring
The MAX113CAG+ suits controllers that monitor four single-ended process signals through a shared 8-bit converter. Its 400 ksps conversion rate and 1.8 µs conversion time allow the host processor to scan the available channels rapidly, while the +3 V supply simplifies integration into compact industrial electronics. The 8-bit resolution is appropriate for supervisory measurements such as valve position, tank level, or actuator status. Field-connected inputs should receive suitable signal conditioning and protection before reaching the ADC.
پێشنیارکراو
Battery-Powered Data Logging
The MAX113CAG+ fits intermittent data-logging systems that periodically acquire several analog measurements. Its power-down mode reduces current consumption to 1 µA, allowing the controller to disable the converter between samples, while the four-channel architecture avoids four separate ADC packages. A 400 ksps acquisition capability is useful when sensors require closely spaced readings. Battery life also depends on the host controller, reference circuitry, input networks, and measurement interval, which must be evaluated as a complete system.
پێشنیارکراو
Embedded Environmental Sensing
The MAX113CAG+ can digitize single-ended outputs from environmental sensors such as temperature, light, humidity, and air-quality devices when 8-bit resolution is sufficient. Four channels let one controller handle several sensor outputs without duplicating the converter, and the parallel interface provides direct access to the converted codes. The 400 ksps rate supports rapid sampling, although practical environmental systems are often limited by sensor response time. Choose external or internal reference configuration according to the stability required for the measurement chain.
پێشنیارکراو
Factory Automation Control
The MAX113CAG+ is useful in small factory-control modules that must read multiple analog thresholds or machine-status signals. Its four single-ended inputs reduce analog-front-end duplication, and the 400 ksps rate permits rapid polling by a programmable controller. The 8-bit output can represent discrete operating bands or basic control variables without the complexity of a higher-resolution converter. Long wiring runs may require filtering, grounding, and surge protection to keep conducted disturbances outside the ADC input range.
پێشنیارکراو
Portable Test and Measurement
The MAX113CAG+ supports portable measurement instruments that acquire up to four single-ended channels through a compact 24-pin SSOP device. The +3 V operating supply and 1 µA power-down current are helpful in handheld or battery-operated equipment, and the 1.8 µs conversion time supports repeated sampling. The parallel bus must be routed carefully within a compact PCB, and unused pins and supply connections must follow the manufacturer recommendations. For precision laboratory measurements, verify whether 8-bit resolution provides sufficient accuracy.
پێشنیارکراو
Battery Charger Status Monitoring
The MAX113CAG+ can monitor several single-ended voltage or current-sense outputs in a battery-management or charger-control subsystem. Four channels provide compact multiplexed acquisition for pack voltage, cell balance status, temperature indicators, or auxiliary rails, while the +3 V supply operation can align with embedded control electronics. The 1 µA power-down mode is valuable when measurements occur only during periodic supervisory scans. The 8-bit result should be checked against the required resolution and accuracy of each monitored quantity.
پێشنیارکراو
کورتەی بەرهەمە پێشنیارکراوەکان
داتای سەرچاوەی ئەندازیاری بۆ MAX113CAG+ — بەراوردکردن، ڕێنمایی دیزاین و زانیاری پابەندبوون.
ڕێنمایی هەڵبژاردن
بەراوردکردن لەگەڵ جێگرەوەکان
| پارامەتر | ئەم بەرهەمە | MAX113EAG+ |
|---|---|---|
| Package | 24-pin SSOP | 24-pin SSOP |
| Brand | Analog Devices | Analog Devices |
| Resolution | 8 bits | 8 bits |
| Number of Channels | 4 channels | 4 channels |
| Supply Voltage | +3 V | +3 V |
| Conversion Rate | 400 ksps | 400 ksps |
| Conversion Time | 1.8 µs | 1.8 µs |
| Power-Down Current | 1 µA | 1 µA |
| Input Type | Single-ended | Single-ended |
| Architecture | Half-flash | Half-flash |
جیاکەرەوە سەرەکییەکان
- Combines four single-ended channels with a 400 ksps conversion rate (بەراورد بەMAX113EAG+)
- Single +3 V operation supports compact embedded acquisition (بەراورد بەMAX113EAG+)
- Low-power shutdown supports intermittent measurement (بەراورد بەMAX113EAG+)
- Four-channel 24-pin SSOP implementation (بەراورد بەMAX113EAG+)
تێبینییەکانی دیزاین
Route the parallel data bus away from sensitive analog inputs, and place input, supply, and reference connections close to the device using short paths. Maintain a continuous ground reference beneath and around the converter, with particular care around the single-ended input pins. Because the MAX113CAG+ is a multiplexer-based 4-channel ADC, trace matching and grounding influence how closely adjacent channels track during sequential acquisition.
Do not treat the 400 ksps figure as the time required to complete an entire four-channel scan. The 1.8 µs conversion time describes an individual conversion, while multiplexing, acquisition time, host read timing, and any input-settling interval can increase the total scan duration. Allow adequate settling time between channel switches and verify operation against the timing diagrams in the manufacturer datasheet.
Use the power-down function when the acquisition system is idle, since the converter can reduce its current consumption to 1 µA. Confirm the control polarity, enable sequence, and settling behavior before using the shutdown mode for repeated measurements. Host firmware should also avoid continuous conversions when the application only needs periodic samples, because overall energy use includes the converter, reference circuitry, processor, and sensor interfaces.
Keep analog input traces short, isolate them from switching nodes, and use a quiet ground path for the reference and analog supply pins. If the source impedance is significant, include suitable settling and buffering behavior rather than assuming the multiplexer can charge the acquisition network instantaneously. Check each signal against the input range and reference arrangement specified by the manufacturer to avoid clipping or conversion errors.
زانیاری پابەندبوون